Civil Aviation Boards / Undertakings / PSU Closing in 13 days TDR #57584650

Bids Are invited for Annual Operation And Maintenance For The E And M Installation At Bhuj Airport

Issued by Boards / Undertakings / PSU · Kachchh, Gujarat
Tender Value
1.48 Crore
Estimated cost
Bid Submission
09 Oct 2026
13 days left
EMD
4.44 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Not Available
Quantity
200404

Project Description

Bids Are invited for Annual Operation And Maintenance Of Electrical And Mechanical Installations Manpower - Annual Operation And Maintenance Of Electrical And Mechanical Installations, Power House Installations Including Ht Panels, Transformers, Terminal Building, Dg Sets, Bhs System, Operational Area Or Apron, City Side Car Parking Area, Aai Residential Colony, Cisf Barrack, Rooftop Solar Plant, Water Supply Pumps In Three Shifts On All Working Days As Per Specification And Condition Attached, Attending To Complaints Or Faults Or Breakdowns, Ensuring Serviceability And Satisfactory Working Condition Of The System, Performing Preventive Maintenance, Maintenance Of Records Or Documentation Etc. As Per The Detailed Specifications, Terms And Conditions Covered Under This Contract, On All Days Including Sundays And Holidays And Also As And When Required Basis. Highly Skilled 2, Skilled 7, Semi Skilled 6, Un Skilled 5. , Inspection, Servicing And Testing Of 3 Ph 11Kv 400A Ht Vaccum Circuit Breaker Vcb - Inspection, Servicing And Testing Of 3 Ph 11Kv 400A Ht Vaccum Circuit Breaker Vcb Panel Make Crompton Greaves, Model 12V X 12 Xl As Per Recommended Standards Of Oem And As Specified In The Scc Including Testing Of Connected Cts And Pts, Wiring Wherever As Required, Minor Repairing Works And Replacement Of Defective Parts Or Spares Documenting The Testing, Submitting The Same To Aai Etc Compelete As Required. The Above Activity Shall Be Carried Out Through Oem Or Authorized Service Dealer Of Oem Etc. Complete As Required. 3 Nos. Vcbs X 2 Year Equalto 6 Job , Servicing, Testing, Checking And Replacement Of Defective Parts Or Spares Of 500 Kva, 11 Kv Or 433 Kv Crompton Make Onan Cooled Transformer - Servicing, Testing, Checking And Replacement Of Defective Parts Or Spares Of 500 Kva, 11 Kv Or 433 Kv Crompton Make Onan Cooled Transformer Including Testing Of Wiring, Minor Repairing Works As Per Recommended Standard And Submission Of Report Complete As Required Through Authorised Service Agency Of Oem Or Agency Approved By Engineer In Charge. Testing Should Include Insulation Resistance Test, Voltage Ratio And Tap Continuity Test, Magnetic Balance Test, Vector Group Test, Accessories Working Etc. As Required.Note If Required, Spares Of Transformer Shall Be Arrange By Agency For The Replacement Of The Defective Components Or Spares Aai Shall Paid Extra For The Same. 2 Nos. X 2 Year Equalto 4 Job , Servicing, Checking And Testing Of The Lt Air Circuit Breakers Up To 800 Rating - Servicing, Checking And Testing Of The Lt Air Circuit Breakers Up To 800 Rating Including Testing Of Wiring Of Breaker And Minor Repairing Works Complete As Required Including Documenting The Testing As Per Recommended Standards And As Mentined In The Scc Through Oem Or Authorised Agency Of Oem Followed With Submission Of Test Report To Aai. Make L And T, Model Cn Cs 800 S. 8 Nos. X 2 Years Equalto 16 Job

BOQ

Sl. No. Item TitleItem Description
1Annual operation and Maintenance of Electrical and Mechanical Installations ManpowerAnnual operation and Maintenance of Electrical and Mechanical Installations, power house installations including HT panels, transformers, terminal building, DG Sets, BHS system, operational area or apron, city side car parking area, AAI residential colony, CISF barrack, rooftop solar plant, water supply Pumps in three shifts on all working days as per specification and condition attached, attending to complaints or faults or breakdowns, ensuring serviceability and satisfactory working condition of the system, performing preventive maintenance, maintenance of records or documentation etc. as per the detailed specifications, terms and conditions covered under this contract, on all days including Sundays and holidays and also as and when required basis. Highly Skilled 2, Skilled 7, Semi skilled 6, Un Skilled 5.
2Inspection, Servicing and testing of 3 Ph 11KV 400A HT Vaccum Circuit Breaker VCBInspection, Servicing and testing of 3 Ph 11KV 400A HT Vaccum Circuit Breaker VCB Panel Make Crompton Greaves, Model 12V X 12 XL as per recommended standards of OEM and as specified in the SCC including testing of connected CTs and PTs, Wiring wherever as required, minor repairing works and replacement of defective parts or spares documenting the testing, submitting the same to AAI etc compelete as required. The above activity shall be carried out through OEM or authorized service dealer of OEM etc. complete as required. 3 nos. VCBs x 2 year equalto 6 Job
3Servicing, Testing, checking and replacement of defective parts or spares of 500 kVA, 11 KV or 433 kV Crompton make ONAN cooled TransformerServicing, Testing, checking and replacement of defective parts or spares of 500 kVA, 11 KV or 433 kV Crompton make ONAN cooled Transformer including testing of wiring, minor repairing works as per recommended standard and submission of report complete as required through authorised service agency of OEM or agency approved by engineer in charge. Testing should include Insulation Resistance test, Voltage Ratio and Tap Continuity test, Magnetic Balance Test, Vector Group Test, Accessories working etc. as required.NOTE If required, spares of transformer shall be arrange by agency for the replacement of the defective components or spares AAI shall paid extra for the same. 2 Nos. x 2 year equalto 4 Job
4Servicing, Checking and Testing of the LT air circuit breakers up to 800 Amp ratingServicing, Checking and Testing of the LT air circuit breakers up to 800 Amp rating including testing of wiring of breaker and minor repairing works complete as required including documenting the testing as per recommended standards and as mentined in the SCC through OEM or authorised agency of OEM followed with submission of test report to AAI. Make L and T, Model CN CS 800 S. 8 nos. x 2 years equalto 16 JOB

AI Tender Summary

OUR REF NO 57584650
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.48 Crore
LAST DATE 09-10-2026
Authority
Authority Name Airports Authority Of India
Work Description Bids Are invited for Annual Operation And Maintenance Of Electrical And Mechanical Installations Manpower - Annual Operation And Maintenance Of Electrical And Mechanical Installations, Power House Installations Including Ht Panels, Transformers, Terminal Building, Dg Sets, Bhs System, Operational Area Or Apron, City Side Car Parking Area, Aai Residential Colony, Cisf Barrack, Rooftop Solar Plant, Water Supply Pumps In Three Shifts On All Working Days As Per Specification And Condition Attached, Attending To Complaints Or Faults Or Breakdowns, Ensuring Serviceability And Satisfactory Working Condition Of The System, Performing Preventive Maintenance, Maintenance Of Records Or Documentation Etc. As Per The Detailed Specifications, Terms And Conditions Covered Under This Contract, On All Days Including Sundays And Holidays And Also As And When Required Basis. Highly Skilled 2, Skilled 7, Semi Skilled 6, Un Skilled 5. , Inspection, Servicing And Testing Of 3 Ph 11Kv 400A Ht Vaccum Circuit Breaker Vcb - Inspection, Servicing And Testing Of 3 Ph 11Kv 400A Ht Vaccum Circuit Breaker Vcb Panel Make Crompton Greaves, Model 12V X 12 Xl As Per Recommended Standards Of Oem And As Specified In The Scc Including Testing Of Connected Cts And Pts, Wiring Wherever As Required, Minor Repairing Works And Replacement Of Defective Parts Or Spares Documenting The Testing, Submitting The Same To Aai Etc Compelete As Required. The Above Activity Shall Be Carried Out Through Oem Or Authorized Service Dealer Of Oem Etc. Complete As Required. 3 Nos. Vcbs X 2 Year Equalto 6 Job , Servicing, Testing, Checking And Replacement Of Defective Parts Or Spares Of 500 Kva, 11 Kv Or 433 Kv Crompton Make Onan Cooled Transformer - Servicing, Testing, Checking And Replacement Of Defective Parts Or Spares Of 500 Kva, 11 Kv Or 433 Kv Crompton Make Onan Cooled Transformer Including Testing Of Wiring, Minor Repairing Works As Per Recommended Standard And Submission Of Report Complete As Required Through Authorised Service Agency Of Oem Or Agency Approved By Engineer In Charge. Testing Should Include Insulation Resistance Test, Voltage Ratio And Tap Continuity Test, Magnetic Balance Test, Vector Group Test, Accessories Working Etc. As Required.Note If Required, Spares Of Transformer Shall Be Arrange By Agency For The Replacement Of The Defective Components Or Spares Aai Shall Paid Extra For The Same. 2 Nos. X 2 Year Equalto 4 Job , Servicing, Checking And Testing Of The Lt Air Circuit Breakers Up To 800 Rating - Servicing, Checking And Testing Of The Lt Air Circuit Breakers Up To 800 Rating Including Testing Of Wiring Of Breaker And Minor Repairing Works Complete As Required Including Documenting The Testing As Per Recommended Standards And As Mentined In The Scc Through Oem Or Authorised Agency Of Oem Followed With Submission Of Test Report To Aai. Make L And T, Model Cn Cs 800 S. 8 Nos. X 2 Years Equalto 16 Job
Basic Detail
Tender No GEM/2026/B/8055211
Bidding Type Tender
Location
City Kachchh
State Gujarat
Key Dates
Publish Date 18 Sep 2026
Submission Date 09 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 1.48 Crore
Tender Fee Ref. Documents
EMD 4.44 Lakhs
Exemption Not Available
Document List
211a012e-c56b-4d91-ae71-acc2719cf283.pdf
td_2026-09-18-16-46-54_fd67648ee39db101edf304f4519afe22.pdf
9914196_Boq_1.xlsx
TD_2f32fcf3-ffc2-4801-92091789731665502_bhuj_EE.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

211a012e-c56b-4d91-ae71-acc2719cf283.pdf

pdf

td_2026-09-18-16-46-54_fd67648ee39db101edf304f4519afe22.pdf

xlsx

9914196_Boq_1.xlsx

pdf

TD_2f32fcf3-ffc2-4801-92091789731665502_bhuj_EE.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders