Tender For Repair / Maintenance Of Pao (Or) annual maintenance contract Centre & College Under Ge (East) Lucknow
Tender Value
8 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
5 days left
EMD
16000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Pao (Or) annual maintenance contract Centre & College Under Ge (East) Lucknow
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed. |
| 2 | Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal modular box and modular sheet and cover plate ,screws etc and making good to the disturbed surfaces to match the existing complete all as specified and directed. |
| 3 | All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp complete all as specified and directed. |
| 4 | All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp complete all as specified and directed. |
| 5 | All as per Serial Item No 02 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 6 | S&F modular one-way switch, 6 Amp, 1-module size of approved make, with all necessary fixing accessories and electrical connections complete all as specified and directed. |
| 7 | S&F modular one-way switch, 16 Amp, 1-module size, of approved make, with all necessary fixing accessories and electrical connections complete all as specified and directed. |
| 8 | S&F modular socket outlet, 6 Amp, 2/3 pin combined, 2-module size, of approved make with all necessary fixing accessories and electrical connections complete all as specified and directed. |
| 9 | S&F modular socket outlet, 6/16 Amp, 2/3 pin combined, 2-module size, of approved make with all necessary fixing accessories and electrical connections complete all as specified and directed. |
| 10 | S&F MCCB, four-pole, 125 Amp, with CGI Sheet enclosure minimum breaking capacity 16 kA (Icu = Ics), thermally adjustable type with thermal overload setting range from 70% to 100% of rated current, and fixed magnetic short-circuit protection, with spreader links (set of four) for cable connections, suitable cable lugs, nuts, bolts and washers including making all electrical connections complete all as specified and directed. |
| 11 | Supply and fix in replacement LED tube light fittings 1200 mm, 22 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminium housing without powder coating enviromental friendly, energy efficient complete all as specified and directed. |
| 12 | Supply and fix in replacement LED tube light fittings 600 mm,10/12W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded PVC poycarmo housing enviromental friendly, energy efficient complete all as specified and directed. |
| 13 | Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed. |
| 14 | Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed. |
| 15 | Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed. |
| 16 | Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, \\"C\\" curve, 10 KA breaking capacity - 12 Nos. |
| 17 | Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 18 | Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 32 Amp capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 19 | Supply and fix in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 20 | S & F in replacement of unserviceable wire of size 1.5 Sqmm with PVC insulated FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 1.5 Sqmm complete all as specified and directed. |
| 21 | S & F in replacement of unserviceable wire of size 2.5 Sqmm with PVC insulated FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 1.5 Sqmm complete all as specified and directed. |
| 22 | Supply and fix in replacement of recessed mounted 2'x2' LED ceiling light fitting 36 watt, 6500K, with IP 20 protection comprises of CRCA housing, high efficiency diffuser cover, electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and directed. |
| 23 | Repair and maint supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 24 | Repair and maint supply and fixing wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/min with all accessories complete all as specified and directed. |
| 25 | Repair and maint supply and fix exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM ISI marked, and making connection with twisted copper flexibel wire 23/0.076 mm complete all as specified and directed. |
| 26 | S & F steel tubelar swaged poles complete with cast iron base plate, finial tapper plug, bolts, nuts & screws for fixing as specified type 410 SP-22 ( 8.50 meters long) complete all as specified and directed. |
| 27 | Supply, install, test and commissioning in replacement factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of min size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Aluminium bus bar and MCB SP 6Amp-01 No complete all as specified and directed. |
| 28 | M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric poles, struts PCC blocks including necessary form work and fair finish to exposed surfaces without using extra cement etc, complete all as specified and directed. |
| 29 | M & L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in the foundation of electric poles,stay assembly and struts PCC blocks including necessary form work and fair finish to exposed surfaces without using extra cement etc, complete all as specified and directed. |
| 30 | All as per Item No- 29 here-in-before but PCC (1:2:4) type B-1 using 20mm graded stone aggregate for coping of poles complete all as specified and directed. |
| 31 | Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed. |
| 32 | Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed. |
| 33 | Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed & complete all as specified and directed. |
| 34 | Supplying and laying bricks common brunt clay, building bricks sub class -B, Designation 75 for laying of cable protection including removing of old bricks complete all as specified and directed. |
| 35 | Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete.Note:- 18 cm punned down thickness shall be considerd for mesurement complete all as specified and directed. |
| 36 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed. |
| 37 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed. |
| 38 | Supply and fix LED Street light fiiting 100 watt,230V AC outdoor type , IP 65, made up of pressure die cast aluminium housing with potted Isolated driver and high power LED and individual lenses including with suitable angle iron bracket , nut and bolts for fixing complete all as specified and directed. |
| 39 | S & F Change over switch 3 phase , 160 Amp , 415 Volt on load type with enclosure complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender