Tender For Repair/Maint Of Lt Overhead Conductor, Underground Cable, Lt Panel And Allied Accessories And Repair/Replacement Of Submersible Pump Flashing Of Borewell And Allied Work In Stn Hq Bg Under Ge 881 Ews
Tender Value
28 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
23 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Lt Overhead Conductor, Underground Cable, Lt Panel And Allied Accessories And Repair/Replacement Of Submersible Pump Flashing Of Borewell And Allied Work In Stn Hq Bg Under Ge 881 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: REPAIR/MAINT OF LT OVERHEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES AND REPAIR/REPLACEMENT OF SUBMERSIBLE PUMP FLASHING OF BOREWELL AND ALLIED WORK IN STN HQ BG UNDER GE 881 EWS Contract No : GE/PNH-64/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 120 Sq mm including taking down old unserviceable cable complete all as specified and directed . |
| 3 | All as per item No.01 above but of size 95Sqmm 3.5 core all as specified and directed. |
| 4 | All as per item No.01 above but of size 70Sqmm 3.5 core all as specified and directed. |
| 5 | All as per item No.01 above but of size 50Sqmm 3.5 core all as specified and directed. |
| 6 | All as per item No.01 above but of size 35Sqmm 3.5 core all as specified and directed. |
| 7 | All as per item No.01 above but of size 25Sqmm 4 core all as specified and directed. |
| 8 | All as per item No.01 above but of size 16Sqmm 4 core all as specified and directed. |
| 9 | Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. and getting out in any type of soil, complete all as specified and directed. |
| 10 | All as per Item No.08 above but for depth exceeding 1.50 m and not exceeding 3m complete all as specified and directed. |
| 11 | Returning, filling in including spreading,leveling, watering and well ramming in layers n.exc 25cm thick in soil completed all as specified and directed. |
| 12 | Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point as in soil complete all as specified and directed. |
| 13 | Supply and laying dry sand cushioning with layers of sand 8 cm before laying of cable and 15 cm after laying of cable in trenches including punning of sand complete all as specified & directed. ( Note: Thickness after punning shall be measured and paid ) |
| 14 | Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed. |
| 15 | S&F in replacement GI tubing 80 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position all as specified and directed. |
| 16 | All as per item No.14 above but of size 50mm bore all as specified and directed. |
| 17 | All as per item No.14 above but of size 40mm bore all as specified and directed. |
| 18 | Making bore to road/cement path/hard standing for providing GI pipe of bore 40/50/80mm both end socketed for passing armoured cable including making good the disturbed surface complete all as specified and directed. |
| 19 | Locating the fault in LT cable of any size by any method or by manual as per the direction of Eng-in-charge and repair the same by providing straight through or end joints . Note: The joint and earth work will be measured and paid separately. |
| 20 | Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and S & F joint kit in replacement 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 95 Sqmm complete all as specified and directed. |
| 21 | All as per item No.19 above but of size 70 to 150Sqmm all as specified and directed. |
| 22 | All as per item No.19 above but of size 25 to 50Sqmm all as specified and directed. |
| 23 | S&F in replacement off load change over switch 415 Volt 320 Amp 4 Pole in sheet metal enlosure side handle opearted all as specified and directed. |
| 24 | S&F in replacement off load change over switch 415 Volt 250 Amp 4 Pole in sheet metal enlosure side handle opearted all as specified and directed. |
| 25 | S&F in replacement off load change over switch 415 Volt 200 Amp 4 Pole in sheet metal enlosure side handle opearted all as specified and directed. |
| 26 | S&F in replacement off load change over switch 415 Volt 100 Amp 4 Pole in sheet metal enlosure side handle opearted all as specified and directed. |
| 27 | Taking down existing unserviceable cross arms and providing new cross arms, bracing support clamps, back plate etc fabricated from structural steel section with bolts, nuts, washers etc on poles and painted with one coat of red oxide and two coats of aluminum paints complete all as specified and directed. |
| 28 | S&F in replacement ACSR conductor, stretching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sage in between span etc of any size and type complete all as specified and as directed by Engineer-in-charge. |
| 29 | S&F in replacement pin type insulator vitreous white/brown/green including one galvanized mild steel spindle and two galvanized iron washer and nut complete suitable for 1100 V grade 100mm height 65mm dia all as specified and directed. |
| 30 | Supply and fix in replacement disc insulator porcelain viterous,white , brown or green insulator including one galvanised mild steel spindle, two galvanised iron wahsers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed. |
| 31 | Supply and fix shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height in 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and directed. |
| 32 | Restretching properly and tightening ACSR conductor including rebinding aftes straining the single conductor on LT pole of any size replacing of jumpers if necessary all as directed by Engr-in-Charge. |
| 33 | S&F in replacement lightening arrestors expulsion type HT 11KV complete with all fittings, transmission class, discharge capacity 65 kilo amps with all fittings complete all as specified and directed. |
| 34 | PVC line separator for LT OH line suitable for 3 phase and neutral of capacity 1100 volts complete all as specified and directed. |
| 35 | M&L for painting the swaged steel tubular LT poles including cross arms,clamps and light brackets surface of any discription after preparation of old painted surface(removing old paint by paint removers and cleaning with scraper any number of existing coats) with one finishing coat aluminium paint and marking pole no. as per exesting numbers and painting of lower portion of pole in alternate layer of black and white shades/colour complete all as specified and directed. |
| 36 | S & F in replacement MCCB 63 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 37 | S & F in replacement MCCB 100 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 38 | S & F in replacement MCCB 160 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 39 | S & F in replacement MCCB 200 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 40 | S & F in replacement MCCB 250 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 41 | Disconnecting and taking out defective UG cable from trench/pole/pipe/floor/wall etc locate the fault, rectify the defects and relaying the XLPE cable UG PVC insulated and overall sheathed aluminium conductor heavy duty LT/HT 1.1/11 KV grade, connecting and testing for any size of cable complete as directed by Engr-in-Charge.Note; Excavation/earth work shall be measured and paid separaterly under relevent items of schedule. |
| 42 | S&F in replacement Steel tubular swaged poles complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31 (9 Metre long) complete and applying two coats of aluminium paint and plainting to band/strip with two coats of synthetic enamel paint including numbering of poles at a height of 1.5 mtr above ground level as per existing having 15mm width and 50mm bold letter including taking down of old one complete all as specified and directed. |
| 43 | Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 50 mtr complete all as specified and directed. (Note :- Item shall be executed twice in each installation during currency of contract and quantity is given for two operation. However unit rate to be quoted by the tenderer for single operation only) |
| 44 | M&L for triming of tree branches (touching HT/LT OH line)upto 10cm girth at any height carefully for making clearance upto 2.50 mts from over head line including taking shut down and disposal of tree branches debris at places where directed,complete all as specified and directed.Note:- Tools & plants including safety measures equipments like belt,ladder & ropes etc shall be arranged by the contractor at his own cost. |
| 45 | S&F in replacement rectangular type earth pit cover made out of heavy duty cast iron of size 12\\"x12\\" with MS frame of suitable size including all necessary masonary work for fixing of earth pit cover and including replacement of wire mesh( jali) ,funnel complete all as specified and directed. |
| 46 | M&L for Aluminium strip 25x3mm on FRP insulator fixed on wall/MS sheet or floors including connecting to lightening arrester/earthing test point, strip shall be brazed/welded at each joint complete all as specified and directed. |
| 47 | M&L for copper strip 20x3mm with saddles on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing test point strip shall be brazed/welded at each joint complete all as specified and directed. |
| 48 | Earthing complete with copper earth plate electrode 60 cm X 60 cm X 3.15 mm thick buried directly vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below normal ground level, surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to copper earth lead strip 25mm x 3mm upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe GI light grade 40mm bore, including wire mesh, funnel, lugs, excavation in any type of soil, returning filling in & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregates and pit cover slab 50mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates reinforced with welded steel wire fabric or XPM weighing not less than 4Kg/sqm with cast iron frame including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes:- (i) On testing if the desired earth resistance is not obtained,no payment shall be made till the desired earth resistance is not obtained. (ii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode. |
| 49 | Supply and fixing aluminium thimbles suitable for LT XLPE cable of size 95 to 150 Sqmm complete all as specified and directed. |
| 50 | Supply and fixing aluminium thimbles suitable for LT XLPE cable of size 35 to 70 Sqmm complete all as specified and directed. |
| 51 | Supply and fixing aluminium thimbles suitable for LT XLPE cable of size 16 to 25 Sqmm complete all as specified and directed. |
| 52 | Supply, fixing, testing & commissioning of LT weather proof panel board powder coated, outdoor type, double door shutter, made out of CRCA sheet 3 mm thick outer and 1.6 mm thick for inner door, confirming to IS 8623 with angle iron 50x50x6 mm, outdoor, floor mounting type with closed bus bar chamber and with Aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including PCC work, 0.6 Mtr above ground level, grouting etc including provision of suitable size of cable glands, cable lugs,nut, bolts,washers etc. (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron), including taking down old unserviceable panel board, complete all as specified and directed and comprising of the followings accessories:-INCOMING(a) MCCB 25 KA, 4 Pole, 63 Amps- 1 No. OUTGOING(a) Changeover Switch 63 Amps - 01 No.(a) MCCB TPN 63 KA, 63 Amps - 02 Nos(b) MCB SPN 40 Amps - 01 Nos (c) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & 300 Amps for neutral -1 No(d) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-300 Amps. Make: SECURE / MECO / C&S Electric/L&T(e) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No 0-500 V. Make: SECURE / MECO / C&S Electric/L&T(f) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder. |
| 53 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core flat of size 4 sqmm solid aluminium conductor complete all as specified and directed. |
| 54 | All as per item No.52 here in above but twin core 6 sqmm complete all as specified and directed. |
| 55 | All as per item No.52 here in above but twin core 10 sqmm complete all as specified and directed. |
| 56 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below normal ground level, surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to galvanised steel earth lead strip 25mm x 3mm upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe GI light grade 40mm bore, including wire mesh, funnel, lugs, excavation in any type of soil, returning filling in & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregates and pit cover slab 50mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates reinforced with welded steel wire fabric or XPM weighing not less than 4Kg/sqm with cast iron frame including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes:- (i) On testing if the desired earth resistance is not obtained,no payment shall be made till the desired earth resistance is not obtained. (ii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode. |
| 57 | Flushing of borewell complete by using 210 CMF compressor and heavy duty driller machine to deliver the high air pressure at the bottom of the bore well and cleaning/flushing the bore well till the water is become free from any mud and clear for portable complete all as specified and directed by Engineer-in-charge |
| 58 | Material & labour for replacement of GI column pipe 40 mm bore medium grade, 3 Mtrs in length , both end flanged, including nuts bolts, washer and rubber gaskets etc complete all as speicfied all as specified and directed by Engineer-in-Charge. |
| 59 | Material & labour for replacement of GI column pipe 50 mm bore medium grade, 3 Mtrs in length , both end flanged, including nuts bolts, washer and rubber gaskets etc complete all as speicfied all as specified and directed by Engineer-in-Charge. |
| 60 | Material & labour for replacement of GI column pipe 80 mm bore medium grade, 3 Mtrs in length , both end flanged, including nuts bolts, washer and rubber gaskets etc complete all as speicfied all as specified and directed by Engineer-in-Charge. |
| 61 | Lifting/lowering of unserviceable electric driven pumping set of capacity 5HP, discharge 3 LPS at head 60 meters alongwith GI column pipe 40/50 mm bore flanged at both side and submersible cable from bore for repair/rewinding the submersible pump set complete all as specified and directed by Engineer-in-Charge. |
| 62 | Lifting/lowering of unserviceable electric driven pumping set of capacity 17.5HP, discharge 5 LPS at head 80 to 120 meters alongwith GI column pipe 80 mm bore flanged at both side and submersible cable from bore for repair/rewinding the submersible pump set complete all as specified and directed by Engineer-in-Charge. |
| 63 | Opening of motor and taking out the burnt copper winding wire from submersible electric motor of capacity 5 HP and rewinding the submersible electric motor with super neamelled copper wire of existing gauge including testing and commissioning complete all as specified and directed by Engineer -in-Charge. |
| 64 | Opening of motor and taking out the burnt copper winding wire from submersible electric motor of capacity 7.5 HP and rewinding the submersible electric motor with super neamelled copper wire of existing gauge including testing and commissioning complete all as specified and directed by Engineer -in-Charge. |
| 65 | Supply and fix in replacement PVC insulated and sheathed multi strandard 3 core 10 sqmm flat 1100 volts grade electric copper submersible cable complet all as specied and directed by Engineer-in-Charge. |
| 66 | All as per item No.64 here-in-above but of size 3 core 6 sqmm complete all as specified and directed. |
| 67 | M&L for replacement of star coupling with rubber of centrifugal pump set having capacity 20 to 30 HP complete all as specified and directed. |
| 68 | S&F in replacement of fully star delta starter, oil immersed 414 Volts , 3 phase 50 HZ suitable for 50HP centrifugal pump set 01 No, complete all as specified and directed by Engineer-in-charge. |
| 69 | S&F in replacement star delta stater 3 phase 415 V suitable for 5 to 17.5 HP submersible pump set complete all as specified and directed. |
| 70 | Construction of stone masonary valve pit chamber of size 90cm x 90cm x 160 cm (internal dimension) including all necessary excavation and earth work in hard/dense soil and disposal of surplus soil to a distance not exceeding 50 meters as directed including PCC in foundation of the mixture (1:4:8) type D-2 stone masonary in cement mortor 1:4 rendering 15 mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externaly as the work proceeds in the same mortar as of stone masonary including MS frame (made out of angle in 40x40x6mm) and MS steel cover 3.15 mm thick with handle and locking arrangement with hinges angle iron flat as required at site complete all as specified and directed. |
| 71 | Cleaning of under ground sump, semi under ground sump of capacity 10000 to 50000gallons (Drinking water sump) after bailling out of water from tank & cleaning of all sides of wall , top, bottom with fresh water, with the help of pressure jet pump ( Maxium pressure up to 120 bar ) and vacuum suctioner pump, spray of chemical for anti fungal approved by WHO on all sides of walls after cleaning and applying two coats of white wash on external surfaces and writing date of cleaning on the tank complete all as directed by Engineer - in -charge . |
| 72 | S&F in replacement of foot valve 50/80mm bore cast iron flange / screwed with gasket complete all as specified and as directed. |
| 73 | S&F in replacement of foot valve 100 mm bore cast iron flange / screwed with gasket complete all as specified and as directed. |
| 74 | Supply, Laying, jointing, testing and in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated, armoured with multi-stranded aluminium conductor cable, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete of size 3.5 core 95 Sqmm all as specified and directed. |
| 75 | All as per Item ser No.73 above but size 3.5 core 70 sqmm complete all as specified and directed. |
| 76 | All as per Item ser No.73 above but size 3.5 core 50 sqmm complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender