Housing Urban and Rular Development Government Departments Closing in 1 days TDR #57607274

Tender For B.O.Q For Construction Of Doctors Residential Quarters At Sdh Sopore B.W.O Electric Work

Issued by Government Departments · Baramulla, Jammu and Kashmir
Tender Value
20 Lakhs
Estimated cost
Bid Submission
16 Oct 2026
1 days left
EMD
40009
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Construction Of Doctors Residential Quarters At Sdh Sopore B.W.O Electric Work

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Oct-2026 Corrigendum Date 16-Oct-2026

BOQ

Name of Work:- B.O.Q for Construction of Doctors Residential Quarters at SDH Sopore B.W.O Electric work
Sl. No. Item Description
1Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells Lifeguard/Polycab Green/AnchorFireguard/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & items shall be approved before execution of work by SDO.
2Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work by SDO.
3Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Polycab Green/Anchor Fireguard/Eq. Make)
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified /Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make& shall be approved before execution of work by SDO.
5Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Polycab Green/Anchor Fireguard/Eq. Make)
6Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work.
7Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells Lifeguard/Polycab Green/Anchor Fireguard/Eq. Make) & shall be approved before execution of work (Including Cost of Conduit/Channel)
82x16 Sq.mm + 1 x 6 Sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
92x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
102x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/ Sub main in One run from Main Panel to Distribution Boards.
112x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter Sub-main in One run from Main Panel to Distribution Boards.
122x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for circuit wire
13Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB DB Complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq. Make)
14Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Havells/ABB/Eq Make)
1540Amp.
1663Amp.
1732 Amp
18Supplying and Fixing of MCB 6 way (4 + 18), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make)
19Supply/Installation/Testing and Commissioning of 18W + LED Conceal (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Jaquar/Eq Make as approved by SDO.
20Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
21Supply/Installation/Testing & Commissioning of 10W LED Mirror Light/Bed light of Havells/Wipro/Halonix/Philips/ Eq.Make as duly fitted on walls including making of necessary Connections & sample shall be approved by EIC.
22Supplying and fixing of AC / DC Bells with its Batteries
23Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Anchor/Crompton Greaves/EqMake.(Minium 1-Star)
24Supply/Laying/Connecting and Commissioning of 70 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
25Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 200 Amp-4-Pole ,36kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No. b) 300 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 40-Amp DP MCB = 06 No. as per site requirement)(b) 63-Amp DP MCB = 06 No. as per site requirement)(c) 32 Amp DP MCB = 06 No. as per site requirement)
26ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
27Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Polycab/Eq. Make.(Min 1-Star) as directed by SDO
28Supplying, Installation, Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified
29Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires
30Supply and fixing of PVC ceiling rose (2/3 pin), ISI marked, suitable for connection of light/fan point, complete with necessary accessories, including connections and testing as required of Havells/Anchor/Legrand/Eq.make
31Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, screws, washers, spacers etc., including finishing and making good the surface, complete as required
32Supply/Installation/Testing/Commissioning of Inverter 1150VA/12 V Pure Sinewave Inverter With Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 01 No. of 180Ah,12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc /Luminious/EXIDE /AMRON/Eq. Make
33Supply/Installation/Testing and Commissioning of 200 Amp Four Pole manual bypass changeover switch of Havells / Siemens/ ABB /Schinder /L&T/Eq make to switch between Generator Supply and Main Supply Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57607274
AUTHORITY Government Departments
TENDER VALUE 20 Lakhs
LAST DATE 16-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Construction Of Doctors Residential Quarters At Sdh Sopore B.W.O Electric Work
Basic Detail
Tender No NIT No.Fresh/165//2026-27 Dt 19/09/2026
Bidding Type Tender
Location
City Baramulla
State Jammu and Kashmir
Key Dates
Publish Date 06 Oct 2026
Submission Date 16 Oct 2026
Open Date 17 Oct 2026
Finance
Tender Value 20 Lakhs
Tender Fee 800
EMD 40009
Exemption Not Available
Document List
BOQ_1098846.xls
ebe01dcd-b244-44a4-9926-7311d8df733b.html
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Oct 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Oct 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1098846.xls

html

ebe01dcd-b244-44a4-9926-7311d8df733b.html

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender