Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #57595840

Tender For Repair/Replacement To Fire Fighting Equipments , Fire Alarm Panels, Electrical And Essential Repairs At Afac Under Age(I) Af Coimbatore

Issued by Statutory Bodies & Commissions/Committees · Coimbatore, Tamil Nadu
Tender Value
16 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
21 days left
EMD
32000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement To Fire Fighting Equipments , Fire Alarm Panels, Electrical And Essential Repairs At Afac Under Age(I) Af Coimbatore

BOQ

Name of Work:- REPAIR/REPLACEMENT TO FIRE FIGHTING EQUIPMENTS , FIRE ALARM PANELS, ELECTRICAL AND ESSENTIAL REPAIRS AT AFAC UNDER AGE(I) AF COIMBATORE
Sl. No. Item Description
1Meterial and labour for removing the smoke detectors/respose indicators/call point/loop driven sounder/fault isolater from below/above the false ceiling of any height, disconnect the electrical connection and cleaning the smoke detector,/respose indicators//call point/loop driven sounder/fault isolater checking on bench for its proper function, refixing the detectors with reconect the electrical connection with suitable size of nut bolt & washers in fall celing boards and ensure the cable connections etc all as directed
2Material and labour for repair/service/cleaning ,checking and callibaration of auto/manual operation fire fighting control panel with servicing of main/jockey pump starter, auto/manual operation and main Diesel pump operation with respect water pressure switch of pipe line, auto cut operation of jockey pump etc and ensure the proper functions of panel all as specified and directed. Note : (i) The cleaning materials, NO/NC contactors deemed to be included in quated rate
3Material and labour for removing the fire extinguser 4.5/6/9/50 Kg/ltr capacity from its position, transport to workshop & back ,refilling the chemicals,water,powder,CO2 etc as per extinguser required quantity as per safety norms with replacement of old stickers ,refixing its on same position, testing of extinguser after completion of refilling all as specified and directed
4(a) CO2 type 4.5 Kg
5(b) Foam/water type 9 Ltrs
6(c) Powder DPC type 6 Kg
7(d) Mechanical foam 50 Ltrs
8Material and labour for valve assembly with meter for DCP/CO2 ffire extinguser 4.5/6/9 Kg/ltr capacity including taking down unserviceable valve assembly and testing after completion all as directed
9Supply and fix sealed lead acid battery 12 volt 4.5 to 7 AH heavey duty suitable for fire alarm control panel including taking down unservuiceable power backup batteries all as directed Make - Exide, Tata, Amaron
10Supply and fix detector complying with certified EN 45 addressable type smoke detector photoelectric/optical with base with self built inteligence as per IS 11360 including taking down unserviceable detectors any type all as directed
11All as per item No.10 above but addressable type multi sensor detector with heat and smoke combination all as ditected
12Supply and fix remote response indicators including taking down unserviceable detectors all as directed
13Supply and fix short circuit isolaters including taking down unserviceable isolater all as directed
14Supply and fix addressable manual call point resettable type including taking down unserviceable call point all as directed
15Supply and fix fire alarm sounder/siren electronic type horizontal two stage continuoues operation for atleast 50 minits airth sound level 65 db to 120 db measured with sound output variation of +5db of distance 500 mtr range including taking down unserviceable sounder all as directed
16Supply and fix CP hose 15 meter legnth for fire fighting system including taking down unserviceable hose pipe all as directed
17Supply and fix hydrent landing valve single headed including taking down unserviceable landing valve all as directed .
18Supply and fix Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short including taking down unserviceable branch pipe all as directed ..
19Supply and fix in replacement Hose reel drum 30m including taking down old hose real drum all as directed
20Supply and fix in replacement Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard for internal /external location all as specified and as directed.
21Supply and fix sprinkler head glass bulb type standered response as per IS 15106 pendent type temperature range 68 degree including unserviceable sprinkler all as directed
22Supply and fix pressure switch universal type including taking out unserviceable switch all as directed
23Supply and fix flow switch 80 mm dia including taking out unserviceable switch all as directed
24Supply and fix flow switch 150 mm dia including taking out unserviceable switch all as directed
25Supply and fix butterfly valve 80 mm dia with necessary nut bolts washer, gaskets including taking down unserviceable valve in any situation/height, necessary welding/cutting where required and making good the surface with existing finish all as directed
26All as per item No 25 above but 150 mm dia butterfly valve complete
27All as per item No 25 above but 100 mm dia butterfly valve complete
28Material and labour for painting of steel/iron surfaces of pipes any description over 10 cm in width or girth with cleaning, preparation of old painted surfaces and two coat of Synthetic enamel fire red paint of stand post rising pipes in any postion/height including standards. braces, rails. stays etc over a coat of red oxide primer all as specified and as directed.
29Material and labour for fire alarm panel servicing, configaration, testing for proper function, alarm location indication, interconnection of repeter panel, dial and speach option of panel etc for of 4 loop with three cards fire alarm panel minimum 190 detectors per card, rectification of defects at any situation zone to zone vise all as directed
30Supply and fix in replacement gun metal gate valve heavy duly ISI marked with iron wheel head screwed both ends for iron pipes 25 mm bore dia including taking down unserviceable valve all as directed .
31Supply, layig, connecting, testing and commissioning of 1.5 Sqmm 2 core multistanded PVC insulated copper conductor heavy duty electric cable conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe/conduit, duct or along the pole and including the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, bottle type lugs etc including taking down unserviceable cable all as specified and directed. Make: Havells/Polycab/Finolex/ Paragon/Gloster/Nicco
32Material and labour for leak rectification in any size of fire fighting pipe line in any situation and height including necessary cutting/welding in MS pipeline, making good as per existing finish, necessary earth work were require at site all as directed
33Supply and fix in MCCB 4 Pole, 415V, adjustable type, 160 Amps with Breaking Capacity 36 KA of existing frame including taking down unserviceable MCCB all as specified and as directed. Make L&T, Havells, ABB, C&S
34Supply and fix in MCCB 4 Pole, 415V, adjustable type, 200 Amps with Breaking Capacity 36 KA of existing frame including taking down unserviceable MCCBall as specified and as directed. Make L&T, Havells, ABB, C&S
35Material and labour for Sub main wiring by surface/ in any situation complete with 2 runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20/25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface in wall/Ceiling etc from Main DB to sub DB /pole all as specified and as directed by engr - in- charge. Note :- 2 runs of 1.5 sqmm, + 1 run of 1.5 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
36Mterail and labour for taking down old cross flow fills from cooling radiator of 3 Nos and removing separtely with dismanteling of holdfast pipes in top and bottom mounting and removing of old fills from mounting frame approx 90 Nos, fixing of new fills of size 600 x 1450 x 0.33 mm thick black colour PVC sheets in pipe holdfast and refixing the same in cololing radiator with proper nut bolts/washers etc and check the water flow from top to bottom of fills and old unserviceable PVc fills removing from site and disposed off including draining the water and cleaning all dirt and dust with clearn water and removing the dirts/silt/residue materials from bottom tank all as directed. by Engr-in-Charge. Note: a) Cleaning chemical rate/T&P charges deemed to be included in quated rate. b) T&P required shall be brought by contractor at no extra cost.
37Supply and fix Y strainer type (foot valve) for suction of size 150 mm including takig down unserviceable complete strainer all as directed
38Supply and fix Y strainer filter for suction of size 150 mm including opening of Y stainer filter housing and takig down unserviceable strainer filter insert the new filter on housing and refixing the top cover all as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57595840
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 16 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement To Fire Fighting Equipments , Fire Alarm Panels, Electrical And Essential Repairs At Afac Under Age(I) Af Coimbatore
Basic Detail
Tender No 8193_E8
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 19 Sep 2026
Submission Date 12 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 16 Lakhs
Tender Fee 500
EMD 32000
Exemption Available
Document List
475ba834-17d6-4dba-b9fb-ee08a5e2fd41.html
BOQ_885848.xls
credit_exc.pdf
General_pages_.pdf
PS_.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

475ba834-17d6-4dba-b9fb-ee08a5e2fd41.html

xls

BOQ_885848.xls

pdf

credit_exc.pdf

pdf

General_pages_.pdf

pdf

PS_.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail