Tender For Rewiring Of District Special Branch Office,Malappuram
Tender Value
3.13 Lakhs
Estimated cost
Bid Submission
25 Sep 2026
6 days left
EMD
7850
Bank guarantee accepted
Document Fee
767
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rewiring Of District Special Branch Office,Malappuram
BOQ
| Sl. No. | Item Description |
| 1 | ELECTRICAL WORKS |
| 2 | 1.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 4 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 5 | 1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, 2 waymodular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 6 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 7 | 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 1.14.9Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 9 | 1.15.1Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVCinsulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group A |
| 10 | 1.15.2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVCinsulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group B |
| 11 | 1.15.3Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVCinsulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group C |
| 12 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 13 | 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm |
| 14 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm |
| 15 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 16 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 17 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 18 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 19 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet |
| 20 | 1.15.2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVCinsulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group B |
| 21 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired. |
| 22 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 23 | 1.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). |
| 24 | 90.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )2 module moulded plastic box on surface |
| 25 | 90.10.1.3Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )3 module moulded plastic box on surface |
| 26 | 90.10.1.5Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )6 module moulded plastic box on surface |
| 27 | 90.10.1.6Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )8 module moulded plastic box on surface |
| 28 | 1.28.2Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module |
| 29 | 1.28.4Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module |
| 30 | 1.28.5Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module |
| 31 | 90.10.3.23Supply and Fixing the following modular switches & accessories in the existingfront plates and giving necessary connections as required (RoHS compliant )16A 3pin plug top |
| 32 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required.Net Total 30.000each |
| 33 | 1.38Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete asrequired. |
| 34 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required1 run of Cable |
| 35 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front onsurface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socketoutlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For lightplugs to be used in non residential buildings) |
| 36 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required |
| 37 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 38 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 39 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 40 | OD57037/2026-2027Supply, conveyance, installation, testing and commissioning of the 150 mm size ofexhaust fans in the existing opening, fixing necessary bolt and nuts, making good thedamages etc. as required including giving connections with required length of24/0.20mm PVC insulated and PVC sheathed 3core round copper conductor flex wireconforming to relevant ISS.-<br> |
| 41 | OD57038/2026-2027Supply, installation, testing and commissioning of 20W LED Tube Light fittings ofPHILIPS/ CROMPTON make or equivalent, giving connection on wall/ceilingconforming to relevant ISS etc. complete as required. |
| 42 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existingfront plates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator |
| 43 | 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 44 | OD57070/2026-2027Supply, Installation, Testing and Commissioning of Modular type RJ45 Socket inposition including modular front plate |
| 45 | 90.10.3.33Supply and Fixing the following modular switches & accessories in the existingfront plates and giving necessary connections as required (RoHS compliant )25A 3pinShuttered socket Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender