Housing Urban and Rular Development Government Departments Closing in 31 days TDR #57590591

Tender For Development Of Integrated Office Complex At The Existing Dtc Depot, Ip Estate, New Delhi. S/H : Composite Works Of Construction Of Dtc Hq Building (2B+G+11 Stories) With Reinforced Cement Concrete Framed Structure Design Including Water Su

Issued by Government Departments · Delhi, Delhi
Tender Value
128.23 Crore
Estimated cost
Bid Submission
22 Oct 2026
31 days left
EMD
1.38 Crore
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of Integrated Office Complex At The Existing Dtc Depot, Ip Estate, New Delhi. S/H : Composite Works Of Construction Of Dtc Hq Building (2B+G+11 Stories) With Reinforced Cement Concrete Framed Structure Design Including Water Supply, Sanitary Installation, Internal And External Electrical Installations, Firefighting, Av System, Access Control, Cctv System, Lifts, Lan Bms, Hvac (Low Side & Hi Side) Horticulture Works, Vertical Plantation Works, Artworks, External Development Works And All Other Related Works All Complete Including 3 Year Dlp At Dtc Bus Depot At Ip Estate, New Delhi.

BOQ

Name of Work:- Development of Integrated office complex at the existing DTC Depot, IP Estate, New Delhi. S/h : Composite works of Construction of DTC HQ Building (2B+G+11 Stories) with RCC framed Structure design including water supply, sanitary installation, internal and external Electrical installations, Firefighting, AV system, Access control, CCTV System, Lifts, LAN BMS, HVAC (Low side & Hi Side) Horticulture works, Vertical plantation works, Artworks, External development works and all other related works all complete including 3 year DLP at DTC Bus Depot at IP Estate, New Delhi.
Sl. No. Item Description
1Sub Head- I Earth Work Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and 1.5m lift, disposed earth to be levelled and neatly dressed.All kinds of soil
2Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materialsAll kinds of soil
3Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
4Extra rates for quantities of works, executed: In or under water and/or liquid mud, including pumping out water as required
5Constructing cast-in situ RCC diaphragm wall by providing and laying machine batched, machine mixed, self compacting, ready mix reinforced cement concrete, tramie controlled, of M 30 grade using minimum 400 kg. cement per cum of concrete including providing and mixing Required admixtures in recommended proportions as per IS : 9103, as approved by the Engineer-in-charge, for achieving 150- 200mm slump, for diaphragm wall having thickness as per approved structural design not exceeding 600 mm, in pannels of required depth and lengths as per approved drawing, including constructing necessary guide walls as required and as specified including boring in all kinds of soils and rocks,including working in or under water and / or liquid mud, in foul conditions and pumping or bailing out of water and removing slush, including disposal of earth/ rock / slush etc. for all leads and all lifts, including preparing,providing and re-circulating bentonite slurry in the trench as and when required for all depths, including agitating bentonite slurry during trenching etc., providing and fixing stop ends or form tubes, upto the required depth of diaphragm wall including extracting the same after casting,including chipping off the bentonite adulterated concrete or unsound concrete up to the cut off level for obtaining the sound concrete, dressing undulations on the exposed face of diaphragm wall after excavation by chipping / chiseling etc. including filling the depression/ cavities with sound concrete etc. complete and as directed by the Engineer-in-charge,including providing recess for bearing plates and fixing insert boxes for inclined rock anchors etc. complete as per the specifications and approved design and as directed by the Engineer-in-charge, but excluding the cost of reinforcement and inserts.
6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
7Supplying and filling in plinth with jamuna sand under floors including, watering, ramming consolidating and dressing complete.
8Carriage of excavated surplus earth including loading unloading and stacking lead up to 5km.
9Carriage of excavated surplus earth including loading unloading and stacking lead beyond 5KM upto 10km per km
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6graded stone aggregate 40 mm nominal size derived from natural sources)
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
12Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
13Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) including the cost of required centering, shuttering complete. 1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone -III) Drived from Natural Sources : 3 graded stone aggregate 20mm nominal size Drived from Natural Sources).
14Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.
15Making plinth protection with 40mm thick fine dressed white/red sand stone in approved pattern over & including 50 mm thick base concrete with 1:3:6 6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. including Brick edging .
16Providing and filling in Aereated block bats (broken pieces ) in single or multiple layers in super structure , filling the joints with sand mortar ( not more than 20%)20mm thick cement sand mortar screed in proportion of 1:6 shall be laid asper drawing. Crushing strength of aerated concrete block /bats shall not be less than 40 kg/sqcm, minimum density in dry oven condition between 651 to 750 kg /cum, thermal conductivity shall not exceed 0.3W / mk, fire resistance 4 hours , in line and plumb , cleaning the surface with tools and tackles , at all level, all height , all floors including curing , scaffolding , complete as per specifications , drawings and directed by engineer in charge.
17Extra for Concrete work in super structure above floor V level for each four floors or part thereof.
18Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
19Walls ( any thickness) including attached pilasters, butteresses, plinth and string courses etc.
20Suspended floors, roofs, landings, balconies and access platform.
21Lintles, beams, plinth beams, girders, bressumers and cantilevers.
22Columns, Pillars, Piers, Abutments, Posts and Struts.
23Stairs, (Excluding landings) except spiral -staircases.
24Edges of slabs and breaks in floors and walls. Under 20 cm wide
25Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m for every additional height of 1 metre or part thereof (Plan area to be measured.) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
26Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level : Thermo-Mechanically Treated bars.
27Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars.
28Extra for laying reinforced cement concrete in or under water and/ or liquid mud including cost of pumping or bailing out water and removing slush etc., complete.
29Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting= of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works up to Plinth level.
30Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting= of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works above plinth & up to floor V level.
31Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)
32Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-35 is @ 350 kg/ cum)
33Providing M-50 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-50 is @ 380 kg/ cum)
34Add for using extra cement in the items of design mix over and above the specified cement content therein.
35Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
36Providing and fixing tapered / parallel threaded couplers conforming to IS code on \\"Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement – Specification\\", to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works per direction of Engineer-in-Charge . (The length of the bars in which coupler is to be provided should not be less than 4 metre, no deduction for labour and binding wire saved for not providing lap length shall be made). Coupler for 20mm dia meter reinforcement bar
37Providing and fixing tapered / parallel threaded couplers conforming to IS code on \\"Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement – Specification\\", to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works per direction of Engineer-in-Charge . (The length of the bars in which coupler is to be provided should not be less than 4 metre, no deduction for labour and binding wire saved for not providing lap length shall be made). Coupler for 25mm dia meter reinforcement bar
38Providing and fixing tapered / parallel threaded couplers conforming to IS code on \\"Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement – Specification\\", to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works per direction of Engineer-in-Charge . (The length of the bars in which coupler is to be provided should not be less than 4 metre, no deduction for labour and binding wire saved for not providing lap length shall be made). Coupler for 32mm dia meter reinforcement bar
39Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
40Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand)
41Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.
42Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry .
43Brick work with modular calcium silicate bricks machine moulded conforming to IS:4139-1989, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
44Extra for modular calcium silicate brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level for each four floors or part thereof by mechanical means.
45Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
46Providing and fixing dry cladding upto 10 metre heights with 30 mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone
47Providing and fixing dry cladding upto 10 metre heights with 30 mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30mm thick gang saw cut stone
48Providing and fixing structural steel frame (for dry cladding with 30mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S.brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc.shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-chargefor approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
49Providing and fixing adjustable stainless steel cramps of approved quality,required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge
50Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases.
51Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of.
52Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing wall surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge
53Stone work (machine cut edges) for wall lining etc. (veneer work) upto10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backingand the sides by means of cramps and pins which shall be paid for separately) : Gang saw cut stone-30mm red sand stone
54Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm.
55Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm.
56Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) Granite of any colour and shade as per selection of client for wall lining (veneer work), /bands 200mm wide backing filled with a grout of average 12 mm thick in polymer modified adhesive mortar including secured to the backing by means of cramps, hold fastners ,copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in adhesive mortar including making the necessary chases complete in all respect.
57Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
58Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
59Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
60Supply and install modular toilet cubicles of MERINO-BESCO make 'ATHENA LITE- SS' series as per manufaturer's std specifications. Toilet cubicles should be free standing without any support from bottom. All intermediate panels, pilasters, doors shall be made up of 12mm thick Solid Compact Laminate (Phenolic Core Board) as per IS 2046 based on thermosetting resins, homogeneously reinforced with cellulose fibers making cubicles impervious to Water, resistant to Fire, etc. Compact laminate should be Greenguard and IGBC certified.All Hardware, fixing and its accessories shall be of Merino's Grade 304 stainless steel except Aluminium top rail and door stopper channel. The pilaster is slotted & affixed to the top rail and secured from the top of the the top rail. Its top rail shall be extruded anodized or Epoxy poweder coated grade 6063 T5-15 micron Aluminium of dimensions 125mm x 70 mm x 5 mm thick. The top rail shall be fixed to the wall on both sides using MS- wall brackets. The intermidiate panel shall be anchored to the wall and pilasters with SS 304 grade U channels with doors fixed to pilaster.Std accessories include SS 304 grade Hinges, SS 304 grade Door knob,SS 304 grade thumb turn indicator, Zinc based coat hook, Aluminium Door Stopper channelAthena Lite- SS Series Cubicles- Std Sizes (W x D x H)- 900 mm x 1550 mm x 2105 mm, (Height is including 150 mm gap from bottom) Door Size- 600 mm.
61Providing and fixing Factory Pressed Laminated BWP Grade Flush Door as per IS 2202 (Part1):1999, Green guard & FSC certified, from solid wood timber, 3.6 mm hard core and Gurjan face, matched commercial 3 ply veneering with vertical grains & cross bands, face veneers on both faces of shutters providing structural strength and dimensional stability, immune to termites and borers, Bonded with Phenol Formaldehyde resin, with joint less High Pressure Laminate IS 2046 -95, 1mm thick both sides including edges . 35 mm thick including ISI marked Stainless Steel ball bearing hinges with necessary screws.
62Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete.
63Providing and fixing 250x16mm Stainless steel (Grade 316 ) satin finish sliding door bolts superior quality with necessary SS screws etc. complete:Heavy Duty
64Providing and fixing stainless steel tower bolts ( (Grade 316 ) satin finish with necessary accessories and SS screws etc. complete. 300 x10 mm
65Providing and fixing stainless steel tower bolts ( (Grade 316 ) satin finish with necessary accessories and SS screws etc. complete. 150 x 10 mm
66Providing and fixing 25mm dia , 300 mm long in cranked / square shape stainless steel (Grade 316 ) satin finish pull handle with necessary screws etc. complete
67Providing and fixing high quality hanging floor door stopper of zinc metal in stainless steel satin finish with sprung function and enhanced with high quality fixing screws and high grade PVC/ rubber strongly fixed on the rod to make better grip of door on floor complete, of approved make.
68Providing and fixing fire resistant door frame of sections 50x60mm/35x60mm / 60x70mm having built in rebate made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes fire rated glazed door shutters/ partitions . The frame shall be filled with Mineral wool insulation having density min 96 kg / cum. The frame will have a provision of GI anchor fastners at locations as directed by engineer in charge of size M10x80 suitable for fixing in the opening along with factory made Template for SS Ball bearing Hinges of size 100x89x3mm for fixing fire rated glazed shutter if required. The frame shall be finished with a approved fire resistant primer or powder coating of not less than30micron in desired shade as per direction of Engineer-in-charge (Cost of SS ball bearing hinges is excluded).
69Providing and fixing 60mm thick glazed fire resistant door shutters of 120 minutes fire rating confirming to IS:3614 (partII) or EN 1634-1:1999, tested and certified as per laboratory approved by Engineer in charge, with suitable mounting on door frame, consisting of vertical styles, top rail and side rails 60x60mm wide and bottom rail of 110x60mm made out of 1.6mnm thick GI sheet ( zinc coating not less than 120gm/sqm), duly filled mineral wool insulation having densitymin 96 kg /cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat approved fire resistant primer or powder coating of not less than30micron in desired shade as per direction of Engineer-in-charge. ( Panelling to be paid for seperately).
70Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
71Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
72\\"Providing and fixing factory made ISI marked partially insulated metal fire rated door set assembly, for staircase / exit pathway and refuge areas applications. Consisting of galvanized iron steel frame and single/double leaf shutter including necessary hardware accessories conforming to FD 120 Pl classification of IS 3614 : 2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI sheet with minimum 120 GSM Zinc coating as per IS 277. The entire fire rated door set assembly shall be tested in latched condition as per IS 17518 (Part -1) :2022Frame : The frame shall be of minimum size 90 X 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitered cut joint (self tab. Screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E-84 of minimum size 10x4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonry wall opening with CSK/Hex headed fastner of minimum 8mm dia size and minimum 80mm long with 8mm dia Polyamide sleeves @ 5 numbers at each on vertical sides and 2 numbers on horizontal top side.\\"\\"Door Shutter:The double skinned single leaf partially insulated fire rated door shall be consisting of minimum 50mm thick and having box like structure, slots cut and holes punched, for fixing of hardware’s with stiffners as per IS: 16074 including resin bonded mineral wool / ceramic wool infill material of minimum density 96 kg/cum. Door leaf shall be provided with vision panel, having maximum area of 0.06 sqm. of 120 minute fire rated maximum 6mm thick clear borosilicate glass pane with clip-on arrangement and fire rated ceramic tape having maximum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of maximum size of 15x1.5mm or all of size as per test evidence shall be fixed on all the three edges of the door leaf. The door shutter shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN1935:2002 or butt hinges as per IS 12817 of minimum size of 100x75x3mm @ 5 numbers hinges upto 2400mm height or as per test evidence whichever more fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. \\"\\"Hardware Accessories:Fire door set assembly shall be provided with one number of single point Panic push bar (cross bar) device of desired finish as per EN1125 and one number external trim including half cylinder of 42mm long with one side key as per EN1125. One no. heavy duty door closer of size EN 3.5 with standard arm, of desired finish (suitable upto 1250mm door width) conforming to IS 3564/EN 1154.Finishing Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13817 of approved colour and shade all complete as per manufacturer’s specifications and as per direction. Of the extinguishing type polyurethane installation: The hollow space in the door frame shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacture. \\"Double leaf Partially insulated metal fire door set of FD 120 PL classification with 120 minutes integrity and 30minutes insulation as per IS 3614:2021 – For Staircase Exit pathway / refuge area etc.
73Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
74Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece
75Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
76Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 – part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25mm M.S. laths with 1.25 mm thick top cover.
77Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 – part 1 and M.S. top cover of required thickness for rolling shutters. Providing and fixing ball bearing for rolling shutters.
78Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.0 sqm and upto 16.80 sqm in the area.
79Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-charge. (area of grill to be measured).
80Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes.
81Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.
82Providing and fixing carbon steel galvanised ( minimum coating 5 micron ) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x80 mm
83Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per architectural drawing and approval of Engineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
84Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required as per architectural drawing In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
85Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required as per architectural drawing In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
86Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primeras per architectural drawing. M.S. tube.
87Design, fabrication, supply, installation, and testing of DTC logo signage (illuminated type) made of 5 feet high letters/logo at terrace level. The logo shall be fabricated from laser-cut acrylic sheet / ACP panel / SS frame, back-mounted on MS frame with weatherproof powder coating, and fitted with IP65-rated LED modules (internal or backlit as per design). Signage to be securely installed on the terrace with necessary steel supports, wiring, drivers, anchoring system, etc. Complete in all respects, including structural stability and electrical connections, as per approved design and instructions of the Engineer-in-Charge.
88Design, manufacture and installation of 12 mm dpi system, a complete assembly of extruded Multi / Micro cellular profile UV extruded/protected polycarbonate panels incorporated into a complete system. The Polycarbonate panel system consists coextruded UV protected Multi / Micro cellular structure polycarbonate panel with width of 1040 mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam with standing seam height of 10 ‐ 15mm at both sides of the panel. Panels shall be fixed on Purlins with the Z ‐ Type Stainless Steel Fastener/retention clips and connectors. Each fastener shall be min 1mm thick of SS 304 Grade and secured to supporting frame/structure with min 3 numbers of self‐drilling screws so that the Pull Out Load of Fastener exceeds 7000 N (7 KN) when tested as per ISO 6892: 1998 and IS 1608: 2005. Snap‐on connectors to interlock the panels shall have 2‐4 teeth grip‐lock locking mechanism to ensure maximum uplift capability. Panel shall be fixed with additional End cap/Aluminum U / F Profile / Glazing Bar (mill finish) for ends as required. Panel shall be fixed over structural steel / MS purlin (paid separately) by trained & factory authorised installer under direct supervision to complete entire project installation according to the detail technical specifications as per approved architectural drawings.
89Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete 40mm thick with 20mm nominal size stone aggregate
90Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately)
91Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : Dark shade pigment using ordinary cement
92Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : Dark shade pigment using ordinary cement
93Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
94Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
95Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
96Extra for pre finished nosing in treads of steps of marble /granite stone slab
97Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
98Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
99Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
100Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent
101Granite stone 18mm thick machine cut and mirror polished granite stone slabs of required size and shape (sample of granite shall be approved by Engineer-in-charge) in risers of steps , skirting,dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with white cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
102Extra for making edge chamfered of kota stone skirting as per drawing
103Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof
104Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over P.V.C. sheet 1mx1mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete.
105Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 110 mm diameter.
106Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110
107Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
108Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe 110 mm shoe
109Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
110Providing and fixing to the inlet mouth of rain water pipes cast iron grating 15 cm diameter and weighing not less than 440 grams.
111Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring 'T' with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
112Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge.
113Providing & fixing Armstrong Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063. The baffle blade shall be in size of 100x 50mm in WHITE/BLACK/WOOD GRAIN finish – Pradoo & Cabrueava. The baffle blade shall be suspended using Slotted U-profile at on-center spacing . Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. Baffle Ceiling 200mm c/c.
114Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement , all complete as per direction of Engineer-
115Providing and fixing of TRANQUIL size 1200x1200x 24mm thick Ecocore Acoustical Baffle/Cloud ceiling formed out of 2 nos of 12mm thick sandwiched acoustic pet panels. Acoustical Cloud are hung to true ceiling with proprietary adjustable string and fasteners connected to customised SS,brackets fixed in the panel etc., complete as per the detailed drawings and as per the directions of Engineering incharge
11612 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
11715 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
118Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12mm cement plaster
1196 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
120Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
121White washing with lime to give an even shade: New work (three or more coats)
122Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification New work (two or more coats) over and including water thinnable priming coat with cement primer
123Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacture
124Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
125Applying priming coat with primer of approved brand and manufacture having low VOC (Volatile Organic Compound) content With water thinable cement primer on wall surface having VOC content less than 50 gm/litre
126Providing and applying acrylic aggregate textured non pigmented wall finish coating in 100% natural/ non pigmented Crushed Stone finish, dispersed in a pure acrylic binding medium, incorporating anti cracking, anti rusting, defoamers, antifungal compound followed by trowel/ spray gun application in approved shade and pattern or brick pattern with an average thickness of 1.75-2.0 mm, product finally sealed with protective top coat as per sample approved by Engineer-in-charge on the exterior walls of the building
127Providing and fixing G.I. Hexagonal chicken wire mesh of size 12mm x 22 gauge at the junction of dissimilar surfaces of brick/block masonry wall and RCC column/beams and the like including necessary \\"U\\" nails for fixing, overlapping etc. complete all as per specification and as directed by the Engineer for all floors and at the height.
128Providing and fixing of 8mm thick annealed premium GRIHA rated lacquered glass of approved color by Architect/ Client /, fixed with compatible neutral core silicon / double sided tape on a perfectly leveled 12mm thick water proof plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure complete as per direction of engineer in charge.1. Lacquered glass must be made industrially (via curtain coating process); opaque (if viewed against a support wall), coated with PU lacquer (25 micron thick); 2. color consistency (measured by Minolta spectrophotometer CM5081); 3. highly durable (passes PERSOZ hardness test for minimum 220 oscillatios); 4. humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, no formaldehyde); 5. appropriate recycled content (12% post industrial / 6% post consumer); compressive strength (1000 MPa) & tensile strength (40 MPa),same as float glass;
129Supply, fabrication, and installation of wash basin counter made of 12mm thick REHAU Mineral Acrylic Solid Surface, 100% acrylic-based, non-porous, homogeneous material, including all necessary cutting, edge finishing, sink cut-outs, and color-matched seamless jointing using REHAU-approved adhesive. The work shall include provision of substructure support frame (moisture-resistant plywood or galvanized MS brackets), backsplashes (if required), and all accessories, tools, consumables, and labor to complete the installation in accordance with manufacturer’s specifications and project drawings
130Providing sprayable Fire-rated joint spray Hilti CFS SP WB to seal gap between horizontal slab & curtain wall to provide minimum 2 hours of fire rating when tested as per ASTM E 2307 standard. Fire rated Joint spray will be applied over the packing material. The packing Material should be minimum 4 Inch thick, 4 PCF (64kg/m3) density, mineral wool batt insulation. Installed with the fibers running parallel to the slab edge and curtain wall. The packing material shall be compressed upto 30% in the nominal joint width. Compress the batt insulation into the perimeter joint such that the top surface of the batt insulation is flush with the top surface of the concrete floor slab. The product to have upto +_ 12.5 % Movement Capability . Curtain Wall Insulation:- For Complete System performance , we recommend to install 3 inch Thick ( 75mm) & 8pcf Density mineral wool bat spandel Insulation and should be secured with Impailing pins. and L-angle stiffener or Steel back pan on the slab side of spandrel for insulation rigidity. (This will be in the scope of the contractor.) System Qualification:- The system shall be UL listed & Classified and product shall bear the UL and FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer. A firestop submittal shall be produced by manufacturer , in accordance with approved passive fire protection method statement, for technical approval. Firestop installation shall be done by certified & Licensed Hilti Accredited Firestop Specialty Contractor (HAFSC), or necessary Firestop Installer training provided for specific project/application to install in accordance with Hilti guidelines and UL system test certificates or approved EJ document. Firestop Speciality Contractor needs to submit work completition certificate along with installation report through Hilti documentation Software FIELDWIRE for periodic inspection & maintenance purpose.
131Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
132For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
133Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.50 mm thickness.
134Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & floor spring and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
135Providing and fixing stainless steel handle H Pull Handle Back To Back Fixing 25mm Dia X 450C/C X 600 O/A Max. Door Thickness - 55mm SS 304 SS M Hafele article code (903.11.452) or equivalent make with necessary screws etc complete as per the architectural drawings and the directions of engineer-in-charge.
136Providing and fixing stainless steel Corner patch lock with cylinder for 10-12 mm glass, SS Matt Hafele article code (981.50.030) or equivalent make including necessary cutting and making good the door etc complete: as per the architectural drawings and the directions of engineer-in-charge.
137Providing and fixing stainless steel Bottom patch fitting,for 10-12mm glass, SS Matt Hafele article code (981.50.010) or equivalent make including necessary requirements etc all complete as per the architectural drawings and the directions of engineer-in-charge.
138Providing and fixing stainless steel Top patch fitting for 10-12mm glass, SS Mat Hafele article code (981.50.020) or equivalent make including necessary requirements etc all complete as per the architectural drawings and the directions of engineer-in-charge.
139Providing and fixing stainless steel Side panel patch fitting for 10-12 mm glass,SS Matt Hafele article code (981.50.040) or equivalent make including necessary requirements etc all complete as per the architectural drawings and the directions of engineer-in-charge.
140Providing and fixing stainless steel Top Patch for Fixed Glass Panel on Top & Side for 10 to 12mm Glass, SS Mat Hafele article code (981.00.060) or equivalent make including necessary requirements etc all complete as per the architectural drawings and the directions of engineer-in-charge.
141Providing and fixing stainless steel FS302, Size 3, Double cylinder floor spring with 90° hold open and SS 304 Cover plate(Without Accessories),Max. door leaf weight 100 Kg,SS Matt, For door width 850-1000mm Hafele article code (932.00.015) or equivalent make including necessary requirements etc all complete as per the architectural drawings and the directions of engineer-in-charge.
142Providing and fixing stainless steel Floor Mounted Door Stopper Half Round SS 304 SS Hafele article code (937.55.140) or equivalent make including necessary requirements etc all complete as per the architectural drawings and the directions of engineer-in-charge.
143Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width.
144Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 355 X 19 mm
145Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 510 X 19 mm
146Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved makeconforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately).
147Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
148Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness,pressure equalisation & drainage and protection against fire hazard including:\\"b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.\\"\\"c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, settingblocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.\\"d) Providing and fixing in position flashings of solid aluminium sheet 1mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.e) Making provision for drainage of moisture/ water that enters the curtainglazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services,scranes or cradles etc. as described above and as specified . The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories\\"1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing method for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing method for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”\\"
149Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal(structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall beassembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of previous item) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
150\\"Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc.including:\\"a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
151Luxalon® Aluminium Panel V-1 Louvered System with 84R Plain Panels. Supply and Installation Luxalon V-1 Louvers in 84R Plain Panel manufactured by M/s. Hunter Douglas India Pvt. Ltd. of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6mtrs coil coated on a continuous paint line double baked and roll formed from enameled corrosion Resistance Aluminium Alloy AA3105 (Al.Mg.) for higher strength and good Roll forming characteristics. Panels shall be clipped to baked enameled Aluminium V-1 panel stringer 33mm wide and 48mm deep x 0.95 mm thick in a standard length of 5mtrs made of double baked enameled Aluminium Alloy (Al.Mg.) white/black to hold the panel in a module of 146 mm centre to centre .V1 Stringer shall be fixed at 150 mm from panel ends and at a distance of maximum 900-1000 mm center to center across the panel span. The carrier shall be fixed to a suitable structure by means of rigid fixing details. All properties and specifications shall comply with ECCA directives and more specifically with CEN standard EN 1396:1996. Paint Finish: -Panel shall be stove enamelled and finished with Luxacote, a patented special three layered coating system (consisting of first a conversion layer of thickness 800-2000mg/sq mtr, a polyurethane basecoat of 16-20 microns, and a special top coat of polyamide particles of 8-12 microns thick to provide excellent abrasion and damage resistance) in a continuous coil coating process of the approved colour on the exposed side and the reverse side with epoxy. Make in India: The manufacturer should have manufacturing plant in India to the promote make in India products as per the latest directives of Government of India. High Precision High Speed Cold Roll Forming : The panels shall be manufactured on high precision & high speed roll forming machine to control product diamensional tolerance within limits and achieve consitent quality product. Experience : The manufacturer should have minimum experience of 7 years in similar product manufacturing pplication in India. Quality Management System : The company should have own Manufacturing Plant with QC Laboratory. ISO Certification - ISO 9001: 2015 Quality Management System Certification shall be mandatory. Sustainability: Green Building Certification / The manufacturer should be able to submit 'IGBC GreenPro Certificate' for the product proposed for green building certification. Fire Rating : Product should comply with per BS 476 Part 6 & Part 7. two panels). Slotted Fastening Profile shall be fixed at 150 mm from panel ends and at a distance of maximum 1200 mm center to center across the panel span and in any height and Slotted Fastening Profile shall be fixed to a suitable sub-structure by means of Square Brackets.Paint Finish:Panel shall be stove enamelled and finished with Luxacote, a patented special three layered coating system (consisting of first a conversion layer of thickness 800-2000mg/sq mtr, a polyurethane basecoat of 16-20 microns, and a special top coat of polyamide particles of 8-12 microns thick to provide excellent abrasion and damage resistance) in a continuous coil coating process of the approved colour on the exposed side and the reverse side with epoxy
152Supply and Installation of Quadroclad Honeycomb panels cladding system of 12mm thick panel consisting of two skins of flat smooth Aluminium alloy, with an outer skin thickness of 0.7 mm and inner skin thickness of 0.5mm. The panels are made up of pre-coated coils.Coils are coated on a continuous paint line. The panel coils are levelled on advanced cad/cam equipment to achieve levelling through arku six hi configuration roller levelling process to ensure the flatness of the coil in the manufacturing process and relieve stresses of coil. Panel shall be factory manufactured to the required width subject to a maximum width of 1000mm and to the required lengths subject to maximum of 4500 mm and shall essentially have each 12mm thick panel with closed panel edges & two side rolled formed to J groove to receive the “M” clamp. The Quadroclad Honeycomb panels shall be high pressure pressed in controlled factory conditions with two-part high temperature cured PU glue. The core of honeycomb Aluminium shall have a core diameter of 19mm and min. foil thickness of 0.076 mm. The 12mm thick panel will be finished on the exterior/exposed surface with coil coated finish, and on the inner surface with primer coil coating. The 12mm thick panels shall be secured to suitable aluminium sub frame or/and steel sub-structure (to be paid extra in aluminium & steel works). The panels shall be secured to the above support allowing for expansion by means of aluminium “M” clamp at a distance of 600 – 750 mm c/c based on each pane length or as per manufacturer design as per site requirement. The 15-20mm wide joint shall be filled up with suitable weather sealant. The product shall have GreenPro certification by CII-Green Products and Services Council. The panels shall be Tested for Seismic Zone V compliance as per IS 1893 part 1-2016. Manufacturer shall comply with ISO 9001:2015 quality management system. To comply with make in India initiative by govt of India, manufacturer shall have manufacturing unit in INDIA for minimum 10 years. All the works complete as per specifications, drawings and as directed by Engineer-in-charge. Measurements shall be wall to wall, measuring the installed surface area without any deductions for lights, diffusers, columns, or any other openings etc. All the works complete as per specifications, drawings and as directed by Engineer-incharge. Approved Makes: Hunter Douglas, Colt, Renso
153Glass Railing : Providing & Installation of Dorma or equivalent Modular (weld free Components base) Balustrade & Handrail system, 50.8 mm dia x 1.6mm thick handrail fixed to the Balustrade of 50 .8 mm dia x 1.6 mm thick with top adapter( neck) type(Dorma Art no. 9180205) fixed with 2nos of M4x10mm Allen CSk Screw. The balustrade fixed to Top of the straight or staircase with Base plate with M12 x120mm long anchor fastener. The balustrade C/C 900 to 1000mm, The Ht. of the handrail 1000mm from FFL. Glass infill of 6,8 &10 mm thick toughened monolithic Glass or 13.52 thick laminated toughened glass is Fixed to the Balustrade with Glass Clamp(Dorma Art no. 9101000000579) (Four per balustrade) by M8 avdel insert (Dorma Art no. 9180166) & M8 x25mm Allen cap screw , Complete with all End cap (Dorma Art no. 9180208), Mid Span Sleeve(Dorma Art no. 9180302), Elbows. All the material of handrail, balustrade and components should be of SS 304 grade satin finish.
154Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.
155Providing & laying in position PVC sheet with 400 micron thick, laid over base concrete ( overlap at joints of PVC sheet should be minimum 100mm wide & pasted to each other with bitumen @ 1.7kg/sqm ) including cutting of sheet complete.
156Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone
157Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area.iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
158Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in- Charge.charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120mm and minimum thickness at khurra as 65 mm.
159Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3mm thick
160Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation
161Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
162Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm
163Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R2010 i.e. by reducing permeability of concrete by more than compared with control concrete as per DIN 1048 and resistant to 16bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
164Designing, providing & installing prestressed permanent ground anchor of following capacities in accordance with BS : 8081 & specification based on the provided data such service life of anchor,design load, soil investigation report using prestressing steel with minimum fixed length of 10metre or more depending upon pull out criteria. Rate shall include drilling through over burden, all types of soil, weatherd/hard rock with either rotary/Pneumatic percussion method, flushing the whole, fabrication & installing of anchors, stressing of anchors after the grout achieving its strength to its capacity level & anchoring to the desired locking force level, providing adequate corrosion protective etc ( including supply of cement ). Hole dia shall be 100mm, system 3T15. 40tonne capacity permanent anchor ( minimum 10m free length + 10metre fixed length or as per Design ) as per Design and as per engineer incharge
165\\"Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required,laying at site, spreading and compacting mechanically by using needle and surface/ screed vibrators, vacuum de-watering process, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars considered under relevant item separately).(Note :- Cement content considered in this item is @ 340 kg/cum & Excess cement beyond this is considered under relevant item). Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer
166Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
167Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge Using grade 'A' sealing compound conforming to IS: 1834.
168Providing and laying factory made coloured chamfered edge Cement Concrete paver blocks/ Grass Crete of required strength, thickness & size/shape,made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications & direction of Engineerin- Charge. 80mm thick C.C. paver block of M-35 grade with approved colour, design & pattern.
169Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in charge and accordance with applicable specifications
170Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement :3 coarse sand) including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete etc. as per direction of Engineer -in -charge ( Length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer -in -charge.
171Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
172Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
173Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum,optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge
174Providing and erecting upto 10.00 metre high temporary barricading at site;each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion.Rate include its maintenance for damages, painting, all incidentals,labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineerin- Charge. rate taken from DSR 2016 16.81 2mtr high =1577.05/mtr for change in the sqm rate (1577.05/2=788.53/sqm)
175Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
176Supplying and stacking of good earth at site including royalty and carriage up to 5 km (earth measured in stacks will be reduced by 20% for payment).
177Supplying and stacking at site dump manure from approved source, including carriage up to 5 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20mm
178Fine dressing of the ground
179Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).
180Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
181Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). In rows 5 cm apart in both directions
182Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing withsludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc.including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
183Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.
184Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 1.2 m dia and 1.2 m deep
185Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 60 cm dia, and 60 cm deep
186Providing and display of Aglaoneama Jungle plant of ht 1' and above having 3 in 1 with 20-25 leaves,fresh and healthy leaves , well developed in 10\\" E/pots & as per direction of the officer in charge.
187Providing and display of Aglaoneama Ernesto plant of ht 1.5' and above having 3 in 1 with 18.20 leaves,fresh and healthy leaves , well developed in 10\\" E/pots & as per direction of the officer in charge.
188Providing and display of Araucaria Cookie plant of 2.5' - 3' ht straight ,fresh and healthy lush green leaves from bottom to top, well developed in 10\\" E/pots & as per direction of the officer in charge.
189Transplantation of trees with in a distance of 2km including excavation around existing tree, pruning of branches, lifting, loading and transportation of existing tree, digging pits for placing tree at new place, adding manure, sand, fertilizer, hormones and bio fertilizer to it. Levelled and neatly dressed and disposal of surplus materials from old existing and new sites to designated place. Each tree should be firmly secured to the stake so as to prevent excessive movement, flooding with water, treatment of roots, rope and gunny bags as per direction of the officer incharge. T&P and all required materials shall be arranged by the contractor and nothing extra shall be paid on this account. Girth of tree shall be measured at a height of 1m above ground level. Girth of trees beyond 50cm and upto 90cm.
190Transplantation of trees with in a distance of 2km including excavation around existing tree, pruning of branches, lifting, loading and transportation of existing tree, digging pits for placing tree at new place, adding manure, sand, fertilizer, hormones and bio fertilizer to it. Levelled and neatly dressed and disposal of surplus materials from old existing and new sites to designated place. Each tree should be firmly secured to the stake so as to prevent excessive movement, flooding with water, treatment of roots, rope and gunny bags as per direction of the officer incharge. T&P and all required materials shall be arranged by the contractor and nothing extra shall be paid on this account. Girth of tree shall be measured at a height of 1m above ground level. Girth of trees beyond 90cm and upto 150cm.
191Transplantation of trees with in a distance of 2km including excavation around existing tree, pruning of branches, lifting, loading and transportation of existing tree, digging pits for placing tree at new place, adding manure, sand, fertilizer, hormones and bio fertilizer to it. Levelled and neatly dressed and disposal of surplus materials from old existing and new sites to designated place. Each tree should be firmly secured to the stake so as to prevent excessive movement, flooding with water, treatment of roots, rope and gunny bags as per direction of the officer incharge. T&P and all required materials shall be arranged by the contractor and nothing extra shall be paid on this account. Girth of tree shall be measured at a height of 1m above ground level. Girth of trees beyond 150cm.
192Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material Beyond 30 cm girth upto and including 60 cm girth
193Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material Beyond 60 cm girth upto and including 120 cm girth
194Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material Beyond 120 cm girth upto and including 240 cm girth
195Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material Above 240 cm girth
196Providing and display of Seaporthia Palm Plant having height 3' to 4; with 3-4 suckers ,fresh and healthy leaves from top to bottom lush green leaves , well developed in 8\\" plastic pots /E. pots & as per direction of the officer in charge.
197Demolition Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix)
198Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
199Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
200Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
201Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
202Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
203Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area beyond 3 sq. metres
204Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
205Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles 10 mm to 25 mm
206Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
207Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in charge.
208Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
209Credit Credit for purchase of material obtained after demolition( below mentioned items after dismantlling shall be the property of the contractor FireCheck Door including Frame
210Wooden Flush Doors
211Aluminium Doors and Window Frame
212Structural steel
213Reinforcement steel
214C.P Fittings
215GI pipe of any diameter
216CI Pipe of Any Diameter
217Bricks
218Sub Head – XVI Sanitary Installation Providing and fixing white vitreous china wall mounting water closet of size 500x370x380 mm of approved shape including providing & fixing coneled cistern with dual flush fitting, of flushing capacity 2 litre/ 4 litre (adjustafle to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
219Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixturescomplete including cutting and making good the walls and floorswherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
220Providing and fixing Handicap toilet consisting of 1 no. EWC with vitreous 10 litre capacity dual flushing system cistern with 1 no. hinged rail of 76 cm, 1 no. wash basin with all fittings and bottle trap, with one pair of mounting brackets and 4 nos. grab rails, 1 no. tower ring and 1 no. paper holder all complete as per the manufacturer's specification
221Providing and fixing white vitreous china battery/electric based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge..
222Providing and fixining frameless urinal partition with 8 mm glass , full height upto 3 feet, 1 feet deep & SS fittings approved make all complete as directed by the Engineer-in-Charge.
223Providing and fixing white glazed Vitreous China wash basin (\\"Hindware\\" Model No. 10080 of size 580 x 430 mm) or equivalent. under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including painting of fittings and brackets, cutting and making good the walls wherever required all complete (Make Parryware / Hindware / Kohler) , Pillar cock Jaquar Model No. LYR - 38037 .
224Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia
225Providing and fixing beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
226Providing and fixing soil, waste and vent pipes : 100 mm dia. centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989.
227Providing and fixing soil, waste and vent pipes : 75 mm dia. centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989.
228Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : for 100 mm dia. Pipe
229Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : for 75 mm dia. Pipe
230Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989
231Providing and fixing plain bend of required degree. 100 mm Sand cast iron S&S as per IS : 3989
232Providing and fixing plain bend of required degree. 75 mm Sand cast iron S&S as per IS : 3989
233Providing and fixing heel rest sanitary bend 100 mm dia Sand cast iron S&S as per IS - 3989
234Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm Sand cast iron S&S as per IS - 3989
235Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75x75x75 mm Sand cast iron S&S as per IS - 3989
236Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x75 mm Sand cast iron S&S as per IS - 3989
237Providing and fixing terminal guard: 100 mm Sand cast iron S&S as per IS - 3989
238Providing and fixing terminal guard: 75 mm Sand cast iron S&S as per IS - 3989
239Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm SS 304 grade coupling with EPDM rubbergasket
240Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 75 mm SS 304 grade coupling with EPDM rubbergasket
241Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 100 mm
242Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 75 mm
243Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989.
244Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989. Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 100 mm diameter pipe
245Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989. Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 75 mm diameter pipe
246Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge.
247Providing and fixing G.I floor drain consisting of 100x50mm G.I elbow (grating and G.I pipe to be paid separately), complete as per instructions.
248Providing and fixing 125 mm dia S/S grating (with or without hole)for floor or Nahani trap.( Cat No -Chilly-PSCO5 of Jaquar / Jayana or Equivalent )
249Providing and fixing of G.I pipe for waste water in wall/ floor , cutting chases and making good/ concrete covering etc complete. 32 mm dia nominal bore
250Providing and fixing of G.I pipe for waste water in wall/ floor , cutting chases and making good/ concrete covering etc complete. 40 mm dia nominal bore
251Providing and fixing of G.I pipe for waste water in wall/ floor , cutting chases and making good/ concrete covering etc complete. 50 mm dia nominal bore
252Sub Head – XVII Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall. 20 mm nominal outer dia Pipes
253Sub Head – XVII Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall. 25 mm nominal outer dia Pipes
254Sub Head – XVII Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall. 32 mm nominal outer dia Pipes
255Sub Head – XVII Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall. 40 mm nominal outer dia Pipes
256Sub Head – XVII Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall. 50 mm nominal outer dia Pipes
257Sub Head – XVII Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall. 65 mm nominal outer dia Pipes
258Sub Head – XVII Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall. 80 mm nominal outer dia Pipes
259Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
260Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
261Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes
262Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes
263Providing and fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Works 20 mm nominal outer dia pipe
264Providing and fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Works 25 mm nominal outer dia pipe
265Providing and fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Works 50 mm nominal outer dia pipe
266Providing and fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Works 75mm nominal outer dia pipe
267Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm dia. nominal bore
268Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm dia. nominal bore
269Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm dia. nominal bore
270Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm dia. nominal bore
271Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm dia. nominal bore
272Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm dia. nominal bore
273Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm dia. nominal bore
274Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
275Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20 mm nominal bore
276Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm Length, 15 mm nominal bore
277Constructing masonry Chamber 30x30x50 cm inside, in brick working cement mortar 1:4 (1 cement :4 coarse sand)for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 dine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
278Constructing masonry Chamber 60x60x75 cm inside, in brick working cement mortar 1:4 (1 cement : 4 coarse sand)for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 dine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
279Supply & installation of sintex SMC Panel Tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes with fittings and without base support for tank.
280Providing and fixing 2way bib cock with wall flange of Jaquar C P florentine range Cat No.on- LYR - 38041 or equivalent approved make ,including cutting and making good the walls wherever required all complete as directed by the Engineer-in-Charge.Charge.
281Providing and fixing 8 mm dia C.P/S.S Jet with flexible tube upto 1.0M long S.S tringular plate to European type of approved quality & make as per the direction of engineer-in-incharge.
282Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. 15 mm nominal bore
283Providing and fixing C.P. brass long nose bib cock of approved quality condorming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
284Providing and fixing C.P. brass long body bib cock of approved quality condorming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
285Providing and fixing C.P. brass stop cock ( concealed) of standard design and of approved quality condorming to IS:8931 15mm nominal bore
286Providing and fixing toilet paper holder : C.P. brass
287Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality condorming to IS:8931 15mm nominal bore
288Supply Installation Testing Commissioning of water Cooler with all required accessories to complete the job including appropriate Prefilter with its housing and Pipe at the inlet of water cooler appropriate Level Sensor for Water Cooler for switching UV Lamp as direction of Engineering in charge.The details as below: Minimum Storage Capacity 80L, Minimum Cooling Capacity 150L/Hr,No of faucets 01+01 nos ( 1 Normal,1 Cool),Front Tray drain pipe system, Hermetically sealed reciprocating compressor having R-134 a refrigerant,Cabinet Material Stainless steel AUG J1 grade,Stainless Steel Water Tank with float type sensor, Warranty on Cooler and other parts: Minimum 1 years,Supply Volatge-230 V AC,Make of the water Cooler- Voltas/ Blue Star/ Aquaguard / Usha After installation the agency should submit the test report of functioning of all its parts like Float Sensor,Cooling etc. The Unit and its accessories should be leackage free during the warranty period,any leackages found during warranty period agency should attend it on their own cost.
289Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098 ( Part - 2 ) 3013 for soil / waste pipe under ground drainage system with jointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, etc complete. 150 mm diameter
290Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098 ( Part - 2 ) 3013 for soil / waste pipe under ground drainage system with jointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, etc complete. 200 mm diameter
291Providing, laying and jointing in true line and level 110 diametre U.P.V.C (TypeB) conforming to IS13592-1992 with one end plain and othe rend socketed with rubberring, & fittings conforming to ISI14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x149mm length x145mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc.including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
292Providing, laying and jointing in true line and level 75 diametre U.P.V.C (TypeB) conforming to IS13592-1992 with one end plain and othe rend socketed with rubberring, & fittings conforming to ISI14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 75 mm diametre x149mm length x145mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc.including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
293Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standarddesign : 180x150 mm size P type With common burnt clay . (non modular) bricks of class designation 7.5
294Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
295Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
296Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay (non modular) bricks of class designation 7.5
297Extra for depthfor manholes Size 90x80 cm With common burnt clay (non modular) bricks of class designation 7.5
298Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
299Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91m to 1.67m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
300Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
301Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
302Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil. 300 mm dia
303Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for all depths, as perdirection of Engineer -in-charge. 200 mm nominal size dia
304Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia
305Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
306Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
307Supplying, filling, spreading & leveling coarse sand of sizerange 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
308Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
309Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
310Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
311Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
312Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
313Designing, Providing & Fixing, sketching, modeling & fabricating a three dimensional artistic/ murals approx. 10ft x 6.5ft each handmade in well burnt Ceramic/Fibre with fine clay/fibre . The art ceramic/Fibre murals are a set of handmade and hand painted tiles suitable for outdoor and indoor areas according to the requirement. Each tile that forms the amazing ceramic/fibre mural is manufactured with a meticulous artisan process with the latest techniques. The special clay (mud)/fibre used should not be of Chinese quality, reason being the colour is not able to stay on it’s surface firmly. It get’s spread over in an uneven way. If in case the tile breaks or there’s a crack in between, we make a new one immediately . Artist will then make the drawing or design on it and then it’s formed into a proper shape with the help of a tool . Now once all this is ready then the tiles are coloured according to the design and requirement .And colour should be of the best quality so as get best results. The colour is not uneven anywhere.The tiles are fixed firmly with a special type chemical mixture. The rate is inclusive of all T&P, Scaffolding, leads & heights operations.Hardware items and Footing Arrangement with plinth top Granite Finishing required in proper fixing of the mural as per direction of Engineer-in-charge
314Design, Supply & Fixing Marble stone sculptures with Size 6ft x 3.5ft x 2ft . Providing & making individual pieces using laser cutting machine desired shape and profile. All components of origami figure to be developed in 3d model hollow from inside, thenlaser cut with proper dimensions and edges. Smoothening by using machine and tools to get edge finish. using necessary tools and machinery to get even and mirror like finishing in all respects. Designing, making and approval of shop drawings of the entire ser good to be fabricated and assembled at site. Providing and finishing the sculptural Marble stones with mirror finish and balanced flat surface to be kept at the site..Hardware items and Footing Arrangement with plinth top Granite Finishing required in proper fixing of the mural as per direction of Engineer-in-charge
315Design, Supply & Fixing Marble stone sculptures with 6ft x 3.5ft x 3ft . Providing & making individual pieces using laser cutting machine desired shape and profile. All components of origami figure to be developed in 3d model hollow from inside, thenlaser cut with proper dimensions and edges. Smoothening by using machine and tools to get edge finish. using necessary tools and machinery to get even and mirror like finishing in all respects. Designing, making and approval of shop drawings of the entire ser good to be fabricated and assembled at site. Providing and finishing the sculptural Marble stones with mirror finish and balanced flat surface to be kept at the site..Hardware items and Footing Arrangement with plinth top Granite Finishing required in proper fixing of the mural as per direction of Engineer-in-charge
316Design, Supply, Installation, of In S.S. wire {Portrait} of Size 6.5ft x 4ft x 2ft sculpture All components of origami figure to be developed in 3d model. The pieces then needs to bent according to the design and detail.. The faceted sculpture done in SS WIRE shall have a complete empty cavity with no framework . Human Sculpture shall be fitted with two LED focus lights of 6W with the provision of replacement through removable plates with concealed screws. Sculpture shall be finished in The Sculpture is made as outdoor grade.Designing, making and approval of shop drawings of the entire ser good to be fabricated and assembled at site..Hardware items and Footing Arrangement with plinth top Granite Finishing required in proper fixing of the mural as per direction of Engineer-in-charge
317Design, Supply, Installation, of Metal figure sculpture In Bronze {Wonder}. TIn Bronze {Wonder} is in origami process, size 8ft x 1.5ft x 4ft. All components of origami figure to be developed in 3d model The pieces then needs to bent according to the design and detail. The faceted sculpture done In Bronze {Wonder} shall have a complete empty / Fill cavity/Filler with no framework . In Bronze {Wonder} shall be fitted with two LED focus lights of 6W with the provision of replacement through removable plates with concealed screws. Sculpture In Bronze {Wonder} shall be finished with weather protection. Bronze {Wonder} is made as outdoor grade.Designing, making and approval of shop drawings of the entire ser good to be fabricated and assembled at site.Hardware items and Footing Arrangement with plinth top Granite Finishing required in proper fixing of the mural as per direction of Engineer-in-charge
318Providing and fixing Glass reinforced concrete (GRC) screens synthetic rubber /FRP moulded in size, pattern, design, thickness and colour of approved quality/make. The screens made of 53 grade white cement, quartz, fine silica sand, alkali resistant glass fibre, super plasticiser, polymers and UV resistant synthetic inorganic pigments etc including dry fixing with cramps , frame work dash fasteners etc complete.
319Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy duty PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
320Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy duty PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
321Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy duty PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
322Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy duty PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
323Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
324Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
325Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
326Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
327Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
328Supplying & fixing Two Module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
329Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
330Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
331Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
332Supplying and drawing co axial Tv Cable RG-6 grade, 0.7mm solid copper conductor PE Insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surafec /recessed steel/ PVC conduit as required.
333Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antena socket outlet
334Fabrication, supply, installation, testing and commissioning of wall/ floor mounted cubicle panels LT panel, suitable for 415 Volt, 3 phase- 4 wire, 50 Hz. AC supply system made out of 2 mm thick CRCA sheet steel for frame works & covers, 3 mm thick for gland plates, including cleaning & finishing complete with 7 tank process for powder coating in approved shade, all incomngs/ outgoings shall be arranged in suitable size compartments, locking arrangement for each compartments, including interconnection with 1100 V grade PVC insulated aluminium alloy conductor bus bar, control copper wiring, labelling, earthing, brass compression glands for incoming and outgoing cables, powder coated painting etc. as required. All Incomer of distribution board shall be provided with surge protection devices, danger plates. Bottom base channel of MS section not less than 75mm X 50mm X5mm thick. Entire panel shall have a common copper earth bar of size 25mmX5mm at the rear with 2 no. earth studs.Note : The type of the MCCB upto 250 Amp should be Thermal Magnetic type (O/C,S/C) Protection & Rom and above 250 Amp it should be Microprocessor Type (O/C,S/C,E/F) Protection, ST,Ready to close Indication, ZSI in all panels mentioned below. Digital Multifunction Meter With RS-485 CL-0.5S in all below mentioned panels MDB - EV Charging PanelIncoming:315 A, FP MCCB 36 KA - 1 No.400 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 SetOutgoings:63 A DP MCB, - 21 Nos.Instruments: Multi Function Meter (MFM) -1 No. Indication lamp RYB with 2A SP MCB etc as req.
335Meter Board Panel - Ground Floor ShopsIncoming:125 A, 4P MCCB -1 No.200 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 SetProvision for Meter cubicals for Three phase KWH Meter -10 Nos.Outgoings:63 A DP MCB, - 10 Nos.Instruments: Multi Function Meter (MFM) -1 No. Indication lamp RYB with selector switch etc as req.-1No.
336UPS PanelIncoming:400 A, TPN MCCB 36 KA - 1 No.200 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 SetOutgoings:400 A, TPN MCCB 36 KA - 1 No.100 A TPN MCCB, 25 KA - 1 Nos.63 A TPN MCCB, 25 KA - 1 Nos.Instruments: Indication lamp RYB with selector switch etc as req.-1No.
337FDB Power PanelIncoming:160 A, TPN MCCB 25 KA - 1 No.200 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 SetOutgoings:63 A FP MCB, 10 KA - 5 Nos.Instruments: Multi Function Meter (MFM) -1 No. Indication lamp RYB with selector switch etc as req.-1No.
338FDB Power Panel - B1Incoming:125 A, TPN MCCB 36 KA - 1 No.200 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 SetOutgoings:63 A FP MCB, 10 KA - 4 Nos.Instruments: Multi Function Meter (MFM) -1 No. Indication lamp RYB with selector switch etc as req.-1No.
339Lift Panel (For 4 no. of lifts)Incoming :200A, FP MCCB (36 KA) - 1 No.Bus Bar:-1 Set of 300 Amps. TPN busbars of aluminium alloy with colour coded heat PVC shrinkable sleeves.Outgoing: 63 A TPN MCCB - 25 KA - 6 Nos.32A DP MCB - 2 Nos.metering and Indications:The incomer MCCB shall be provided with the following:Three (3) Nos. LED type Phase indicating lamps with protection 2A SP MCBs.- 3 set
340Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100/63 Amp, 36 KA, FP MCCB
341Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 Amp, 36 KA, FP MCCB
342Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 Amp, 36 KA, FP MCCB
343Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 315 Amp, 35 KA, FP MCCB
344Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 Amp, 35 KA, FP MCCB
345Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 630 Amp, 50 KA, FP MCCB
346Supplying and fixing of following ways surface / recess mounting, Vertical Type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, base for mounting MCCBs (but without MCBs and incomer MCCB) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required). 4 way (4 + 12), Double door
347Supplying and fixing of following ways surface / recess mounting, Vertical Type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, base for mounting MCCBs (but without MCBs and incomer MCCB) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required). 6-8 way (4 + 24), Double door
348Supplying and fixing of following way Horizontal Type three pole & Neutral sheet steel, MCB distribution board 415 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, interconnections powder painted including earthing etc.as required. (but without MCB / RCCB / isolator) 6 way (4+ 18), Double door
349Supplying and fixing of following way Horizontal Type three pole & Neutral sheet steel, MCB distribution board 415 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, interconnections powder painted including earthing etc.as required. (but without MCB / RCCB / isolator) 8 way (4+ 24), Double door
350Supplying and fixing of following way Horizontal Type three pole & Neutral sheet steel, MCB distribution board 415 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, interconnections powder painted including earthing etc.as required. (but without MCB / RCCB / isolator) 12 way (4 + 36), Double door
351Supplying and fixing following way Single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB / Isolator) 6 way Double door
352Supplying and fixing following way Single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB / Isolator) 8 way Double door
353Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, MCB suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
354Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, MCB suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
355Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as req. 32/40 amps
356Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as req. 63 amps
357Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
358Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
359Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
360Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB
361Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
362Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
363Supplying and fixing TP sheet steel enclosure on surface/ recess along with following Amp 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. 32/40 amps
364Supplying and fixing TP sheet steel enclosure on surface/ recess along with following Amp 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. 63 amps
365Providing and fixing M.V. danger plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with insciption in single red colour on front side as required.
366Supplying of following sizes and core PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. Complying IS-7098. 4 x 25 sq mm XLPE Aluminium Cable
367Supplying of following sizes and core PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. Complying IS-7098. 3.5 x 50 sq mm XLPE Aluminium Cable
368Supplying of following sizes and core PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. Complying IS-7098. 3.5 Core, 95 sq.mm. XLPE Aluminium Cable
369Supplying of following sizes and core PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. Complying IS-7098. 3.5 Core, 185 sq.mm. XLPE Aluminium Cable
370Supplying of following sizes and core PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. Complying IS-7098. 3.5 Core, 400 sq.mm. XLPE Aluminium Cable
371Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. upto 35 sq. mm (clamped with 1mm thick saddle)
372Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
373Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
374Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
375Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 25 sq mm (28 mm)
376Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 50 sq mm
377Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)
378Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm)
379Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 400 sq. mm (82mm)
380Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket,steel fasteners, connecting to earthing system etc. as required. 315 A, 25 KA, SC for 1 sec
381Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket,steel fasteners, connecting to earthing system etc. as required. 400 A, 30 KA, SC for 1 sec
382Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket,steel fasteners, connecting to earthing system etc. as required. 630 A, 50 KA, SC for 1 sec
383Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 315 A, 25 KA, SC for 1 sec
384Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 400 A, 30 KA, SC for 1 sec
385Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 630 A, 50 KA, SC for 1 sec
386Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required. 125 amps 15 KA SC for 1 sec
387Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required. 200 amps 25 KA SC for 1 sec
388Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
389Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
390Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
391Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
392Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
393Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
394Providing and fixing 25 mm X 5 mm copper. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
395Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
396Providing & fixing 6 SWG dia G.I. Wire on surface or recess for loop earthing as required.
397Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc. complete as required.
398Providing & fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
399Providing & fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
400Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
401Providing and fixing testing joint, made of 20 mm X 3 mm thick GI strip, 125 mm long, with 4 nos. of tinned GI bolts, nuts, chuck nuts and spring washers etc. complete as required.
402Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
403Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.
404LED Down lighter (SMD Type) (System lumen efficacy >135 lm/ Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade , internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C). Powder coated die cast / Extruded aluminum Body including trim. 5 - 7 watt
405LED Down lighter (SMD Type) (System lumen efficacy >135 lm/ Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade , internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C). Powder coated die cast / Extruded aluminum Body including trim. 12 -15 watt
406LED Batten light (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20 mm) 18- 22 watt
407LED Batten light (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20 mm) 40 watt
408LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120 deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 watt
409LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connection with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 36 watt
410Supply, Installation, Testing and Commissioning of LED based 2ft. Surface Mounted Luminaire with a nominal system lumen output of 1150 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 25000 burning hours @L70B50. The luminaire shall have a IP20 Rating with PF>0.9 and THD<10% an operating Voltage Range of 140 - 270 V. THe luminare housing should be made of aluminium Extrusion with Polycarbonate Diffuser. The total power consumption should not exceed 10 W (including driver).
411Supply, Installation, Testing and Commissioning of LED Bulkhead with Wattage including driver <= 10-12 W, System Lumen >= 750 ,Fixture efficacy at System level (Not Chip Level) >100lumens/ watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT Range 5700-6500 K, CRI >80, PF >0.9, THD <10%. Life of fixture 50000hrs@L70% Lumen maintenance, The luminaire shall meet IP65 rating and IK 08 rating . The luminaire housing should made of High pressure die cast Aluminium/ UV stabilized polycarbonate with polycarbonate front diffuser.
412Supply, Installation, Testing and Commissioning of 5-6 W LED Exit & matter at per site requirement Light with inbuilt battery backup of 2 hours, including drivers, fixing accessories complete as required. The fixture should have sufficient intensity and all fixing arrangement complete as required at site. Similar to Bajaj : BESL 03 LED DSD WBB Red/Green or equivalent of Decon and Insatpower
413Supplying & erecting of LED type 80W High bay fixture having power consumption (input voltage 110 - 290 V AC with full efficiency, power factor > 0.9 with 50/60 Hz, CCVC LED driver used for maximum power saving. Best quality Aluminium alloy housing and aluminium Dome for better heat dissipation, CCT Cool white ( 6000 K), CRI 80, Beam angle > 120 degrees, working temperature -20 deg. C to +55 deg.C Body IP 65.
414Supplying Installation, Testing and Commissioning of Dali dimmable suspended Hexagonal shaped Slim 50mm width standalone LED Channel with. Fixture to be made of extrusion Aluminum housing in white finish with high efficiency Prismatic diffuser. LED Used shall be SMD type with Minimum system Lumens 6600lm @66W & efficacy 100lm/W,Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 4000K/6500K (SDCM<=5), CRI Ra >=80, PF >0.95, an Operating working temp range - 0°C < Ta < 45°C & operating Voltage Range of 140-270 V AC. Minimum Internal Surge Protection 4.0KV. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. The Fixture shall be complete with all types of hanging, installation etc. accessories as required. Similar to Philips-SP780P LED66S-6500 PSU W5 OD WH HX CONN from Approved Makes. Model shall be got approved from Architect.
415Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/ Min (Minimum)
416Supplying of Exhaust fans suitable for 230 Volt, 50 Hz, Single phase, A.C. supply and complete with all standard accessories required. 200-225 mm dia.
417Supplying of Exhaust fans suitable for 230 Volt, 50 Hz, Single phase, A.C. supply and complete with all standard accessories required. 450 mm dia.- Heavy duty metalic
418Supplying, installation, testing and commissioning of Microwave technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.6 mtr and for 5m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
419Supplying & erecting approved make wall bracket fan A.C. 230 V, 50 cy/s 400/450 mm sweep wall mounted with height adjustment and rotary tilting device complete with guard, flexible core plug top complete erected with lead wires as directed.
420\\"Online UPS- Input supply: Three Phase, Output supply: Three PhaseSupplying, installation, Testing & Commissioning of of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of moduels requird for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc.\\" UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design,manufacturing and inspection process should confirm to the relevant International standards such as IEC/EN /VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC (inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads.UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/ RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accoseries are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED ) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current.d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc.200KVA (Each Power module shall be < 50 KVA)
421SUB HEAD - VI - PASSIVE CABLING, ACTIVE LAN & IP-PBX SYSTEMNote: Wiring shall include numbering, Ferruling, termination and testing of cables at both ends. Fiber Splicing, Testing with OTDR etc. shall be the part of installation of the fibers.Test Reports of Passive Items with dully authorized by OEM shall be submitted for 25 years warranttee.All Active devices shall have minimum 5 years of support from the date of handover.Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm
422SUB HEAD - VI - PASSIVE CABLING, ACTIVE LAN & IP-PBX SYSTEMNote: Wiring shall include numbering, Ferruling, termination and testing of cables at both ends. Fiber Splicing, Testing with OTDR etc. shall be the part of installation of the fibers.Test Reports of Passive Items with dully authorized by OEM shall be submitted for 25 years warranttee.All Active devices shall have minimum 5 years of support from the date of handover.Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.32 mm
423Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75mm)
424Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable
425Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 2 Run of cable
426Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
427Supplying and fixing of 15U size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
428Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm Powder Coated CRCASheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD)Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
429Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
430Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Copper Patch Cords of length 1m (3ft)
431Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Copper Patch Cords of length 3m (10ft)
432Supply, Installation, Testing & Commissioning of Staggred 24 Port Unshielded, Loaded with Category 6A RJ45 Unshielded Modular Jack, Keystone information outlet (I/O) in accordance with ANSI/TIA 568.2-D, IEC 60603-7-4 2nd Edition, ISO/IEC 11801, ROHS Compliant. The I/O should have minimum 750 mating cycle and 200 insertion cycle and ETL 04-Connector Channel Verified, 1U height, Black with integrated cable support bar, clear label marks and earthing plug for UTP cable termination at rack end complete etc as required.
433Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cut- off wavelength < 1260 nm i/c splicing & marking etc complete as required Single Mode 6 Core Optical fiber cable
434Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. 12 Port LIU
435Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. 24 Port LIU
436Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required.
437Supplying, installation, Testing and commissioning of 10 Giga Bandwidth Data Centre Network Switch of 48 port Layer 3 having features and specifications etc. as mentioned here under: - ToR/EOR/Core Network Switch 48x 10GbE SFP+, 6x 100GbE QSFP28, RPS, with Console Port, Management Port and 1 x USB 2.0 Type A port, The switch must provide a switching capacity of no less than 2.16 Tbps and a forwarding rate of at least 1600 Mpps, ensuring non-blocking performance for high-bandwidth applications. It should support hot-swappable dual power supply modules (AC or DC) for 1+1 redundancy and load sharing, as well as hot-swappable, front-to-back airflow fan trays with N+1 redundancy to ensure continuous availability. IEEE 802.1X support for port-based and MAC-based authentication should be available, along with integration for RADIUS and TACACS+ authentication services. Guest VLANs, DoS prevention, and management access restrictions are essential. SNMP v1/v2c/v3, syslog, sFlow, and support for auto- configuration via DHCP. Support for OpenFlow v1.4, Netconf/YANG, and LLDP is required for modern network automation. Support ONIE (Open Network Install Environment), IEEE 802.1Q bb Priority-based Flow Control (PFC), OpenFlow v1.4, ERPS, IPv6 Tunneling, IP interfaces and supported, VXLAN, Private VLAN, Multicast VLAN, Guest VLAN Double VLAN (Q-in-Q), RoCEv2, PIM-SSM/SM, MSDP. Support High Availability with MLAG/VSS and Layer 2/3 VPNs Critical for Multi-tenant, Virtualized, and Containerized Environments. BGPv4/v6, OSPFv2/v3, IS-IS, RIPng. VRRP, ECMP, BFD, and route redistribution for high-availability routing. Support flexible routing domains and secure inter-segment traffic flow. Certifications: CE, FCC, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
438Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min.
439Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS complete as required. 10 G SFP + Single Mode/Multi Mode
440Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client ., Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication,Government of India etc. complete as required.
441Supplying, Installation, Testing and commissioning of indoor Wireless Controller having features and specifications etc. as mentioned here under- The network controller shall be a dedicated hardware appliance designed for centralized management of wireless access points, It must support the management of up to 500 networking devices, The system should be on-premise, ensuring data privacy and complete control over network configurations. It must include an intuitive user interface for real-time monitoring, device discovery, firmware upgrades, scheduling, and mass configuration deployment. Features such as role-based administration, multi-site management. AP to controller communication shall be use of industry standards-based (IEEE or IETF) CAPWAP or any tunneling protocols as per guidelines of DoT.The controller should support Layer 2 and Layer 3 device discovery, VLAN configuration, MAC ACL groups, IGMP snooping, and bandwidth optimization. Automatic radio frequency (RF) management and access policy enforcement are required for reliable wireless performance. The solution must offer a comprehensive dashboard with network topology, floor plan views, client and device lists, and alert notifications. For authentication, it should support a range of methods including local database, external RADIUS, LDAP, and passcode or MAC-based access.It should provide detailed traffic analytics, logs, and customizable reporting for network visibility and planning. Firmware and configuration backup and restoration functions must be available, with USB- based log storage supported. Physical specifications should include a compact form factor with a minimum of one 2.5G Ethernet port and USB 3.0 port, and it must be MTCTE,CE, FCC, and RoHS certified. The controller should operate reliably within a 0°C to 40°C temperature range and 10–90% non-condensing humidity. /Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
442Supply, Installation, Testing and Commissioning of IMS Server media Gateway IP-based Voice solution with 2x PRI Trunk lines (30 Ch) Circuit with CLIP Facility, 800 IP users License, 04 CO Trunks with FSK support, 08 Digital, 32 analog, 4 GSM ports, 01 Nos. IP Operator Console with 40 hard DSS keys, MGW with redudnat cpu & psu (AC & DC Both), 120 Party Conference, Speed Dial, Music on Hold, Internal/External ring difference, Call Barring, Call Pickup, and TEC GR should be with Type I, II, and III Approval, complete as required.Approved Makes: Cisco / Coral / Teleshure / Alcatel / Mitel
443Supply, Installation, Testing & Commissioning of Type-1 IP Phone with 1 SIP accounts, 2.3 inch 132*64 Graphical LCD with Backlight display, Dial Plan, XMLBrowser, Hot Desking, Keypad Lock, Action URL/URI, PoE etc as required.Approved Makes: Cisco / Coral / Teleshure / Alcatel / Mitel
444Supply, Installation, Testing & Commissioning of Type-2 IP Phone with 2 SIP accounts, HD Voice, HD Speaker, 4.3 inch 480*272 Pixel Colour display with backlight 16-bit depth colour, 10 Line Keys with LED, 2 x 1Gig Ethernet Ports, Dial Plan, XMLBrowser, Hot Desking, Keypad Lock, Action URL/URI, PoE etc as required.Approved Makes: Cisco / Coral / Teleshure / Alcatel / Mitel
445Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
446Supplying, installation, testing & commissioning of repeater panel with 320 character / touch screen LCD display with inbuilt reset, acknowledge and silent switches complete as required.
447Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermister complete with base as required.
448Supplying, installation, testing & commissioning of addressable fire control module complete as required.
449Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
450Supplying, installation, testing & commissioning of addressable manual call point complete as required.
451Supplying, installation, testing & commissioning of fault isolator complete with base as required.
452Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
453Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
454Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
455Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to print out log and facility to have seamless integration with analog / digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Ten Loop Panel
456Supplying and fixing of 25mm dia size of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
457Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC as required. 2 x 1.5 sq. mm
458Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
459Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
460Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
461Supply, installation, testing & commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection complete as required.
462Supplying and fixing of 25mm dia size of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
463Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm
464SUB HEAD - VIII- CCTV SYSTEMNote:1. All CCTV items shall be NDAA complaint for cyber security.2. Proper tagging of good quality should be done for all items.3. The Camera OEM should not be black listed in any Govt/PSU/Semi-Govt etc. from last 5 years.4. Video Management Software, All Cameras, NVR & software shall be of same make Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :-1) Type of Camera: Dome Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8)Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night.9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming, configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser15) Profile Management: User configuration import, export16) Security: User Authentication, Water Marking17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics : Tripwire, Intrusion, Motion Detection20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection21) Alarm Support: It should have 1/1 Alarm In/ Out Port22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast,24) System Capability: ONVIF25) VMS: Camera shall support open source VMS26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.27) Ethernet: 1 RJ 45 10/100 Ethernet port28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE30) Enclosure: IP67 weather proof, IK1031) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens Dome Camera.
465Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc :-1) Type of Camera: Bullet Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Lens Type & Focus: as given below.9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 Mtrs for colour view in night.10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72311) Wide Dynamic Range: WDR (120dB or more)12) Digital Noise Reduction: DNR (2D/3D) On/Off13) Streaming: Triple streaming, configurable14) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5MP/6MP @25/30 fps, Sub streams: D1@25/30 fps or better15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser16) Profile Management: User configuration import, export17) Security: User Authentication, Digital Water Marking18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.19) Recording Management: Format SD, overwrite, storage management, video to NAS device,20 Edge Analytics: Tripwire, Intrusion, Motion Detection21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection22) Alarm Support: It should have 1/1 Alarm In/ Out Port23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/ AAC/ G.726 audio compreesion24 Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast,25) System Capability: ONVIF26) VMS: Camera shall support open source VMS27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, , video encryption, IP/MAC filtering, HTTPS, trusted upgrade.28) Ethernet: 1 RJ 45 10/100 Ethernet port29) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.30)Power Requirement: 12VDC/24V DC/PoE (802.3af)/ePoE31) Enclosure: IP67 weather proof, IK1032) Operating Condition: Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)33) IR life: 40000 hours or higher34) Video Bit rate: 32 KBPS - 8 MBPS or better35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera.
466Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :-PTZ (Pan,Tilt and Zoom)IP IR Camera having following spcifications and features etc :-1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS3) Signal System: PAL/NTSC4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,, 0 lux with IR, or better5) Imaging: 1/1s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Event Notification: Through Relays, E-Mails or FTP9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance. The camera should have IR LED’s and cover distance up to 300 meter or above10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it.11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering.12) Presets: 300 Presets13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72314) Wide Dynamic Range: WDR (120dB or more), HLC & BLC15) Digital Noise Reduction: DNR (2D+3D) On/Off16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser17) Profile Management: User configuration import, export18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be supplied with minimum 128GB Memory.20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, Face Detection22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS.23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).24) VMS: Camera shall support open source VMS25) Connectivity: 1x LAN RJ-45 (10/100Base-T)26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.127) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at)30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection31) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 5MP IP IR motorized PTZ @25/30fps or better camera, Triple streaming , configurable on resolution:- Main stream: 5MP@25/30 fps Sub streams: 1080p @25/30 fps, varifocal lens 3.95mm (±5mm) ~ 177.75mm (±5mm) or better with Automatic & manual Focus Adjustment provisions, 45x Optical zoom and 16x Digital zoom with angle of view H: 65.7°–1.9°V: 39.4°–1.1°D: 73.1°–2.1, PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s
467Supply, Installation, Testing & Commissioning of Video Management Software supporting ONVIF Profile S & G (Listed on ONVIF website), PSIA, Real time streaming protocol (RTSP) standards, emerging technologies in the industry, like 4K resolution, H.265 video compression codec, 3D PTZ control, 360° Fisheye camera and multi-imager/lens camera support. Software proposed should be SQL based with at least 500 camera and 05 clients included to view/record all the cameras, licenses should expandable up to 1000 cameras & 10 clients without any additional version upgrade. N+1 redundancy should be supported with proposed VMS. Vendor to consider and quote all necessary additional software, Licenses and accessories required to make the system functional. Video Management Software shall support - 1) Perpetual software licence; must not be renewed periodically. 2) 2000 cameras management on single server instance. 3) N:1 and N:M recorder redundancy; application should also be able define priorities among the redundant servers 4) Digital Signature and password protection on exported clips 5) Calendar Search with thumbnail image preview of recording and quick export of video clips 6) Smart Motion Detection/Search on recorded video for multiple regions of interest7) Tracking object from selected set of interlinked surrounding cameras with smart algorithm (with min. 12 cameras)8) Export recording by creating a package of clips of multiple cameras at different times that can be played sequentially9) Centralized Device Maintenance: Tool to perform bulk camera firmware and password updates. Software OEM should have toll free number for technical or service support.Approved Makes: Honeywell/ Bosch/Pelco/Axis
468Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth.2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10.6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE,FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm24) It should have Web and GUI interface.25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image.27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics34) Analytics by NVR: Perimeter protection and face recognation64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16
469Supply, installation, testing and commissioning of VMS Server Hardware as per following specifications: Intel® Xeon® E-2236 3.4 GHz, Chipset: Intel® C246, Microsoft Windows® Server 2019 64-bit, Microsoft SQL 2017 (Express or standard edition to be considered as per site requirement), System Memory (RAM): 16GB DDR4, Hard Disk Drives: Dual (RAID1) 480GB SSDs for OS; Network Interface Card (NIC): 2 x Gigabit Ethernet ports, 2 USB 3.0 ports, Human Interface: 102-key keyboard and a mouse pointing device, Display Adapter: Matrox G200 or equivalent, Monitor Output: 1 x VGA, Windows Media Player Version 12, Dual Hot-plug Redundant Platinum power supplies, Certifications: UL, CE/EN, FCC along with UPS power, associated cables etc complete as required.
470Supply, installation, testing & commissioning of Client Workstation as per following specifications:Intel Core i7-8700K or better, 4.2GHz, OS - Genuine Microsoft Microsoft® Windows 10 Enterprise/IOT 64 Bit, RAM - 16GB, OS - 480 GB SSD/SATA, Graphic Card - In-built Processor Graphics (GPU):Intel® HD Graphics 630 or Intel Q470 Processor, supporting 2 Monitors, 01 LAN 01GBPS, Audio IN & Out, USB3.0, Keyboard and Mouse, associated cables etc complete. Approved Makes : Lenovo/ Dell / HP
471Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications 10TB (Terabytes)
472Supply, Installation, Testing and Commissioning of Full HD smart 55\\" LED Professional Display Panel for 24*7 operation complete as per tender specification as required. Approved Makes: Panasonic / LG/ Samsung/Allsee
473Supply, Installation, Testing and Commissioning of 15 Mtr. HDMI Cable as required at site for CCTV operation. Approved Makes: Aten / Kramer / Extron / BlueRigger
474Sub Head-IX-LIFTS Supplying, installation, testing & commissioning of 16 Passenger / Stretcher gearless lift with Machine Room having contract speed of 1.5 MPS in the existing lift shaft as per detailed specifications enclosed and as under (i) Speed : 1.5 MPS(ii) Floors : 14 (2B+G+11)(iii) Travel : 58 mtrs (approx.) (iv) Stops & opening : 14 /14(v) Controller: A.C. variable voltage & variable frequency(vi) Operation : Microprocessor based simplex selective collective with / without atten­dant(vii) Power - 415 V, 3 phase, 50 Hz, 4 wires system(viii) Type of doors(a) Car Doors: AuAutomaticPower operated, center opening horizontal sliding stainless steel scratch proof finish. (b) Landing Doors: AutomaticPower operated, center opening hori­zontal sliding stainless steel scratch proof finish. Landing doors will have fire resistance rating of two hour.(ix) Car body will be of scratch proof SS finish.(x) Emergency light in the lift car.(xi) Full height Infra Red protection is to be provided for landing/ car doors.(xii) Provision of Toe guards, Fireman's switch etc.A Stainless steel hand rail not less than 600 mm long at 900 mm above floor level to be fixed on both the side panels and rear panel in the lift car.Button in car operating panel & landing operating panel shall be having Braille Inscription & shall be fixed for the handicaped.Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.Flooring:-chequered aluminium sheet.Lift installation shall include all safety like ARD with suitable battery backup etc. & control features as specified in the specifications.The features required for use of the lift by handicapped persons eg three side hand rail, braile signage closing speed of doors etc
475SUB HEAD-X - SOLAR POWER GENERATION SYSTEMSupplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/ Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors (MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.f) Lightning, surge voltage protection, earthing protection and grid islanding.g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel /conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.
476Supply, Installation, Testing and Commissioning of BIPV Solar Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium /GI structure of suitable strength with following components complete as required. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% attheend of 10 years and 80% attheend of 25 years. b) Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and 400 VAC, three phase, 4 wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C.
477SUB HEAD-XI - SUBSTATION EQUIPMENTS11 KV HT Panel \\"Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 26.3 KA for 3 Sec (1500 MVA). Internal Arc for AFLR 26.3kA at rated voltage for 1s at individual compartments i.e. Busbar, VCB and cable compartment. complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switch gears and accessories.\\"The panel shall be complete with following switchgear and accessories. All major sub-components (switchgear, relays & vacuum interrupters) shall be of same make. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel.INCOMER PANEL - Each Comprising of1-Metal clad housing with truck having 800 A,1500 MVA, TP integral VCB with manually /electrically operated mechanism (spring charging motor-230 V AC)1 set of air insulated bus bar of 800 A1 set of isolating plug and receptacle1 set of automatic safety shutter1- set of breaker control switch, lockable type Trip /Neutral /Closed (TNC)1 set of dual core CT'sCore l 400/200/5/5 A class 5P-20 (15 VA) protectionCore ll 400/200/5/5 A class 0.5 (15 VA ) metering1- Shunt trip closing coil 24 V DC 1- 11 KV end termination kit for 3x300 sq.mm AI.XLPE 11 KV armoured cable3-No's P.T'S 33/0.11 KV of (100 VA) cast resin type1-set ON/OFF /Trip & Circuit healthy and phase indicating LED lamps. 1- No Micoprocessor based Numerical relay with O/C EF &SC Protection. Relay should have arc flash fault protection in cable, busbar and breaker chamber and shall communicate over IEC61850 protocol to SCADA.1-No UL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy, disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cycle with ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.1-No master trip relay1-12 No's annunciation window with relays and push buttonsOUTGOING PANEL : Each Comprising of :1-Metal clad housing with truck having 800 A ,1500 MVA TP integral VCB manually/ electrically operated mechanism (spring charged motor 230 V A.C.)1- Set of air insulated bus bar1- Set of isolating plug and receptacle1- Set of automatic safety shutters1- Set of breaker control switches (TNC)1-Set of dual core CT'SCore I - 200 /100/ 5 /5 class 5P -10 (15 VA)Core II - 200 / 100/ 5/5 class 1 (15 VA)1- Shunt trip closing coil 24 V DC / 110 V A.C1- 11 KV end termination for 3 x 240 sq.mm AI.XLPE 11 KV cable1-set ON/OFF /Trip & Circuit healthy Indicating LED lamps.1- No Micoprocessor based Numerical relay with O/C EF &SC Protection. Relay should have arc flash protection in cable busbar and breaker chamber and shall communicate over IEC61850 protocol to SCADA.1-No master trip relay1-12 No's annunciation window with relays and push buttons1-No 2 elements auxiliary relay for transformer (WTI with alarm & trip)1-set of terminal block with 20% extra terminal for connection with 2.5sq.mm 4 core copper conductor pvc insulated pvc sheathed copper cable from panel to transformerSITC of 11 KV HT Switchboard of 3 panels, 1 I/C & 2 O/G panels as above and as per specifications shall be with all accessories, interconnections, internal wiring, labels etc. complete as required.
478SITC of RMU type SF6 11 KV HT Panel - Stainless steel tank, (Non Extensible & manual) complete as required.12kV, 630A, 21 KA Fixed type 3 Ring switch. (stainless steel tank)SF6 Gas pressure indicatorCapacitive voltage indication systemFault passage indicatorFront cable Termination arrangement for Load Break switchRight angled insulating boots-setHardware bolts & nutsOperating Handle - Load Break switchLifting Arrangement for ease of HandlingSITC of 11 KV HT SF6 panel at incomer panels as above and shall be with all accessories, interconnections, internal wiring, labels etc. complete as required.
479Supply, installation, testing and commissioning of following capacity (continuous loading) 11/0.433 KV Delta/Star,step down, 3 Phase, 50 Hz, Dyn 11 vector group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better) AN (air natural) cooled transformer suitable for indoor applications with On Load Tap Changer (OLTC) on HV side having AVS relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote/ manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behavior class F1,climate class-C1, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers, bus trunking arrangement on LV side complete with all accessories and safety provisions as per relevant IS Code,The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge Arrestors on HV Side. Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories ,complete in all respects as required at site as per CPWD specifications . Design ambient condition :a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location /site. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard.Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Thermometer pocket with cap; d) Lifting lugs for the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); g) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. for transformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1 600 kVA); j) Name Rating & Diagram Plate. k) Monogram Plate.i) Additional neutral separately brought out on bushing for earthing.Level 51600 KVA (losses at 50% loading < 3970watt, losses at 100% loading < 11300watt)
480HYBRID Power Factor Correction SystemSupply, Installation, testing and commissioning of HYBRID APFC Panel, 3 phase 4 wire, 415 V, 50 Hz AC System for Ambient temperature -5°C to +40°C of following capacity with passive solution of 60% capacity and active solution of 40% capacity, 3Phase 4 wire Hybrid Power Factor Correction Solution (with arrangement for neutral current balance) to achieve >0.99 lag and TDDI/THDV values within IEEE recommended limits.APFC should be designed as per IS 16636 Or IEC 61921. The active section and passive section shall work in sync to give optimized output. The degree of protection of passive section should be IP 42, and of active section should be minimum IP 21.The switching device for APFC passive section should be through capacitor duty contactor and for the active compensation system shall be IGBT based with 3 level topology having 12 IGBT in inverter circuit. The active compensation system should filter harmonics from 2nd to 50th individual harmonic order and shall be selectable for the entire range. The active compensation system should have feature to improve PF correction and harmonic filtration having response time <25Micro second. The hybrid panel shall be indoor type floor mounted free standing totally enclosed, extensible, fabricated in compartmentalized designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in- Charge), having front section (switch gear and control accessories) and rear section (capacitor and reactor), front and rear access, having suitable current carrying capacity, extensible TPN Aluminum alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as per below details.(A) IncomersSuitable capacity MCCB/ACB (Upto 300 KVAR, MCCB and above 300 KVAR, ACB ) Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handel and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.(B) Instruments & Indicationsa)For Passive Section :i) 3-Phase current sensing APFC microprocessor relay/controller , advance 12/16 stages (12 stages for over all capacity of panel (active + passive) below 500 KVAR and 16 stages 500 KVAR & above) and having display of Phase wise V, A, PF, Cos-Phi, KW, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level.ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency.iv) Suitable rating control transformer shall be provided for control and indication circuit.v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's.vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade, PVC insulated multi stranded copper control wire.vii) Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge.b) For Active Section : Dedicated HMI (Human Machine Interface) (Minimum 7 inch display) for controlling and communication and having display of Phase wise V, A, PF, Cos-Phi, KW, KVA, KVAR, THD-V , THD-I, harmonics up to 50th level. Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge.550 KVAR
481Main LT Panel- ESSDesign, manufacture, testing at works, supply, installation, testing and commissioning of MODBUS ready SCADA Compatible 415V LT Panel Tested Assembly – TTA, CPRI /Independent international test house tested for all the tests as per IEC61439-1 & 2 and internal arc tests as per IEC 61641, 50kA for 0.3 SEC. Copies of the test reports & certificates shall be submitted with the tender. LT Panel shall also be tested of design as per Seismic Zone 4 of IEC 60068-3-3 requires compliance against 0.4g acceleration. Panel shall be rated for Impulse withstand capability as per IEC-61439. For operator safety IP2 X (touch proof) protection to be available even after opening the feeder compartment door. The compartmentalization to be achieved by using metal separators, use of PVC sheet / Hylem sheets shall not be allowed. Main LT Panel shall be form 4b, for form of separation and rest with form 3b ,only metallic covers shall be used, Hylem / PVC sheets shall not be allowed. The panel shall be FRONT operated, suitable for bus duct entry for transformer incomings. Outgoing panels shall be suitable for cable entry from the top/bottom. The type tested design of the Switchboard shall be proven design from the main switchgear manufacturer (OEM). All switchboards shall be supplied by authorized system integrator and design, design warranty, including performance warranty on the switch boards shall be from original equipment (switchgear) manufacturers.Note : ALL the Panels should be SCADA Compatible for Monitoring & Control on Ethernet and should include all accessories as required.Each breaker in Main LT Panel & Emergancey panel shall have Zone Selective Interlocking feature.INCOMING FROM TRANSFORMER (1600 KVA)2 No. 2500A, 4-pole EDO type ACB having release with following functions :Protection for O/C, S/C, E/F and Metring for Current- I1,I2,I3,In,Iavg,Imax, Voltage- Vph, Vline,Power- KW, KVA, KVAR, Power factor, Maximeters /minimeters Energy –KWh,KVAh, KWArh, Demand current- Ph & Neutral, Demand power-KWh, Under & over frequency, current unbalance, reverse power, phase seq. reversal, Last 10 faults with date and time stamping, Last 10 alarms with date and time stamping, Current and Voltage Harmonics till 31st multiple with Waveform capture. All release data should be available over MODBUS.TNC breaker control switch.ON, OFF, Trip, Ready to close and RYB indication lights with backup MCBs of 2A.96 x 96 sq.mm display module mounted on panel door directly connected from release to display all parameters of ACB/MCCB.Bus Coupler1 No. 2500A, 4-pole EDO type ACB having microprocessor release with following functions :Protection for O/C, S/C, E/F and Last 10 faults with date and time stamping,Last 10 alarms with date and time stamping, All release data should be available over Modbus.ON, OFF, Trip, Ready to close and RYB indication lights with backup MCBs of 2A.Bus BarSet of 3200 Amps rating TPN copper Bus Bars of suitable length shall be provided for entire length of panel board. Busbar Design suitable for Temperature rise 40 degree over & above ambient temp. of 45 degreesOutgoing Panels\\"All ACB shall have release with following functions :Protection for O/C, S/C, E/F and Metring for RMS values of highest current, Bargraph for % loading, Ammeter, Current- I1,I2,I3, In,Iavg,Imax, Voltage- Vph, Vline, Power- KW,KVA, KVAR, Power factor, Maximeters/minimeters, Energy –KWh, KVAh, KWArh, Demand current- Ph & Neutral, Demand power-KWh. The electrical endurance of ACB shall be 10000 operations upto 1600 AMP ACB and 6000 operation upto 3200 AMP ACB. All release data should be available over MODBUS.All MCCBs shall have Microprocessor release with following inbuilt functions :Protection for O/C, S/C, E/F.\\"Bus Section - A1250 amp, 50KA FP ACB ---------------1 Nos.800 amp, 50KA FP ACB ---------------1 Nos.630 amp, 50KA FP MCCB ---------------2 Nos.400 amp, 50KA FP MCCB ---------------1 Nos.315 amp, 50KA FP MCCB ---------------2 Nos.200 amp, 36KA FP MCCB ---------------1 Nos.Bus Section - B1250 amp, 50KA FP ACB ---------------2 Nos.800 amp, 50KA FP ACB ---------------2 Nos.630 amp, 50KA FP MCCB ---------------1 Nos.400 amp, 50KA FP MCCB ---------------1 Nos.200 amp, 36KA FP MCCB ---------------2 Nos.Metering & Indication for each outgoing feeders.96 x 96 sq.mm display module mounted on panel door directly connected from release to display all parameters of ACB/MCCB.Set of ON/OFF/Trip/Trip Circuit healthy/ready to close (for ACB) lamp with control MCBs of 2A.SITC of Main LT Panel ESS (TTA Type) as per specifications and details above complete as required.-
482EMERGENCY PANEL (DG Sychnronization cum PLC Panel) in ESSDesign, manufacture, testing at works, supply ,installation, testing and commissioning of MODBUS ready SCADA Compatible 415V LT Panel Tested Assembly – TTA, CPRI /Independent international test house tested for all the tests as per IEC61439-1 & 2 and internal arc tests as per IEC 61641, 50kA for 0.3 SEC. Copies of the test reports & certificates shall be submitted with the tender. LT Panel shall also be tested of design as per Seismic Zone 4 of IEC 60068-3-3 requires compliance against 0.4g acceleration. Panel shall be rated for Impulse withstand capability as per IEC-61439. For operator safety IP2 X (touch proof) protection to be available even after opening the feeder compartment door. The compartmentalization to be achieved by using metal separators, use of PVC sheet / Hylem sheets shall not be allowed. Main LT Panel shall be form 4b, for form of separation and rest with form 3b ,only metallic covers shall be used, Hylem / PVC sheets shall not be allowed. The panel shall be FRONT operated, suitable for bus duct entry for transformer incomings. Outgoing panels shall be suitable for cable entry from the top/bottom. The type tested design of the Switchboard shall be proven design from the main switchgear manufacturer (OEM). All switchboards shall be supplied by authorized system integrator and design, design warranty, including performance warranty on the switch boards shall be from original equipment (switchgear) manufacturers. EMERGENCY PANEL (IEC 61439-1&2)INCOMING FROM MAIN LT PANEL1 No.1250A, 4-pole microprocessor based ACB having release with following functions :Protection for O/C, S/C, E/F and Metring for Current- I1,I2,I3,In, Iavg, Imax, Voltage- Vph, Vline, Power- KW, KVA, KVAR, Power factor, Maximeters /minimeters Energy –KWh, KVAh, KWArh, Demand current- Ph & Neutral, Demand power-KWh, Under & over frequency, current unbalance, reverse power, phase seq. reversal, Last 10 faults with date and time stamping,Last 10 alarms with date and time stamping, Current and Voltage Harmonics till 31st multiple with Waveform capture. All release data should be available over MODBUS.TNC breaker control switch.ON, OFF, Trip, Ready to close and RYB indication lights with backup MCBs of 2A.96 x 96 sq.mm display module mounted on panel door directly connected from release to display all parameters of ACB/MCCB.INCOMING FROM DG SETS2 No.630A, 4-pole microprocessor based MCCB having release with following functions :Protection for O/C, S/C, E/F and Metring for Current- I1,I2,I3,In, Iavg, Imax, Voltage- Vph, Vline, Power- KW, KVA, KVAR, Power factor, Maximeters /minimeters Energy –KWh, KVAh, KWArh, Demand current- Ph & Neutral, Demand power-KWh, Under & over frequency, current unbalance, reverse power, phase seq. reversal, Last 10 faults with date and time stamping,Last 10 alarms with date and time stamping, Current and Voltage Harmonics till 31st multiple with Waveform capture. All release data should be available over MODBUS.TNC breaker control switch.ON, OFF, Trip, Ready to close and RYB indication lights with backup MCBs of 2A.96 x 96 sq.mm display module mounted on panel door directly connected from release to display all parameters of ACB/MCCB.Bus BarSet of 1250 Amps rating TPN Copper Bus Bars of suitable length shall be provided for entire length of panel board.Outgoing Panels\\"All ACB shall have release with following functions :Protection for O/C, S/C, E/F and Metring for RMS values of highest current, Bargraph for % loading, Ammeter, Current- I1,I2,I3, In,Iavg, Imax, Voltage- Vph, Vline, Power- KW,KVA,KVAR, Power factor, Maximeters/minimeters, Energy –KWh, KVAh, KWArh, Demand current- Ph & Neutral, Demand power-KWh. The electrical endurance of ACB shall be 10000 operations upto 1600 AMP ACB and 6000 operation upto 3200 AMP ACB. All release data should be available over MODBUS.All MCCBs shall have Microprocessor release with following inbuilt functions :Protection for O/C, S/C, E/F.\\"400 amp, 36KA FP MCCB ---------------4 Nos.315 amp, 36KA FP MCCB ---------------1 Nos.200 amp, 36KA FP MCCB ---------------3 Nos.100 amp, 36KA FP MCCB ---------------2 Nos.63 amp, 36KA FP MCCB ---------------2 Nos.Metering & Indication for each outgoing feeders.96 x 96 sq.mm display module mounted on panel door directly connected from release to display all parameters of ACB/MCCB.Set of ON/OFF/Trip/Trip Circuit healthy/ready to close (for ACB) lamp with control MCBs of 2A.SITC of Emergency Supply Panel as per specifications and details above complete as required.
483SANDWICH BUS DUCTSupply, installation, testing and commissioning on sandwich (Indoor type) bus trunking suitable for 433Volt, 3 Phase 4 wire 50Hz AC supply system of aluminium bus bars complete with bends, expansion joints, fire barriers, copper flexible end connections at both ends, flanges, elbows, fixing clips, angles, earthing with 2 runs of Alu. earth strips of adequate size suitable for fault level rating of 50kA for 1.0 second running throughout the bus duct including necessary supports etc. as per specification and as per IEC 61439 Part- 1&2 as required for following ratings:-2500 Amp TPN Bus duct (Icw =50kA for 1 second)
484(Between LT side of 1600 KVA Transformer and Incoming of Main LT Panel ) 800 Amp TPN Bus duct (Icw =50kA for 1 second)
485(Between AC & LT PANEL ) 1250 Amp TPN Bus duct (Icw =50kA for 1 second)
486(Between Main LT Panel & Capacitor Panel)H.T. / L.T. CABLES, CABLE TERMINATIONS AND CABLE TRAY Supply of following size of 11 KV XLPE insulated aluminium conductor earthed and armoured cable conforming to IS 7098 complete as required.3 Core, 300 sq.mm
487Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
488Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm
489supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300 sq. mm
490Supply of following sizes and core PVC/ XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 vlots. (Conforms to IS:1554, part-1). 3.5 Core, 300 sq.mm. XLPE Aluminium Cable
491Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm & upto 400 sq.mm
492Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
493END TERMINATIONS OF 1.1KV CABLES Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required. 3½ X 300 sq. mm (70mm)
494CABLE TRAY / RCC PIPE Supplying and installing following size of perforated HotDipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width x 50mm depth x 1.6 mm thickness
495CABLE TRAY / RCC PIPE Supplying and installing following size of perforated HotDipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width x 50mm depth x 2.0 mm thickness
496CABLE TRAY / RCC PIPE Supplying and installing following size of perforated HotDipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm width x 50mm depth x 2.0 mm thickness
497Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100mm dia.
498Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 250mm dia.
499Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) For Fiber & Power cables
500Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal) For Fiber & Power cables
501SAFETY EQUIPMENT Supply & erecting of following items for substation. Rubber hand gloves suitable for 11 KV.
502Shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.
503Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
504Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required
505Carbon dioxide fire extinguishers of 4.5 kg each mounted on wall hooks as per IS : 2878-1976 complete with all accessories.
506Dry chemical fire extinguishers 5 kg as per IS: 2171-1976 mounted on wall hooks.C8
507G.I. Fire buckets 13 litre capacity filled with dry sand and fixed on wall on hook made out of 13mm dia MS rod & conforming IS 2546 - 1974.
508First aid box containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross complete as required.
509Rubber mat 914.4 mm wide and 15 mm thick to withstand 11 KV dielectric strength as per IS 5424- 1969.
510Rubber mat 914.4 mm wide and 6 mm thick to withstand 1.1KV dielectric strength.
511Supplying, installation, testing and commissioning of pre-engineered Automatic Clean Agent 3M Novec 1230 (UL Listed/ FM approved) Direct Low Pressure (DLP) System complete With DOT/PESO approved cylinder fitted with Automatic Valve. Complete System shall be Tested and Certified to LPCB/VDS/UL. (Makes : FireTrace / Kidde /Minimax /Siemens) Supply, installation, testing and commissioning of 10LB. Novec-1230 DLP Assembly with automatic valve mounted on DOT/PESO approved cylinder, push in connector for tube, Mounting bracket etc.
512Supplying, installation, testing and commissioning of pre-engineered Automatic Clean Agent 3M Novec 1230 (UL Listed/ FM approved) Direct Low Pressure (DLP) System complete With DOT/PESO approved cylinder fitted with Automatic Valve. Complete System shall be Tested and Certified to LPCB/VDS/UL. (Makes : FireTrace / Kidde /Minimax /Siemens) Supply, installation, testing and commissioning of 5LB. Novec-1230 DLP Assembly with automatic valve mounted on DOT/PESO approved cylinder, push in connector for tube, Mounting bracket etc.
513Supplying, installation, testing and commissioning of pre-engineered Automatic Clean Agent 3M Novec 1230 (UL Listed/ FM approved) Direct Low Pressure (DLP) System complete With DOT/PESO approved cylinder fitted with Automatic Valve. Complete System shall be Tested and Certified to LPCB/VDS/UL. (Makes : FireTrace / Kidde /Minimax /Siemens) Supplying, installation, testing and commissioning of 2.5LB. Novec-1230 DLP Assembly with automatic valve mounted on DOT/PESO approved cylinder, push in connector for tube, Mounting bracket etc.
514Supplying, installation, testing and commissioning of pre-engineered Automatic Clean Agent 3M Novec 1230 (UL Listed/ FM approved) Direct Low Pressure (DLP) System complete With DOT/PESO approved cylinder fitted with Automatic Valve. Complete System shall be Tested and Certified to LPCB/VDS/UL. (Makes : FireTrace / Kidde /Minimax /Siemens) Supply, installation, testing and commissioning of UL listed Linear Pneumatic Heat Detection Tube (operating temp at 120 Degree Centigrade, Colour-Red) For Automatic Fire Detection & Suppression.
515Supply, installation, testing and commissioning of tee connection.
516Supply, installation, testing and commissioning of elbow connection.
517Supply, installation, testing and commissioning of end of line adapter with Pressure Gauge For charging & monitoring.
518Supply, installation, testing and commissioning of Low pressure switch for monitoring system activation.
519Supply, installation, testing and commissioning of Master control Unit with LED Flasher, Electronic Hooter, LED Indicator with provision for Integration with Fire Alarm Control Panel complete as required.
520Earthing For Substation EquipmentsEarthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
521Providing and fixing 25 mm X 5 mm copper. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
522Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
523Supply, Installation, Testing and commissioning of EV charging station As per specifications and in Compliance to relevant IS codes etc. Light EV AC Charger (Mode-3)Power : 7 kW, Input power supply: 1phase 230 +10% Volt, output supply: 230 Volt AC, Frequency:50 Hz +/-3%, Operational temperature range : -25 to 55 degree C (outdoor), -5 to 55 degree C(Indoor)., RH upto 95%, Charging Device as per IS-17017-22-1 EV-EVSE Communication: as per relevant IS Codes, Bluetooth Low Energy, one Charge Point Plug/ Socket as per IS- 60309 and IS-17017-2, Vehicle Inlet/ Connector As per EV manufacturer, suitable for 2 Wheelers and 4 wheelers. Indoor use: at least IP41; Outdoor use: at least IP44. Mechanical Strength :protection of the external enclosure against mechanical impact shall be IK08 according to IEC 62262.O/L,S/C protection. Insulation Resistance > 1 M Ω. Cable Length: 7.5 m. RCD having a rated residual operating current not exceeding 30 mA; Separate RCD for multiple outputs. Telecommunication port of the EV supply equipment according to IS 13252 (Part 1) : 2010. OCPP(Open charge point protocol) 1.6J upgradable to ocpp 2.0. Device Should follow 17017 series of IS codes in general and the installation of the system shall comply with relevent IS Codes.
524Parkbay AC Charger (Mode -3) Power Level 2: Normal Power ~11kW/ 22 kW, 3 phase 415VAC(-40% to +20%), Frequency:50 Hz +/-5%, output supply: 240 Volt AC, Operational temperature range : -25 to 55 degree C (outdoor), -5 to 55 degree C(Indoor), RH up to 95%, Charging Device as per IS-17017-1 EV-EVSE ISO-15118 for Smart Charging, Infrastructure Socket as per IS-17017-2-2, Vehicle Connector as per IS-17017-2-2 Vehicle Inlet/ Connector As per EV manufacturer, suitable for 4 wheelers. Indoor use: at least IP41; Outdoor use: at least IP44. Mechanical Strength : protection of the external enclosure against mechanical impact shall be IK08 according to IEC 62262. O/L,S/C protection. Insulation Resistance > 1 M Ω. Cable Length: 7.5 . RCD having a rated residual operating current not exceeding 30 mA; Separate RCD for multiple outputs. Telecommunication port of the EV supply equipment according to IS 13252 (Part 1) : 2010. OCPP(Open charge point protocol) 1.6J upgradable to ocpp 2.0. Device Should follow 17017 series of IS codes in general and the installation of the system shall comply with relevent IS Codes.
525Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:(A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level(C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection /connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA (Phase & Total), Frequency, KWH, PF6. LED Indicating lamps for load on mains and load on set.7. Fuse/ MCB for instruments.8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor.10. Supply failure timer.11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring400KVA
526SUB HEAD-XIII - EXTERNAL LIGHTINGSupplying and erecting approved make 9 Mtr. Octagonal pole made from HR sheet steel Long 70 mm Top X 155 mm bottom dia, 3 mm thickness with 260mmX260mmX16mm base plate, 4-M24 Bolts and 750mm long with necessary G.I. J Bolts .Approx Pole weight 97 kg. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, suitable suspend local wind speed with integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable termination to be erected With Suitable foundation (Included) as per details given by manufacturer considering site requirement. Single arm, 1500-2000 mm
527Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 100 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%),, Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) Charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, with Lithium-Iron Phosphate Battery (LiFePO4), charging time 8-10 hours, Battery backup time 12 hours (minimum), LED fixture watt 35 watt, Input voltage: 12V DC, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPR 15 , lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K (As per American National Standard Institute (ANSI Bin)), life time (LED, Driver & electrical circuitry)of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).100 watt (System lumen efficacy >120 lm/Watt)
528Supplying, Installation, Testing and commissiong of 10 W, 5700 K, IP 66 decorative LED bollard, with CRI 80, Life of LED 50000K @L70 , PF >0.9 with die cast Aluminium housing with corrosion resistance powder coating using nano technology in approved color suitable for landscape application with control gear and overall height of 1000 mm - 1100 mm with base flange / plate suitable for mounting above ground level, with foundation complete as required.
529Supplying, Installation, Testing and commissiong of 3 mtr high MS decorative type steel tubular pole duly primed and painted. The pole shall be painted with MRF polyurethane paint of approved colour. The bottom and middle embellishments are cast in iron and fixed to the column by grub screw. The column shall be provided with inbuilt loop box with 4 way 32 Amp Heavy duty connector, 1 No SPMCB with wiring from MCB to fitting with 3x2.5 sq.mm PVC insulated sigle core wires and shall have matching flush door,fabricated painted complete with RCC foundation including foundation bolts, suitable DWC/ PVC pipe laid within the foundation for incoming and outgoing cables as per the Department's requirement.
530Supplying, Installation, Testing and commissiong of 40 watt LED Post Top lanteran fitting, heavy duty copper wound ballst and accessories.
531Supply and fixing 25 Watt LED Type Post top Gate Light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc. on GI bracket for Gate Light or on Pole of building including connection with FR PVC insulated copper conductor cable and earthing the body etc. as required.
532Supply of Raising & Lowering type 16M high mast system with following:Mast shaft shall be in two sections, hot dip galvanised, inside and outside in singledip, suitable for wind velocity as per IS 875 part 3. There shall be only one longitudinal seam weld per section and no circumferential weld. It shall also include accessories for high mast including head frame, 2-point suspension system with steel wire rope 6mm dia (7/19 construction) double drum winch, Galvanished Lantern carriage arrangement suitable for up to 12 luminaires symmetrically, lightning final and integral power tool for raising and lowering operation of the High Mast.Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates. Suppy of Non-integral flood light luminaire IP-65 with 2x 400W LED and its control gear boxes - 6 Nos.400W LED light fitting - 12 Nos.Supply of twin dome aviation obstruction lights LED Type - 1 No.Supply of control panel housing suitable control circuit for switching ON and OFF of the mast. It shall also have suitable controls for operation of Power Tool.Construction of suitable shallow foundation with 'M20' grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2mt depth, suitable DWC / PVC pipe laid within the foundation for incomming and outgoing cables with all materials and labour.Erection of High Mast with help of suitable equipments and wiring of luminaires with all wiring material and labour.Provision of GI pipe earthing for High Mast with 4.5M long 40mm dia GI pipe including connection of High Mast earth terminal with 25 x 3mm GI flats with all materials and labour.Installation of control panel on suitable foundation including all materials and labour.Supply, Testing and Commissioning of above High Mast system.
533Supply of following sizes and core PVC/ XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 vlots. (Conforms to IS:1554, part-1). 4 Core, 16 sq.mm. XLPE Aluminium Cable
534Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
535Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia
536Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
537Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
538Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
539Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
540Supply and fixing of floor mounting, totally enclosed, compartmentalized, cubical, dust, vermin proof and Outdoor type ROAD LIGHTING PILLAR fabricated out of 2mm thick cold rolled carbon anealed CRCA, sheet steel, intermnally strengthened with angle iron frame work with following incoming and outgoing feeders (fabricatedout of 2mm CRCA sheet steel) including supplying and mounting including making connectins / interconnections with lugs / glands crimping tools, testing and commissioning of following items inside the panel/pillar. The pillar shall be suitable for automatic operation of external lighting.Road Light pillarIncoming100 A TP MCCB (25KA) -1 No.100 A, TP Contactor-1 No.Time Switch with daily dial suitable for operation on 230V single phase 50Hz AC supply -2No.Auto Manual Selector Switch - 1 No.Bus BarsTPN Al bus bar of 200A ratingOutgoings 20A DP MCB - 4 No.32A DP MCB - 4 No.Indication lamps (LED Type) - 3 No.SITC of Road lighting Pillar of above details & specifications
541SUB HEAD-XIV-STP, OWC & WTP Influent ParameterpH : 6.5 ~ 8.0BOD5 : 200 ~ 250 mg/LCOD : 550 ~ 600 mg/LSuspended Solids : 200 ~ 240 mg/LOil & Grease : 40 mg/LTotal Nitrogen: 45 mg/LTreated Water Parameter (After Packaged Unit) After UF (For reuse flushing)pH : 6.5 ~ 8.5 pH : 6.5 ~ 8.5 BOD5 : < =10 mg/L BOD5 : <=6 mg/LCOD : < 50 mg/L COD : < 50 mg/LSuspended Solids : < 10 mg/l Suspended Solids : <=2 mg/LOil & Grease : <=5 mg/L Oil & Grease : <1 mg/LTotal Nitrogen : < 10 mg/L Total Nitrogen : < 10 mg/LFecal Coliform : < 100 MPN/100ml Fecal Coliform : < 100 MPN/100mlNote: Water can be use for irrigation/gardening purpose without UF, After UF it will be used for flushing purpose. Design ParameterPlant Capacity : 50KLDTechnology : Advanced FRP packaged Hybrid (Anaerobic + Aerobic(MBBR)) based STP, Warranty10 Year Structural warranty shall be provided for FRP structure.1 year warranty on electrical components against manufacturing defect only.Packaged STP Product Highlights & Feature Details* Size & MOC Compact FRP tanks with a footprint of approx 60% of conventional plants.* Power Consumption Upto 70% to 80% lower in comparison to conventional plants.* Smell No smell during regular operations.* Sound much less than conventional. * Position Can be Installed both Above Ground or Below Ground* Operations 1. Monthly grit removal based on raw sewage conditions. 2. Excess sludge removal every six monthsor later based on raw sewage load 3. Dedicated manpower is not required for operations of STP. DescriptionSTP FOR ELECTRO-MECHANICAL EQUIPMENTSDesign, Engineering, and providing all equipment /machinery at site, installation and commissioning of equipments/ electrical/ piping and STP GA drawings to be provided by the vendor, Packaged prefabricated FRP STP Unit including DMF\\"Supply Installation testing commmissioning of 50KLD capacity advanced Prefabricated and packaged STP (MOC: 100% FRP - 14 to 15 mm thickness with UV protective coating), Design flow 2.5 m3/hr , Pick flow- 3times, Inlet and outlet size 150mm and tank volume of 50m3 (Length 9 mtr X width 2.5 mtr X Height 2.8mtr) OR length and width may adjust as per site requirement)with comprising of the following:1. Separation and Primary Sedimentation Chamber2. Anaerobic/Anoxic Chamber3. Moving Bed Bio Reactor (Aerobic)4. Secondary Sedimentation Chamber5. Disinfection Chamber6. In Built recirculation Line 7. Manhole covers8. Diapragm Air Blowers - 9- Filter feed pump- 2Nos Submercible/Monobloc + DMF- 1Nos.10. Wire Ropes for Fixing the STP tank\\"QTY- SET-1, Make- BS Enviro/SusbioAdditional Equipment as per requirementSITC of Grinder Pump (1W+1S) + SITC of Diapragm/Channel Blower for EQT including air grid- 1SET, Including electrical provisions- Make of Pumps- Lubi/KBL (Required in case of above ground plant)SITC of UF system for 50 KL all pumps should be in (1W+1S) provision, including PLC panel,system should be run on automode, required dosing pumps and 1Nos CIP--all 1Set, Make- Pump-KBL/Lubi, Membrane- Toray/Dupont/Grafil/Mitsubishi (Required In case of reuse for flushing)Flow meters- 1Nos. for Inlet Electro magnetic type and 1Nos for Outlet digital type.Make- AsterInstrumention
542RO Plant(WTP) 5000LPHFeed Pumps (1 Working + 1 Stand by)\\"Supply, installing, testing and commissioning of Horizondal /vertical Centrifugal Pump of suitable capacity for feed pump withfollowing specifications\\"Type : Horizontal, CentrifugalCapacity : 8.4 m3/HrHead : 24-26 mMOC of Casing : ciMOC of Impeller : ciMOC of shaft : ss Make : KIRLOSKAR/CRI/WILO/LUBIMulti Grade filter \\"Supply, installing, testing and Commissioning of MGF filterassembly.\\"Capacity : 8.4 m3/hrDIA- 700 MMMOC- FRPMake- pentair/tataActivated carbon filter\\"Supply, installing, testing and Commissioning of ACF filterassembly.\\"Capacity : 8.4 m3/hrDIA- 700 MMMOC- FRPMake- pentair/tataMicron filter assemblySupply, installing, testing and Commissioning of Cartridge filter assembly.Capacity : 8.4 m3/hrMicron Rating : 5 MicronMOC of Housing : PVCMOC of filter element : PPMake-Big Blue / aster/ Eq.Dosing System (Antiscalent, ph correctin, smbs)Supply, installing, testing and commissioning of dosing system with following specifications The Dosing system shall consist of Electronic dosing pump with positive displacement type with adjustable knob. The system shall also include chemical solution tank of reputed make.Capacity of Tank : 100 LitersMOC : HDPETank Make- Sintex/eq.Capacity of Pump : 0- 10LPHMOC : PPType of Pump : Electronic Metering PumpMake : e doseHigh Pressure Pump (1 Working + 1 Stand by)\\"Supply, installing, testing and commissioning of Vertical highpressure Pump of suitable capacity with following specifications\\"Type : Vertical Multi Stage,CentrifugalCapacity : 8.4m3/hrHead : 110-120 MMOC of Casing : SSMOC of Impeller : SSMake :kirloskar/CRI/lubiRO Membrane\\"Supply, installing, testing and commissioning of Reverse Osmosis Membrane of suitable capacity with followingspecifications\\"Size : Ø8\\"RO Feed : 8400 LPHRO Permeate : 60 %\\"Vendor has to considered the requirement suitable for thedesigned flow rate.\\"Make : Ge/ Dow/TorrayMembrane housingsSupply, installing, testing and commissioning of Membrane Housing for Reverse Osmosis Membrane of suitable capacity with following specifications.MOC : High grade FRPPressure Rating : 300 PSI\\"Vendor has to considered the requirement suitable for thedesigned flow rate.\\"Make : Pentair / DopxRO SkidSupply, installing, testing and commissioning of RO Skid SS-304 is to fix the pump , RO Membrane and all the accessories considering the project lead time and assembly of pipe lines, membrane housings.CIP pumps (1 Working + 1 Stand by)Supply, installing, testing and commissioning of Horizondal /vertical Centrifugal Pump of suitable capacity for feed pump with following specificationsType : Horizontal, CentrifugalCapacity : 8.4 m3/HrHead : 25 mMOC : ssMake- kirloskar/lubi/wiloChemical Cleaning Tank (CIP Tank)Supply, installing, testing and commissioning HDPE tank of 1000 Ltr.Make : SintexInstruments for RO System\\"Supply, installing, testing and commissioning of Instrumentswith following specifications.\\"1.Required Pressure Gauges for RO System2.Pressure switches for RO System3.Required Float Switches4.Rotameters5.Conductivity Meter6.PH MeterNote : All Instruments to be provided at the inlet and outlet of RO Plant with Interconnecting piping and electricals.Inter Connecting Piping with in RO systemFrom filter feed pump to upto otlet of membrane including necessary fittings, valves etc. complete in all respect.Low pressure side MOC : UPVCHigh pressure side MOC : SS 304Electrical WorksSupply, installation, testing and commissioning of electrical panel with required size of cable connecting to all electrical component within the system including pumps, pressure switch, sensor, dosing pumps etc.A complete Job
543Supply, installation in position, testing and commissioning of Organic Waste Converter of capacity 450 Kg /day (completely automatic type aerobic OWC), comprising aerobic composting machine in SS 304 grade for shaft, mixing blades & other wetted B1 parts and MS powder coated exterior parts, Mounted/standalone/Assembled Electrically driven Shredder with all wetted parts in SS 304, inbuilt curing system with moisture control, automatic temperature control system, automatic start and shutoff provision, segregation table, leachate collection tray of suitable nos., manure collection bags/trays, conveyor for loading and unloading(in case of standalone shredder), VFD based system, pressure gauge, piping, valve and all accessories to complete the job. The cost shall be inclusive of all necessary consumables (Enzymes etc.) required for O&M period and also providing electrical control panel, cabling and earth termination etc., and all accessories complete. The system proposed fully automatic composting machine, it does not require labour, No manual intervention and No maintenance. Volume reduction is 80 - 90 %, reducing space requirement for composting storage. The technology provided is on micro-organism based 24 hrs fully automatic composting machine.
544Sub Head XIX: Plumbing Pumps Supplying, installing, testing and commissioning of flooded Vertical Inline cetrifugal pump set with stainless steel body , stainless steel impller and SS shaft capable to deliver of following capacity and head. given by TFC squirrels induction motor suitable for operation on 415 volt , 50 HZ AC power supply running speed 2900 RPM .The installation shall be complete with all necessary ancillaries & accessories including base plate , coupling guard etc complete as required. Flow rate : 150 LPM Head : 70 MtsRequired for : UG T ( Domestic Water & Flusing Water )
545Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries etc required.Flow rate : 100 LPMHead : 15 Mts Solid Handling : 10 – 12 MMPurpose : DrainageMOC : CI
546Sub Head XX : Fire Fighting SystemSupply, installation, testing & commissioning of electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sp.cm. at highest and farthest oulet at specified flow of 2850 lpm at 100M. head conforming to IS 1520.Suitable HP SQ cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.
547Supplying, Installation, Testing and Commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sp.cm. at highest and farthest oulet at specified flow of 2850 lpm at 100 M. head conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment, sealed maintenance free batteries, Diesel Tank, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.
548Supplying, Installation, Testing and Commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following: complete in all respect as required.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm, at 100M head conforming to IS:1520.Suitable HP SQ cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.
549TERRACE PUMPSITC of electrical-driven terrace pump complete with electrical panel suitable for automatic operation and consisting of following, complete in all respect as required:Horizontal type centrifugal split-casing pump of cast-iron body and bronze impaller with stainless steel shaft conforming to IS:1520Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415V 3-phase 50Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted-type class F insulation conforming to IS:325MS fabricated common base plate, coupling, coupling guard, foundation bolt etc. as required:Suitable cement concrete foundation duly plastered with anti vibration pads.450LPM at 35 m. head
550Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm. Thick CRCA sheet, dust and vermin proof, powder coated of approved shade after 7 tank treatment process cable alley, inter-connection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50 HZ. AC Supply with enclosure protection class IP 42 as required.Terrace Pump Control Panel (for 450LPM Pump)Incomer 100 Amps. TP MCCB.25 KAVoltmeter (0-500 Volt) with selector switchAmmeter (0- 100 Amps.) with Selector switchSet of 3 Phase indication lampSuitable HP fully Automatic star delta starter with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.selector switch for local / remote , auto/ manual/ off operation, On/Off indication lamp
551Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 HZ. AC supply with enclosure protection class IP 42 as required.COMMON PANEL IN FIRE PUMP HOUSEINCOMERa) 630 Amps. TP & MCCB 50 KAb) Voltmeter (0-500 Volts) with selector switchc) Ameter (0-300 Amps.) with selector switch & CT's etcd) Set of 3 Phase indicating lamp.e) Set of Al. bus bar 500 Amps.OUTGOING : ( Electrical Fire / Sprinkler Pump ) 2 Nos Electrical Driven fire Pump. 250 Amps. TP& MCCB-35K with suitable HP fully automatic star/delta starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.2 Nos Jockey pump. 100 Amps. TP & N MCCB-25 KA with suitable HP fully automatic star/delta starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/munual/OFF operation.DIESEL ENGINE CONTROLControl for Diesel Engine comprising:-Auto/Manual selector switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode.Indication lamp for High/Low Lub. Oil pressure, High Water Temp. and Engine ON indication.Battery charger suitable for 12 V/24V DC with boost and tickle selector switch, 0-15 V/ 0-30 V Dcvolt merer, 0-20A DC Ammeter.All standard relays and accessories for automatic operation of diesel engine.SYSTEM CONTROLLERDesigning, Supply, Installation, Testing and Commissioning of system controller to control operation of Main Electric Fire Pump, Diesel Pump, Pressurisation Pump, in sequence as per specification consisting of relays, times, sensors, annunciation window for fault indication, complete as per specification.
552Suitable cement concrete foundation duly plastered with anti vibration pads. Supplying and making end termination with brass Compression Gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/XLPE Al.conductor cables of 1.1 KV grade as required 3.5x300 sq.mm (3½ X 300 sq. mm (70mm))
553Suitable cement concrete foundation duly plastered with anti vibration pads. Supplying and making end termination with brass Compression Gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/XLPE Al.conductor cables of 1.1 KV grade as required 3.5x50 sq.mm (3½ X 50 sq. mm (35mm) )
554Suitable cement concrete foundation duly plastered with anti vibration pads. Supplying and making end termination with brass Compression Gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/XLPE Al.conductor cables of 1.1 KV grade as required 4x25 sq.mm (4 X 25 sq. mm (28mm) )
555Suitable cement concrete foundation duly plastered with anti vibration pads. Supplying and making end termination with brass Compression Gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/XLPE Al.conductor cables of 1.1 KV grade as required 3x120 sq.mm (3 X 120 sq. mm (45mm))
556Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width x 50mm depth x 1.6 mm thickness.
557Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 4 core, 25 sq.mm. Aluminium Armoured
558Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 3.5 core, 50 sq.mm. Aluminium Armoured
559Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 3 core, 120 sq.mm. Aluminium Armoured
560Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 3.5 core, 300 sq.mm. Aluminium Armoured
561Earthing with GI Earth plate 600 mm x 600 mm x 6 mm th.including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe with charcoal or coke and salt complete as required.
562Providing & fixing 25 mm x 5 mm G.I. Strip in 40 mm dia GI pipe from earth electrode including connections with GI nut, bolt, spring, washer excavation and re-filling etc. as required.
563Providing & fixing 25 mm x 5 mm G.I. Strip in on surface or in recess for connections etc as required.
564Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing as required.
565Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 300 mm (W) x 50 mm (D) x 1.6 mm (T)
566Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required 150 mm dia
567Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required 100 mm dia
568Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required 80 mm dia
569Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 200 mm dia
570Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 mm dia
571Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 100 mm dia
572Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 80 mm dia
573Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 65 mm dia
574Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 50 mm dia
575Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 40mm dia
576Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 32 mm dia
577Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 25 mm dia
578Supplying and fixing single headed internal hydrant valve with instantanous Gun metal couplings of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal cap and chain as required
579Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gun metal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal cap and chain as required.
580Supplying, fixing, testing and commissioning of following size butterfly valve (manual) with CI body SS disc nitrile sheet & O-ring & PN 1.6 pressure rating as specified. 50 mm dia
581Supplying, fixing, testing and commissioning of following size butterfly valve (manual) with CI body SS disc nitrile sheet & O-ring & PN 1.6 pressure rating as specified. 80 mm dia
582Supplying, fixing, testing and commissioning of following size butterfly valve (manual) with CI body SS disc nitrile sheet & O-ring & PN 1.6 pressure rating as specified. 100 mm dia
583Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts bolts washers, gaskets and conforming to IS 780 of following size asrequired: 150 mm dia
584Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts bolts washers, gaskets and conforming to IS 780 of following size asrequired: 200 mm dia
585Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
586Supplying, fixing, testing and commissioning, of following sizes of non return valve with C I body 80 mm dia
587Supplying, fixing, testing and commissioning, of following sizes of non return valve with C I body 100 mm dia
588Supplying, fixing, testing and commissioning, of following sizes of non return valve with C I body 150 mm dia
589Supplying, fixing, testing and commissioning of following size Y-Strainer of ductile CI body flanged ends with stainless steel strainer as specified. 100 mm dia
590Supplying, fixing, testing and commissioning of following size Y-Strainer of ductile CI body flanged ends with stainless steel strainer as specified. 200 mm dia
591Supplying and fixing 63mm dia, 15mtr. Long RRL hose pipe with 63mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required.
592Supplying and fixing First-Aid-Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with upto date amendments, complete with the following as required.30 m long 20mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 1258520 mm (nominal internal) dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipments on wall.Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe
593Supplying and fixing fire hose cabinet fabricated from 16 gauge M.S. Sheet with single or double glazed front door (with 4 mm thick glass) and locking arrangement, painted fire red with stove enamelled paint \\"FIRE HOSE\\" written on front including necessary supports approximate size. a)750mm x 600mm x 250mm deep. (External)
594Providing and fixing Fire hose cabinet door (40mm x 40mm x 5mm) angle depth fabricated with 2100mm x 1200mm MS sheet. Complete in all respect with 25mmx25mmx3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on glass at internal hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above door to close opening i/c painting etc. as required. Glass shall be 6 mm thick.
595Supply and fixing 63mm dia Gun Metal branch pipe with 20mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
596Supplying and fixing following fire brigade connection of cast iron body with Gun metal male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required. 2 Way FBC of Cl body
5974 Way FBC of Cl body
598Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with Air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel pain of approved shade as required.
599Providing fixing testing & commissioning of 15 mm size quartzoid bulb type sprinklers, of rating 68 degree C. pendent / upright with required accessories. Sprinkler (Pendent / Upright)
600Side Wall Speinkler
601Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
602Providing & fixing Auto Air release valve for fire hydent and sprinkler, suitable for pressure not less than 15 Kg/Sq.cm. 25 mm dia
603Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100 mm dia
604Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
605Providing and fixing stainless steel standard Fireman's Axe with heavy insulated rubber handle tested to 20000 volts as per IS : 926 complete.
606Supply, installation, testing and commissioning of 150 mm dia Installation Control Valve inclusive of 2 nos 150 mm dia Butterfly Valve, strainer, Alarm Valve with Water Motor Gong, Pressure Gauges, Test Lines with Ball Valves with necessary MS Class \\"C\\" piping with threaded fittings of required sizes. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.
607Providing, installing, testing & commisioning of fire brigade draw out connection (fire department connection) with suction pipe MS class 'C' 100 mm dia. & 100 mm dia. foot valve & steel chain including wall mounted box M.S. construction made out of 16 gauge MS Sheet with glass door to house the above mentioned componenets. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge. (to be connected to static water tank) It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.
608Providing and fixing mechanical foam type(ISI marked) fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket ISI marked as per IS 933 finished externally with red enamel paint and fixed to wall with brackets complete with internal charger. Capacity 6 kg. I.S.I. Marked.
609Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal dischargetube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. I.S.I. Marked.
610HVACSUB HEAD 'A' - EQUIPMENTS Water Chilling UnitWater Cooled Screw ChillerSupply, Installation, Testing and Commissioning of AHRI Certified Water Cooled Screw chiller with VFD each having a minimum Nominal capacity of 325 TR and actual capacity not less than 325 TR at chilled water inlet/outlet temperature of 54°F/44°F with chilled water circulation rate of 780 USGPM at chiller Fouling Factor 0.0005 FPS and condenser water inlet/outlet temperature of 90°F/97.5°F with circulation rate of 1235 USGPM at condenser Fouling Factor 0.001 FPS, suitable for operation on refrigerant R-134a for screw type machine each comprising of the following complete as per specifications and as required. Quoted price shall include price of Variable Frequency Drive starter of suitable capacity (Chiller shall have compressor of same OEM make)Mono/Twin rotor based semi-hermetic type horizontal compressor complete with automatic capacity control from 100%-20%, safety switches, forced feed lubrication system etc, Suitable capacity squirrel cage induction motor with class 'B' insulation suitable for operation on 415+/-10% volts, 50Hz, A.C. supply.Unit mounted IP 54 rated VFD Starter of suitable capacityNecessary drive arrangement.1 set - Lubrication device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, and automatic pressure regulating valve, oil heater, oil heater thermal switch etc. 1 no. - matching shell and tube type even pass water cooled condenser of M.S. shell and integrally finned copper tubes and pressure drop not exceeding 10 metres as per CPWD Specs1 no. - matching shell & tube flooded/falling film type even water pass chiller for screw type units of MS shell and copper tubes and pressure drop not exceeding 10.0 metres as per CPWD SepcsEvaporator and condenser shall be manufactured, tested and stamped with ASME(U) pressure vessel code.1 Lot - Refrigerant piping fittings, valves and accessories to inter connect compressor, condenser, chiller and expansion valve.1 set - Microprocessor based control panel complete with accessories as per specifications.Lot - Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc.Lot - Water flow switches at outlet of condenser & chiller, water drain, air purge valves, thermometers and pressure gauges wherever required.Lot - Suction line and chiller insulation with minimum 19 mm thick polyvinyl nitrile rubber insulation complete as required.Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs.Lot- Initial/first charge of refrigerant gas & compressor oil shall be factory charged.Lot- RCC / cement concrete foundation for the chilling unit.Chilling machine described above, as per specifications and complete in all respects for the operating parameters as given under. Refrigerant should be R-134aAt least one Chiller shall be tested at 4 points at 100%, 75%, 50% and 25% at AHRI conditions at manufacturer test bed before despatch.The chilling machine as described shall meet the following.Minimum COP at AHRI Conditions = 6.20 min. IKW/TR at Full Load = 0.65 max.NPLV at design conditions not exceeding 0.32 IKW/TRIPLV at AHRI conditions not exceeding 0.32 IKW/TRManufacturer’s AHRI Certified Selection Performance Sheet to be submitted to evaluate and verify the specified performance parametersSupply, Installation, testing & commissioning of water chilling m/c including transit insurance, transportation, loading & unloading, lifting & shifting etc.Capacity : 325 TR Actual (2 # Working 1 # Standby) BEE 4 Star Rating
611Chiller Plant Optimization BMS Machine:Intel Quad Core processor (Latest Technology), Windows® 2010 SP2 or above operating System, 1 TB HDD, 8 GB RAM, Enhanced graphic Card, DVD Combo Drive, Ethernet Port with 32\\" color monitor flat screen LED display, multimedia keyboard & optical mouse and microsoft office 2013 and anti virus as per Specification.
612Chiller Plant Optimizer(CPO) should have algorithm to match the real time damand load with the chiller maximum COP operating condition. CPO should be capabile of operating VFD's to maintain optimal water flow on evaporator and condensor side of the chiller. It should also optimize the machine run time and the machine sequencing/scheduling to get the best system efficiency. It should also generate alarms in case of abnormal operating range. CPO should be complete with software, enclosure/Panel. Note- CPM shall not be accepted.
613Field Devices Immersion temp sensor
614Outside T+rh
615Water Pressure transmitter
616Water Level Switch
617Cables 2 x 1 sq.mm Copper Shielded unarmoured cable for signal and power as per specification. (for I/O points hard wired to DDC).
61825 mm thick PVC conduit.
619CAT 6 A unarmoured cables with required accessories like RJ45 connector etc.
6203 x 1.5 sq.mm Shielded unarmoured cable for signal and power as per specification. (power Cable).
621\\"Pumps Primary Chilled Water PumpsSupply, Installation, Testing and Commissioning of vertical inline Split coupled chilled water circulating pump set capable of delivering water against a head of 12 meters complete with motor, .as per specifications and drawings.\\"1 No. Vertical Inline Long Coupled type pump1 No. suitable HP, TEFC squirrrel cage induction motor with class \\"F\\" insulation, 1450 rpm sunchronous speed, operating on 415 ±10% volt, 3 phase, 50 htz A.C supply,Suitable for outdoor application.2 Nos. 200 mm dia. Dail type pressure gauges (range-0-5 kg/cm2)Duly insulated with 40 kg/cum density close cell elatromeric Nitrile rubber insulation. cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications.Minimum Required Efficiency of Pump-70 %M.O.C of Impeller- BRONZEThe pumps shall be provided with cast iron suction guides and Triple Duty Valve (PN-16) factory fitted1 No. -Vertical Inline split coupled type single stage pump with bronze impellar, S.S Shaft, CI body and outside fitted balanced mechanical seal and Pump casing should be PN 16 rated.Chilled water 2964 LPM at 12 M head (2 # Working 1 # Standby)
622Secondary Chilled water pumpsSupply, Installation, Testing and Commissioning of vertical inline Split coupled chilled water circulating pump set capable of delivering water against a head of 25 meters complete with motor, VFD shall be motor mounted with (IP-55) protection for Sensorless Control and VFD shows flow and head on its display all the time and separate Pump Logic controller etc.as per specifications and drawings.\\"Variable Pumps must be provided with a cloud-based subscription service that enables Active Performance Management. It must proactively tracks and manages pump performance and provides early diagnostic messaging, web accessible trends and analysis along with automated reports helping end customer to make performance-based decisions and take immediate action to deliver the best possible HVAC pump performance.The cloud based subscription should deliver real-time alerts, such as:\\"1) Alarms & warnings on excessive vibration,2) Pump in hand,3) Dead head,4) Cavitation\\"5) BrokenCoupling6) VFDandMotorOverheatingThe connectivity kit supplied by OEM/authorized representative should have ability to connect and provide real time data for upto 8 pumps in a single plant room.\\"The pumps shall be provided with cast iron suction guides and Triple Duty Valve (PN-16) factory fitted1 No. -Vertical Inline split coupled type single stage pump with bronze impellar, S.S Shaft, CI body and outside fitted balanced mechanical seal and Pump casing should be PN 16 rated.Duly insulated with 40 kg/cum density close cell elatromeric Nitrile rubber insulation. cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications.Chilled water 2964 LPM at 25 M head (2 # Working 1 # Standby)
623Condenser Water PumpsSupply, Installation, Testing and Commissioning of vertical inline Split coupled condenser water circulating pump set capable of delivering water against a head of 30 meters complete with motor, VFD shall be motor mounted with (IP-55) protection for Sensorless Control and VFD shows flow and head on its display all the time and separate Pump Logic controller etc.as per specifications and drawings.Variable Pumps must be provided with a cloud-based subscription service that enables Active Performance Management. It must proactively tracks and manages pump performance and provides early diagnostic messaging, web accessible trends and analysis along with automated reports helping end customer to make performance-based decisions and take immediate action to deliver the best possible HVAC pump performance.The cloud based subscription should deliver real-time alerts, such as:1) Alarms & warnings on excessive vibration,2) Pump in hand, 3) Dead head,4) Cavitation\\"5) BrokenCoupling6) VFDandMotorOverheatingThe connectivity kit supplied by OEM/authorized representative should have ability to connect and provide real time data for upto 8 pumps in a single plant room.\\"The pumps shall be provided with cast iron suction guides and Triple Duty Valve (PN-16) factory fitted1 No. -Vertical Inline split coupled type single stage pump with bronze impellar, S.S Shaft, CI body and outside fitted balanced mechanical seal and Pump casing should be PN 16 rated.Duly insulated with 40 kg/cum density close cell elatromeric Nitrile rubber insulation. cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications.The pump characteristic shall be as follows:Chilled water 4693 LPM at 30 M head (1 standby) (2 # Working 1 # Standby)
624FRP Cooling TowerSupply, installation, testing and commissioning of CTI Approved FRP cooling tower of 12,09,600 Kcal/hr heat rejection capacity with FRP water basin, PVC fillings with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow fan direct drivan or driven through speed reduction gear box with TEFC induction motor, suction screen, make up- quick fill arrangement, over flow and drain pipe connections with valves and suitable inspection ladder, access arangement for cooling tower interier, cement concrete foundation, steel/masonary supporting structure, anti vibration mountings etc. as per specifications and as required. 2 coats of coating STARCOAT FRP Required.400 TR capacity @ 25.6 Deg.C Wb (Ambient) (2 # Working)Flow Rate : 4693 LPMMotor (11 KW x 2 Fan)Cooling Tower 'IN' Temp. : 36.4oCCooling Tower 'OUT' Temp.: 32.2oC
625Air - Dirt SeparatorSupply installation testing and commisioning of Deaerator-dirt separator. Flanged connections, complete with Brass drain valve 1” F (from DN 50 to DN 150), 2” F (from DN 200 to DN 300). complete with a set of concentric metal mesh surfaces to create the swirling motion required to facilitate the release of micro-bubbles and dirt to the surfaces. Epoxy resin coated steel body. Brass automatic air vent valve body. Stainless steel internal element. PP float. Brass float guide and stem. Stainless steel float lever and spring. EPDM hydraulic seals. Medium water and non-hazardous glycol solutions excluded from the guidelines of EC directive 67/548; maximum percentage of glycol 50%. Maximum working pressure 10 bar. Working temperature range 0–110°C. Particle separation rating down to 5µ. Working temperature range 0–100°C. Floor brackets as per site requirement. Third Party test report is required to be submit by contractor from manufacturer for 5µ Particle separation (TNO)Dia-250 (Closed Loop)
626SUB HEAD 'B' - EQUIPMENTS Air Handling UnitFloor mounted suspendedSupplying, installing, testing and commissioning of factory built Floor mounted double skin type air handling units Eurovent Certified made of 40 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and G.I sheet of thickness 0.8mm inside layer with polyurethane foam (PUF) insulation of density 42 kg/m3 factory injected between them by injection moulding machine, complete with Direct Driven Backward Curved Aerofoil Plug Type Fans with VFD's with aluminium finned copper tubes (tubes thickness not less than 0.5 mm), filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron, Direct Drive package with TEFC (EFF-1) suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box, drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc. TP isolator with MS enclosure box should be Provided. etc, complete as per specifications of following capacities: 15000 CFM (37.5 TR), 30 Sqft. Coil Area, 65 mm static pressure. 6 row for summer cooling.
627SUB HEAD 'B' - EQUIPMENTS Air Handling UnitFloor mounted suspendedSupplying, installing, testing and commissioning of factory built Floor mounted double skin type air handling units Eurovent Certified made of 40 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and G.I sheet of thickness 0.8mm inside layer with polyurethane foam (PUF) insulation of density 42 kg/m3 factory injected between them by injection moulding machine, complete with Direct Driven Backward Curved Aerofoil Plug Type Fans with VFD's with aluminium finned copper tubes (tubes thickness not less than 0.5 mm), filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron, Direct Drive package with TEFC (EFF-1) suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box, drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc. TP isolator with MS enclosure box should be Provided. etc, complete as per specifications of following capacities: 14000 CFM (35 TR), 28 Sqft. Coil Area, 65 mm static pressure. 6 row for summer cooling.
628SUB HEAD 'B' - EQUIPMENTS Air Handling UnitFloor mounted suspendedSupplying, installing, testing and commissioning of factory built Floor mounted double skin type air handling units Eurovent Certified made of 40 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and G.I sheet of thickness 0.8mm inside layer with polyurethane foam (PUF) insulation of density 42 kg/m3 factory injected between them by injection moulding machine, complete with Direct Driven Backward Curved Aerofoil Plug Type Fans with VFD's with aluminium finned copper tubes (tubes thickness not less than 0.5 mm), filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron, Direct Drive package with TEFC (EFF-1) suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box, drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc. TP isolator with MS enclosure box should be Provided. etc, complete as per specifications of following capacities: 10000 CFM (25 TR), 20 Sqft. Coil Area, 65 mm static pressure. 6 row for summer cooling.
629SUB HEAD 'B' - EQUIPMENTS Air Handling UnitFloor mounted suspendedSupplying, installing, testing and commissioning of factory built Floor mounted double skin type air handling units Eurovent Certified made of 40 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and G.I sheet of thickness 0.8mm inside layer with polyurethane foam (PUF) insulation of density 42 kg/m3 factory injected between them by injection moulding machine, complete with Direct Driven Backward Curved Aerofoil Plug Type Fans with VFD's with aluminium finned copper tubes (tubes thickness not less than 0.5 mm), filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron, Direct Drive package with TEFC (EFF-1) suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box, drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc. TP isolator with MS enclosure box should be Provided. etc, complete as per specifications of following capacities: 2000 CFM (5 TR), 4.0 Sqft. Coil Area, 40 mm static pressure. 4 row for summer cooling.
630CASSETTE FAN COIL UNITSupply, installation, testing and commissioning of Chilled Water Ceiling Suspended Hydronic Cassette type fan coil unit, four(4) way directional flow, low noise, each complete with two(2) rows of deep chilled water cooling coil, multi-blade centrifugal fan, test reports from National Accreditation Board for Testing and Calibration Laboratories (NABL)/AHRI accredited lab, electronic air cleaning system, required set of ball valves with & without strainers & 2 way Motorized valve, insulated condensate drain pans with drain pump assembly & drain pump failure alarm, pipe connections through copper pipes, Infra-red remote control, Liquid Crystal Display (LCD), four (4) speed motor , fan four(4) direction air flow, auto swing louver, decorative panel etc., condensation drain connections, All units shall be suitable for 220 +/- 10% Volts, 50 Hz, single phase power supply etc. complete as per specification. The wireless Remote temperature control / thermostat shall have memory back up for set point re-store in case of power failure and re-start. Four(4)hanger rods with required anchoring fasteners, hooks, washers etc.complete as per CPWD specification and as directed by Engineer-in- charge.4.0 TR nominal capacity with 1600 CFM air quantity.
631AHU's Controls/Dynamic Balancing ValvesSupply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.Water flow rate 7.4-14.4USGPM, 32 MM
632AHU's Controls/Dynamic Balancing ValvesSupply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.Water flow rate 41.62.4 USGPM, 65 MM
633AHU's Controls/Dynamic Balancing ValvesSupply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.Water flow rate 62.64-120 USGPM, 80 MM
634AHU's Controls/Dynamic Balancing ValvesSupply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.Modulating Thermostats
635UVGI (Ultra Violet Germicidal Irradiation) SYSTEM Supply, Installation , testing , commissioning and handing over of the imported Ultra Violet Germicidial Irradiatons ( UVGI) (AHU Coil) System for maintaining indoor Air Quality.The System can be UL listed for fire safety. The components of the system must be in strict conformity with the specifications.and shall be including freight from Delhi Airport to site ,Insurance,Lifting,Shifting etc.as required . The prices to include all inter connected wiring between the UVGI Lamps. 10000 CFM T0 15000 CFM
636SUB HEAD 'C' - PIPING WORKS Plumbing (Chilled Pipe)Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled/hot water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) . as per specifications and as required.The Pipes size 150mm & below shall be M.S. heavy class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. & from minimum 7mm thick M.S. sheet for pipes of 400 mm dia. & above.\\"Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.)duly insulated with following closed cell nitrile rubber with 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc, insulation covered with a STARBOND 30-36, Anti-Fungal, Fire retardant insulation protective coating, tested as per ASTM D 4804, ASTM E 84, ASTM D-5035-11, ASTM D 1777-64 and ASTM D 3776-09, finally finished with 2 layers of Insulation protective coating to provide complete seal against air and moisture/resistance against mechanical impact, scratch, weather resistance with the properties of mold, fungus and bacterial resistance. The coating surface flame spread should be 0 and smoke developed should be also 0, coating should also comply with NFPA 90A & 90B- 25/50 for parameter and the VOC level of the coating should comply with LEED IEQ 4.2 i.e. VOC level should be below than 50 gram/litter and it should also comply the guidelines of MIA 3316C- Class 1 & Grade A. as per specifications and as required.Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.\\"\\"The pipes shall be joined using Grooved Couplings & Fittings from 20 mm and above. The Rigid Couplings shall be Angle Pad Design and shall be in Installation ready condition from 2\\"\\" - 12\\"\\". Couplings above 12\\"\\" shall need AGS Groove. Tongue & Recess Couplings are not allowed. Grooved Flexible Couplings shall be used in lieu of Rubber Bellows for Attenuation of Vibration and Expansion - Contraction , DeflectionThe Minimum working pressure rating should be above 400 psi for these sizes upto 12\\"\\". Welding is not allowed to join pipes.\\"\\"Insulation Thickness Range 1. DIA 25 -32 MM - 19 MM2. DIA 40 -400 MM -32 MM\\"300 MM
637250 MM
638200 MM
639150 MM
640125 MM
641100 MM
64280 MM
64365 MM
64450 MM
64540 MM
64632 MM
64725 MM
648Supplying, fixing, testing and commissioning of following PN-10 Rating valves, strainers, gauges in the chilled water plumbing duly insulated to the same specification as the connected piping and adequetly supported as per specifications. Butterfly ValvesBUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified200 MM
649Supplying, fixing, testing and commissioning of following PN-10 Rating valves, strainers, gauges in the chilled water plumbing duly insulated to the same specification as the connected piping and adequetly supported as per specifications. Butterfly ValvesBUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified80 MM
650Supplying, fixing, testing and commissioning of following PN-10 Rating valves, strainers, gauges in the chilled water plumbing duly insulated to the same specification as the connected piping and adequetly supported as per specifications. Butterfly ValvesBUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified65 MM
651Ball Valves with strainer '32 MM
652Ball Valves without strainer '32 MM
653Motorized Butterfly Valves Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. 200 MM
654Balancing Valves BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 200 MM
655Non-Return Valves NON - RETURN VALVE with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. 200 MM
656Suction GuideProviding and fixing of suction guide of following sizes in the inlet of chilled water pumps as per specifications200 MM
657Y - StrainersY - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.80 MM
658Y - StrainersY - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.65 MM
659Pressure Gauges Providing and fixing pressure gauge with gauge cock, thermowell. complete as per specifications and drawings.
660Thermometers with thermowellProviding and fixing thermometer Mercury filled V form type complete as per speci-fications and drawings.
661Flow SwitchesProviding and fixing water flow switch on chilled water outlet complete as per specifications and drawings.
662Automatic Air VentsProviding and fixing auto airvent purging valve complete as per specification and drawings.
663Thermowell of 15 mm dia.(Test Point)Providing and fixing thermowell on chilled water pipe complete as per specifications and drawings.
664Condenser Water PipingSupplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc( Paracoat BPC coating for Buried Pipeline). as per specification and as required complete in all respect.Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.350 MM
665250 MM
666200 MM
66780 MM
668Butterfly ValvesBUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.250 MM
669Motorized Butterfly Valves Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. 250 MM
670Balancing ValvesBALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.250 MM
671Non-Return ValvesNON - RETURN VALVE with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. 250 MM
672Suction GuideProviding and fixing of suction guide of following sizes in the inlet of condense water pumps as per specifications and drawings. 250 MM
673POT StrainerProviding and fixing of pot strainer in the condenser water pipe as per specifications and drawings.350 MM
674Pressure Gauges Providing and fixing pressure gauge with gauge cock, thermowell. complete as per specifications and drawings.
675Thermometers with thermowellProviding and fixing thermometer Mercury filled V form type complete as per speci-fications and drawings.
676Flow SwitchesProviding and fixing water flow switch on chilled water outlet complete as per specifications and drawings.
677Thermowell (Test Point)Providing and fixing thermowell on chilled water pipe complete as per specifications and drawings.
678On-line non-chemical water treatment systemSupply, Installation, Testing and Commissioning of On line, Non-Chemical Water Treatment Scale Preventor System : “Scale Guard / Caliphi” for 325 TR AC Chiller, having flow rate 4693 LPM
679Expansion tank\\"Supply, installation, testing, balancing and commissioning of PRESSURISED CHILLED WATER EXPANSION TANK along with necessary accessories such as air vents, Safety Valves, Pressurisation pumps and its panel , with required Support & Foundation etc. in order to keep chilled water system under pressure and to prevent entrapment of air in the system. The tank shall be precharged M.S expansion tank with replaceable heavy duty butyl rubber bladder. The tank shall have 20 mm drain and charging valve connection to facilitate the onsite charging of the tank to meet system requirement. The tank shall be fabricated as per Indian standard code for “non-fired pressure vessels” and the flanges shall be as per IS 6392-1971. For chilled/hot water application, it will be insulated with 50mm thick insulation to the specifications and cladded with STARBOND 30-36, Anti-Fungal, Fire retardant insulation protective coating, tested as per ASTM D 4804, ASTM E 84, ASTM D-5035-11, ASTM D 1777-64 and ASTM D 3776-09, finally finished with 2 layers of Insulation protective coating to provide complete seal against air and moisture/resistance against mechanical impact, scratch, weather resistance with the properties of mold, fungus and bacterial resistance. The coating surface flame spread should be 0 and smoke developed should be also 0, coating should also comply with NFPA 90A & 90B- 25/50 for parameter and the VOC level of the coating should comply with LEED IEQ 4.2 i.e. VOC level should be below than 50 gram/litter and it should also comply the guidelines of MIA 3316C- Class 1 &. Grade A. \\"\\"Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc( Paracoat BPC coating for Buried Pipeline). as per specification and as required complete in all respect.Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.\\"1500 LTRS
680Drain PipingG. I. drain piping of 'B' Class complete with fittings, supports, valves and 2 layers of 6 mm thick Polyethylene Foam (Kinney Foam) insulation as per specifications and drawings. Providng and fixing pipes with all necessary fittings, supports and insulation.50 mm dia
681Drain PipingG. I. drain piping of 'B' Class complete with fittings, supports, valves and 2 layers of 6 mm thick Polyethylene Foam (Kinney Foam) insulation as per specifications and drawings. Providng and fixing pipes with all necessary fittings, supports and insulation.40 mm dia
682Drain PipingG. I. drain piping of 'B' Class complete with fittings, supports, valves and 2 layers of 6 mm thick Polyethylene Foam (Kinney Foam) insulation as per specifications and drawings. Providng and fixing pipes with all necessary fittings, supports and insulation.32 mm dia
683SUB HEAD 'D' AIR DISTRIBUTION DuctingSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.G.I. Sheet Metal Ducting (Rectangular)0.63 mm (24 Ga)
684SUB HEAD 'D' AIR DISTRIBUTION DuctingSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.G.I. Sheet Metal Ducting (Rectangular)'0.80 mm (22 G)
685SUB HEAD 'D' AIR DISTRIBUTION DuctingSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.G.I. Sheet Metal Ducting (Rectangular)1.0 mm ( 20 G)
686SUB HEAD 'D' AIR DISTRIBUTION DuctingSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.G.I. Sheet Metal Ducting (Rectangular)1.25 mm ( 18 G)
687G.I. Sheet Metal Ducting (Spiral/Oval)Supply, fabrication, installation and testing of G.S.S. factory fabricated insulated spiral duct made in two layers with insulation sandwitched in between two layers, finished with silver powder coat. The ducting shall comply with the latest IS / SMACNA standard and complete with spliter, damper, vanes etc as required complying with standard secifications and as per approved shop drawings. The insulation used shall be of closed cell, Fire retardant, self extinguishing type crossed linked polyethylene insulation of 25 mm thick, density not less than 24 Kg/cu.m, 'K' value not more than 0.028 Kcal/degC with adhesive tape etc. Duct shall be supplied as per size given bellow. 0.63 mm (24 Ga)
688G.I. Sheet Metal Ducting (Spiral/Oval)Supply, fabrication, installation and testing of G.S.S. factory fabricated insulated spiral duct made in two layers with insulation sandwitched in between two layers, finished with silver powder coat. The ducting shall comply with the latest IS / SMACNA standard and complete with spliter, damper, vanes etc as required complying with standard secifications and as per approved shop drawings. The insulation used shall be of closed cell, Fire retardant, self extinguishing type crossed linked polyethylene insulation of 25 mm thick, density not less than 24 Kg/cu.m, 'K' value not more than 0.028 Kcal/degC with adhesive tape etc. Duct shall be supplied as per size given bellow. 0.8 mm (22 Ga)
689G.I. Sheet Metal Ducting (Spiral/Oval)Supply, fabrication, installation and testing of G.S.S. factory fabricated insulated spiral duct made in two layers with insulation sandwitched in between two layers, finished with silver powder coat. The ducting shall comply with the latest IS / SMACNA standard and complete with spliter, damper, vanes etc as required complying with standard secifications and as per approved shop drawings. The insulation used shall be of closed cell, Fire retardant, self extinguishing type crossed linked polyethylene insulation of 25 mm thick, density not less than 24 Kg/cu.m, 'K' value not more than 0.028 Kcal/degC with adhesive tape etc. Duct shall be supplied as per size given bellow. 1.0 mm (20 Ga)
690Duct InsulationSupply,Installation, testing & commissioning of Closed cell, Fire retardant (Class \\"O\\") , self extinguishing type crossed linked polyethylene insulation density not less than 24 Kg/sqM, 'K' value not more than 0.028 Kcal/degC with adhesive tape etc. on ducts complete as per specification and drawings. All insulation is to be adhered to the duct surface uniformly and no air bubbles are allowed anywhere. 19 mm
691Duct InsulationSupply,Installation, testing & commissioning of Closed cell, Fire retardant (Class \\"O\\") , self extinguishing type crossed linked polyethylene insulation density not less than 24 Kg/sqM, 'K' value not more than 0.028 Kcal/degC with adhesive tape etc. on ducts complete as per specification and drawings. All insulation is to be adhered to the duct surface uniformly and no air bubbles are allowed anywhere. 25 mm
692Duct Acoustic LiningSupplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.50 MM thick(for AHU ROOM)
693Underdeck Insulation Supply and installation of SMART PIR Panels- 20 mm thick with 80 micron embossed Aluminium foil on both the sides
694Application- Underdeck InsulationPanel size- (4 Mtr length x 1.2 mtr Width)Polymer Chair profile between Sheet
695Grilles/Diffusers Supply,installation, testing and commissioning supply and return air grilles/ diffusers as per specifications and drawings including fixing frame of G.I./wooden in false ceiling/walls.Aluminium supply air grilles with volume control
696Aluminium Return air grilles without volume control
697Duct Volume Control dampers
698Aluminium S/A Square diffuser with volume control damper damper with with anti smudge ring & removable core
699Aluminium R/A square diffuser without volume control damper with anti smudge ring & removable core
700Aluminium Exhaust air Grill with damper
701Fresh/Exhaust air Louvers with VCD,Bird screen/wire mesh etc.
702Flexible Duct ConnectionSupply,installation,testing and commissioning of fire retardant nonporous double layer flexible canvass connection between each indoor unit and ducting.
703Fire DamperSupplying, Fixing, testing and commissioning of fire dampers insupply air duct/main branch and return air path as and whererequired of required sizes i/c control wiring,the damper shall bemotorized and spring return so as to close the damper in theevent of power failure automatically and open the same in caseof power being restored. The spring return action shall beinbuilt mechanism and not externally mounted. The dampershall also be closed in the event of fire signal complete asrequired and as per specifications.Supply air fire damper
704Return air fire damper
705Spring return acturtor with panel of Motorised actuator for Dampers
706Fire rated coating for DuctAll insulated chilled water duct insulation shall be coated with STARBOND 30-36 Anti-Fungal insulation protective coating in conjunction with 7mil non-combustible certified Parafab GFC woven fiber glass cloth, tested as per BS 476 part Ignitability 5,Fire Propagation 6, ASTM D 4804, ASTM E 84, ASTM D-5035-11, ASTM D 1777-64 and ASTM D 3776-09, finally finished with 2 layers of Insulation protective coating to provide complete seal against air and moisture/resistance against mechanical impact, scratch, weather resistance with the properties of mold, fungus and bacterial resistance, coating should also comply with NFPA 90A &amp; 90B- 25/50 for parameter and the VOC level of the coating should comply with LEED IEQ 4.2 i.e. VOC level should be below than 50 gram/litter and it should also comply the guidelines of BS standard- Class 0.(For Indoor & amp; Outdoor Duct Application of Airconditioning)
707Fire Rated Paint : Supplying, Application & Commissioning for fire rated paint (Starcoat CRC) CBRI approved and tested for 2 hours as per BS 476 part 6, 7, 20 & 24 duct Vertical & Horizontal for Kitchen Extraction Duct, Car Parking Duct, Duct Crossing Fire compartment, Ventilation Duct along with all the necessary accessories (Sealant- Chemxseal 32-17 & Class O Gasket) etc. Details shall be as per tender specifications.
708SUB HEAD 'E' VENTILATION WORKS Inline FansSupplying, Installing, Testing and Commissioning of Inline fans complete with motor, supporting frame, gravity louvres,etc. as per drawings and specifications.400 CFM @ 12 mm static
709Propeller Fans'Supplying, Installing, Testing and Commissioning of propeller fans complete with motor, supporting frame, gravity louvres,etc. as per drawings and specifications.225 mm dia. @ 8 mm wg
710Pressurization FansSupplying, installation, testing and commissioning of Tube Axial flow fan suitable for outdoor application of following capacity with GSS casing and aluminium alloy impellers with high efficiency (efficiency-2) aero-foil sections, blades, the impeller directly driven by TEFC induction motor, suitable for 3 Phase 50 Hz 415 V ± 10 %,1400 RPM of class 'F' insulation etc. complete as required and as per specifications (20 mm Static Pressure WC) (For Pressurization of lift lobby, lift well, stairwell). TP isolator with MS enclosure box should be Provided.21000 CFM @ 35 mm wg for pressurization of Staircase
711Pressurization FansSupplying, installation, testing and commissioning of Tube Axial flow fan suitable for outdoor application of following capacity with GSS casing and aluminium alloy impellers with high efficiency (efficiency-2) aero-foil sections, blades, the impeller directly driven by TEFC induction motor, suitable for 3 Phase 50 Hz 415 V ± 10 %,1400 RPM of class 'F' insulation etc. complete as required and as per specifications (20 mm Static Pressure WC) (For Pressurization of lift lobby, lift well, stairwell). TP isolator with MS enclosure box should be Provided.21000 CFM @ 35 mm wg for pressurization of Lift Lobby
712Pressurization FansSupplying, installation, testing and commissioning of Tube Axial flow fan suitable for outdoor application of following capacity with GSS casing and aluminium alloy impellers with high efficiency (efficiency-2) aero-foil sections, blades, the impeller directly driven by TEFC induction motor, suitable for 3 Phase 50 Hz 415 V ± 10 %,1400 RPM of class 'F' insulation etc. complete as required and as per specifications (20 mm Static Pressure WC) (For Pressurization of lift lobby, lift well, stairwell). TP isolator with MS enclosure box should be Provided.16000 CFM @ 20 mm wg for pressurization of Lift Well
713Smoke ExtractionSupplying, installation, testing and commissioning of supply air Tube Axial flow fan with 20 mmWC Static Pressure of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor (motor should be of high efficiency (efficiency 1) suitable for 3 Phase 50 Hz 415 V ± 10 %,1400 RPM of class 'H' insulation etc. complete as required and as per specifications. TP isolator with MS enclosure box should be Provided.30000 CFM (Car Parking)
714Axial Flow FanSupplying, installation, testing and commissioning of supply air Tube Axial flow fan with 20 mmWC Static Pressure of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor (motor should be of high efficiency (efficiency 1) suitable for 3 Phase 50 Hz 415 V ± 10 %,1400 RPM of class 'F' insulation etc. complete as required and as per specifications. TP isolator with MS enclosure box should be Provided.2100 CFM (Pump Room)
715Axial Flow FanSupplying, installation, testing and commissioning of supply air Tube Axial flow fan with 20 mmWC Static Pressure of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor (motor should be of high efficiency (efficiency 1) suitable for 3 Phase 50 Hz 415 V ± 10 %,1400 RPM of class 'F' insulation etc. complete as required and as per specifications. TP isolator with MS enclosure box should be Provided.5000 CFM (STP)
716SUB HEAD 'F' - ELECTRICAL WORKSElectrical Control PanelPlant Room AC PANEL- Main PanelSupplying, assembling, erecting, connecting, testing and commissioning of dust, damp and vermin proof free floor standing factory built sheet steel enclosed non-drawout modular type Panel fabricated out of suitable sized angle iron and flats, base channel and covered with 2.0mm thick PCRC sheet, duly painted complete with earth bus, aluminium bus bar, numbering & sign writing, interconnection & including the cost of connection through bus bar / copper conductor flexible connection with all accessories, rotary handles,phase barriers etc. complete as shown in drawing & as per specifications and mounted with the followings etc. complete as required. (All the starters should have NO/ NC contacts for remote/ fire control facility etc. complete) Incoming:2 Nos 800 A, 415V, 50 KA 4P, electrical draw out type, Micro-processor based release (for over current and Earth fault protections) A.C.B. with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required with following accessories:Digital flush type class- I accuracy with power load manager, showing V, A, KVA, KWH etc. with 3 Nos. current transformers of 2000/5A ratio, 10 VA Class 1.0 metering.1 Set of RYB phase indicating & ON/OFF/TRIP LED lamps with 2Amps. SP MCB's backup.Bus coupler:1 set, 2000 A, 415V, 50 KA 4 Pole, electrical draw out type, A.C.B. with all indications, push buttons etc. complete in all respects as mentioned in specifications and as required with ON/OFF/TRIP indications. Arrangement to be considered as required to couple with existing panel.Interlocking to be considered as required.Bus Bars:Electrolytic high conductivity aluminium three phase and neutral busbars rated at 415V, 50 Hz., 1500 amps. insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.Outgoing:-All outgoing feeders shall be provided with On indicating lamp with 2 A SP MCB protection & resin cast CT's class-1 suitable rating with digital Amps. meter. 500 A TPN MCCB '35 KA' with TM release etc. with MFM showing V,A, KWH, KVA & ON/OFF/Trip indications, complete - 3 set (for chillers) ( 2 WORKING,1 STAND BY)63 A TPN MCCB '25 KA' with TM release etc. complete - 3 set (Primary pumps) ( Spare for future)80A TPN MCCB '25 KA' with TM release etc. complete - 3 set (Secondary pumps) ( Spare for future)100 A TPN MCCB '25 KA' with TM release etc. complete - 3 set (Condenser Pump) ( Spare for future)Fully automatic star delta starter suitable for 1 nos. of 11 KW motor including suitable MPCB type-2 selection, CT's, Ammeter, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control wiring etc. Complete for each - 3 Set (PRIMARY Pumps)Fully automatic star delta starter suitable for 37 KW motor including suitable MPCB type-2 selection, CT's, Ammeter, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control wiring etc. Complete - 2 Set (Cooling Tower)Fully automatic DOL starter suitable for 11 KW motor including suitable MPCB type-2 selection, CT's, Ammeter, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control wiring etc. Complete - 2 Set (Plant Room Vetilation Fans)
717Supplying, installation, testing and commissioning of MV panel board of cubical type, compartmentalised design fabricated from 2.0 mm thick CRCA sheet having necessary cable alleys, powder coated through seven-tank process facility for pricking and degreasing, including connections and inter connections as per specifications complete with following accessories as required( supply panels in each AHU room). Panel - P2 (AHU & Fan)OUTGOING1 No. 16 Amps MCB 10 KA for 1.1-3.7 KW motor1 No. DOL Starter1 No. single phase preventer MPRD-2 type1 No. ammeter 2 Nos indicating lights2 Nos. Push buttons
718Panel - P3 (AHU)OUTGOING1 No. 63 Amps MCB 10 KA for 9.3 - 15 KW motor1 No. Star delta Starter1 No. single phase preventer MPRD-2 type1 No. ammeter 2 Nos indicating lights2 Nos. Push buttons
719Panel - P4(PRESS. & Car Parking)OUTGOING1 No. 63 Amps MCB 10 KA for 9.3 - 15 KW motor1 No. Star delta Starter1 No. single phase preventer MPRD-2 type1 No. ammeter 2 Nos indicating lights2 Nos. Push buttons
720Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 3 1/2 Core - 300 mm2
721Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 3 1/2 Core - 185 mm2
722Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 3 1/2 Core - 150 mm2
723Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 3 1/2 Core - 120 mm2
724Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 4 Core - 35 mm2 - COPPER
725Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 4 Core - 25 mm2 - COPPER
726Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 4 core - 16 mm2 - COPPER
727Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 4 core - 10 mm2 - COPPER
728Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 4 core - 6 mm2 - COPPER
729Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 4 core - 4 mm2 - COPPER
730Providing and fixing PVC insulated armoured aluminium conductor cables (3 1/2 Core) & COPPER CABLE (4 CORE) from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings. 4 core - 2.5 mm2 - COPPER
731Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
732Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
733Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for earth connection etc. complete as required.
734Providing and fixing 6 SWG dia GI wire on surgace or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring/ cable as required.
735Supply and Installation of Automatic boom barrier shall be consisting of following specifications. Barrier Front Design: Round Barrier, Colour : Silver/Grey Colour, PARKI Electromechanical Drive ,Mechanism 3-6 meters boom arm Illuminated, Boom Arm (Red/Green) ,Opening Speed : 1.5 Sec Reverse on Obstable Detection , intelligent control mechanism, Automatic Fault Detection Arrow , Led Indication on barrier body (Red/Green) ,Duty Cycle 100 %, IP Rating : IP 55, RS 485 Communication complete in all respect.
736Supply and Installation of Entry Ticket dispensor shall be consisting of following specifications. High-quality Entry terminal with Integrated ticket request button , Button Panel Color : Silver/Grey/white Barcode ticket, QR code ticket Proximity Card/mifare/EM card Ticket up to 7000 tickets from one roll, Graphical LCD-Display , Intelligent Control board, Inbuilt Loop Detector,Communication with the data controller in RS485 or TCPIP, Operating ambient temperature -35°C/+65°C, Offline work capability Inbuilt intercom,Heater and fan with inbuilt thermostat , Support variety of cards complete in all respect.
737Supply and Installation Automatic License plate image capturing camera shall be consisting of following specifications , Embedded with LPR algorithm inside the camera ,Support plate cutout, overview picture snap shot and video recording, Embedded with White list database,control the barrier Powerful 2.7-12mm motorized lens and IR light, ideal for monitor ANPR distance as 3~8m Wide , IP67,IK10 and superior performance for outdoor applications ,True WDR technology complete in all respect.
738Supply and Installation Of Zone Display (Two Row Display) Multi-Colour LED Matrix Directional Display unit Cabinet Colour : Black , Cabinet Dimension : 200 mm x 320 mm LED Color : Multi Colour.Communication : RS232/RS485/Ethernet. Led Type 5mm Oval Visibility 120mtr Brightness 2000 MCD , Enclosure Weatherproof IP grade HOUSYS CPU Speed 100 MIPS.
739Supply and Installation of Long Range Reader shall be consisting of following specifications , Hands Free Frequency Range: ISM 865~868MHz or ISM 902~928MHz ,Operation Mode: FHSS Data Ports: Wiegand26/34, RS485, RS232, RJ45 ,Reading Range: 12m ,Reading Clue: Buzzer Antenna,Built-in line polarization Operation Temp -20℃ to +80℃ ,Access Controller : NAC 25, 2 reader controller, Card holder: 54000 cards, Logs: 60000 records,Alarm events: 10000 events, Communication: TCP/IP, Verification: card, card and timing. Release button, Remote opening from software, timing. complete in all respect.
740Supply and Installation of Loop Detector shall be consisting of following specifications ,Vehicle sensing unit with 2 channel sensing option, 24 V DC/24 V AC power supply ,designed D MAX chipset 3 level frequency adjustment, 3 level sensitivity adjustment ,IP protected Enclosure, Presence relay (N.O./N.C.) Multi-function signaling LED Operating ambient temperature -20°C to 60 °C C,NO,NC. 3 Poles, Communication : RS485/Ethernet complete in all respect .
741Supply and Installation of Inductive Vehicle loop sensor shall be consisting of following specifications . Loop wire single core 1.5 sqmm Electromegnectic induction coil specialized loop sensor design loop size 2m X 1 cutting depth 20 mm cutting width 15 mm rectangular box with 2 x 1 with chamfered cutting edge Four turns in rectangular shape 3 level sensitivity adjustment complete in all respect.
742Supply and Installation of Manned Exit Station shall be consisting of following specifications.: Intel I3, with 3 MB cache, CPU 4460@ 3.2 Ghz, 4 GB RAM, 500 GB HDD 19\\" LCD Monitor, Keyboard & Mouse, Microsoft Windows XP Professional license, Parking Management Software, Graphic User Display, Image Verification Module integrated , intelligent master controlling panel ,Repecipt Printer, Barcode Scanner, Proximity Card Reader, Network Switch complete in all respect.
743Supply and Installation of Central Management Station shall be consisting of following specifications. Intel I5, with 3 MB cache, CPU 4460@ 3.2 Ghz, 16 GB RAM, 500GB HDD 19\\" LCD Monitor, Keyboard & Mouse ,Microsoft 11 Windows Professional license Hardware parameter updates and upgradation .PARK ADMIN Graphical, clear presentation of the parking system Checking and controlling of the devices. Functional alarm message reporting with direct access to detailed information, Administering customer and card data and issuing various types of tickets Tariff module for the convenient design of car park tariffs. PARK TARIFF Car park-specific tariff configuration ,Temporal tariff validity ,Tariffs for various payment types. PARK REPORT Tabular and, graphical presentation of car park data in various statistical and report formats with numerous settings .Occupancy statics Periodical statics, Value range statics Revenue statics ( ticket type, payment type) Season parker statics complete in all respect. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57590591
AUTHORITY Government Departments
TENDER VALUE 128.23 Crore
LAST DATE 22-10-2026
Authority
Authority Name Delhi State Industrial And Infrastructure Development Corporation Limited
Work Description Tender for Development Of Integrated Office Complex At The Existing Dtc Depot, Ip Estate, New Delhi. S/H : Composite Works Of Construction Of Dtc Hq Building (2B+G+11 Stories) With Reinforced Cement Concrete Framed Structure Design Including Water Supply, Sanitary Installation, Internal And External Electrical Installations, Firefighting, Av System, Access Control, Cctv System, Lifts, Lan Bms, Hvac (Low Side & Hi Side) Horticulture Works, Vertical Plantation Works, Artworks, External Development Works And All Other Related Works All Complete Including 3 Year Dlp At Dtc Bus Depot At Ip Estate, New Delhi.
Basic Detail
Tender No 01/2026-27/CD-15
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 19 Sep 2026
Submission Date 22 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 128.23 Crore
Tender Fee Ref. Documents
EMD 1.38 Crore
Exemption Not Available
Document List
BOQ_398339.xls
c7da6698-89b0-4256-9e0f-afb0f5c79e30.html
nittd01cd15.pdf
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 31 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 31 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_398339.xls

html

c7da6698-89b0-4256-9e0f-afb0f5c79e30.html

pdf

nittd01cd15.pdf

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail