| Sl. No. | Item Description |
| 1 | Supply and clamping of 3½ X 240 sq.mm PVC LTUG armoured cable on existing compund wall with clamps. |
| 2 | Supply and clamping of special clamp using 9\\"cable riser with 100mm anchor fastener bolt, nuts type 4\\" heavy saddle clamp with GI bolt nuts etc. on existing compound wall. (Incoming 3/12x240sq.mm LTUG cable From MV panel to Old workshop near) |
| 3 | Supply and Laying of 1\\" pipe from Enclosure to machinaries in ground level with necessary connections. |
| 4 | Supply and fixing of MS Trunking box suitable (h-1465mm x L-406mm x d-140mm) for VTPN DB made of 16 SWG MS Sheet i/c fabrication such as cutting bending welding drilling holes painting etc. |
| 5 | Supply and fixing of MS Trunking box suitable (h-775mm x L-165mm x d-127mm) for VTPN DB made of 16 SWG MS Sheet i/c fabrication such as cutting bending welding drilling holes painting etc. |
| 6 | Supply and fixing of MS Trunking box suitable (h-200mm x L-415mm x d-175mm) for Cable End Box for Change over switch made of 16 SWG MS Sheet i/c fabrication such ascutting bending welding drilling holes painting etc., |
| 7 | Supply and laying of UTP Cat 6 camera cable through 25mm PVC rigid pipe concealed in the wall/ceiling with necessary connection and making good of the concealed portion with painting of suitable colour Make : Finolex or Dlink or equivalent |
| 8 | Supply and fixing of 2 Nos. 6/16A two module socket, 2Nos 16A module switch on suitable module surface mounting Box (GI) with module cover plate (plastic) on wall with connections. (Higher end) |
| 9 | Supply and run of 2 of 2.5 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sqmm PVC insulated sc unsheathed copper wire with painting of suitable colour. |
| 10 | Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 6sq.mm copper wire with painting of suitable colour |
| 11 | Supply and run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 10sq.mm copper wire with painting of suitable colour |
| 12 | Earthing as per the ISI specification with an earth electrode of 2.10metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 13 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. |
| 14 | Supply, Installation and termination of RJ 45 Cat-6 I/O Socket with, Back box, Face plate with surface mount. (Make:D link/Legrand/ Equivalent). |
| 15 | Supply, fixing and termination of Cat 6 UTP Patch cord (higher end) of 2 metre.Make:D link or ADC or Molex or Digilink or equivalent |
| 16 | Supply and installation 19\\" 6U three tier MS Rack for housing LAN Switches with top and Bottom Cable Entry provision along with necessary power distribution unit,cable manager, fan and Lockable Toughened Glass Door. |
| 17 | Supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of Cooling,Dehumidifying,Air Circulating,Filtering.The installation works for the above split type AC units includes the following.1.Mounting / Fitting Indoor and outdoor units at their respective locations.2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.5. Leakage testing the entire system unit.6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 Sq mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit (Make: Carrier/Voltas/equivalent) |
| 18 | Supply of 5 KVA Electronic Automatic Voltage Stabilizer (Higher end) with Input Voltage range of 170 Volt – 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 19 | Supply and fixing of water drain pipe line (1 PVC pipe). |
| 20 | Supply and fixing of MS stand for fixing Outdoor unit |
| 21 | Supply and laying of 5/8\\" and 3/8\\" copper refrigerant pipe of 0.8mm thick with 2.5 sqmm 3 core chord between indoor and outdoor unit. (Extra beyond 3 mts supplied with AC unit) |
| 22 | Supply and run of 2 of 1.5 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sqmm copper wire and making good of the concealed portion with suitable colour |
| 23 | Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End |
| 24 | Supply and run of 2 of 1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 1.5sq.mm copper wire with painting of suitable colour |
| 25 | GST 18 % Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender