Tender For Provision Of Deficient Married Accommodation For Officers(Lt Cdr & Above) At installation Agrani
Tender Value
9.50 Crore
Estimated cost
Bid Submission
29 Oct 2026
27 days left
EMD
8 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Deficient Married Accommodation For Officers(Lt Cdr & Above) At installation Agrani
BOQ
| Sl. No. | Item Description |
| 1 | Total amount of Sch 'A' part-I (Buildings/ Structures) |
| 2 | Total amount of Sch 'A' part-II (Excavation, Earthwork, Site Clearance & Site Development) |
| 3 | Total amount of Sch 'A' part-III (Internal water supply) |
| 4 | Total amount of Sch 'A' part-IV (Internal Electric Supply) |
| 5 | Total amount of Sch 'A' part- V (External Water Supply) |
| 6 | Total amount of Sch 'A' part-VI (External Electric Supply) |
| 7 | Total amount of Sch 'A' part-VII (Lightning Protection & Aviation Obstruction Light) |
| 8 | Total amount of Sch 'A' part-VIII (Area Drainage) |
| 9 | Total amount of Sch 'A' part-IX (Sewage Disposal) |
| 10 | Total amount of Sch 'A' part-X (Road/ Path/Hardstanding) |
| 11 | Total amount of Sch 'A' part-XI (Lift) |
| 12 | Total amount of Sch 'A' part- XII (Fire Fighting) |
| 13 | Total amount of Sch 'A' part-XIII (Demolition) |
| 14 | Total amount of Sch 'A' part-XIV (Rain Water Harvesting) |
| 15 | SCH. 'A' PART -XV (Miscellaneous B/R & E/M Items )Note :- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. |
| 16 | DEMOLITIONTaking down Bib tap 15mm dia all as specified and directed. |
| 17 | Taking down pillar tap 15mm dia all as specified and directed. |
| 18 | Taking down plate rack all as specified and directed. |
| 19 | Taking down kitchen sink all as specified and directed. |
| 20 | Taking down 15mm dia stop valve/angle valve all as specified and directed. |
| 21 | Taking down electric meter and deposited to store complete all as specified and directed. |
| 22 | Taking down electric water heater (Geyser) any capacity and deposited to store complete all as specified and directed. |
| 23 | ARBORICULTURESupply , laying and developing lawn with first quality grass of approved quality by excavating the lawn area to a depth not exceeding 30 cm in hard/dense soil, providing pesticides@ 500 grams per 100 Sqm area, and refilling with approved earth obtained from excavation to a depth of 20 cm depth filled with a mixture of manure, sand and red earth in (1:3:6) proportion incl cost of grass, sand, red earth , manures and pesticides and removing the surplus excavated earth to distance exc 1.50 km and not exceeding 5.00 km all as specified and as directed. |
| 24 | INTERNAL WATER SUPPLYS&F 15mm bore fancy type chromium plated long body bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed. |
| 25 | INTERNAL ELECTRIC SUPPLYM&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including medium grade PVC conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked for modular wiring of suitable size concealed modular box with inner and outer white cover plate (Same make of approved switch and socket and it will measured seperately) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S cable as earth continuity conductor to common earth and connecting to earth dolly and cutting chases for conduits/boxes etc complete all as specified and directed at site for :-one light/Bell point controlled by one 5/6 amps one way switch. |
| 26 | All as per item No 25 above but for one Ceiling fan point controlled by one 5/6 amps one way switch all as specified as directed. |
| 27 | All as per item No 25 above but for one exhaust fan point controlled by one 5/6 amps one way switch all as specified as directed. |
| 28 | All as per item No 25 above but for one Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin all as specified as directed. |
| 29 | All as per item No 25 above but for one Socket outlet, three/five pin, 5 Amp, same board controlled by one 5/6 amps one way switch all as specified as directed. |
| 30 | All as per item No 25 above but for one One light point controlled by 2 Nos, 2 Way switches 5/6 Amps all as specified as directed. |
| 31 | Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including medium grade PVC conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and cutting chases for steel conduits/boxes etc complete all as specified and directed at site for:-One 3/5 pin 15/16 amps socket outlet independent. |
| 32 | Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 4.0 Sq. mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including medium grade PVC conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 4.0 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and cutting chases for steel conduits/boxes etc complete all as specified and directed at site for AC points. |
| 33 | M&L for Starter switch of capacity 20A, including socket and plug top working on 240 Volts AC supply and suitable for Air conditioners all as specified and as directed. |
| 34 | Supply and fixing Modular metal clad socket with MCB 20 Amp SP complete all as specified and directed. |
| 35 | Supply ,install on wall testing and commissioning of Air insulated compact type Bus bar trunking 200Amps, Isc =15KA for 1 second for (G+5 Building of four risers in a duct for Main and essential supply) use on 3 phase 4 wire 415 volts,50 Hz,AC supply with metal clad enclosure having IP 54 rating after fixing the tap off boxes and all accesssories,made of 1.6mm thick steel sheet duly powder coatedin convenient sections complete with 4 Nos aluminium bus bars having current density of 130A/Sqcm at nominal current rating,necessary joints,elbow joints and expansion joints,fire barrier at each floor,continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including GI clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing syatem etc as specified and directed by Engineeer in charge and as per drg attached. |
| 36 | Supply, install test and commisioning End feed unit for above Air insulated compact Busbar trunking/raiser main use 3 phase,4 wire,415 volts,50Hz,AC supply made with 1.6mm thick steel sheet enclosue (IP-54) duly powder coated with MCCB TPN 63 Amps,16 KA Themo magnetic type complete with necessary joints all as specified and directed. |
| 37 | Supply, install, test and commisioning of plug in /tap off box on the existing Air insulated compact type bus trunking/rising mains for use on 3 phase 4 wire 415 volts ,50Hz,AC supply made with 1.6mm thich steel sheet enclosure (IP 54) duly powder coated with TPN MCCB 63 Amps ,16KA complete all specified and directed by Engineer in charge and as per drg attached. |
| 38 | Supply and fix automatic transfer switch, 3 phase 415 Volts,63 Amps capacity with manual mode and off postion options as specified and directed by Engineer in charge |
| 39 | Supply, Install, testing and Commissioning of Smart Meter of different as per BIS 16444 with communication technology including cellular/ RF/ Hybrid [Cellular+RF], AC whole current, three phase, Smart Energy Meter of rating 10-60 Amps complete as per specifications. Meter shall have the ability to communicate with Head End System (HES) on any one of the communication technologies mentioned in IS 16444 Part I (RF/Cellular) in a secure manner, in case of Cellular based meter, the meter shall accommodate e-SIM/ SIM of any service provider, the Smart Meters shall have a dedicated sealable slot for accommodating plug-in type bi-directional communication module which shall integrate the respective communication technology (RF/PLC/ Cellular) with the Smart Meters, leading to easy adaptability for network interfaces (WAN/NAN), the Plug-In module shall be field swappable/ replaceable complete all as specified and directed.Note: a) Meter Specification may please be read in co-junction with PS clause. Please Enable Macros to View BoQ information |
| 40 | Supply, Install, testing and Commissioning of Smart Meter of different as per BIS 16444 with communication technology including cellular/ RF/ Hybrid [Cellular+RF], AC whole current, three phase, Smart Energy Meter of rating 10-60 Amps complete as per specifications. Meter shall have the ability to communicate with Head End System (HES) on any one of the communication technologies mentioned in IS 16444 Part I (RF/Cellular) in a secure manner, in case of Cellular based meter, the meter shall accommodate e-SIM/ SIM of any service provider, the Smart Meters shall have a dedicated sealable slot for accommodating plug-in type bi-directional communication module which shall integrate the respective communication technology (RF/PLC/ Cellular) with the Smart Meters, leading to easy adaptability for network interfaces (WAN/NAN), the Plug-In module shall be field swappable/ replaceable complete all as specified and directed.Note: a) Meter Specification may please be read in co-junction with PS clause. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysNov 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 34 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender