Tender For Addition/Alteration To Officers Institute At Afs Phalodi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
09 Oct 2026
13 days left
EMD
88340
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition/Alteration To Officers Institute At Afs Phalodi
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer, Air Force Station, Phalodi Name of Work : ADDN/ALTN TO OFFICER'S INSTITUTE AT AFS PHALODI Contract No: GE (AF) PHALODI/ OF 2026-27 Serial Page No. Bidder Name : SCHEDULE 'A'(BOQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT TEXT # NUMBER TEXT NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER NUMBER # TEXT Srl.No. Item Description Item Code / Make Approx No of Units reqd Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 3 | Taking down chowkats or frames with shutters (without taking off shutters from frames) exc. 1.5 sqm but n. exc 4 sqm each complete all as specified and directed. |
| 4 | Taking down shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. |
| 5 | Demolition of reinforced Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and disposed off from site complete all as specified and directed. |
| 6 | Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 7 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. Note:- Any excavation in SDR/Loose soil /PCC/Hardstanding/ Interlocking tiles/Bituminous pavement shall be carried out by manual mode only irrespective of Tech/Residential area. In case of mechanical excavation engaged by the contractor, any fault due to rupturing of communication/power/any other utility lines shall be rectified by appropriate joint as per direction of Engr-in-Charge/GE/Stn Auth as deemed fit and no extra cost will be paid in this respect. |
| 8 | Excavating over areas, exc 1.5 m and n.exc 3.00 deep and getting out in soft/loose soil complete all as specified and directed. Note:- Any excavation in SDR/Loose soil /PCC/Hardstanding/ Interlocking tiles/Bituminous pavement shall be carried out by manual mode only irrespective of Tech/Residential area. In case of mechanical excavation engaged by the contractor, any fault due to rupturing of communication/power/any other utility lines shall be rectified by appropriate joint as per direction of Engr-in-Charge/GE/Stn Auth as deemed fit and no extra cost will be paid in this respect. |
| 9 | Returning filling in with approved excated soil including spreading, levelling in layers not exc 25cm thick complete all as specified and directed. |
| 10 | Removing excavated material (soil) to a distance exc. 1.50 km but n exc. 5 km and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 11 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 12 | Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Rough finished surfaces of concrete flat complete all as specified and directed. |
| 13 | Formwork to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and directed. |
| 14 | Use and waste of formwork to sides and soffits of floor or roof beams , lintels, cintilevers, shelves for flat surfaces complete all as specified and directed. |
| 15 | M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed. |
| 16 | All as per item No 14 herein before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 17 | M&L Reinforced cement concrete (nominal mix) in Type B1 1:11/2:3 using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 18 | M&L Reinforced cement concrete (nominal mix) in Type B1 (1:11/2:3) using 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 19 | M&L Reinforced cement concrete (nominal mix) in Type B1 (1:11/2:3) using 20 mm graded aggregate in Beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and directed. |
| 20 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and directed. |
| 21 | M&L Reinforced cement concrete (nominal mix) in Type B1 (1:11/2:3) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 22 | S&F WPC fluted wall panelling of 15mm thick with and including frame work for fixing fluted wall panelling to wall complete as per manufacturers instructions and complete all as specified and directed. Note: Pattern/colour of fluted wall panel to be approved by GE. |
| 23 | M&L Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595mm x 595 mm with Semi perforated 12mm thick micro tegular edged of approved texture, design and patterns having moisture less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600mmx 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85mmx25mmx2mm. Galvanised iron perimeter wall angle of size 24mmx 24mmx0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and complete all as specified and directed. Page Note: Pattern/design/colour of ceiling to be approved by GE. |
| 24 | S&F mild steel work in tubular trusses, purlins, post, distance pieces including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 grade St-240 complete all as specified and directed. |
| 25 | S&F S&F mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde- E- 250) quality-A complete all as specified and directed. |
| 26 | S&F Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30 cm long of diameter of neck 20 mm complete all as specified and directed. |
| 27 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 28 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 29 | M&L for preperation of new steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed. |
| 30 | Earth filling under floor, spreading and levelling in layers not exceeding 25cm thick and well ramming including watering as required complete all as specified and directed. |
| 31 | Treating the backfill in contact with foundation @ 7.5 litres of emulsion / Sqm of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed. |
| 32 | Treating the top surface of filled earth @ 5 litres of emulsion / Sqm of surface complete all as specified and directed. |
| 33 | Treating the soil along with external perimeter of building @ 2.25 litre of emulsion / m of the perimeter wall complete all as specified and directed. |
| 34 | Hard core of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed. |
| 35 | M&L 100mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as sub base under flooring complete all as specified and directed. |
| 36 | M&L for Pre-cast cement concrete block masonry type C1 (1:3:6) (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. |
| 37 | M&L rendering 10mm thick in CM (1:6) on fair faces of brick or concrete surfaces finished even & smooth w/o using extra cement complete all as specified and directed. |
| 38 | M&L for 15mm thick rendering in two layers of 10mm thick and 5mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even & smooth w/o using extra cement, using water proofing compound in top layer complete all as specified and as directed. (WPC shall be measured and paid separately as \\"Supply only\\".) |
| 39 | Supply only integral water proofing compound of approved quality complete all as specified. |
| 40 | M&L for 25 mm thick PCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in leveling course complete all as specified and directed. |
| 41 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishing complete over 20 mm thick cement screed bed in CM 1:6,complete all as specified and directed. |
| 42 | M&L for machine cut kota stone slab 20-25mm thick in skirting, risers of steps, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 15 mm thick cement plaster in CM (1:4) complete all as specified and directed. |
| 43 | S&F 12mm Toughned glass as in hinged doors, partitions automatic doors/windows and similar work including cutting to shape, drilling holes required including necessary joining cleats, glazing clips, rubber packing,etc gaps filling with silicon complete all as specified and directed. |
| 44 | S&F solar control film 50 micron reflective type exc 1.50 sqm, sticked to glass panes as per instruction of manufactures complete all as specified and directed. |
| 45 | M&Lfor 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 46 | M&L for Preparation of new plastered surfaces and applying two coat of oil bound distemper over a coat of primer with 3mm thick wall care putty to achieve smooth finish on internal surfaces of walls complete all as specified and directed. |
| 47 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 48 | Complete removal of exisisting treatment on walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 49 | Complete removal of exisisting treatment on walls and applying two coat of oil bound distemper over a coat of primer with 3mm thick wall putty to achieve smooth finish complete all as specified and directed. |
| 50 | Complete removal of exisisting treatment on ceiling and applying two coat of oil bound distemper over a coat of primer with 1.5mm thick putty to achieve smooth finish on ceiling surfaces complete all as specified and directed. |
| 51 | M&L for 75 mm thick PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) as in plinth protection, paving, surface finished even and smooth without using extra cement, laid in panels n exc 3 mtr long and joints shall be filled with the mixture of bitumen and sand in (1:3) by weight, complete all as specified and directed. |
| 52 | S&F wall mounted 6mm thick bevelled edge mirror of selected quality glass, and fixed to heavy duty mirrior clips with chromium plated brass screws and cup washers fixing complete all as specified and directed. |
| 53 | M&L for anodised aluminium powder coated of any colour frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 54 | S&F for anodised aluminium window and ventilator shutters, powder coating of any colour (Thickness or powder coating not less than 50 micron) side hung/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 55 | S&F Sheet glass 5.5mm thick ordinary quality and glazing with beading in squares exc 0.5 Sq.m in each pane complete all as specified and directed. |
| 56 | M&L One light point controlled by one way switch wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards/ existing sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed. |
| 57 | M&L One fan point controlled by one way switch wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards/ existing sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed. |
| 58 | M&L One 3 pin 6 Amp socket point outlet on the same board with other switches wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards/ existing sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed. |
| 59 | M&L One 3 pin 6 Amp socket point outlet on the independent board wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards/ existing sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed. |
| 60 | All as per item No 55 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed. |
| 61 | S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board complete all as specified and directed. |
| 62 | S&F modular Socket, 6A - 2/3 pin combined 2 module 230 volt in grey colour complete all as specified and directed. |
| 63 | S&F modular Socket 6A/16A - 2/3 pin combined 2 module 230 volt in grey colour complete all as specified and directed. |
| 64 | S&F modular switch 1 way 6 Amps 1module 230 volt grade in grey colour complete all as specified and directed. |
| 65 | S&F modular switch 1 way 16 Amps 1module 230 volt grade in grey colour complete all as specified and directed. |
| 66 | S & F Modular Fan step regulator, 120W - 1/2 module complete all as specified and directed. |
| 67 | S & F white cover plate with frame,2 module complete all as specified and directed. |
| 68 | S & F white cover plate with frame,6 module complete all as specified and directed. |
| 69 | S & F white cover plate with frame,8 module complete all as specified and directed. |
| 70 | S & F white cover plate with frame,3 module complete all as specified and directed. |
| 71 | S & F Metal flush box 2 module complete all as specified and directed. |
| 72 | S & F Metal flush box 8 module complete all as specified and directed. |
| 73 | S & F Metal flush box 3 module complete all as specified and directed. |
| 74 | S & F Metal flush box 6 module complete all as specified and directed. |
| 75 | S&F Vertical TPN distribution boards, 6 way (18 slots for SP MCB), double door, IP54, as per IS 8623-III, impact resistance IK09 with the provision of 125 Amps MCCB 4 pole, as incomer, 200 A rated busbar, blanking plates, with all electrical connection complete all as specified and directed. |
| 76 | Supply and fix of MCCB FP 125 Amps Conforms to IS/IEC 60947-2 , 36kA breaking capacity, Ics= 100% of Icu*,Adjustable overload settings: 0.8 - 1.0 x In, Fixed short-circuit settings: 10 x In, Compact size (compatible to VTPN), complete all as specified and directed. |
| 77 | S&F of triple pole & neutral DB, 4 way (double door), conforming to IEC 61439- 3, suitable for flush mounting with 100 A insulated & shrouded copper busbar for each phase, 2 fully insulated & shrouded neutral bar, 2 earth bar, wire set and cable ties for cable management, IP 43 & IK 09 protection with reversible metal door with provision for 4 Pole MCB as incomer and TP/SP MCBs as outgoing, all complete as specified and directed. NOTES: (i) MCBs & MCCBs shall be measured and paid in separate items. |
| 78 | S&F of single pole & neutral 12 way DB (double door), conforming to IEC 61439- 3, suitable for flush mounting with 100 A insulated & shrouded copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set and cable ties for cable management, IP 43 & IK 09 protection with reversible metal door with provision for DP MCB as incomer and SP MCBs as outgoing, all complete as specified and directed. NOTES: (i) MCBs shall be measured and paid in separate items. |
| 79 | S&F of single pole & neutral 8 way DB (double door), conforming to IEC 61439- 3, suitable for flush mounting with 100 A insulated & shrouded copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set and cable ties for cable management, IP 43 & IK 09 protection with reversible metal door with provision for DP MCB as incomer and SP MCBs as outgoing, all complete as specified and directed. NOTES: (i) MCBs shall be measured and paid in separate items. |
| 80 | Supply and fix of heavy-duty 380V–415V IP44 splash-proof industrial plug and socket set 32A, 5-pin (3P+N+E) or 4-pin (3P+E), 3 phase, with 4 pole TPN 32 Amps enclosed in metal box concealed in wall suitable for 4 TR tower AC complete all as specified and directed. |
| 81 | Supply and fixing MCB TPN 440 Volts, 'B' series, breaking capacity 10 KA of rating 63-100 Amps complete all as specified and as directed. |
| 82 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Double poles (DP) and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning. complete all as specified and as directed. |
| 83 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles (SP) and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.complete all as specified and as directed. |
| 84 | S&F of 6 module surface mounted power unit with starter , MCB double pole & 16 to 25 Amp heavy duty plug top suitable for AC complete all as specified and directed. |
| 85 | M&L for Concealed Sub main wiring with 4 runs of 10 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 10 Sqmm single core PVC insulated but unsheathed multistranded copper conductorFRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed.Note : Four runs of 10 Sqmm cable, one run of 10 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length. |
| 86 | M&L submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLSH copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc complete all as specified and directed. |
| 87 | M&L submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLSH copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc complete all as specified and directed. |
| 88 | S&F of double bracket decorative wall light ,twin candle style illumination, color copper, material glass, style art décor, Product dimension 16.1L x 27W x 27.5H Centimeters, 230Volt, bulb base E27 compatibility, wall mount, enclosure style glass, finish type matt, complete with fitting fixturescomplete all as specified and directed. |
| 89 | S & F Hexagon 8 Long Grid LED Garage Lighting ultra bright 6500 k 35000 lumen illumination,240v,durable aluminiumand polycarbonate fixture complete all as specified and directed. |
| 90 | S&F in replacement of building security light LED made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover seperate driver compartment with IP66 protection and impact resistance of IK08. High power LED as light source and electronic driver of capacity 35 watt complete with mounting bracket made of 25/32 mm dia GI pipe (not less than 550 mm long) bent to the shape at 120 degree angle complete with clamps & nuts, washers and bolts complete all as specified and directed Note :- Rate of this item includes cost of supply of bracket of 25/32 mm dia GI pipe. |
| 91 | S&F LED Recessed full lit luminaire with glare free uniform illumination 2 ft x 2 ft, 35/36 Watt , complete with all accessories internally pre-wired and including connecting to ceiling rose with three core flexible copper conductor cable of size 1Sqmm complete all as specified and directed. |
| 92 | Earthing complete with Galvanised steel earth plate electrode 600mm x 600mm x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC (1:2:4) using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5) will be measured separately under respective item complete all as specified and directed. |
| 93 | S&F ceiling fan 5 star,Led indication for speed,contemporary look,with remote, and timer mode of sweep 1400 mm of 28 Watt ,360 RPM, including all standard accessories complete all as specified and directed. |
| 94 | Shifting of Spilt AC System With indoor unit & Outdoor unit with Proper fixing, servicing & Gas Filling with connected Accessories complete all as specified and directed. |
| 95 | Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. |
| 96 | S & F of wall mounted outdoor metal bracket of size 36 inch of heavy duty of minimum weight 5.50 Kg and Load capacity of 50 kgs for outdoor unit of split AC's 1.5/2.0 TR capacity with & including connected accessories viz fastner, nuts and bolts complete all as specified and directed. |
| 97 | M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level) connected to galvanized earth lead wire of 4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 40 mm dia light grade GI tubing for protection of earth lead, MS sheet m etal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt necessary excavation, earth work, in soil/loose soil and disposal of soil to a distance not exc 15 Mtr and necessary connection and testing complete all as specified and directed. |
| 98 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall Split type Unitary Air conditioning complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (Closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 155V to 280V operating voltage with low & high voltage cutoff and 50 Hz, 1 Phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary/ twin rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Deg C. Min 10 years Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, Hermetic compressor IS 10617, Heat exchanger IS : 11329, Capacitor IS : 2993 and Motor IS : 12615 complete as per CPWD Specification and IS : 1391 Part II 2023. The system shall be able to operate up to 55 Deg C (Out door ambient temperature) complete all as specified and directed with following detailed specification:(i) Inverter type, Cooling only Model of Capacity 1.5 TR with BEE 5 Star Rating(ii) Evaporator and Condenser Coil Material: Copper(iii) Rated Cooling at 100% Capacity (Min-Max): 1320 Watt to 5810 Watt(iv) Rated Cooling at 50% Capacity: Minimum 2640 Watt(v) Rated Operating Current: 1.9 A to 9.5 A (vi) ISEER Energy Efficiency Rating: Min 5.60(vii) Noise level of Indoor Unit: 19-48 dB(viii) Indoor Air flow Range (Min-Max): 121 CFM to 806 CFM(ix) Moisture Removal Capacity: 0.6 l/h (x) Maximum Weight of Indoor Unit: 16 Kg(xi) Maximum Weight of Outdoor Unit: 31 Kg (xii) ODU to IDU control wiring (Copper): Minimum 1.5 Sqmm, 4 Core(xiii) Minimum additional refrigerant charge: 20 g/mMake: OGENERAL (IDU MODEL NO :ASGG18CEAC-B, ODU MODEL NO : AOGG18CEAC-B)/ MITSUBISHI (IDU MODEL NO : MSY - GZ13VF, ODU MODEL NO : MUY-GZ13VF)/ ANY OTHER EQUIVALENT MAKE AND MODEL CONFORMING TO IBID SPECIFICATION |
| 99 | Supply & Laying XLPE insulated armoured PVC Sheathed LT (1100 Volts grade) cable with aluminium conductor of size 70 Sqmm 3.5 core in trench on wall/roof or passing through GI pipes including all fixing arrangements complete all as specified and as directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 100 | Excavation in trenches n.exc 1.50m wide and n exc 1.50m in depth for foundation etc n.exc 10 sqm on plan and getting out in soft & loose soil. |
| 101 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 102 | Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed.[Note : Measurement will be done after punning] |
| 103 | M & L for PCC cable cover of Class LV, Type I, flat, size 250mm x 150mm x 40mm to be laid over dry sand cushioning in trenches as protection to cable all as specified and directed. |
| 104 | Material and labour for replacement of GI pipe 50 mm dia light grade for protection of LT Cable complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender