Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57582768

Tender For Provision Of Cook House With Dining Hall And Allied Works For Tabn Pattan Under Ge 969 Ews

Issued by Statutory Bodies & Commissions/Committees · Baramulla, Jammu and Kashmir
Tender Value
4.95 Crore
Estimated cost
Bid Submission
22 Oct 2026
19 days left
EMD
5.70 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Cook House With Dining Hall And Allied Works For Tabn Pattan Under Ge 969 Ews

BOQ

Name of Work:- PROVISION OF COOK HOUSE WITH DINING HALL AND ALLIED WORKS FOR TABN PATTAN UNDER GE 969 EWS
Sl. No. Item Description
1Note: (i) Please refer Schedule 'A' Notes given in tender documents.(ii) The Schedule 'A' Part-XV is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col. 5 signifies this fact only.
2LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
3Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I.
4Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-II.
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-III.
6Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-IV.
7Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-V.
8Lump sum price worked out by the contractor for PROTECTIVE WORKS carried forward from Pre-Priced Schedule 'A' Part-VI.
9Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-VII.
10Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII.
11Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-IX.
12Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-X.
13Lump sum price worked out by the contractor for CENTRAL HEATING SYSTEM WORKS carried forward from Pre-Priced Schedule 'A' Part-XI.
14Lump sum price worked out by the contractor for REFRIGERATION AND AC WORKS carried forward from Pre-Priced Schedule 'A' Part-XII.
15Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-XIII.
16MISCELLANEOUS ITEMS OF WORKS (SCHEDULE 'A' PART-XIV)(A) INTERNAL WATER SUPPLY WORKS
17S&F of two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. (flow rate - 8 LPM), ISI Marked, complete all as specified and directed.
18S&F Pillar Cock (Low-flow) 16 mm dia. (flow rate - 8 LPM) Chromium plated, ISI Marked complete all as specified and directed.
19Supply & fixing of Health faucet (ABS Body) (Low-flow) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook (flow Rate - 10 LPM) ISI Marked, complete in all respect as specified.
20S & F of Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves, ISI Marked, complete all as specified and directed.
21S &F of 15 mm bore PUSH Cock ( Low-flow) for urinal for iron pipe and fixed.( PRS-CHR-073) (flow rate -3.8 LPF), ISI Marked, complete all as specified and directed.
22S & F of Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges, ISI Marked, complete all as specified and directed.
23(B) INTERNAL ELECTRIFICATION WORKS
24S & F of modular type 1 module RJ-11 telephone scoket with shutter complete all as specified and directed.
25S & F of modular type 1 module co-axial type TV socket, complete all as specified and directed.
26Supply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with suitable for incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories complete all as specified and as directed.Note: Outgoing MCCB and MCBs shall be measured and paid separately.
27Supply and fixing load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with suitable for incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed.Note: Outgoing MCCB and MCBs shall be measured and paid separately.
28Supply and fixing LED light fitting 20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed.
29Supply and fixing of 12W Surface down light fitting with 220 V AC and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
30Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-1 (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-chargeMake: Schneider, Siemens, ABBThe PANEL shall comprise of the following:
31[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 100A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]80A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]40A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 04 Nos[ii]20A,230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos[iii]10A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos [iv] LED phase indicators (Red, Yellow, Blue)- 07 Set
32(C) EXTERNAL ELECTRIFICATION WORKS
33Supply and fix street light junction box mistral IP 65 thermoplastic enclousers with transperent door 4mm thick in 4 modulus in single row of size 210 x 155 x 92 with SP 0.5 Amp MCB and including clamp of size 20x3 mm thick of flate iron with bolt, nut etc required in mounting in steel toolbar pole 8.5 mtr long complete all as specified and directed.
34Supply and fixing of providing cement concrete type B1 (1;2;4) (20 mm graded aggregate)in precast posts for cable route indicator of size 500x300x100 mm rounded top as directed and grouting in ground with PCC (1:3;6) block of size 350mmx150mmx200mm including 10 mm thick plastering all around of exposed surfaces of post above ground with CM (1:4) and applying two coats cement base paint on plastered surface and writing with synthetic enamel paint in black colour in suitable size like HT Cable, complete all as specified and directed by Engr-in-Charge complete all as specified and directed.
35Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type MLTP PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.Make: Schneider, Siemens, ABB The PANEL shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 200A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]160A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.
36[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]125A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos ( 1 NOS - DG PANEL , 1 NOS SPARE)[ii]80A, 415 V, Ics = 100% Icu = 25kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos ( 1 NOS - PDB 1(BUILDING)[iii]40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos ( 1 NOS - APFCR PANEL + 1 NOS-SPARE)[iv]20A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos ( 1 NOS - PDB 2 (CHS BUILDING)+ 1 NOS-SPARE)[V] LED phase indicators (Red, Yellow, Blue)- 07 Set
37Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type DG PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. Make: Schneider, Siemens, ABBThe PANEL shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 200A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection
38[B] INCOMING[i]125A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i] 100A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos (1-CHS PANEL , 1 NOS SPARE)[ii]40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos (1 NOS- ACDB)[ii] 20A, 415 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos (FOR STREET LIGHT)[III] LED phase indicators (Red, Yellow, Blue)- 04 Set
39Supply, installation, testing and commissioning of free-standing indoor, modular, extendable, 25 kVAr APFC Panel having maintenance friendly semi compartmentalized bolted construction, made out of 1.6 mm thick CRCA sheet and built upon rigid framework, having MPP- HD box type capacitor with 7% aluminium wound reactor units type tested in accordance with fully type tested at an Independent laboratory and conforming to IEC 61439-1&2 and IEC 61921 or IS 16636: 2017 with contactor switching, IP 4X protection and including air system provided by axial flow fan or centrifugal fan, control wiring with FR-LSH copper wires complete as specified and directed by the engineer-in-charge.The APFC Capacitor Bank shall comprise of the following:
40[i] 40 A, 415 V, Ics = 100% Icu = Icw (1 sec for total selectivity) = 16 kA, 50 Hz electrical draw-out type 4P MCCB, conforming to IS/IEC 60947-2 & 3, having 100% neutral with inbuilt release protection, no derating up to 50 ⁰C, thermal based trip & LED based display systems with thermal memory providing overload, short-circuit, instantaneous & earth-fault protection, zone selective interlocking, pre-trip alarm & individual fault indicating LEDs, 20 trip record, % loading, bar graph, max. & min. meter and pre-alarm function for overload, short-circuit & earth fault - 01 Nos.[ii] High performance microprocessor based APFC relay with 3 CT sensing auto / manual switch option- 01 Nos.[iv] MPP-HD box capacitor of 25 (2 X 10 + 1 X 5 ) kVAr - 3 steps Please Enable Macros to View BoQ information
41[i] 40 A, 415 V, Ics = 100% Icu = Icw (1 sec for total selectivity) = 16 kA, 50 Hz electrical draw-out type 4P MCCB, conforming to IS/IEC 60947-2 & 3, having 100% neutral with inbuilt release protection, no derating up to 50 ⁰C, thermal based trip & LED based display systems with thermal memory providing overload, short-circuit, instantaneous & earth-fault protection, zone selective interlocking, pre-trip alarm & individual fault indicating LEDs, 20 trip record, % loading, bar graph, max. & min. meter and pre-alarm function for overload, short-circuit & earth fault - 01 Nos.[ii] High performance microprocessor based APFC relay with 3 CT sensing auto / manual switch option- 01 Nos.[iv] MPP-HD box capacitor of 25 (2 X 10 + 1 X 5 ) kVAr - 3 steps Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57582768
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 4.95 Crore
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Cook House With Dining Hall And Allied Works For Tabn Pattan Under Ge 969 Ews
Basic Detail
Tender No 800241
Bidding Type Tender
Location
City Baramulla
State Jammu and Kashmir
Key Dates
Publish Date 18 Sep 2026
Submission Date 22 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 4.95 Crore
Tender Fee 2000
EMD 5.70 Lakhs
Exemption Available
Document List
8b9ae5a9-b02e-4714-8399-1318a4ccd314.html
BOQ_885672.xls
DrgMerged1compressed.pdf
DrgMerged2compressed.pdf
TendercookhouseMerged.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

8b9ae5a9-b02e-4714-8399-1318a4ccd314.html

xls

BOQ_885672.xls

pdf

DrgMerged1compressed.pdf

pdf

DrgMerged2compressed.pdf

pdf

TendercookhouseMerged.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders