Tender For The Widening Of Perimeter Road, The Road Hardstanding Of Fire Lanes Around Perimeter Road & Hill Slope Road At 1St Road Of Magazone, Water Sprinkler Swt 50K Litre Under Ge (I) R&D Pashan, Pune
Tender Value
15 Crore
Estimated cost
Bid Submission
23 Oct 2026
19 days left
EMD
10.75 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for The Widening Of Perimeter Road, The Road Hardstanding Of Fire Lanes Around Perimeter Road & Hill Slope Road At 1St Road Of Magazone, Water Sprinkler Swt 50K Litre Under Ge (I) R&D Pashan, Pune
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part - IBUILDINGS & STRUCTURESLump sum price worked out by the contractor for BUILDINGS & STRUCTURES as listed in Schedule A PART-1.NOTE: This schedule is not pre-priced by MES and the rate indicated as ₹0.00 under column 5 signifies this fact only. The tenderer is required to quote the rate under column 6 against item of works catered under the schedule. |
| 2 | Construction of block of FIRE PUMP HOUSE BLDG including all fittings and fixtures, complete all as shown on drawings and as per specifications. |
| 3 | Construction of STATIC WATER TANK 50K (SWT) including all fittings and fixtures, complete all as shown on drawings and as per specifications. |
| 4 | Lump sum price worked out by the Contractor for “INTER WATER SUPPLY\\" as listed in Schedule ‘A’ Part - II representing __________ % ________________ percent Above / Below the lump sum price of `10,996.40 inserted by the MES in Schedule ‘A’ Part - II |
| 5 | Lump sum price worked out by the Contractor for “INTER ELECTRIC SUPPLY\\" as listed in Schedule ‘A’ Part - II representing __________ % ________________ percent Above / Below the lump sum price of `86,055.00 inserted by the MES in Schedule ‘A’ Part - III |
| 6 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV representing ________ % ____________ percent Above / Below the lump sum price of ₹53,499.40 inserted by the MES in Schedule ‘A’ Part - IV |
| 7 | Lump sum price worked out by the Contractor for “FIRE FIGHTING SYSTEM” as listed in Schedule ‘A’ Part - V representing ________ % ____________ percent Above / Below the lump sum price of ₹15,37,401.80 inserted by the MES in Schedule ‘A’ Part - V |
| 8 | Schedule 'A' Part-VIThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 7.00 to 55.00. |
| 9 | INTERNAL WATER SUPPLYProviding and fixing CPVC gate valve 20 mm nominal bore of approved quality complete all as speciied and directed. |
| 10 | S & F for chromium plated pillar cock auto closing system complete all as speciied and directed. |
| 11 | INTERNAL ELECTRIC SUPPLYMaterial and Labour for point wiring complete with 2.5 sqmm PVC insulated and PVC unsheathed 1100V grade single core multistranded copper conductor cable, drawn through and including PVC concealed conduit with all necessary accessories, fixed on walls / floors / roofs, including sunken pressed steel terminal boxes suitable for fixing modular switches, sockets and regulators of any capacity with 3mm sunmica/plastic laminated sheet including provision of one continuous run of 2.5 sqmm PVC insulated green-coloured multistranded copper conductor as earth continuity conductor connecting to the common earth dolly for one indepndent 15 Amps, 3 pin socket outlet complete all as specified and directed. |
| 12 | Supplying and fixing 40 A SPN rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of in the existing MCB DB complete with connections, testing and commissioning etc. complete all as speciied and directed. Please Enable Macros to View BoQ information |
| 13 | Supplying and fixing 40 A SPN rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of in the existing MCB DB complete with connections, testing and commissioning etc. complete all as speciied and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender