Tender For Special Repair To Building No P-95 (Md Accn) B Bn At Sunjuwan Under Ge Jammu.
Tender Value
34.94 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
6 days left
EMD
69880
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No P-95 (Md Accn) B Bn At Sunjuwan Under Ge Jammu.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-Sep-2026 | Corrigendum | BOQ | 09-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | B/R Portion: -Taking down chowkhats or frames with shutter without taking off shutters from the frame not exceeding 1.5 Sqm each including cutting holes for taking out hold fast or dismantling brick (holes cut and any other damage to jambs, wall for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt) complete all as specified and as directed. |
| 2 | Taking down chowkhats or frames with shutter without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each including cutting holes for taking out hold fast or dismantling brick (holes cut and any other damage to jambs, wall for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt) complete all as specified and as directed. |
| 3 | Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified and as directed. |
| 4 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and removing unserviceable material exceeding 100 mtr complete all as specified and as directed. |
| 5 | Demolition of brick masonry built in cement mortar including all quions, arches, pillars etc. complete all as specified and as directed. |
| 6 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including racking out joints hacking for key scrubbing with water etc complete all as specified and as directed. |
| 7 | Dismantling floors hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 8 | Dismantling of PVC, cast iron 100mm or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required complete all as specified and as directed. |
| 9 | Demolition of cement concrete (Reinforced cement concrete) in ground floors and pavings not exceeding 15 cm thickness (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. |
| 10 | Dismantling of PVC, cast iron 75 mm or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required complete all as specified and as directed. |
| 11 | Brick work of old size sub class ‘B’ bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 12 | Pressed steel frames for door (factory made) out of 1.25 mm thick black mild steel sheet, with one or more rebates including necessary fixing lugs, butt hinges, lock strike plate, etc. complete size of frame 105 x 60mm including bottom of each chowkhat to be welded with 2 No's 25 x 25 x 3 mm thick flat iron projecting 10 cm on either side including one shop coat of red oxide primer complete all as specified and as directed.Note: - PCC (1:3:6) type C-0 as in back fill will be paid separately. |
| 13 | Pressed steel frames for door (factory made) out of 1.25 mm thick black mild steel sheet, with one or more rebates including necessary fixing lugs, butt hinges, lock strike plate, etc. complete size of frame 125 x 60mm including bottom of each chowkhat to be welded with 2 No's 25 x 25 x 3 mm thick flat iron projecting 10 cm on either side including one shop coat of red oxide primer complete all as specified and as directed.Note: - PCC (1:3:6) type C-0 as in back fill will be paid separately. |
| 14 | Cement concrete (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) as in backfill of pressed steel door frames complete all as specified and as directed by the Engineer-in-Charge. |
| 15 | Solid PVC door frame and for cupboards of size 50mm x 47mm made out of 5mm PVC sheet and edges will be painted to match with printed sheet, reinforced with mild steel square tube supplying and fixing in opening as per specification complete all as specified and as directed. |
| 16 | 30 mm thick PVC factory made panel door shutter (style) consisting of frame made out of mild steel tubes for top and bottom rail, mild steel frame shall be covered with heat moulded wood grain printed PVC channel and 5 mm thick x 15 mm wide PVC sheet beading used inside style and rails and decorative PVC beading of 10 x 10 mm used instead of exposed portion of PVC sheet beading as in toilet/ kitchen cabinet shutters complete all as specified and as directed. |
| 17 | Taking down, easing and adjusting shutters of any description, exceeding 1.00 Sqm and not exceeding 2.00 Sqm each and refixing in the same opening complete all as specified and as directed. |
| 18 | 30mm thick flush shutters, soild core construction, with particle board core and plywood face panels, both faces are covered with decorative face veener with lipping/frame to match complete all as specified and as directed by Engineer-in-Charge. |
| 19 | 35 mm thick second class hard wood half glazed and Skelton shutters open rebated and prepared to receive glass/wire gauge etc. without sash bar but with lock rail edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass/wire mesh etc sizes of member as per clause 8.20 (a) of SSR part -I for door shutter complete all as specified and as directed. |
| 20 | Pressed steel cup board frame of mild steel sheet 1.25 mm thick size of frame 60 x 40mm with rebate of 20 mm wide and 12 mm deep including PCC (1:2:4) as in filling to back of chowkhats including butt hinges 100 mm long piano hinges measured separately complete all as specified and as directed. |
| 21 | 19 mm thick prelaminated MDF interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work as in cupboard shutters/ pelmet box and cupboard shelves including teak wood beading all around complete all as specified and as directed. |
| 22 | Supply and fixing in repair kitchen cabinet and CBs shutter with frame and shelves made of solid UPVC foam profile with homogenous fine cellular structure having smooth outlet integral skin having 45mm width and 18mm thickness as vertical and horizontal stiles, joints are made and shall be fixed to walls using required size sheet metal screw and solvent adhesive vertical and horizontal profile made of UPVC profile frame of size 35mm x 17mm. The panel shall be filled with accucell polank profile of size 250mm width and 6mm thick complete all as specified by manufacturer instructions and as directed. |
| 23 | Continuous piano hinges mild steel bright finish or electrogalvanised width of flap 30mm when open complete all as specified and as directed. |
| 24 | Magnet ball catches with 8mm dia steel ball and brass body and striking plate for cup board/ cabinet shutters complete all as specified and as directed. |
| 25 | Aluminium powder coated three track sliding type window, track section 92 x 31.5 x 1.50 mm having three track (18mm series section) (two of 4.8 mm thick glass and one of stainless steel wire cloth of 0.56 mm dia and 1.0 mm aperture) with members of window shutters of section 40 x 18mm including aluminium grill 75 mm x 5.50 mm thick pitch diamond shape, wire gauge and grill shall be fixed with the help of 40 mm aluminium flat and other standard Bombay sliding section including all necessary fiber wheel rollers suitable handle to facilitate sliding and all necessary jointing cleats glazing clips, rubber packing, Aluminium snap beading etc complete all as specified and as directed. |
| 26 | Reinforced cement concrete design mix M-25 (using 20 mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts shell roofs kitchen platform slabs article up to 5th floor level complete all as specified and as directed. |
| 27 | PCC (1:2:4) type B-1 (using (20 mm graded crushed stone aggregate) as in blocks for hold fasts, benching, coping apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.Note: - Form work required for these items included in the unit rate of this item. |
| 28 | Stainless steel butt hinges 100mm long medium weight cold rolled complete all as specified and as directed. |
| 29 | 100 mm long hasp and staple, aluminium anodised with bolt to hinge plate and fixed with screws complete all as specified and as directed. |
| 30 | Aluminium tower bolt of size 150 mm complete all as specified and as directed. |
| 31 | Aluminium handle of size 150 mm complete all as specified and as directed. |
| 32 | Aluminium handle of size 100 mm complete all as specified and as directed. |
| 33 | Mild steel helical/ ordinary rat tail rod pattern door spring 300 mm including roller and roller plate complete fixed with welding complete all as specified and as directed (ISI marked). |
| 34 | Small fittings second class hardwood such as brackets of any types latch and hinges blocks shaped door and window stops and the like, not exceeding 200 cu.cm each complete all as specified and as directed. |
| 35 | Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 36 | 25 mm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in floor finished rough complete all as specified and as directed. |
| 37 | Glazed ceramic tiles 300 x 450 x 7mm thick on vertical surface such as in skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile not exceeding 0.18 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 39 | Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 40 | Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) in vertical surface such as skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 41 | Demolition of stone slabs any description or thickness in floors laid, bedded and pinned in cement mortar complete all as specified and as directed. |
| 42 | Granite (of any type) 16-20mm thick (tabled rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in colour cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cement mortar (1:6) edges of slab to be rounded from all sides (including cutting, wastage and polishing) complete all as specified and as directed. |
| 43 | Rounding to edges of stone slabs Granite, Kota etc one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed. |
| 44 | Machine cut kota stone slab flooring 20-25 mm thick in one piece as in treads laid over cement screed base 20mm thick in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting as required, rubbing and mirror polishing complete all as specified and as directed. |
| 45 | Machine cut kota stone slab 20-25 mm thick as in riser of steps, skirting, dado and pillar laid over 10mm thick backing coat in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting as required, rubbing and polishing complete all as specified and as directed. |
| 46 | Rendering 15 mm thick cement plaster (1:4) on fair faces of brick work or concrete surfaces and to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 47 | Rendering 10 mm thick cement plaster (1:6) on other than fair faces of brick work or concrete surfaces and to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 48 | Rendering 5 mm thick cement plaster (1:3) on fair faces of concrete surfaces as in ceiling, chajja, shelves etc. finished even and smooth without using extra cement complete all as specified and as directed. |
| 49 | Rendering 15 mm thick cement plaster (1:3) on other than fair faces of concrete surfaces as on fascia of roof slab, chajja, shelves etc. finished even and smooth without using extra cement (including all necessary scaffolding, lifting arrangement for three storey building on external surfaces) complete all as specified and as directed. |
| 50 | PVC (SWR) pipes 110 mm bore single socketed in any length with rubber joint fixed to wall or laid in trenches or in floor with steel clamps complete all as specified and as directed. |
| 51 | PVC (SWR) pipes 75 mm bore single socketed in any length with rubber joint fixed to wall or laid in trenches or in floor with steel clamps complete all as specified and as directed. |
| 52 | PVC (SWR) bends of 110 mm bore complete all as specified and as directed. |
| 53 | PVC (SWR) bends of 75 mm bore complete all as specified and as directed. |
| 54 | PVC (SWR) branch piece, single 'Y' equal or unequal provided with access door of 110 mm dia complete all as specified and as directed. |
| 55 | PVC (SWR) floor trap plain including jointing with solvent cement 75 mm dia complete all as specified and as directed. |
| 56 | PVC (SWR) reducer of 110 mm dia complete all as specified and as directed. |
| 57 | PVC (SWR) vent cowl 110 mm bore complete all as specified and as directed. |
| 58 | PVC (SWR) WC connector with lip ring 110 mm complete all as specified and as directed. |
| 59 | Supply and fixing in repair Vitreous china squatting Pan 'Orrisa' pattern size 580 x 440 mm white with integral foot rest, 'P' or 'S' trap, and lime concrete bedding complete making good disturbed ground complete all as specified and as directed. |
| 60 | Supply and fixing in repair PVC low level flushing cistern 10 litre capacity white with inlet ball valve, float valve and handle including brackets, PVC flush pipe complete all as specified and as directed. |
| 61 | PVC connection 15 mm x 450 mm including brass check nut at both ends screwed for iron pipes of 15 mm bore complete all as specified and as directed. |
| 62 | 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 63 | Supply and fixing in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 45cm long and 15cm wide with chromium plated bracket guard and railing complete all as specified and as directed. |
| 64 | Supply and fixing in repairs 15mm bore pillar taps, cast copper alloy fancy type with capstan heads, chromium plated screwed down high pressure, screwed for iron pipe complete all as specified and as directed by Engineer-in-Charge. |
| 65 | Supply and fixing in repairs tubular towel rail 20mm dia 'D' type 60cm long between flanges chromium plated complete all as specified and as directed. |
| 66 | Supply and fixing in repairs Vitreous China wash basin, white, flat back, size 580 x 450 mm including 32 mm dia PVC waste pipe, chromium plated brass waste coupling 32 mm dia, pair of mild steel brackets or mild steel fastener/ bolts for fixing arrangements and 450 mm long PVC connection with PVC nut and washer complete at site all as specified and as directed. |
| 67 | Supply and fixing in repair Bib tap cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwed for iron pipe, suitable for 15 mm bore complete all as specified and as directed. |
| 68 | Supply and fixing in repair stop valve/ angle valve cast copper chromium plated screwed down high pressure with capstan head suitable for 15 mm bore, screwed both ends for iron pipe complete all as specified and as directed. |
| 69 | Supply and fixing in repair brass chromium plated shower rose 125 mm size swivel type with connecting rod 15 mm bore complete all as specified and as directed. |
| 70 | Supply and fixing in repair stop valve cast copper chromium plated concealed type screwed down high pressure with capstan head suitable for 15 mm bore complete all as specified and as directed. |
| 71 | Stainless steel gratings of 125 mm with waste holes of PTMT (minimum weight of 40 gms) complete all as specified and as directed. |
| 72 | Supply and fixing in repairs 15mm bore chromium plated Basin/ Sink mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and as directed by Engineer-in-Charge. |
| 73 | Supply and fixing in repairs 15mm bore chromium plated wall mixer with bend pipe for overhead shower pipe for mixing hot and cold water with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and as directed.Make: - Cera, Cat Part No : F2006402 or equivalent in makes as mentioned in Group - I of Appx 'F'. |
| 74 | Supply and fixing in repair Towel Ring chromium plated complete all as specified and as directed.. |
| 75 | Supply and fixing in repairs Chromium plated Soap dish of chromium plated complete all as specified and as directed. |
| 76 | Supply and fixing in repairs Curtain Rods 25mm dia mild steel, chromium plated with fixing brackets, stops, side funnels etc complete with all fittings all as specified and as directed. |
| 77 | 16mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down 15mm steel tubing complete all as specified and as directed. |
| 78 | 20mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down 15mm steel tubing complete all as specified and as directed. |
| 79 | Cutting chasis for concealed water tubing or concealed conduit and making good in cement mortar (1:3) of grith exceeding 10 cm and not exceeding 20 cm in brick wall complete all as specified and as directed. |
| 80 | 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection laid to an outward slope of not less than (1:12), cast in panels not exceeding 2.0 Sqm areas with 6 mm wide joints. The joint shall be filled with mastic filling and 10 mm wide joints between the walls and plinth protection shall be filled with mastic filling and finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 81 | Rotational moulded polyethylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling of existing water tank, including 20mm Ball Valves, 20mm Tank nipple complete all as specified and as directed by Engineer-in-Charge. |
| 82 | Supply and fixing in repair stop valve 20 mm dia cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 83 | Applying one coat of synthetic enamel paint tint over old painted steel surfaces over 10 cm in width or girth including preparation of old surfaces of steel complete all as specified and as directed. |
| 84 | Preparation of newly plastered surface and applying two coats of premium acrylic smooth interior emulsion on wall and ceiling of approved colour with silicon additive and Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based interior grade primer @ 0.9 ltr (undiluted)/ 10 Sqmtrs diluted with water in (1:1) ratio and 1mm thick interior grade wall putty as per manufacturer's instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.Notes: - (a) The work pertaning to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e.paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 85 | Complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of internal wall/ ceiling to be done with repair mortar to get even surface including preparation of old surface of wall/ ceiling by filling cracks/ crack fill paste and make good smoothen surface by sand paper and applying two coats of premium acrylic smooth interior emulsion of approved colour with silicon additives and Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/10 Sqmtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer's instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI complete all as specified and as directed. Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and as directed.Notes: - (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 86 | Preparation of newly plastered surface and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive and Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/ 10 Sqmtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer's instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed. Notes: - (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 87 | Complete removel of existing treatment including fascias, cornices etc old plastered surface and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive and Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/ 10 Sqmtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer's instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.Notes: - (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 88 | Stainless steel kitchen sink made of stainless steel of 1 mm thick sheet including plugs, washers and PVC waste pipe of 40 mm dia fixing with complete on appropriate size of cantilever brackets of mild steel angle or GI pipe 15 mm dia with proper arrangement to hold and fitting of sink complete all as specified and as directed at site and connecting union to pipe. The overall size of sink 495mm x 420mm and bowl size 410mm x 330mm x 160mm. |
| 89 | Supply and fixing in repairs Stainless Steel plate rack made out of 1mm thick sheet of size 750 x 600 x 250mm of size having partition and fixed with steel fasteners or steel screwed complete all as specified and as directed. |
| 90 | Providing water proofing treatment to sunken floors all as given below: -(a) Making fillet of size 25mm x 25mm at corner of slab and wall with polymer modified cementitious (PMC) mortar consisting of one part of tapecrete P-151, two parts of cement and 6 parts of fine sand by weight.(b) Sealing of joints of pipe with epoxy putty CICO POXY LC or epoxy mortar CICO POXY 2125.(c) Cleaning the concrete surface by brushing and watering and applying a coat of tapecrete P-151 Acrylic Polymer Modified cementitious slurry consisting of one part of TAPECRETE P-151 and two parts of cement by weight. The coating shall be carried out upto 300mm above FFL and shall be allowed to dry for 4-6 hours.(d) Applying a coat of TAPECRETE brush topping 1.5mm thick consisting of one part of TAPECRETE P-151, two parts of cement and two parts of silica sand by weight and cured to 2 days.(e) Applying 15mm thick plaster in cement mortar (1:4) mixed with CICO super @ 100ml per 50 Kg cement on treated surface.(f) Filling the sunken portion with PCC (1:5:10) type E-2 (using 40mm graded crushed stone aggregate) upto required level complete all as specified and as directed. (PCC shall be measured and paid separately under respective item). |
| 91 | Cement concrete (1:5:10) type E-2 (using 40 mm graded crushed stone aggregate) as in sunken portion complete all as specified to receive floor toping as specified after carrying out the required tests of water proofing and all as directed. |
| 92 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 93 | Removing existing treatment from roof surfaces such as tiling, tarfelt, fungus, moss, dust etc., cleaning the surface of all foreign material by wire brushing and dusting and racking out RCC slab complete all as specified and removing the debris outside defence land and all as directed. |
| 94 | Cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, as per manufacturers method statement and cement in mixing ratio of (1:4) where ever required complete all as specified and as directed. |
| 95 | Providing cement concrete (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 96 | Home Shield PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied, water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty. ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties: -(i) UV resistant, prevent yellowing and weathering.(ii) Highly elastic upto 350% and crack bridging. (iii) Excellent adhesion on porous and non-porous substrates.(iv) Tensile Strength >10 N/Sqmm with GeoTextile fleece.(v) Solar Reflective Index (SRI) more than 109-111 ASTM E1980-11.System: First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent), Coverage : 0.2 Kg/Sqm (with 50% dilution of water), Reinforcement: Geotextile 40 gsm, Second coat: Home shield roofkoat (or equivalent), Consumption: 0.5 Kg/Sqm, Third coat: HS PU roofkoat (or equivalent), Consumption : 0.8 Kg/Sqm. System buildup - 1.5 Kg/ Sqm with geotextile of 40 gsm. |
| 97 | Angle iron work fixed independently without connecting plates etc (cut to ordinary length) such as collar stand etc of Fe 410-W (E-250 Grade) Quality 'A' complete all as specified and as directed. |
| 98 | Framed work as in grills, gratings etc with end of bars shouldered or riveted or forged into spikes, framed guard bars confirming to Fe-290, Gde-E-165 complete all as specified and as directed.Note: - Grills (8 mm square bars and 6mm steel flat bars) shall be fixed in wall with steel screws not less than 100 mm long as inner face of aluminium windows. |
| 99 | Mild steel TMT bars 6 to 8 mm dia as in reinforcement, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 100 | Providing pre-cast cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in cover slab of manholes, septic tank, soak well etc set in cement mortar (1:4) with plain fair faces including chamfered weathering, throating etc including necessary use and waste of form work complete all as specified and as directed. |
| 101 | E/M Portion: -Taking down old unserviceable copper/ aluminium point wiring concealed/ batten (light, fan, socket or power) complete including fixtures and fittings such as switches, sockets, ceiling roses, bell push, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. |
| 102 | Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed. |
| 103 | Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 2.5 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed. |
| 104 | Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall for inverter connection of light and fan point complete all as specified and as directed. |
| 105 | Complete Point wiring with 1.5 Sqmm two core multistranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall, plastering after concealing conduit, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular swicthes, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer-in-Charge for the following: - |
| 106 | Description all as per Ser item No 105.00 here-in-before but for multi 5 Amp socket outlet on same board complete all as specified and as directed. |
| 107 | Description all as per Ser item No 105.00 here-in-before but for multi 3 pin socket outlet 5 amp socket on independent board complete all as specified and as directed. |
| 108 | Description all as per Ser item No 105.00 here-in-before but for one light point controlled by two 2 way switches, with cable 1.5 Sqmm complete all as specified and as directed. |
| 109 | Description all as per Ser item No 105.00 here-in-before but for One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm size complete all as specified and as directed. |
| 110 | Description all as per Ser item No 105.00 here-in-before but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green colour complete all as specified and as directed by Engineer-in-Charge. |
| 111 | Modular switch 1 way 6A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 112 | Modular socket 6A - 5 pin combined, 2 module, 240 Volts ISI marked complete all as specified and as directed. |
| 113 | Modular switch 2 way 6A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 114 | Modular bell push 6A, 1 module, 240 volts ISI marked complete all as specified and as directed. |
| 115 | Modular switch 1 way 16A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 116 | Modular socket 6A/ 16A - 6 pin combined 2 module, 240 Volts ISI marked complete all as specified and as directed. |
| 117 | Ceiling rose, 3 Phase/ PVC/ Polycarbonate isolated body complete all as specified and as directed. |
| 118 | Calling bell Ding Dong AC 230 Volts, single pole complete all as specified and as directed. |
| 119 | Fan regulator stepped electronic type suitable for AC, 240 V complete all as specified and as directed. |
| 120 | Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 121 | Self ballast LED retrofit lamp with PVC body and PC Diffuser 9 Watt 230 Volt 6500 K complete all as specified and as directed. |
| 122 | LED lights fitting 1 x 20W, 220V, AC PVC batten type along with LED tube rod with driver, holder and power factor >0.90, 100 Lumen/ Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 123 | LED light fitting 1 x 9W/ 1 x 10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 124 | LED light fitting mirror type with high output diffuser 2 feet, 12 watt, 220 V AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 125 | Supply and fixing in replacement Ceiling fans, BLDC motor tech complete with remote and blades, down rods, hanging hooks and accessories, 230 V, 1200mm sweep, suitable for working on fan regulators, minimum air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direcet current motor (BLDC) complete with fixing arrangement complete all as specified and as directed.Note: - Contractor will deposit the oid unserviceable ceiling fan to MES store for further course of action complete all as specified and as directed by Engineer-in-Charge. |
| 126 | Exhaust fan made of sturdy Engineering plastic complete with louvers, shutter, voltage 230 V, 50 Hz, RPM 1200, copper winding of sweep 300 complete all as specified and as directed by Engineer-in-Charge. |
| 127 | Exhaust fan, steel body AC single phase, 230V of size 300mm sweep with blades and frame and louvers making holes for 300mm exhaust fan of suitable shape and size into or through brick walls including plastering for making good to the original surfaces of any description disturbed including painting/ distemper matching with the existing colour including taking down old one and deposited to MES store complete all as specified and as directed.Note: - The rates includes for making good to the original surfaces of any description disturbed including painting/ distemper matching with the existing colour. |
| 128 | Electric water heater, storage type steel body glass line coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, BRV, connection piece etc complete all as specified and as directed.Note: - Rates are deemed to be included the cost for fixing of 4 Nos rawl plug of suitable size (4\\" to 6\\") nuts and bolts, grouting work in RCC/ brick wall including taking down old one and deposited to MES store. |
| 129 | Supply and fixing in replacement of Distribution board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA three pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar including taking down old unserviceable distribution board/ MCB any type complete all as specified and as directed.Note: - (i) MCB's shall be measured and paid separately. |
| 130 | 415V 10 KA 'B' curve MCCN TP 63 Amp capacity in the distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 131 | Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCB's should be of same make. |
| 132 | Supply and fixing in replacement SPN 40 to 63 Amps raating 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 133 | Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 134 | Taking down existing serviceable/ unserviceable electric meter alongwith existing angle iron steel box from the wall and refixing electric meter in position after repair replacement of MCB TPN box including replacement of PVC flexible conduit for cable protection complete with making the existing wall neat and clean including patch work, plaster, brick work and white wash as per site requirement complete all as specified and as directed. |
| 135 | Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtrs deep below ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nuts, bolts, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5m length for drawing earth lead wire protection, common salt, charcoal etc complete all as shown in electrical plate No 3 of SSR Part - I and testing on completion complete all as specified and as directed. |
| 136 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and making good bottom surface for laying/ removing of cable complete all as specified and as directed in soft/ loose soil. |
| 137 | Supply and laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip of wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V cross scetional area 25 Sqmm 4 core in and including taking out old one complete all as specified and as directed. |
| 138 | Sand filling in cushioning bed of cable and consolidation complete all as specified and as directed by Engineer-in-Charge. |
| 139 | Supply and laying common burnt clay building sub class 'B' bricks, laid over sand cushioning laid at right angle along with cable complete all as specified and as directed. |
| 140 | Returning filling in excavated soil in trenches, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed by Engineer-in-Charge. |
| 141 | Removal of excavated any type of soil to a distance not exceeding 50m complete all as specified and as directed by Engineer-in-Charge. |
| 142 | Supply and laying GI tubing light grade including all accessories such as protection, laid under plinth/ floors/ path culverts with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works of sizes 40mm dia complete all as specified and as directed by Engineer-in-Charge. |
| 143 | Cutting to existing pipe 15/20mm dia in position and insertion of 'T', additional alteration in position complete with GI fittings as required at site for connecting new GI pipe complete all as specified and as directed by Engineer-in-Charge. |
| 144 | Galvanised iron pipe medium grade of size 15mm complete with all fittings such as bend, tee, reducer, elbow and union of required size complete all as specified and as directed.Note: - Rates deemed to be included for fixing of mild steel clamps of suitable size to hold the GI pipe. |
| 145 | Gun metal or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15mm dia complete all as specified and as directed. |
| 146 | PVC connection pipe heavy duty ISI marked of 15mm size with PTMT nuts of length 450mm from GI pipe to geyser complete all as specified and as directed by Engineer-in-Charge.Note: - PVC connection pipe should be compatible to hot and cold water. |
| 147 | Bib tap fancy type cast copper alloy with crutch or butterfly handle, screwed down for iron pipe 15mm dia complete all as specified and as directed by Engineer-in-Charge. |
| 148 | Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 2 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCB's should be of same make. |
| 149 | Supply and fixing in replacement SPN 32 Amp rating 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Oct 09, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender