Drinking Water Supply and Sanitation Government Departments Closing in 1 days TDR #57588665

Tender For Yamuna Nagar Town , Supply, Installation, Testing And Commissioning Of Electromagnetic Flow Meters, Do Sensors, Level Sensors, Dataloggers, Scada System With Cloud Dashboard, Networking And Electrical Works , Including Civil, Electrical An

Issued by Government Departments · Yamunanagar, Haryana
Tender Value
54.12 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
1 days left
EMD
1.08 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Yamunanagar → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Yamuna Nagar Town , Supply, Installation, Testing And Commissioning Of Electromagnetic Flow Meters, Do Sensors, Level Sensors, Dataloggers, Scada System With Cloud Dashboard, Networking And Electrical Works , Including Civil, Electrical And Associated Scada Works.At 20 Mld Stp Radaur Road Yamuna Nagar, Block Jagadhri, Constituency Yamuna Nagar District Yamuna Nagar. (Jha Under Amrut 2.0). Replacement Of Pumping Machinery, Design,Supply, Installation And Testing Of Vfd Along With Distribution Panel, Allied Civil Work And Fixing Of Outfall Delivery And All Other Works Contingent Thereto.

BOQ

Name of Work:- Yamuna Nagar Town , Supply, Installation, Testing and Commissioning of Electromagnetic Flow Meters, DO Sensors, Level Sensors, Dataloggers, SCADA System with Cloud Dashboard, Networking and Electrical Works , including Civil, Electrical and Associated SCADA Works.at 20 MLD STP Radaur Road Yamuna Nagar, Block Jagadhri, Constituency Yamuna Nagar District Yamuna Nagar. (JHA under AMRUT 2.0).` Replacement of Pumping Machinery, Design,Supply, Installation and testing of VFD along with distribution panel, allied civil work and fixing of outfall delivery and all other works contingent thereto.`
Sl. No. Item Description
1Sub Head No.2 N.S.Items
2Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 65HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For non clog submersible Pump)
3Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 15 m as per the indicated requirements of discharge in 11458 LPM and power capacity in 65 BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect.@@
4Supplying, erection, testing and commissioning of Horizontal motor pumping set non clog for sewerage having head 15 m as per the indicated requirements of discharge in 14000 LPM and power capacity in 80 BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect. ##
5Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having 60 HP as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked includingall accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect (Discharge Capacity - Power Capacity (BHP) -100 HP At Shadipur IPS
6Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 100 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For non clog submersible Pump)
7Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 80 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Horizontal non clog Pump) (80 HP)**
8Sub Head No. I HSR Items (Civil Works)
9Replacement of Pumping Machinery, Design,Supply, Installation and testing of VFD along with distribution panel, allied civil work and fixing of outfall delivery and all other works contingent thereto.` Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57588665
AUTHORITY Government Departments
TENDER VALUE 54.12 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Yamuna Nagar Town , Supply, Installation, Testing And Commissioning Of Electromagnetic Flow Meters, Do Sensors, Level Sensors, Dataloggers, Scada System With Cloud Dashboard, Networking And Electrical Works , Including Civil, Electrical And Associated Scada Works.At 20 Mld Stp Radaur Road Yamuna Nagar, Block Jagadhri, Constituency Yamuna Nagar District Yamuna Nagar. (Jha Under Amrut 2.0). Replacement Of Pumping Machinery, Design,Supply, Installation And Testing Of Vfd Along With Distribution Panel, Allied Civil Work And Fixing Of Outfall Delivery And All Other Works Contingent Thereto.
Basic Detail
Tender No 2026396701E3 915A 4D59 B45F 4BB5B7C37994548PUH
Bidding Type Tender
Location
City Yamunanagar
State Haryana
Key Dates
Publish Date 18 Sep 2026
Submission Date 30 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 54.12 Lakhs
Tender Fee 5000
EMD 1.08 Lakhs
Exemption Available
Document List
3ff1a377-49ba-4976-b8b8-c718ef1d835b.html
779284Z165701.pdf
BOQ_628556.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

3ff1a377-49ba-4976-b8b8-c718ef1d835b.html

pdf

779284Z165701.pdf

xls

BOQ_628556.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders