Tender For repair maintenance Specialized Electrical & Mechanical Services At 33 Sham Nath Marg, Delhi (Sh:- Operation Of E&M Services & Miscellaneous Electrical Work).
Tender Value
20.42 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
5 days left
EMD
40859
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for repair maintenance Specialized Electrical & Mechanical Services At 33 Sham Nath Marg, Delhi (Sh:- Operation Of E&M Services & Miscellaneous Electrical Work).
BOQ
| Sl. No. | Item Description |
| 1 | Routine maintenance and attending day to day complaints of electrical installations and compound/security lights along with allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode by deploying following staffs on all working days execluding Sunday & Holidays etc. complete as required.(a) Wireman-cum-Operator - 2 Nos. (General Shift)(b) Khallasi - 1 No. ( General Shift) |
| 2 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a)3 x 1. 5 sq. mm |
| 3 | b) 3 x 2. 5 sq. mm |
| 4 | c)3 x 4 sq. mm |
| 5 | d) 3 x 6 sq. mm |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 A switch |
| 7 | b)15/16 A switch |
| 8 | c) 6 pin 15/16 A socket outlet |
| 9 | d) Telephone socket outlet |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 11 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.a) 250 Amp, 35 KA, TPMCCB |
| 12 | b) 100 Amp, 16 KA, TPMCCB |
| 13 | LED Panel light 2x2 ft. (System lumen efficacy =120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2. 5 KV with Short & Open circuit protection, THD < 10%, P. F. =0. 95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1. 20 mm)a) 36 watt |
| 14 | LED Batten light (System lumen efficacy =120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2. 5 KV with Short & Open circuit protection, THD < 10%, P. F. =0. 95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 <135 lm/Watt outputPowder coated die cast /Extruded aluminum Body (Thickness > 1. 20 mm)36 watt |
| 15 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy =120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F. =0. 95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 100 watt |
| 16 | b) 150 watt |
| 17 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy =120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F. =0. 95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 150 watt |
| 18 | b) 200 watt |
| 19 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0. 9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value = 6. 0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 20 | Supplying, installation, testing and commissioning of 400 mm sweep size wall mounted fan complete with inbuilt electronic regulator, blade, wire lead with moulded plug top etc. as required. |
| 21 | Supplying and installation of following size fresh air fan of plastic body suitable for 220 volts, 50 hz, AC supply, in the existing opening including making the hole to suit the size of the fan & making good the damages complete with connection, testing & commissioning etc. as required.(a) 250 mm sweep size |
| 22 | Supplying and fixing of 11 Fins Oil Filled Room Heater (ISI marked) with Min-1000W, Med-1300W, Max-2400W, adjustable thermostat, PTC heating element, over heat protection, castor wheels suitable for operation on 230V, 50Hz, single phase AC supply complete with testing & commissioning etc. as required. |
| 23 | Supplying and fixing of 1200 watt revolving room heater having 3 Nos halogen rod, made out of CRCA/plastic body with effective cord length, CRCA heat reflector, crome plating, dual safety assurance, suitable for operation on 230V, 50Hz, single phase AC supply complete with testing & commissioning etc. as required. |
| 24 | Supplying and fixing of Fan Room Heater with 2 positions of wattage Min-1000W to Max-1800W, adjustable thermostat for temperature control, thermal cut out for overheating protection, tip over protection, suitable for operation on 230V, 50Hz, single phase AC supply complete with testing etc. as required. |
| 25 | Supplying and laying of 3 x 4 sq.mm XLPE insulated & PVC sheathed copper conductor unarmoured flexible power cable of 1.1 KV grade on surface etc. as required. |
| 26 | Less for credit of old dismantle material like copper wire, conduit, box, MCB, MCCB, fans, light fitting etc. under buyback arrangement. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysSep 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer