Tender For Additional And Alteration To Lt Disrtibution And Associated Works At Dilbagh Enclave At Af Stn Halwara
Tender Value
43.65 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
8 days left
EMD
87300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ludhiana → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Additional And Alteration To Lt Disrtibution And Associated Works At Dilbagh Enclave At Af Stn Halwara
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old unserviceable LT cable of any Size, complete all as specified and directed. |
| 2 | Dismantling old unserviceable ACSR conductor from LT pole without disturbing the street lights and brackets of any Size, complete all as specified and directed. |
| 3 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as specified and directed. |
| 4 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as specified and directed. |
| 5 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core, complete all as specified and directed. |
| 6 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified and directed. |
| 7 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core, complete all as specified and directed.Note for item No 3 to 7:(i) Factory test of the cable shall be carried out in presence of the rep of accepting officer as detailed by Accepting Officer and contractor is required to submit purchase vouchers, e-way bill and manufacturer's test certificates while claiming payment of LT cables. The contractor will arrange the testing at factory premises and cost of the same is deemed to be included in the rates quoted. |
| 8 | M&L twin core 2.5 Sqmm size copper cable circular type, 1100V grade heavy duty cable, complete all as specified and directed. |
| 9 | M&L 40 mm bore, GI tubing, light grade as in cable protection pipe including all fittings, complete all as specified and directed. |
| 10 | M&L for boring under road/path/hard standing to pass the LT UG cables upto 80mm dia pipe with the own arrangement of T&P, complete all as specified and directed. |
| 11 | Supply, installation, testing and commissioning of CPRI approved LT pannels cubical outdoor type weather and vermin proof made out of 3.15 mm thick CRCA sheet of suitable size with front and rear opening and locking arrangement epoxy powder coated having colour siemens grey 200 Amps capacity Copper bus bar for phase 3 Nos and 1 No 100 amps bus bar for neutral mounted on epoxy insulator necessary copper control capacity control wiring heat shrinkable RYB coloured sleaves over bus bar for identification floor mounting angle iron base earth shields circular holes at bottom/top to receive incoming and outgoing cable. cable lugs, cable gland of size as required pannel suitable for the following control/filments sensible for 3 phase 50Hz 415V system complete comprising the following and including necessary PCC (1:2:4) Type B-1 using 20mm graded stone aggregate with 2 coat of cement base paint work for mounting of pannel as under :- (a) 4 Nos bus bar high conductivity copper strips proper insulated for phase (RYB) with 200 Amps & neutral rating 100 amps and mounting on porcelain support.- 01 Set INCOMER: 125 Amp, 4 pole MCCB, 16 KA- 01 No,Digital VAF meter with inbuilt selector switch & CT Coil - 01 NoSet of LED type indicating lamps - 01 No OUTGOINGS:63 Amp, MCCB 16 KA 415 V - 4 Nos. |
| 12 | Supply, install, testing and commissioning of LT panel board as per IS 8632, made out of 3.15mm thick CRCA sheet, outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with cement plaster in cement mortar 1:4 with 2 coats of cement base paint and comprising of the following switchgear, accessories are as under :-(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 400 Amp fixed on PVC heat shrinkable insulator heavy duty.(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos(e) MCCB 3 phase 415 Volts 4 pole 36 KA 400 Amp - 01 No (incoming)(f) MCCB 3 phase, 415 volts, 4 pole 16 KA, 125 Amp -05 Nos (outgoing) |
| 13 | Supply, install, testing and commissioning of LT panel board as per IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with cement plaster in cement mortar 1:4 with 2 coats of cement base paint and comprising of the following switchgear, accessories are as under :-(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 400 Amp fixed on PVC heat shrinkable insulator heavy duty.(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos(e) MCCB 3 phase 415 Volts 4 pole 36 KA 400 Amp - 01 No (incoming)(f) MCCB 3 phase, 415 volts, 4 pole 36 KA, 250 Amp -01 No (outgoing)(g) MCCB 3 phase, 415 volts, 4 pole 16 KA, 125 Amp -04 No (outgoing) |
| 14 | Supply, install, testing and commissioning of LT panel board as per IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with cement plaster in cement mortar 1:4 with 2 coats of cement base paint and comprising of the following switchgear, accessories are as under :-(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 300 Amp fixed on PVC heat shrinkable insulator heavy duty.(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos(e) MCCB 3 phase 415 Volts 4 pole 36 KA 250 Amp - 01 No (incoming)(f) MCCB 3 phase, 415 volts, 4 pole 16 KA, 125 Amp -03 No (outgoing) Please Enable Macros to View BoQ information |
| 15 | Supply, install, testing and commissioning of LT panel board as per IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with cement plaster in cement mortar 1:4 with 2 coats of cement base paint and comprising of the following switchgear, accessories are as under :-(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 300 Amp fixed on PVC heat shrinkable insulator heavy duty.(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos(e) MCCB 3 phase 415 Volts 4 pole 36 KA 250 Amp - 01 No (incoming)(f) MCCB 3 phase, 415 volts, 4 pole 16 KA, 125 Amp -03 No (outgoing) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender