Drinking Water Supply and Sanitation Government Departments Closing in 3 days TDR #57609436

Tender For Drilling Of Bore Hole By Dth/Rotary/Combination Rig Of 150 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube Well At Rural And Urban

Issued by Government Departments · Tonk, Rajasthan
Tender Value
1.50 Crore
Estimated cost
Bid Submission
29 Sep 2026
3 days left
EMD
3 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tonk → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Drilling Of Bore Hole By Dth/Rotary/Combination Rig Of 150 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube Well At Rural And Urban Scheme Under Jurisdiction Of Division Malpura Under Annual Rate Contract.

BOQ

Name of Work:- Drilling of bore hole by DTH/Rotary/Combination rig of 150 mm dia, supply and installation of energy efficient Submersible Pump sets, Panels, Cables and other allied works including commissioning and testing of tube well at rural and urban scheme under jurisdiction of Division Malpura under Annual rate contract.
Sl. No. Item Description
1Rates are based on revised BSR 2023 exclusive of GST
2Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.
3Nominal bore 150 mm dia.
4Add 15% extra on above itemfor drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr.
5Add 40% extra on above item for drilling depth beyond 200 mtr, rate shall be applicable for only extra depth beyond 200 mtr .
6Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.
7Nominal bore 150 mm dia.
8Add 15% extra on above item for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
9Add 30% extra on above item for drilling depth beyond 200 mtr drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
10Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.
11Nominal bore 150 mm dia.
12Add 15% extra on above item for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
13Add 30% extra on above itemfor drilling depth beyond 200 mtr drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
14Construction of tube well from ground level and up to 100 mtr. depth and above of following sizes in all types of soils in alluvium strata, unconsolidated formation such as pebbles, boulders etc. by \\"bailing\\" method and without gravel packing as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering of casing pipe but excluding cost of the casing pipe. The tube well should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water.
15Nominal bore 150 mm dia.
16Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr.
17Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work will include lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water.
18Nominal bore 150 mm dia.
19Add 15% extra on above item ( item no. 18,19 ) for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr.
20Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water.
21Nominal bore 150 mm dia.
22Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as peramended up to date.
23Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.
24Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.
25Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes
26150 mm dia NB (Thickness of pipe 5.0mm & mass of tube 20.13 Kg/m)
27Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.
28150 mm dia nominal bore of 4.8 mm thickness
29Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.
30Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
31Up to 2.0 KW
32Above 2.0 KW
33Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283- 2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
34Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
35Up to 5.5 KW (7.5 HP) & head above 120 mtr.
367.5 KW (10 HP) & head up to 120 mtr.
377.5 KW (10 HP) & head above 120 mtr.
389.3 KW (12.5 HP) & head up to 120 mtr.
399.3 KW (12.5 HP) & head above 120 mtr.
4011 KW (15 HP) & head up to 120 mtr.
4111 KW (15 HP) & head above 120 mtr.
4213 KW (17.5 HP) & head up to 120 mtr.
4313 KW (17.5 HP) & head above 120 mtr.
4415 KW (20 HP) and above, head up to 120 mtr.
4515 KW (20 HP) and above, head above 120 mtr.
46Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gaugeM.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.
47Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.upto 5 HP
48Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
49Above 5 HP and up to 10 HP
50Above 10 HP and up to 15 HP
51Above 15 HP and up to 20 HP
52Above 20 HP and up to 30 HP
53Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
543 core 4.0 Sq.mm
553 core 6.0 Sq.mm
563 core 10.0 Sq.mm
573 core 16.0 Sq.mm
58Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
5910.0 Sq.mm, 4 core
6016.0 Sq.mm, 4 core
6125.0 Sq.mm, 3.5 core
6235.0 Sq.mm, 3.5 core
63Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
64Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
65Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
66150 mm dia
67Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect.
6832 mm dia
6950 mm dia
70Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.
7140 mm dia
7250 mm dia
7363 mm dia
7475 mm dia
7590 mm dia
76Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with lockingarrangement of following dia.
7750 mm dia
7865 mm dia
7980 mm dia
80Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.
81Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four no's of superior quality and approvedmake, including interconnections complete job.
821000 litres capacity
832000 litres capacity
84Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect.
85Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes
8665 mm dia
8780 mm dia
88Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe.
89Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as perspecification with safety cover.
90Construction of bore hole for shallow depth tube well from ground level to required depth for following size for all type of relevant strata by percussion/ rotary drilling/ hand boring method excluding cost of casing pipe. The bore hole should be as per nominal bore of PVC casing pipe. The work will be complete after obtaining sand free water.
91150 mm dia nominal bore
92Providing and Lowering of ISI mark PVC-U casing and screen pipe as per IS : 12818 : 2010 or amended up to date having pipe thickness as per IS code suitable for TW and DCB with threading , winding with superior quality of plastic mesh & rope in three layers with end cap complete as per technical specification and direction of Engineer In charge.
93Shallow well casing pipe (CS) suitable for depth up to 80 mtr.
94150 mm nominal dia ( internal dia ).
95Medium well casing pipe (CM) suitable for depth above 80 mtr and up to 250 mtr.
96150 mm nominal dia ( internal dia )
97SITC of DOL/Star Delta Starter Digital type Electric Control Feeder Panel with projected canopy for three phase pump set, comprising MCCB, Electronic Protection relay with fault indicators (O/L,UC, Unbalance, E/f, L/R, Phase reversal, Phase loss protection), AC-3 duty power contactor(s), or/and S/D Timer selected as per OEM certified Type-2 Coordination chart of PHED approved makes conforming to IEC 60947-4-1, Voltage monitoring relay (with adjustable under-voltage, over-voltage, phase failure and phase sequence protection), Capacitor 440V AC Heavy duty MPP type capacitor of suitable kVAr rating, multifunction digital meter with three-line display(V,A,F,PF, run hr.), Auxiliary NO+NC contacts, indicating lamps, push buttons, control circuit and contactor coil protection through suitable SP MCB(C curve,10KA), power and control wiring with properly crimped lugs,Al Bus Bar with Colour coated heat shrinkage sleeves lighting arrangement etc complete with internal wiring, testing and commissioning as required. Panel enclosure, IP-55, fabricated from 18-gauge thick TATA/Essar make CRCA sheet, duly treated and powder coated (minimum 70 micron DFT), minimum size 900 × 600 × 300 mm, mounted on MS angle stand (35 × 35 × 5 mm) with four legs of 18\\" length, double door with inbuilt locking system. The legs shall be embedded in M-15 cement concrete platform of minimum 200 mm height above ground level, with base dimensions equal to or larger than the panel base size. The panel shall have a suitable front opening with glass window for installation and reading of energy meter (to be supplied by DISCOM). Suitable for operation on 415V AC supply, complete in all respects as per specifications and direction of Engineer-in-Charge.
98Upto 5 HP (DOL type)
99Above 5 HP and up to 10 HP (Star Delta type)
100Above 10 HP and up to 15 HP (Star Delta type)
101Above 15 HP and up to 20 HP (Star Delta type)
102Above 20 HP and up to 25 HP (Star Delta type)
103Above 20 HP and up to 30 HP (Star Delta type)
104Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
1051.5 KW (2.0 HP)
106Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
107Class PN 1.0
10880 mm dia
109100 mm dia
110Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes
11165 mm dia
11280 mm dia
113Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
1143 Core
115P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required
1162.5 Sq.mm 3 core flat
117Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
118MS pipe specials up to 600mm dia (withminimum 5mm thickness sheet) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57609436
AUTHORITY Government Departments
TENDER VALUE 1.50 Crore
LAST DATE 29-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Drilling Of Bore Hole By Dth/Rotary/Combination Rig Of 150 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube Well At Rural And Urban Scheme Under Jurisdiction Of Division Malpura Under Annual Rate Contract.
Basic Detail
Tender No SE PHED NIT NO 12/2026-27
Bidding Type Tender
Location
City Tonk
State Rajasthan
Key Dates
Publish Date 21 Sep 2026
Submission Date 29 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 1.50 Crore
Tender Fee 3000
EMD 3 Lakhs
Exemption Available
Document List
BOQ_1062340.xls
d2fbd3cd-96cf-4866-a85a-2a78029d0be9.html
NIT12150mmTWRCDivMalpura.pdf
Tendernotice_1 (75).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1062340.xls

html

d2fbd3cd-96cf-4866-a85a-2a78029d0be9.html

pdf

NIT12150mmTWRCDivMalpura.pdf

pdf

Tendernotice_1 (75).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders