Tender For B.O.Q For Development Of Shrine Premises And Bada Talab At Charisharief B.W.O Development Of Shrine Premises At Charrarishareif By Way Of Ornamental Canopy And Installation Of Led Luminaries With Allied Accessories Like Wiring Controlling/
Tender Overview
Project Description
Tender for B.O.Q For Development Of Shrine Premises And Bada Talab At Charisharief B.W.O Development Of Shrine Premises At Charrarishareif By Way Of Ornamental Canopy And Installation Of Led Luminaries With Allied Accessories Like Wiring Controlling/ Protection Switch Gear Devices Etc (Electric Part Only)
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing of 10-12 Watts LED recessed (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminium. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & DriverApproved make Philips / Lighting techology / Trilux /Regent /Endo (to be approved before installation) |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfacel recessed medium class PVC conduit as required.of Salzar /Polycab /Finolex /RR Kabels make |
| 3 | 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire |
| 4 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) of Legrend /L&T /ABB /Simens /Schinder make |
| 5 | 16 way, Double door |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /L&T /Simens / eq. make to be approved by EIC |
| 7 | Supplying and fixing of 63 Amps rating DP 240/415 volts c cURVE (10KA) of Legrend /L&T /ABB /Simensmake dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make |
| 8 | earthing with GI rod of 6 ft long perforated type to be embedded in a pit with extending of earthing from rod to pole by way of p/l of 8 No SWG insulated bare GI Wire strip from electrode to deice |
| 9 | Supply and laying of 40 mm dia HPPE flexible Pipe (air Cusion type heavy duty ) for laying of Cables in cable trench. |
| 10 | Supply, Laying, Testing and Commissioning of XLPE insulated PVC inner sheathed steel armoured Al Cable of Havells /Grandlays /Polycab make incl making of necessary connections with proper size of Al Thimbles dully crimped with crimping tool |
| 11 | 10 sq mm 2- Core |
| 12 | earthing with GI rod of 6 ft long perforated type to be embedded in a pit with extending of earthing from rod to pole by way of p/l of 8 No SWG insulated bare GI Wire strip from electrode to deice |
| 13 | Supply and laying of 40 mm dia HPPE flexible Pipe (air Cusion type heavy duty ) for laying of Cables in cable trench. |
| 14 | Supply/ installation/testing and commissioning of Outdoor type Wall / floor mounted compartmentalized Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel , provided and fitted with 100- 200 P&N Colour Coded Bus Bar (As per instructions of EIC) and should be provided with indicators ,Voltmeter ,ammeter ,CT Coils etc .The Panel should have spacing for accomadating of 63-100 Amps TPN MCCB /MCB (Excluding cost of MCCB/MCB) but including cost of Bus Bar ,indication and metering devices. The Panel Should also have Spacing of outgoing MCB's equivalent to 12 Way DB Box (To be fabricated as per instructions of EIC Before submitting of SDL) The above mentioned quantities are for one panel and in total three (3 No) panels indual panels are to be fabricated having 1 No's of 3 ft x 2 ft x 1 ft =6 sftThe job includes providing and fixing of angle iron stand ahving minimum height 2.5 ft with four no of angle iron legs to be grouted in cement concrete upto 1 ft complte job including cost concreting 1:3:6 |
| 15 | Supplying and fixing 100 rating, 240/415 V, 10 kA, \\"C\\" curve DP MCB , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required. Of Legrend /L&T/ ABB / Scheinder make |
| 16 | Supply ,installation ,Testing and Commissioning of 63-100 Amps 4-pole Connector Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender