Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation, Maintenance, Repairing And Re- Erection Work Of Damaged Lines/Poles Under Edsd, Banda- Rural Against
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation, Maintenance, Repairing And Re- Erection Work Of Damaged Lines/Poles Under Edsd, Banda- Rural Against Tender No Edcbnda-44/20.. - Safe Cartage Of 8.5 Mtr. Long Pcc Poles , Safe Cartage Of 11 Mtr. Long St Poles , Safe Cartage Of Line Material , Erection Of Newly Erected 8.5 Mtr. Long Pcc Poles As Single Support Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Erection Of Newly Erected 11 Mtr. Long St Poles As Single Pole Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Erection Of Newly Erected 8.5 Mtr. Long Pcc Poles As Double Pole Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Erection Of Newly Erected 11 Mtr. Long St Poles As Double Pole Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Concreting/Grouting Of Newly Erected 8.5 Mtr. Long Pcc Poles As Single Support/Double Pole Structures. The Support Shall Be Grouted With Cement, Sand And Brick Ballast/Stone Ballast In Ratio 1:4:8 (0.285 Cu. Mtr. Each), Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast/Stone Ballast, Stone Pad Etc. As Per Actual Site Requirement & Direction Of Enginner Incharge. , Concreting/Grouting Of Newly Erected 11 Mtr. Long St Poles As Single Support/Double Pole Structures. The Support Shall Be Grouted With Cement, Sand And Brick Ballast/Stone Ballast In Ratio 1:4:8 (0.285 Cu. Mtr. Each), Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast/Stone Ballast, Stone Pad Etc. As Per Actual Site Requirement & Direction Of Enginner Incharge. , Erection And Grouting Of Stay Set Including The Work Of Nozelling Etc. As Per Resspo Manual And Also Including The Cost Of All Grouting Material. , Fixing Of Earthing Rod As Per Direction Of Supervising Engineer/Resspo Manual. Including The Cost Of Labour, T&P Etc. Required For Proper Completion Of Work. , Laying, Sagging, Stringing, Binding And Jumpering Of New Acsr Weasel/Dog Conductor On The Erected Poles In 11 Kv Ht/Lt Lines Also Providing In-Place Of Damaged/Misplace Conductor Due To Heavy Storm. , Laying, Stringing, Binding And Termination Etc. Of Abc Cable Of Various Size On The Erected Poles As Per Direction Of Supervising Engineer/Resspo Manual. , Re-Sagging Of Loose Conductor Of 33 Kv Lines At Various Places. , Re-Sagging Of Loose Conductor Of 11 Kv Ht Lines At Various Places. , Re-Sagging Of Loose Conductor Of Lt Lines At Various Places. , Dismentling & Removal Of Existing/Erected Old & Damaged Pcc/Stp/Joist/Rail Poles As Single Pole Structure With Its Accessories. , Dismentling & Removal Of Existing/Erected Old & Damaged Pcc/Stp/Joist/Rail Poles As Double Pole Structure With Its Accessories. , Carriage Of Damaged/Rusted St/Rail/Joist Poles From Work Site To Esc. , Replacement Of Damaged/Misplace Pin Insulator With Pin 33 Kv/11 Kv , Replacement Of Damaged/Misplace V Type Cross Arm 33 Kv/11 Kv , Replacement Of Damaged/Misplace Disc Insulator With Fitting 33 Kv/11 Kv , Guarding With Fitting Of All Accessories As Per Resspo Manual. , Dismentling & Removal Of Damaged Weasel/Dog Conductor With Its Accessories Due To Heavy Storm And Also Cartage Of Old/Damaged & Scrap Line Material From Work Site To Store Centre/Je(S). , Straightening Of Tilted Single Support As 8.5/11.0 Mtr. Long Pcc/St Pole At Various Places. , Chopping Of Tree Branches Coming In The Vicinity Of The Lines During The Execution Of Above Work. , Fixing Of T-Off Channel With Fitting Of All Accessories As Per Resspo Manual. , Supply & Fixing Of Nut-Bolts With Warsher Of Suitable Sizes As Per Resspo Manual. , Note: Any Quantity Of Item From Sl No. 1 To Sl No. 28 May Vary To Any Limit Within The Financial Value Of Agreement Against This Tender.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Safe cartage of 8.5 Mtr. long PCC poles | Safe cartage of 8.5 Mtr. long PCC poles |
| 2 | Safe cartage of 11 Mtr. long ST poles | Safe cartage of 11 Mtr. long ST poles |
| 3 | Safe cartage of line material | Safe cartage of line material |
| 4 | Erection of newly erected 8.5 Mtr. long PCC poles as single support structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 8.5 Mtr. long PCC poles as single support structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 5 | Erection of newly erected 11 Mtr. long ST poles as single pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 11 Mtr. long ST poles as single pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 6 | Erection of newly erected 8.5 Mtr. long PCC poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 8.5 Mtr. long PCC poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 7 | Erection of newly erected 11 Mtr. long ST poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 11 Mtr. long ST poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 8 | Concreting/Grouting of newly erected 8.5 Mtr. long PCC poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. | Concreting/Grouting of newly erected 8.5 Mtr. long PCC poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. |
| 9 | Concreting/Grouting of newly erected 11 Mtr. long ST poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. | Concreting/Grouting of newly erected 11 Mtr. long ST poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. |
| 10 | Erection and grouting of stay set including the work of nozelling etc. as per RESSPO manual and also including the cost of all grouting material. | Erection and grouting of stay set including the work of nozelling etc. as per RESSPO manual and also including the cost of all grouting material. |
| 11 | Fixing of earthing rod as per direction of supervising engineer/RESSPO manual. including the cost of labour, T&P etc. required for proper completion of work. | Fixing of earthing rod as per direction of supervising engineer/RESSPO manual. including the cost of labour, T&P etc. required for proper completion of work. |
| 12 | Laying, sagging, stringing, binding and jumpering of new ACSR Weasel/Dog Conductor on the erected poles in 11 KV HT/LT lines also providing in-place of damaged/misplace conductor due to heavy storm. | Laying, sagging, stringing, binding and jumpering of new ACSR Weasel/Dog Conductor on the erected poles in 11 KV HT/LT lines also providing in-place of damaged/misplace conductor due to heavy storm. |
| 13 | Laying, stringing, binding and termination etc. of ABC Cable of various size on the erected poles as per direction of supervising engineer/RESSPO manual. | Laying, stringing, binding and termination etc. of ABC Cable of various size on the erected poles as per direction of supervising engineer/RESSPO manual. |
| 14 | Re-sagging of loose conductor of 33 KV lines at various places. | Re-sagging of loose conductor of 33 KV lines at various places. |
| 15 | Re-sagging of loose conductor of 11 KV HT lines at various places. | Re-sagging of loose conductor of 11 KV HT lines at various places. |
| 16 | Re-sagging of loose conductor of LT lines at various places. | Re-sagging of loose conductor of LT lines at various places. |
| 17 | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as single pole structure with its accessories. | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as single pole structure with its accessories. |
| 18 | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as double pole structure with its accessories. | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as double pole structure with its accessories. |
| 19 | Carriage of damaged/rusted ST/Rail/Joist Poles from work site to ESC. | Carriage of damaged/rusted ST/Rail/Joist Poles from work site to ESC. |
| 20 | Replacement of damaged/misplace pin insulator with pin 33 KV/11 KV | Replacement of damaged/misplace pin insulator with pin 33 KV/11 KV |
| 21 | Replacement of damaged/misplace \\"V\\" Type Cross Arm 33 KV/11 KV | Replacement of damaged/misplace \\"V\\" Type Cross Arm 33 KV/11 KV |
| 22 | Replacement of damaged/misplace disc insulator with fitting 33 KV/11 KV | Replacement of damaged/misplace disc insulator with fitting 33 KV/11 KV |
| 23 | Guarding with fitting of all accessories as per RESSPO manual. | Guarding with fitting of all accessories as per RESSPO manual. |
| 24 | Dismentling & removal of damaged weasel/dog conductor with its accessories due to heavy storm and also cartage of old/damaged & scrap line material from work site to store centre/JE(s). | Dismentling & removal of damaged weasel/dog conductor with its accessories due to heavy storm and also cartage of old/damaged & scrap line material from work site to store centre/JE(s). |
| 25 | Straightening of tilted single support as 8.5/11.0 Mtr. Long PCC/ST Pole at various places. | Straightening of tilted single support as 8.5/11.0 Mtr. Long PCC/ST Pole at various places. |
| 26 | Chopping of Tree Branches coming in the vicinity of the lines during the execution of above work. | Chopping of Tree Branches coming in the vicinity of the lines during the execution of above work. |
| 27 | Fixing of T-Off Channel with fitting of all accessories as per RESSPO manual. | Fixing of T-Off Channel with fitting of all accessories as per RESSPO manual. |
| 28 | Supply & Fixing of Nut-Bolts with warsher of suitable sizes as per RESSPO manual. | Supply & Fixing of Nut-Bolts with warsher of suitable sizes as per RESSPO manual. |
| 29 | Note: Any quantity of item from sl no. 1 to sl no. 28 may vary to any limit within the financial value of agreement against this tender. | Note: Any quantity of item from sl no. 1 to sl no. 28 may vary to any limit within the financial value of agreement against this tender. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender