Tender for Special Repair To Roof Treatment Of Bldg No. P-66, P-67, P-70 And P-76 Under Aor Of Age B/R-I Of Ge (South) Mamun
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) or tiling etc in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 3 | Taking down cement plaster/wall tiles including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed |
| 4 | M&L for Brickwork with Fly Ash Bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and directed. |
| 5 | All as per description of serial item No. 4.00 here-in-before but except bricks.Note: Serviceable bricks retrived by dismantling old brick work shall be re-used. |
| 6 | M&L for 15mm thick rendering in two layers (5mm thick in CM 1:4 over 10mm thick in CM 1:6) on brick work and concrete surfaces of wall, finished the surface even and smooth without using extra cement, mixing and including WPC @ 200ml/bag of cement complete all as specified and directed. |
| 7 | M&L for two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed |
| 8 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 9 | Supply & Fixed steel water tubing 15 mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling and floors complete all as specified and directed. |
| 10 | Fixing only old steel tubing 15 mm bore and connections in new or old position (walls, ceiling, floor etc.) complete all as specified and directed.Note: Old serviceable pipes retrived by taking down shall be re-used. |
| 11 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 12 | Supply & Fixed steel water tubing 20 mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling or laid in floors complete all as specified and directed. |
| 13 | Fixing only old steel tubing 20 mm bore and connections in new or old position (walls, ceiling, floor etc.) complete all as specified and directed.Note: Old serviceable pipes retrived by taking down shall be re-used. |
| 14 | Disconnecting existing PVC tanks, setting aside (or lowering if required) for repair, cleaning and removing all scale and dirt by using bleaching powder from tank and from mouth of cirulating pipes etc and hosting if required reconnecting and refixing in position of capacity 500 ltrs and making good for running of water from tank to inside of bldgs and complete all as specified and directed. |
| 15 | Disconnecting existing PVC tanks, setting aside (or lowering if required) for repair, cleaning and removing all scale and dirt by using bleaching powder from tank and from mouth of cirulating pipes etc and hosting if required reconnecting and refixing in position of capacity 1000 ltrs and making good for running of water from tank to inside of bldgs and complete all as specified and directed. |
| 16 | S&F in repair Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 17 | S & F in repair Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 25mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 18 | S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls / laid in trenches complete all as specified and directed.Note:- The measurement of pipes shall be net as fixed between the fittings including short lengths, without any allowance for cutting and waste or for the portions of pipes entering the sockets of the adjacent pipe or fitting. Fittings and accessories such as bends, branches, sockets etc. shall be enumerated afterwards and measured separately. Rates include for all necessary extra joints, cutting and waste. |
| 19 | Supply & fixed, 110 mm bore PVC (SWR) bends any radius, with or without excess door complete all as specified and directed. |
| 20 | Taking down cement plaster and decayed concrete of any description, upto tripple storey of building, from roof projection, chajja etc and making good the decayed portion with cement mortar 1 :3 mixed with water proofing compound as per manufacturers instruction or PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) including necessary form work and finally finished the surface with 15mm thick cement plaster in CM 1:3, complete all as specified and directed. |
| 21 | M&L for 75 mm thick cement concrete 1:3:6, type C-1 (using 20mm graded aggregate) as in plinth protection finished even and smooth using extra cement, forming joints and filling with mixture of paving bitumen & sand in 1:3 complete all as specified and directed. |
| 22 | M& L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, bed plates benching,floor by maintaing required gradient / undulation etc slightly rounded or chamferred angles and throating, complte all as specified and directed. |
| 23 | Supply only liquid water proofing compound conformimg to relevant IS complete all as specified and directed. |
| 24 | Taking down existing roof treatment of any description incl mud phuksha or PCC padding of any description, any No. of layers including removal to debries in low laying area exc 1.00 KM but n exc 2.00 KM complete all as specified and directed. |
| 25 | S&F Wire netting made of stainless steel wire 0.71 mm dia with size of mesh 25mm fixed with tinned tacks of stainless steel wire staples complete all as specified and directed. |
| 26 | M&L for cement concrete 1:1.5:3 type B-0 (using 12.5 mm graded stone aggregate) as in leveling course on existing roof, rounded and chamfered on edges, mixed with & including WPC @200ml/ cement bag of 50 Kg complete all as specified and directed. |
| 27 | M& L preperation of inaccessible roof surface by scrapping and properly cleaning the existing roof treatment in any number of layers upto original RCC roof top surafce. Apply first coat Fiber reinforced Elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres with sun reflective index(SRI) of 100-110 , hsving minimum elongation of 350% tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shall resisit 10 bars of hydrostatic pressure reduce surface temperatureuoto 10 degree celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3 mm thickness weave in leno pattern having 45 gsm/Sqm and pasting it properly iwith overlap of 50mm and aloow it toodry.Apply second of undiluted coat @4.5 Ltr/Sqm. Apply third and final co for 10mm thick cement rendering in CM 1:E168at undiluted @0.45 ltr/sqm. Aplly third and final coat [email protected]/Sqm as directed by Engr in Charge.(a) M&L for 10mm thick cement rendering in CM1:3 and finishing the surface even and smooth before application of priming coat Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender