Tender For Supply And Fixing Of Electrical Fittings Such As Wall Fan And Bollard Lighjt In The District Court Complex At Malkangiri
Tender Overview
Project Description
Tender for Supply And Fixing Of Electrical Fittings Such As Wall Fan And Bollard Lighjt In The District Court Complex At Malkangiri
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Sep-2026 | Cange date of Tender | Date | 29-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEI with 20 mm dia PVC non metallic heavy duty conduit FRLS type ISI marked Make-AKG/BEC/ Precision/Norpack/Polycab/Anchor 6A modular type ( flame retradant type) switch ISI marked Make-Schneider (Zencelo) /legrand( Myrius) /Panasonic (vision)/Anchor(Roma) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider (Zencelo) / legrand( Myrius) / Panasonic (vision)/Anchor(Roma) of suitable size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. Group-A. |
| 2 | Supplying,fixing of 6A Plug on the existing board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider (Zencelo) / legrand( Myrius) /Panasonic (vision)/Anchor(Roma) |
| 3 | Recess wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZH insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed PVC conduit Heavy duty FRLS of mentioned size Make-AKG/BEC/ Precision/Norpack/Polycab/Anchor as required as per direction of Engg.-in-Charge. a) 2x1.5mm2 + 1x1.5mm2 |
| 4 | b) 2x2.5mm2 + 1x1.5mm2 |
| 5 | S/F of 450mm sweep Wall Fan.Make:Usha/ Bajaj/Havells/Crompton. |
| 6 | S/F. of 300mm Sweep Exhaust fan of ISI marked.(Make- Havells/ Crompton / Usha/Bajaj/Orient) |
| 7 | Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Make-K-LITE/Philips/ LT/ PANASONIC/ Havells/ Bajaj/ Crompton/Wipro |
| 8 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). |
| 9 | Supplying an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . |
| 10 | S/F. of 20Wt.,100lumens/watt efficacy Light emitting diode aluminiuum batten light fittings of Bajaj/Havells / Crompton/Philips/ Panasonic/ Halonix/Wipro |
| 11 | S/F of Street light- 90W,120 lm/w efficacy ,IK 08 new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 12 | S/F of 12V,400Watt DC Power Supply(SMPS) for illuminated signage board. |
| 13 | S/F of 2.5 MF Capacitor for Fan |
| 14 | S/F. of 5Step electronic Fan regulator of Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision)/Anchor(Roma) make. |
| 15 | Supplying and fixing 40/63Amps DP 240 volts MCB Make-LEGRAND/ Siemens/ Schneider /Equivalant model of Havells/C& S/ ABB/Hager/L&T in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 16 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hager/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender