Tender For Repairs/Maintenance Of Ht Electric System/Vcb /Rmu/Transformers/Ht Cables At Darjipura At Afs Vadodara
Tender Value
42 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
6 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs/Maintenance Of Ht Electric System/Vcb /Rmu/Transformers/Ht Cables At Darjipura At Afs Vadodara
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5m deep and getting out in soft/ loose soil for laying of cable complete all as specified and directed. |
| 2 | Excavation in trenches exceeding 1.5 m depth but not exceeding 3 mtr and 1.5 m wide and getting out in soft/ loose soil for laying of cable complete all as specified and directed. |
| 3 | Returing, filling in trenches including spreading, leveling, watering & well ramming in layers not exceeding 25 cm (soft/loose soil) complete all as specified & directed. |
| 4 | Removing excavated material n.exc. 50 m and depositing where directed as a level n.exc. 1.5 m above the starting points. |
| 5 | Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.Note : Punned thickness shall be measured & paid |
| 6 | Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge. |
| 7 | S&F framed work as in door or gate of angle or other section with gausset plates, rail, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting also fastening and fixing complete conforming to Fe-410-0 or Fe-310-0. |
| 8 | M&L for cutting chasing in hard standing road/path/drain making holes in concrete wall etc for passing through of cable and making good as per existing by using PCC (1:3:6) type C-2 using 40 mm graded stone aggregate all as specified and directed. |
| 9 | M&L for road crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydrolic pipe jacking technique complete including tunneling, excavation in any type of soil including hard rock, GI pipe light grade of size up to 100 mm dia including fittings to carry LT UG cables of size upto 400 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.Note: GI pipe shall be measured and paid separately |
| 10 | S&F anti-climbing device in replacement, fabricated out of 50x6 mm FI 8 mm of 15 Cm long MS bar, 12 mm dia / flat spikes made out to shape all as specified and as directed . |
| 11 | M & L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) for foundation of the pole complete all as specified and directed. |
| 12 | M & L for PCC (1:3:6) type C-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work complete all as specified and directed. |
| 13 | Dismantling & taking out unserviceable steel & iron items from poles i.e cross arms, bracing, supports, clamps and back plates etc. including nuts & bolts complete all as specified and directed. |
| 14 | Fixing only the serviceable MS cross arms, F1 clamp etc with and including acessories such as bolt, nuts and washers etc as obtained from item No 12 here in before on electrical pole at any location with and including painting of steel surfaces with two coats of aluminium paint over a coat of red oxide zinc chrome primer after preparation of old surfaces all as specified and directed. |
| 15 | Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge. |
| 16 | Dismantling of stay assembly complete with insulators etc and removing from the site. |
| 17 | M&L for stay assembly for HT poles comprising of 20mm dia, 2.15 mtr long galvanized stay rod , having 7 / 3.15mm GI stay wire stranded and 300mm X 500mm X 6mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/accessories like loop type insulator, shackle & stay clamps, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Dismantling & taking out of old existing unserviceable insulators of any description and in any position from HT poles all as specified & directed. |
| 19 | Supply and fixing pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height and 150mm dia suitable for working pressure upto and including 11000 volts grade complete all as specified for HT lines fixed on poles. |
| 20 | Supply and Fixing disc type insulator, porcelain, vitreous 150 mm height and 150 mm dia ball and socket type white/brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts grade complete all as specified for HT lines fixed on poles. |
| 21 | Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing HT Poles/Lines all as specified & directed. |
| 22 | Material & labour for supply and fixing of aluminium conductor, steel reinforced (ACSR) of any size/description on HT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified & directed by Engineer-in-Charge. |
| 23 | Taking out all connections and repairing/overhauling of air break gang operated switch triple pole, with Drop out fuse unit mechanically operated mounted on insulators and steel frame installed vertically / horizontally , replacement of broken/worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly on contacts refixed the same after repair complete all as directed |
| 24 | Supply and fixing following components of air break gang operated switch:- |
| 25 | (a) Female contact or fixed contact heavy duty and high conductive metal assambly brass/Gun metal complete capacity 200 Amp 11 KV |
| 26 | (b) Male contact or Moving contact blade heavy duty and high conductive metal assambly brass/Gun metal complete capacity 200Amp 11 KV |
| 27 | (c) Tinned copper flexible jumper 200A/400A |
| 28 | (e) MS Jumper carrier |
| 29 | (f) Back connector plate |
| 30 | (e) Fixed top contact/L contact assambly brass/Gun metal(DO) |
| 31 | (f) Fixed bottom conatct assambly brass/Gun metal(DO) |
| 32 | (g) post type insulater 12 KV porecelain 254mm height |
| 33 | (h) PVC bird protection disc in red colour 15cm-18cm dia fixed with insulator bottom for protection from birds/any wild animal complete |
| 34 | 11 KV Hand gloves rubber ISI Mark |
| 35 | Discharge rod complete with clamp having screw type arrengement for fixing tightly on conductor (ACSR size from raccon to MDOSE with nut bolt & saddle for earth wire). The operating rod fixing with clamp shall be made of epoxy resin based tightly insulated fibre glass tube 32mm OD 1.7 Mtr long in places with proper coupling arrengement complete |
| 36 | Supply, fixing, commissioning and testing of outdoor type 11 KV , gang operated switch (GOD), single throw single break off load type, of current rating upto 400 Amps, nine pole, each pole consisting of galvanized steel base, HT insulators as per IS, non ferrous knife and spring, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes of size 25 mm bore for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dipped galvanized and non ferrous heavily tinned to withstand weather and suitable for vertical mounting with fuse unit carrier of 400 Amps rating and fuse element upto 50 Amps along with rod for expulsion fuses and 3 Nos post insulators for fuses including dismantling and taking down existing unserviceable GOD switch complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Dismantling steel poles /struts, any size and Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper , welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note :- Earth work, PCC in foundation and coping, cross arms, danger notice board and anti climbing device shall be measured and paid separately |
| 38 | Dismantling and taking down existing unserviceable lightening arrestor of any capacity and any description and Supply, fixing, commissioning & testing of distribution class lighting arrestor of rating 11 KV capacity and 10 KA NDC(Peak) confirming to to IEC-99.4 including brackets, clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply ,laying, jointing and testing 11 KV (Earthed), aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 95 Sqmm 3 core including taking down old cable complete all as specified and directed by the Engineer-in-Charge. |
| 40 | Supply , jointing and testing cable jointing kit of 11 KV grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sq mm, including taking down old unserviceable one ,complete all as specified and directed by the Engineer-in-Charge. |
| 41 | Supply , jointing and testing cable jointing kit of 11 KV grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for end termination joint outdoor heat shrink joints size 3 core 120sqmm-185 sqmm 11KV including taking down old unserviceable ,complete all as specified and directed by the Engineer-in-Charge. |
| 42 | S & F cable jointing kit for 11 KV(Earthed) grade cable for indoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured at cable of size 50 sqmm to 95sqmm |
| 43 | S & F cable jointing kit for 11 KV(Earthed) grade cable for end termination joint indoor type heat shrink joints complete with jointing materials and accessories suitable for 3 core XLPE armoured cable of size 3 core 120sqmm-185 sqmm 11KV. |
| 44 | S&F cable jointing kit for 11 KV(Earthed) grade cable for straight through joint heat shrink type complete with jointing materials and accessories suitable for 3 core XLPE armoured at cable of size 50 sqmm to 95sqmm |
| 45 | All as per item No 33 above but straight through heat shrink type joint 3 core XLPE armoured at cable of size 120 sqmm to 185 sqmm. Note for item no 29 to 34 :- (i) Rate quoted shall be deemed to be inclusive of necessary excavation/ filling making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge. |
| 46 | M&L for Trimming branches of trees, bushes, hurbs 10 Mtr surrounding of 4 pole/ 2 pole structure including removal of tree branches etc to a distance not exceeding 50 mtr from over head line all as specified and directed. |
| 47 | Supply and fix Danger notice plate of 1.6 mm thick miled steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal RED colur and fixed with MS clamps bolts and nuts of approved size for HT 25x20 cm size |
| 48 | Repair of old rusted/worn out wire mesh chain link fencing min 4mm dia GI wire & opening size 2.5'' (appx), including necessary welding ,clamping nut bolt etc including painting with aluminium paint over coat of red oxide primer complete all as specified and directed. |
| 49 | Fixing only chain link fencing including line wires any mesh size and type of soil rails straining bolts etc.including provision of binding wire complete all as specified and as diected. |
| 50 | Supply only chain link fencing made out of MS galvanized Minimum 4mm dia GI opening size 2.5\\"(approx) all specified and directedNote : Weight of chain link fencing be measured through BOO only. |
| 51 | M&L for mild steel TMT bars 6 mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 52 | Excavating Post holes in any type of soil (or similar holes)each n exc 0.5 cum,getting out, returning filling,and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25cm,watering,and removing surplus soil to a distance n exc 50m and making good surface |
| 53 | M&L for mild steel work such as in angle iron, flat iron, fillets, hand rails half round or other steel section or core for wooden hand rail straight portion drilled and countersunk for baluster running bars for doors balusters running bars for doors baluster noising to steps including embedding in concrete and screwing etc,wind ties for roof including securing bolts post and struts in fencing including cutting tops to shape as directed drilling holes notching for wire including all necessary works complete all as specified and directed. |
| 54 | S & F screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each scerwed end to be fitted with washers and one hexagonal or square nut exc 10cm and n exc 15cm long complete all as specified and as directed.. Please Enable Macros to View BoQ information |
| 55 | S & F screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each scerwed end to be fitted with washers and one hexagonal or square nut exc 10cm and n exc 15cm long complete all as specified and as directed.. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender