Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #57589769

Tender For Repair/Maint Of Lt Overhead Conductor, Underground Cable, Lt Panel And Allied Accessories And Repair/Replacement Of External Security Lights/Fixtures And Connected Wks In Aor Of Kg Under Ge 881 Ews

Issued by Statutory Bodies & Commissions/Committees · Poonch, Jammu and Kashmir
Tender Value
48.50 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
23 days left
EMD
97000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Lt Overhead Conductor, Underground Cable, Lt Panel And Allied Accessories And Repair/Replacement Of External Security Lights/Fixtures And Connected Wks In Aor Of Kg Under Ge 881 Ews

BOQ

Name of Work:- REPAIR/MAINT OF LT OVERHEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES AND REPAIR/REPLACEMENT OF EXTERNAL SECURITY LIGHTS/FIXTURES AND CONNECTED WKS IN AOR OF KG UNDER GE 881 EWS
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: REPAIR/MAINT OF LT OVERHEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES AND REPAIR/REPLACEMENT OF EXTERNAL SECURITY LIGHTS/FIXTURES AND CONNECTED WKS IN AOR OF KG UNDER GE 881 EWS Contract No : GE/PNH-65/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed.
3Excavation in trenches not exc. 1.5 m wide and depth exc. 1.5 m but n. exc 3 mt for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed.
4Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed
5Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed.
6Supply and laying dry sand river for cushioning with layers of sand 8 cm before laying of cable and 15 cm after laying of cable in trenchesincluding punning of sand complete all as specified & directed. ( Note: Thickness after punning shall be measured and paid )
7Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
8Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 185 Sq mm including taking down old unserviceable cable complete all as specified and directed .
9All as per ser item N0-07, but Sec . area 150 Sqmm 3.5 core complete all as specified and directed.
10All as per ser item N0-07, but Sec . area 120 Sqmm 3.5 core complete all as specified and directed.
11All as per ser item N0-07, but Sec . area 95 Sqmm 3.5 core complete all as specified and directed.
12All as per ser item N0-07, but Sec . area 70 Sqmm 3.5 core complete all as specified and directed.
13All as per ser item N0-07, but Sec . area 50 Sqmm 3.5 core complete all as specified and directed.
14All as per ser item N0-07, but Sec . area 35 Sqmm 3.5 core complete all as specified and directed.
15All as per ser item N0-07, but Sec . area 25 Sqmm 4 core complete all as specified and directed.
16All as per ser item N0-07, but Sec . area 16 Sqmm 4 core complete all as specified and directed.
17All as per ser item N0-07, but Sec . area 16 Sqmm 2 core complete all as specified and directed.
18All as per ser item N0-07, but Sec . area 10 Sqmm 4 core complete all as specified and directed.
19All as per ser item N0-07, but Sec . area 10 Sqmm 2 core complete all as specified and directed.
20Taking down existing unserviceable PCC electric pole and Supplying, install and errect in true vertical position steel tubular swaged welded pole, 9.0 meter long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW M.S. tubing including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height complete all as specified and directed by Engr-in-charge. Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
21Dismantling Cross arms, bracings, supports, clamps complete all as specified and directed.
22Cross arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed including preparation of surface and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on steel surfaces complete all as specified and directed.
23Supply and fix in replacement Pin type insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade complete all as specified and directed.
24Supply and fix in replacement Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts,100 mm high and 115 mm dia with tension clamps for conductor working pressure 1100 volts complete all as specified and directed.
25Stay assembly complete with accessories i.e stay plate 300mm x 300mm x 6mm, galvanized thimbles, G.I. stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No.1 of MES Schedule Part-I complete all as specified and directed. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid for separately.
26Supply and fix in replacement Loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, Complete all as specified and directed.
27Cradles, hexagonal/rect angular , fabricated with galvanised steel wire 3.15 or 4 mm dia complete all as specified and directed.
28Dismantling of ACSR conductors and removing from the site complete all as specified and directed.
29Aluminium Conductor, Steel reinforced (ACSR)(weasel) of adequate size as in overhead conductors including fixing aluminium tapes for binding complete all as specified and directed. Note:- The weight of the conductor shall be determined as stipulated in Preamble (b) on page 384 of SSR-2010 Part II.
30Trimming tree branches coming in proximity to LT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches atleast 2.5 Mtrs apart from ACSR conductor from all sides all as directed. (Contactor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6\\" dia at his own arrangement and cost ).
31Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. ( Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge) Note:- Five lines together will be measured as one span from pole to pole.
32Supply,install, testing and commissioning in replacement of Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600mmx600mmx 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt alternate layers15cm thick at allround the earth plate, watering pipe 15mm bore medium grade galvanized iron with funnel and mesh and 40mm bore GI pipe light grade for protection of GI strip complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009.Note: GI strip upto 7.5 mtr deemed to be included in this item .
33Supply,install, testing and commissioning in replacement of Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600mmx600mmx 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron earth wire 4.00 mm dia with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt alternate layers15cm thick at allround the earth plate, watering pipe 15mm bore medium grade galvanized iron with funnel and mesh and 20mm bore GI pipe light grade for protection of GI strip complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009.Note: GI earth wire upto 7.5 mtr deemed to be included in this item .
34Supply and fix in replacement single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
35Supply and fix in replacement Test point terminal block made of gun metal or phosphorous bronze 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain MS sheet and screwed to GI pipe/ wall for protection of test point completed all as specified.
36Supply and fix in replacement GI tubing medium grade ISI Marked with all fitting for lighting conductor 50mm bore, fixed to wall/in roof with and including suitable clamps and bolts with nuts etc or embbeded in PCC blocks complete all as specified and directed.
37Supply and fix in replacement aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified and directed.
38Supply and fix in replacement galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe complete all as specified and directed. NOTE : Excavation & earth work shall be measured and paid for seperately under relevant item of schedule.
39Supply and Replacement in repair of GI tubing light grade with all fitting for protection of cable at road crossing 40mm dia complete all as specified and directed
40Supply and fix in replacement GI tubing light grade with all fitting for protection of cable at road crossing 80 mm bore complete all as specified and directed.
41Supply and fix in replacement MCCB 4 pole 63 Amps 415 volts with breaking capacity 16 KA. Ics=75% Icu complete all as specified and directed.
42Supply and fix in replacement MCCB 4 pole 160 Amps 415 volts with breaking capacity 36 KA. Ics=100% Icu complete all as specified and directed.
43Supply and fix in replacement MCCB 4 pole 200 Amps 415 volts with breaking capacity 36 KA. Ics=100% Icu complete all as specified and directed.
44Supply and fix in replacement MCCB 4 pole 250 Amps 415 volts with breaking capacity 36 KA. Ics=100% Icu complete all as specified and directed.
45Supply and fix in replacement MCCB 4 pole 400 Amps 415 volts with breaking capacity 36 KA. Ics=100% Icu complete all as specified and directed.
46Supply and fix in replacement thimble aluminium 185 sqmm suitable for LT XLPE cable complete all as specified and directed.
47Supply and fix in replacement thimble aluminium 120 sqmm suitable for LT XLPE cable complete all as specified and directed.
48Supply and fix in replacement thimble aluminium 95 sqmm suitable for LT XLPE cable complete all as specified and directed.
49Supply and fix in replacement thimble aluminium 70 sqmm suitable for LT XLPE cable complete all as specified and directed.
50Supply and fix in replacement thimble aluminium 50 sqmm suitable for LT XLPE cable complete all as specified and directed.
51Supply and fix in replacement thimble aluminium 35 sqmm suitable for LT XLPE cable complete all as specified and directed.
52Supply and fix in replacement thimble aluminium 25 sqmm suitable for LT XLPE cable complete all as specified and directed.
53PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
54PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
55PCC 1:2:4, Type B-1 using 20 mm graded aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed at site.
56Rubber insulating mat of size 2mx1mx 2.5mm complete ISI marked Complete all as specified and directed.
57Energy efficient LED street light fittings, 45 Watt, 230 volt AC out door type with high pressure die-cast aluminium housing and heat resistant complete with dirver, lamp bracket with impact and corrosion resistant including thermal management in multiple optic complete with IP66 protection, with inbuilt surge protection device including taking down old unserviceable light fittings any type complete all as specified and as directed.
58All as per item No. 56 above but for 60 Watt complete all as specified and directed by Engr-in-Charge.
59All as per item No. 56 above but for 75 Watt complete all as specified and directed by Engr-in-Charge.
60All as per item No. 56 above but for 90 Watt complete all as specified and directed by Engr-in-Charge.
61All as per item No. 56 above but for 35 Watt complete all as specified and directed by Engr-in-Charge.
62All as per item No. 56 above but for 100 Watt complete all as specified and directed by Engr-in-Charge.
63Supply and fix in replacement PVC spiral line spacer for LT OH line on 9.0 mtrs pole suitable for 2/3/4 wire all as specified and directed by Engr-in-charge.
641100 Volts grade heavy duty cable PVC insulated aluminum solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 10 Sqmm complete all as specified and directed.
65Supply and fix in replacement including testing and commissioning LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with Aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltemeter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including PCC work, 0.6 Mtr above ground level grouting etc and includes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etc, bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron and providing with following accessories:-INCOMMERa) MCCB TPN 36 KA, 200 Amps- 1 Nos(I/C) OUT GOINGb) MCCB TPN 25 KA,100 Amps - 01 Nosc) MCCB TPN 16 KA, 63 Amps - 03 Nosd) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & 300 Amps for neutral -1 No(e) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-300 Amps.(f) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No 0-500 V.(g) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder.(h) On Load Changeover Switch 415 Volts, 200 Amp 4 pole -01 No.
66Supply and fix in replacement LT over head lines on existing poles with XLPE insulated AB Cable 3-Core x 70 Sqmm+1 Core x 50 sqmm including all jointing kits, nut, bolts etc complete all as specified and directed.
67Taking down old unsv street light fittings any type from pole / wall / other similar situation and refixing, re-connecting the same in existing position after carrying out necessary repair / replacement of unsv accessories to make the fittings functional, complete all as speecified and directed.Note:- Accessories required to make the fittings functional shall be measured & paid seperately as supply only under relevent items.
68Supply only the following accessories to be incorporated for repair of street light fittings taken out under item No-66 above :-
69Supply only LED driver for street light fittings of upto 35 watt capacity.
70Supply only LED driver for street light fittings of 60 Watt capacity.
71Supply only LED driver for street light fittings of 70 watt capacity.
72Supply only LED driver for street light fittings of 90 watt capacity.
73Supply only glass cover for street light fittings upto 120 watt capacity.
74Thermo plastic street light weather proof out door type junction box of size 200mmx 160mm x 98mm complete with 4 way connector-01 No, 6 Amps SP MCB-01 No, easy openable and having locking arrangement including incoming and out going cable holes with fixing MS clamp and water tight polymide cable gland for each connection with & including taking down old unsv junction box, complete all as specified and directed.
75Supply, laying, testing and commissioning in trenches or passing through pipe 1100 volts grade armoured, heavy duty XLPE electric cable with aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed.
76All as per Item No 74 here-in-before but 16 Sqmm 4 core complete all as specified and directed.
77All as per Item No 74 here-in-before but 10 Sqmm 2 core complete all as specified and directed.
7840mm bore galvanised steel water tubing, light grade including all fittings laid in trenches / fixed to pole / along wall / floor etc for protection of cable/strip including fixing to pole with M.S. clamp, nuts, bolts etc complete all as specified and as directed.
79S&F in repair rigid non metallic PVC conduit pipes 20 mm dia and fixed with the pole by clamping / saddling for protection of connecting wires, connection from junction box to light fittings, complete all as specified and as directed incl taking down old unserviceable conduit complete all as specified and as directed.
80S&F street light bracket made out of GI tubing 40mm bore, medium grade, 1.2 metre long bent to shape as directed, including suitable MS clamp of MS Flat with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete including taking down u/s bracket any type all as specified and as directed.
81Supply and Replacement in repair of copper strip 20 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified.
82Supply ,laying and fixing DWC HDPE pipe for protection of power cable (orange in colour) of size 50 mm dia complete with fittings and including cutting , jointing and clamping all as specified and directed .
83MCBs SP 5 to 32 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
84Bus bar chamber of size 600x600x450mm suitable for 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 100A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type B1 (using 20mm graded stone aggregates) alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57589769
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.50 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Lt Overhead Conductor, Underground Cable, Lt Panel And Allied Accessories And Repair/Replacement Of External Security Lights/Fixtures And Connected Wks In Aor Of Kg Under Ge 881 Ews
Basic Detail
Tender No GE/PNH-65/2026-27
Bidding Type Tender
Location
City Poonch
State Jammu and Kashmir
Key Dates
Publish Date 18 Sep 2026
Submission Date 12 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 48.50 Lakhs
Tender Fee 500
EMD 97000
Exemption Available
Document List
95562605-cba4-4c93-9bbc-0a9d2a5622a6.html
BOQ_885596.xls
TENDER.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.