Housing Urban and Rular Development Government Departments Closing in 12 days TDR #57594361

Tender For Electrification, Fire Fighting & Allied Work Of Hindu Study Center At Doon University, Dehradun

Issued by Government Departments · Dehradun, Uttarakhand
Tender Value
3.88 Crore
Estimated cost
Bid Submission
03 Oct 2026
12 days left
EMD
7.76 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrification, Fire Fighting & Allied Work Of Hindu Study Center At Doon University, Dehradun

BOQ

Name of Work:- Electrification, Fire Fighting & Allied work of Hindu Study Center at Doon University, Dehradun
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group - C
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
42 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
52 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
62 X 4 sq. mm + 1 X 4 sq. mm earth wire
72 X 6 sq. mm + 1 X 6 sq. mm earth wire
82 x 10 sq.mm + 1 x 6 sq.mm. earth wire
92 x 16 sq.mm + 1 x 6 sq.mm. earth wire
104 x 10 sq.mm + 2 x 6 sq.mm. earth wire
11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
123 x 1.5 sq. mm
133 x 2.5 sq. mm
143 x 4 sq. mm
153 x 6 sq. mm
16Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
17Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
18Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
19Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
20Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
21Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
22Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
235/6 A switch
243 pin 5/6 A socket outlet
25Supplying and fixing brass batten/ angle holder including connection etc. as required.
26Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
27Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
28Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
29Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
30Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
31Upto 450 mm sweep
32Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.
33Supply of Recess/ surface mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
34Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. ).
35Supply of Recess / Surface mounting round 10 Watt 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
36Supply of Recess/ Surface mounting square 18 to 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
37Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp
38Supplying of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp
39Supply of 9W to 15 W 3 Star LED Wall Light Blub complete in all respect.
40Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
41Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.
42300mm EXHAUST FAN
43Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 30Watt. to 35 Watt and Confirming to IP66 protection having Company LOGO Engraved complete in all respect with 4000-5000 system lumens High Power LED with lenses, >110lm/W, PF>0.95, THD <10% at full load, CRI>70, Avg Life Class 50000Hrs@L70,fitting itself suitable for 60-65mm OD pipe
44Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.
4540 A,25KA,FP MCCB
4663 A,25KA,FP MCCB
47100 A,30KA,FPMCCB
48Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4912 way, Double Door
5016 way, Double Door
51Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
524 Way Double door
536 way Double door
548 way Double door
55Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)
564 way , (4+12) Double door
57Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5840 amps TP MCB
5963 amps TP MCB
60Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
6140 amps
6263 amps
63Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
6440 amps
6563 amps
66Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
67Single pole
68Double pole
69Triple pole
70Triple pole and neutral
71Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
72Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
73Supply installation testing and commissioning of LT panel . The panel should be Designed as per the latest standard IEC 61439. The panel should have Bus bar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyester glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as Form of separation. The panel should be equipped with suitable size of CT and display meter for VAF measurement. The panel should be suitable for seismic zone V.
74LT Outgoing should be IP 54 and should have switchgears as below.
75Building Main LT Panel ( TTA Panel)
76INCOMER:-
771 No 1000 Amp. 4P EDO ACB of 50KA (Ics=Icu) Breaking Capacity
781 No 125 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity
791 No 125 Amp. TP Contractor
802 No. Multi Function Meter.
812 Set of phase indicating lamps with Single Pole MCB.
822 Set of ON / OFF indicating lamps with Single Pole MCB.
832 Set 50,50N,51,51N,27,32,49,59,86,95 CT's control.
84BUS BARS:-
851200 Amps. TP&N aluminium bus bars
86OUT GOINGS:-
872 Nos. 400 Amps. FP MCCB (35 KA)
882 Nos. 250 Amps. FP MCCB (35 KA)
894 Nos. 100 Amps. FP MCCB (35 KA)
902 Nos. 63 Amps. DP MCB
912 Nos. Space & Spare
92Building EM Panel ( TTA Panel)
93INCOMER:-
941 No 400 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity
951 No 400 Amp. Motorised Changeover Switch
961 No. Multi Function Meter.
971 Set of phase indicating lamps with Single Pole MCB.
981 Set of ON / OFF indicating lamps with Single Pole MCB.
99BUS BARS:-
100600 Amps. TP&N aluminium bus bars (25 KA)
101OUT GOINGS:-
1022 Nos. 200 Amps. FP MCCB (25 KA)
1034 Nos. 63 Amps. FP MCB
1044 Nos. 40 Amps. FP MCB
1053 Nos. 40 Amps. DP MCB
1062 Nos. 32 Amps. DP MCB
1072 Nos. Space & Spare
108Building UPS Panel Block-1
109Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
110Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
111Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
112Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
113Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
114Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
115Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
116Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
117Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
118Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
119Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.
12010 Zone panel for fire alarm system
121250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby)
122Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos.talk back unit -1 set.
123Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set.
124Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.
125Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete asrequired -1 set.
126Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set.
127Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required
128Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
129Up to 35 sq.mm.
130Above 185 sq.mm. and up to 400 sq.mm.
131Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
132Up to 35 sq.mm.
133Above 185 sq.mm. and up to 400 sq.mm.
134Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
135Upto 35 sq. mm (clamped with 1mm thick saddle
136Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
137Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
138Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment
1393.5 x 300 sq.mm.
1403.5 x 185 sq.mm
1413.5 x 70 sq.mm
1423.5 x 35 sq.mm
1433.5 x 25 sq.mm.
1444 x 10 sq.mm
1452 x 10 sq.mm,
146Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
1472 X 10 sq. mm (19mm)
1483½ X 25 sq. mm (28mm)
1493½ X 35 sq. mm (32mm)
1503½ X 70 sq. mm (38mm)
1513½ X 185 sq. mm (57mm)
1523½ X 300 sq. mm (70mm)
1534 X 10 sq. mm (25mm)
154Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
155100mm dia
156Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
15763 mm dia (OD-63 mm & ID-51 mm nominal)
158Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
159100 mm wide x 50 mm depth x 1.6 mm thickness.
160150 mm wide x 50 mm depth x 1.6 mm thickness.
161Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
162100 mm wide x 50 mm depth x 1.6 mm thickness.
163150 mm wide x 50 mm depth x 1.6 mm thickness.
164Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
165100 mm wide x 50 mm depth x 1.6 mm thickness.
166150 mm wide x 50 mm depth x 1.6 mm thickness.
167Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:
1682 Pair (4 core)
169Supply, Laying Connectig ad testing of multi core (10 Pair) Telwphone cable of conductor size 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed jelly Filled.
170Supply,Laying connecting and Testing of 10 Pair cross Jumper type Telephone tag block krone make in surface /recess in wall required size of M.S box with hinged lockable dully stove enamel painted
171Supply,Laying connecting and Testing of 10 Pair telephone tag block krone make in surface /recess in wall.Requried size of M.S box with hinged lockable duly stove enamel painted.
172Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required
1731 or 2 Module (75mmX75mm)
174Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
175Telephone socket outlet
176RJ-45 Data Socket outlet
177Supply of Hybrid PBX With CPU and AC Power Supply With License For 6 Slots, Expandable up to 48 Analoge Ports and Max. 100 IP User
178Supply of SLT Cards 8
179Supply of 2 DKP port + 2 Ext Port
180Supply and Installation of CLI based push button telephone set.
181Propriatary Full duplex HF digital phoe set with 12 ouble function programmable keys,4 line display ,call waiting ,3 way confrence,call transfer,User to user signaling.
182Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
183Supply Installation testing and commissioning of 24 port L2 Managed switch having port density 24 No.of 10/ 100/ 1000Mbps/4 1 G SFP Ports
184SITC of UTP CAT 6 UTP Patch Cord 1 Mtr.
185SITC of UTP CAT 6 UTP Patch Cord 3 Mtr.
186Supply and Fixing of 12 U wall mounting Networking Rack.
187Supply Punching and Fixing of 24 ports Patch Panel
188Supply,Laying of UNI Tube Single Mode 6 F Armored Fiber Optic Cable
189Labour chagres for optical fiber cable splicing and jointing with Termination.
190Supply and Fixing of 6F port LIU box fully Loaded.
191Supply and Fixing of Single Mode Patch cord SC to LC 3mtr.
192Supply and Installation of Single Mode SFP Module For Switch
193Supply and Fixing of 25 mm Sizes of Medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good thw same in case of recessed conduit as requried.
194Supply, installation, testing and commissioning of IP based, 2 MP, FULL HD WDR IR DOME CAMERA 20-30 MTRS, colour indoor verifical dome camera, 3.6 MM FIXED LENS, 1/3 \\", 4 Mega Pixel PS CMOS Image Sensor, WDR (120 dB), Day/ Night (ICR), IR Range of 30 Mtrs, IP67 and all ancillary equipments and all accessories.
195Supply, installation, testing and commissioning of IP based, 2 MP, FULL HD WDR IR bullet CAMERA 20-30 MTRS, colour indoor verifical dome camera, 3.6 MM FIXED LENS, 1/3 \\", 4 Mega Pixel PS CMOS Image Sensor, WDR (120 dB), Day/ Night (ICR), IR Range of 40 Mtrs, IP67 and all ancillary equipments and all accessories.
196Supply, Installation, Testing and Commisioning of HI FOCUS 32 Channels NVR with 12MP (4000 X 3000) bandwidth, HDMI/ VGA simulation video output, support 8 SATA HDD's upto 16 TB, 1 ESATA up to 16 TB, supports multi brand network cameras. Each NVR shall have a storage capacity so as to record a backup for 15 days at 4 CIF @ 25FPS.NVR should have system expandibility feature of at least 20% of current requirement, redundant fan and power supplies, outputs TCPIP network feature & server software monitor outputs. The NVR should be networkable via IP protocol & should be able to connect to a web based system for remote viewing via web system. Vendor should submit the storage / HDD Calculation.
197SITC of WindowsSurveillance Hard Disk 6TB
198Supply & instalation of 6U rack-with PDU unit
199Supply Installations Testing and Commissioning of 65 \\" 4K ultra HD Smart /Google Display, HDMI Port, Component Video Inputs, 1 Digital Audio Out,
200Supplying installation testing commissioning ofGigabit Uplink, 8 10/100Mbps PoE RJ45 port (port 1~port 8)
201S/D of UTP 4 Pair CAT 6 LAN cable in the existing PVC conduit as required.
202S/F of 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
203SITC of 2 Ton 3 star Hot and Cold Split Air Conditioner, connecting outdoor unit with copper pipe with required insulation
204SITC of 1.5 Ton Cassette Air Conditioner Unit, connecting outdoor unit with copper pipe with required insulation.
205S/F MS Outdoor Stand for AC out door unit
206S/F 5 KVA Stabilizer copper winding
207S/L 3 x 2.5 Sqmm core flexible Copper Counductor
208S/L UPVC drain Pipe 25mm with Albow socket etc.
209S/L Copper Refrigerent pipe 5/8 and 1/4 with nitrile insulation of proper sizes
210UPS SYSTEM
211Supply, installation, testing & commissioing of 10 KVA UPS at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, inbuilt isolation transformer as per specification given in the document with following broad features.
212THD(i) shall be less than 3% in the entire loading range.
213UPS shall carry design output at 40 deg.
214Shall have soft start and hold of for incoming supply.
215Invertor capability to supply 150% load for 5 sec.
216Three Phase Input and Three Phase Output. ( Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)
217Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
218Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
219Suitable size of copper cable between UPS and battery bank shall be provided
220Battery with installation, Battery Rack & connector.
221UPS described as above
222Supply,Installation,Testing and Commissioning of Electric Traction Passenger Lift of Makes:Kone/Otis/Schindler/Mitsubishi/Johnson with• Rated capacity :- 13 Passenger/884Kg• Floors :- Ground to Third floor (4 Stops / 4 Landings)• Travel :- 14.4 mtrs to 16 mtrs.aprox• Location of Lift Machine:- without Machine Room• Rated speed :- 1 mps VS
223Load & Capacity 884 kg or 13 persons
224Speed 1 m/s
225Stops & Openings 4 stops & 4 openings, Single entrance car
226Total no of opening 1 entrances
227Travel height 12 m aprox
228Elevator - Grouping Simplex, Full Collective Control
229Well Dimension 2000 mm width and 2400 mm depth (required)
230MAP Floor Position Topmost floor (TOP)
231Car dimensions 1100 mm wide x 2000 mm deep x 2200 mm high
232Door type Two-panel centre opening Plain Panel
233Car design SS silver brushed
234Car Panel Finish Stainless steel Hairline AISI441
235Handrail Round Bend Handrail Silver brushed stainless steel (ST4) at Rear Wall
236Flooring 20 mm recess space for stone fixing or tiles.
237Car Door Finish Stainless steel Hairline AISI441
238Standard Feature Correction drive to next level Emergency Alarm @ Main Floor Car Call backwards, Overload function, constant indication/Buzzer Bypass load Function, Auto Cut off Fan and Light Manual Rescue OperationCentralized Hoisting for lesser vibration and smooth travel Pit LadderMicro movement Led Based Buttons, L.W.D. (Load Weighing Device)Direction & Position Indicator In Car & Landing Advanced Car Position Indication, Automatic Brake Test function every 11hours Every run brake supervision, Phase reversal functioning Signal Fixtures+10% to –10% Voltage Fluctuation Withstanding Capacity Door Close Button, Door Open Button Car Emergency Light Fireman DriveCurtain of Light 169 Beams, Accurate Relevelling, Automatic, Closed Door E, With emerg.opening device
239Additional FeatureEmergency Rescue Device with audio announcer 2 Way Dedicated IntercomNudging service Attendant Service, Parking Predefined floor - Doors closed Lift Announcer, Dummy floors BMS, Round spot LED light Access Control Provision B, 2 Hours Fire rated
240Audio Video of Conference
241SITC OF ViewBoard® 86\\" 4K Interactive Display Physical resolution: 3840 x 2160 4K UHD etc.
242SITC of -1C-N slot-in PC is the ideal integrated solution for the ViewBoard® interactive displays and presentation displays. With dual-band Wi-Fi and Bluetooth, a powerful Intel® 11th Core™ Processor, 8GB DDR4 SO- DIMM memory, and 256GB SSD storage, the VPC25-D3A-O1-1C-N contains the computing power needed to operate CPU intensive applications.
243A&T Video conferencing 12 x optical PTZ Camera having Equipped with a Sony 1/2.8 inch image sensor, USB 3.0 interface with HDMI video output, Full HD 1080p signal output format with a high frame rate of 30 fps, having +30° ~-30° Tilt also +100° ~-100° paning angle also the camera should also have RS-232 In and Out/USB for controlling the camera
244Master Control Unit TS790 with In-Built DSP and 120 watt amplifier and USB Port for Computer connectivity for USE OF Conferencing Mics in V.C.
245SITC of Mic Chairman Unit TS 790
246SITC of Mic Delegate Unit TS 790
247SITC of 30 Watt ceiling Mount Speaker
248SITC of Conferencing system connecting cable 10 Mtr
249SITC Speaker Cable 1 mm to 1.5 mm
250SITC of Floor Mount 86” TV Cart
251SITC of HDMI Splliter 1 In 4 Out
252External Electrical
253Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
254Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
255Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
256Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
257Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
258Supply & Laying of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Make:- Kei, Havells & Polycab or Eq.
2592 x 4 sq.mm,
260Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
2612 X 6 sq. mm (19mm)
262Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
263100mm dia
264Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
26563 mm dia (OD-63 mm & ID-51 mm nominal)
266Supplying and erection of Decorative Lighting Pole of length 4 mtr . The pole made out of Galvanised Mild Steel Tubes with base plate 250x250x12mm .The poles to be primer coated and painted with polyurethane paint.The Poles are suitable for single/ double/ triple/ four side post top/drop down luminaries.The pole has a sevic window at the bottom profile comprising 4-way 25 Amp connector terminal and a MCB etc. The pole to be mounted on a 1:3:6 cement concrete base (pedestal) of 450X450 mm and 300 mm L-Type foundation bolts 4x16 mm dia. with nuts, templates and all complete as per approved drawing. Foundation RCC 1:3:6 shall be of size 450x450mm and depth 900 mm c/c as per approved drawing.The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing, complete in all respects as required.
2674 Meter long having 76mm dia at bottom and 60mm dia at top
268Providing and fixing of LED 45 Watt Post top (IP65) fixture of following capacity are made of Die cast Alum. housing with three nos. die cast Al arms are provided to support the housing power LED's are mounted on metal clad PCB's and LED's & PCB assembly are mounted extruded aluminium heat sinks. A UV stabilized PC diffuser is provided as complete in all respects as required
269Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refillingetc. as required.
270Above 4.5 metre and upto 6.5 metre
271Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
2721 output per phase and suitable for single phase supply
273Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
274Double pole
275Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required
27632 mm dia
277FIRE HYDRENT
278Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
279Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
280Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
28180 mm nominal bore (yard hydrant)
282100 mm nominal bore (pipe in pump room & pump room to FFTG shaft)
283150 mm nominal bore ( pump room, external hydrant, FBI & siamese connection pipe, pumproom to FFTG shaft)
284200 mm dia (wall thickness 6.3 mm)
285Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required :
2862 way - 100 mm dia M.S. Pipe
2874 way - 150 mm dia M.S. Pipe
288Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
289150mm dia
290Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump)
291(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
292b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
293(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
294(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
295900 lpm at 35 m Head
296Fabricating & Supply, installing, testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 9.3 KW/12.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. Star delta starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle. (At Terrace floor)
297Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump)
298Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump & underground fire pump tank)
299Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
300200 mm dia.
301150 mm dia.
302100 mm dia.
30380 mm dia.
304Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
305200 mm dia.
306150 mm dia.
307100 mm dia.
30880 mm dia.
309Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
310200 mm dia.
311Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
312100 mm nominal bore
313Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
314Single headed Gunmetal
315Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
31620 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
31720 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
318Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
319Single headed Gunmetal
320Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
321Gun metal
322Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
323Gun metal
324Providing and fixing standard fire mans axe with heavy duty insulated rubber handle.
325Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door: 900mm Wide & 1500mm Height)
326Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
327Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
328Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
329Providing & Fixing of M.S. fire hose weather proof cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & \\"FIRE HOSE\\" written on front.
330P&F of CO2 Portable & Trolley Fire extinguisher, 4.5kg Carbon-Dioxide type Flat base Horn Including Valve, High Pressure Rubber Wire Braided Discharge Hose of not less than 10 mm dia. & complete in all respects including initial fill with CO2 Gas confirming to IS:15222.
331P&F 9kg ABC MAP-90% Powder based Fire Extinguisher, Applicable Fire Class A, B & C, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), IS 15683:2006 Marked.
332Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.
333FIRE PUMPS - ELECTRICALSupplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
334(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads.
3351620 lpm at 70 m Head
336FIRE PUMPS - DIESEL ENGINE DRIVENSupplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
337Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plasteredand with anti vibration pads.
3381620 lpm at 70 m Head
339JOCKEY PUMP:-Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)
340Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
341Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
342180 lpm at 70 m Head
343Pressure VesselProviding, fixing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.working pressure:- 7 kg/sqcmtest pressure: 10 kg/sqcm
344(450 mm dia & 2000 mm height)
345Providing & fixing of Anti vibration Expansion Bellow at pump outlet etc. as required.
346150 mm dia.
34780 mm dia.
348Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS)
349150 mm dia.
350100 mm dia.
35180 mm dia.
352Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
353INCOMING
354250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0 500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A
355OUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
356Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
357Jockey Pump63A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
358DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engineSystem ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57594361
AUTHORITY Government Departments
TENDER VALUE 3.88 Crore
LAST DATE 03-10-2026
Authority
Authority Name Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited
Work Description Tender for Electrification, Fire Fighting & Allied Work Of Hindu Study Center At Doon University, Dehradun
Basic Detail
Tender No 1464/BRIDCUL/1091/26 Dated 11.09.2026
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 19 Sep 2026
Submission Date 03 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 3.88 Crore
Tender Fee 5900
EMD 7.76 Lakhs
Exemption Not Available
Document List
48c52574-0b15-4a88-a082-b4087987b61f.html
BOQ_118294.xls
sbdelecthscdoonuniversityf.pdf
Tendernotice_1 (33).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

48c52574-0b15-4a88-a082-b4087987b61f.html

xls

BOQ_118294.xls

pdf

sbdelecthscdoonuniversityf.pdf

pdf

Tendernotice_1 (33).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders