Banking and Finance Government Departments Closing in 9 days TDR #57602668

Bids Are invited for Vrf Ac For Canara Bank Pune Circle Office

Issued by Government Departments · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Oct 2026
9 days left
EMD
40000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
1597

Project Description

Bids Are invited for Sitc Vrf Outdoor Unit Of 12 Hp Capacity - Supply, Transportation, Testing And Commissioning Of 12 Hp (Side Dischrge Cooling Only) Aircooled Type Vrv/Vrf Minimum Of One/Two/Three/Four Outdoor Units Comprising Of Dc Scroll/Dc Twin Rotary, Inverter Driven Compressor, Air Cooled Condenser Operation On 410A Refrigerant Gas And On 415V, 50Hz, 3 Phase Ac Supply. The Multiple Compressors Offered Shall Have Independent Refrigerant Circuit, Also Shall Cut Off Automatically In Part Load Condition. The Unit Shall Have Microprocessor Controls. The Out Door Units Shall Be Installed On The Space Alloted In The Drawings And Scope Shall Include All Supports For The Out Door Units. Units Shall Be Factory Assembled And Only The Refrigerant Piping Shall Be Carriedout At The Site. The Noise Levels For The Out Door Unit Shall Be Less Than 70Db(A). The Price Shall Include The Vibration Isolator, All Types Of Outdoor Units Connection Piping (T- Shape And Y-Shape) Kits, Required Number Of Outdoor Refnurt Joints, In Pair Excluding Refrigerant Pipe And Refregirent Gas For The Mentioned Capacity. , Sitc Vrf Outdoor Unit Of 18 Hp Capacity - Supply, Transportation, Testing And Commissioning Of 18 Hp (Top Dischrge Cooling Only) Aircooled Type Vrv/Vrf Minimum Of One/Two/Three/Four Outdoor Units Comprising Of Dc Scroll/Dc Twin Rotary, Inverter Driven Compressor, Air Cooled Condenser Operation On 410A Refrigerant Gas And On 415V, 50Hz, 3 Phase Ac Supply. The Multiple Compressors Offered Shall Have Independent Refrigerant Circuit, Also Shall Cut Off Automatically In Part Load Condition. The Unit Shall Have Microprocessor Controls. The Out Door Units Shall Be Installed On The Space Alloted In The Drawings And Scope Shall Include All Supports For The Out Door Units. Units Shall Be Factory Assembled And Only The Refrigerant Piping Shall Be Carriedout At The Site. The Noise Levels For The Out Door Unit Shall Be Less Than 70Db(A). The Price Shall Include The Vibration Isolator, All Types Of Outdoor Units Connection Piping (T- Shape And Y-Shape) Kits, Required Number Of Outdoor Refnurt Joints, In Pair Excluding Refrigerant Pipe And Refregirent Gas For The Mentioned Capacity. , Sitc Of Vrf Indoor Units - Supply Of 1.30 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 1.67 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 2.10 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 2.67 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 0.80 Tr Round Flow Compact Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 1.67 Tr One Way Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Supply Of Individual Cassette Unit - Supply Of 2.0 Tr Cassette Type Ac Unit With Copper Evaporator Coil Having 4 Way Round Air Flow Including All Necessary Fittings And Mountings As Specified By The Manufacturer. Min. 3 Star Or Equivalent Energy Saving Latest Model Inverter Type Of Toshiba, Mitsubhishi, Hitachi, Daikin, Lg, Bluestar, Carrier, Voltas With Cordless Remote Controller With 9 Mm Thick Nitrile Rubber Pipe Insulation With Fan And Fan Motor, Machine Control Panel Improved Refrigerant Joints. , Lifting And Shifting Of Outdoor Unit - Lifting, Shifting, Positioning And Installation Of 12Hp Vrf Outdoor Units From Ground Floor To Terrace Of Building (G+4) Or To The Desired Location As Directed By Employer , Lifting And Shifting Of Outdoor Unit - Lifting, Shifting, Positioning And Installation Of 18Hp Vrf Outdoor Units From Ground Floor To Terrace Of Building (G+4) Or To The Desired Location As Directed By Employer , Lifting And Shifting Of Vrf Indoor Units - Lifting, Shifting, Positioning Of Indoor Units As Mentioned Above Suitable For Vrv/Vrf System, From Ground Level To The Desired Location On The Required Floor Of The Building And Their Installation, Testing And Commissioning Including Providing Necessary Y Joints , Control Cabling - Supply And Installation Of Control Cabling With Copper Conductor Cable (2 Core 0.75 Sqmm ) With End Termination For Indoor Units

BOQ

Sl. No. Item TitleItem Description
1SITC VRF Outdoor Unit of 12 HP CapacitySupply, Transportation, Testing and Commissioning of 12 HP (Side Dischrge Cooling only) Aircooled type VRV/VRF minimum of one/Two/Three/Four Outdoor units comprising of DC scroll/DC Twin Rotary, Inverter driven compressor, Air cooled condenser operation on 410A Refrigerant gas and on 415V, 50Hz, 3 phase AC supply. The multiple compressors offered shall have independent refrigerant circuit, also shall cut off automatically in part load condition. The unit shall have microprocessor controls. The out door units shall be installed on the space alloted in the drawings and scope shall include all supports for the out door units. Units shall be factory assembled and only the refrigerant piping shall be carriedout at the site. The noise levels for the out door unit shall be less than 70db(A). The price shall include the vibration isolator, all types of outdoor units connection piping (T- Shape and Y-shape) kits, required number of outdoor Refnurt joints, in pair excluding refrigerant pipe and refregirent gas for the mentioned capacity.
2SITC VRF Outdoor Unit of 18 HP CapacitySupply, Transportation, Testing and Commissioning of 18 HP (Top Dischrge Cooling only) Aircooled type VRV/VRF minimum of one/Two/Three/Four Outdoor units comprising of DC scroll/DC Twin Rotary, Inverter driven compressor, Air cooled condenser operation on 410A Refrigerant gas and on 415V, 50Hz, 3 phase AC supply. The multiple compressors offered shall have independent refrigerant circuit, also shall cut off automatically in part load condition. The unit shall have microprocessor controls. The out door units shall be installed on the space alloted in the drawings and scope shall include all supports for the out door units. Units shall be factory assembled and only the refrigerant piping shall be carriedout at the site. The noise levels for the out door unit shall be less than 70db(A). The price shall include the vibration isolator, all types of outdoor units connection piping (T- Shape and Y-shape) kits, required number of outdoor Refnurt joints, in pair excluding refrigerant pipe and refregirent gas for the mentioned capacity.
3SITC of VRF Indoor UnitsSupply of 1.30 TR Round Flow VRF CASSETTE UNIT type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with DX coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. Panel size should be not more than 950mm Square. The rate must include cost of providing wireless remote and required indoor Refnurt joints
4SITC of VRF Indoor UnitsSupply of 1.67 TR Round Flow VRF CASSETTE UNIT type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with DX coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. Panel size should be not more than 950mm Square. The rate must include cost of providing wireless remote and required indoor Refnurt joints
5SITC of VRF Indoor UnitsSupply of 2.10 TR Round Flow VRF CASSETTE UNIT type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with DX coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. Panel size should be not more than 950mm Square. The rate must include cost of providing wireless remote and required indoor Refnurt joints
6SITC of VRF Indoor UnitsSupply of 2.67 TR Round Flow VRF CASSETTE UNIT type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with DX coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. Panel size should be not more than 950mm Square. The rate must include cost of providing wireless remote and required indoor Refnurt joints
7SITC of VRF Indoor UnitsSupply of 0.80 TR Round Flow Compact VRF CASSETTE UNIT type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with DX coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. Panel size should be not more than 950mm Square. The rate must include cost of providing wireless remote and required indoor Refnurt joints
8SITC of VRF Indoor UnitsSupply of 1.67 TR One way Flow VRF CASSETTE UNIT type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with DX coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. Panel size should be not more than 950mm Square. The rate must include cost of providing wireless remote and required indoor Refnurt joints
9Supply of Individual Cassette UnitSupply of 2.0 TR Cassette type AC unit with copper evaporator coil having 4 way round air flow including all necessary fittings and mountings as specified by the manufacturer. Min. 3 star or Equivalent energy saving latest model Inverter Type of Toshiba, Mitsubhishi, Hitachi, Daikin, LG, Bluestar, Carrier, Voltas with cordless remote controller with 9 mm thick nitrile rubber pipe insulation with fan and fan motor, machine control panel improved Refrigerant Joints.
10Lifting and shifting of Outdoor unitLifting, Shifting, Positioning and Installation of 12HP VRF Outdoor units from Ground Floor to terrace of building (G+4) or to the desired location as directed by employer
11Lifting and shifting of Outdoor unitLifting, Shifting, Positioning and Installation of 18HP VRF Outdoor units from Ground Floor to terrace of building (G+4) or to the desired location as directed by employer
12Lifting and Shifting of VRF Indoor unitsLifting, Shifting, Positioning of Indoor Units as mentioned above suitable for VRV/VRF System, from ground level to the desired location on the required floor of the building and their installation, testing and commissioning including providing necessary Y joints
13Control CablingSupply and installation of control cabling with copper conductor cable (2 core 0.75 sqmm ) with end termination for Indoor units

AI Tender Summary

OUR REF NO 57602668
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 10-10-2026
Authority
Authority Name Canara Bank
Work Description Bids Are invited for Sitc Vrf Outdoor Unit Of 12 Hp Capacity - Supply, Transportation, Testing And Commissioning Of 12 Hp (Side Dischrge Cooling Only) Aircooled Type Vrv/Vrf Minimum Of One/Two/Three/Four Outdoor Units Comprising Of Dc Scroll/Dc Twin Rotary, Inverter Driven Compressor, Air Cooled Condenser Operation On 410A Refrigerant Gas And On 415V, 50Hz, 3 Phase Ac Supply. The Multiple Compressors Offered Shall Have Independent Refrigerant Circuit, Also Shall Cut Off Automatically In Part Load Condition. The Unit Shall Have Microprocessor Controls. The Out Door Units Shall Be Installed On The Space Alloted In The Drawings And Scope Shall Include All Supports For The Out Door Units. Units Shall Be Factory Assembled And Only The Refrigerant Piping Shall Be Carriedout At The Site. The Noise Levels For The Out Door Unit Shall Be Less Than 70Db(A). The Price Shall Include The Vibration Isolator, All Types Of Outdoor Units Connection Piping (T- Shape And Y-Shape) Kits, Required Number Of Outdoor Refnurt Joints, In Pair Excluding Refrigerant Pipe And Refregirent Gas For The Mentioned Capacity. , Sitc Vrf Outdoor Unit Of 18 Hp Capacity - Supply, Transportation, Testing And Commissioning Of 18 Hp (Top Dischrge Cooling Only) Aircooled Type Vrv/Vrf Minimum Of One/Two/Three/Four Outdoor Units Comprising Of Dc Scroll/Dc Twin Rotary, Inverter Driven Compressor, Air Cooled Condenser Operation On 410A Refrigerant Gas And On 415V, 50Hz, 3 Phase Ac Supply. The Multiple Compressors Offered Shall Have Independent Refrigerant Circuit, Also Shall Cut Off Automatically In Part Load Condition. The Unit Shall Have Microprocessor Controls. The Out Door Units Shall Be Installed On The Space Alloted In The Drawings And Scope Shall Include All Supports For The Out Door Units. Units Shall Be Factory Assembled And Only The Refrigerant Piping Shall Be Carriedout At The Site. The Noise Levels For The Out Door Unit Shall Be Less Than 70Db(A). The Price Shall Include The Vibration Isolator, All Types Of Outdoor Units Connection Piping (T- Shape And Y-Shape) Kits, Required Number Of Outdoor Refnurt Joints, In Pair Excluding Refrigerant Pipe And Refregirent Gas For The Mentioned Capacity. , Sitc Of Vrf Indoor Units - Supply Of 1.30 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 1.67 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 2.10 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 2.67 Tr Round Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 0.80 Tr Round Flow Compact Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Sitc Of Vrf Indoor Units - Supply Of 1.67 Tr One Way Flow Vrf Cassette Unit Type Indoor Units Comprising With Pre-Filter, Fan Section With Low Noise Fan 3/4 Multi Speed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Water Lift-Up Mechanism, Insulation, Pipe Connections Etc. Of Various Capacities As Per Specifications And Drawings. Panel Size Should Be Not More Than 950Mm Square. The Rate Must Include Cost Of Providing Wireless Remote And Required Indoor Refnurt Joints , Supply Of Individual Cassette Unit - Supply Of 2.0 Tr Cassette Type Ac Unit With Copper Evaporator Coil Having 4 Way Round Air Flow Including All Necessary Fittings And Mountings As Specified By The Manufacturer. Min. 3 Star Or Equivalent Energy Saving Latest Model Inverter Type Of Toshiba, Mitsubhishi, Hitachi, Daikin, Lg, Bluestar, Carrier, Voltas With Cordless Remote Controller With 9 Mm Thick Nitrile Rubber Pipe Insulation With Fan And Fan Motor, Machine Control Panel Improved Refrigerant Joints. , Lifting And Shifting Of Outdoor Unit - Lifting, Shifting, Positioning And Installation Of 12Hp Vrf Outdoor Units From Ground Floor To Terrace Of Building (G+4) Or To The Desired Location As Directed By Employer , Lifting And Shifting Of Outdoor Unit - Lifting, Shifting, Positioning And Installation Of 18Hp Vrf Outdoor Units From Ground Floor To Terrace Of Building (G+4) Or To The Desired Location As Directed By Employer , Lifting And Shifting Of Vrf Indoor Units - Lifting, Shifting, Positioning Of Indoor Units As Mentioned Above Suitable For Vrv/Vrf System, From Ground Level To The Desired Location On The Required Floor Of The Building And Their Installation, Testing And Commissioning Including Providing Necessary Y Joints , Control Cabling - Supply And Installation Of Control Cabling With Copper Conductor Cable (2 Core 0.75 Sqmm ) With End Termination For Indoor Units
Basic Detail
Tender No GEM/2026/B/8059483
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 19 Sep 2026
Submission Date 10 Oct 2026
Open Date 11 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 40000
Exemption Not Available
Document List
14219f29-3c25-465a-a7d4-359ca80439df.pdf
boq_-_ac_works_-_co_pune_2026-09-19-16-49-28_a2258e8cfd6959c5a1643fd9fcc55555.pdf
9919101_Boq_1.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

14219f29-3c25-465a-a7d4-359ca80439df.pdf

pdf

boq_-_ac_works_-_co_pune_2026-09-19-16-49-28_a2258e8cfd6959c5a1643fd9fcc55555.pdf

xlsx

9919101_Boq_1.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders