Housing Urban and Rular Development Local Bodies Closing in 3 days TDR #57582572

Tender For Providing 11 Kv Sub-Station For Charging Infrastructure Of E-Buses At Bus Depot Cum Workshop, Raipur Kalan, Chandigarh.

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
4.70 Crore
Estimated cost
Bid Submission
12 Oct 2026
3 days left
EMD
9.41 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing 11 Kv Sub-Station For Charging Infrastructure Of E-Buses At Bus Depot Cum Workshop, Raipur Kalan, Chandigarh.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Oct-2026 Date Extend Date 12-Oct-2026

BOQ

Name of Work:- Providing 11 kV Sub-Station for Charging Infrastructure of E-Buses at Bus Depot cum Workshop, Raipur Kalan, Chandigarh.
Sl. No. Item Description
1DSR item No. 3.13:Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Busbar Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
23200 A, Isc= 50kA for 1 sec
3DSR item No. 5.6:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4DSR item No. 5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5DSR Item No. 23.4Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
6120 sq. mm
7400 sq. mm
8DSR item No. 24.4.4(11/0.433 KV, 3 Phase, 50 Hz outdoor/ indoor mounting (Mineral oil filled) (Please refer DNIT for complete specification of item no.5)
92000 KVA
10DSR item No. 2.22Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
11Supply, installation, testing & commissioning of 3 phase, 50Hz, 11KV, 800 Amp, 26.3KA/3Sec. incoming VCB panel with copper busbar for indoor substations. The VCB should be floor mounted trolley type horizontal isolation, horizontal draw out, type Breaker confirming to IEC-62271-100 & Panel as per IEC- 6227I-200, & IEC-60694 as amended up to date. (Please refer DNIT for complete specification of item no.7)
12Supply, installation, testing & commissioning of 3 Phase, 50Hz, 11KV, 800 Amp, 26.3KA/3Sec. outgoing VCB panel with copper busbar for indoor sub stations. The VCB should be floor mounted trolley type horizontal isolation, horizontal draw out, type Breaker as per IEC-62271-100 & Panel as per IEC- 6227I-200, as amended up to date.(Please refer DNIT for complete specification of item no.8)
13Main LT PanelSupplying, installation, testing and commissioning of modular, sectionalized Low Voltage (LV) Panel of Form–4B construction, suitable for 415 V, 3 Phase, 4 Wire, 50 Hz AC supply system, conforming to IEC 61439-1 and IEC 61439-2, as a Totally Type Tested Assembly/ Design Verified Assembly, fabricated in a compartmentalized design. (Please refer DNIT for complete specification of item no.9 )
14Supplying and laying of one number 11KV Grade HT XLPE insulated, PVC sheathed, armoured, Aluminium conductor cable conforming to IS 7098 (Part-2) 1985 with latest amendments for an earthed system of the following size, to be laid in the existing HUME/ RCC/ DWC/ GI Pipe/ Open Duct/ Trench etc., as required at site, to the entire satisfaction of the Engineer-in-Charge of work. The job includes the cost of making connections with suitable size of aluminium lugs/ thimbles, testing, commissioning etc. The cable shall be of Polycab/ KEI/ RPG/ Unistar (Universal)/ Havells/ Finolex/ R.R. Kabel make only.
15Size 400 sq.mm 3 core
16Size 120 sq.mm 3 core
17S/E of 4 nos. sand buckets of 10 ltr. Capacity each made out of 24 Gauge G.I sheet. The buckets with sand shall be hanged on Suitable size of angle iron stand fabricated out of 1 ¼ x 1 ¼ x1/8” angle iron having hooks for hanging the buckets in two rows. The job includes the cost of painting with two coats of red paint of superior quality after one coat of primer on buckets and stands to complete the job up to the entire satisfaction of the Engineer–in–charge.
18Supply of Erection of medium-size first aid box made of 16-gauge MS sheet of size 14”x7”x5” with 6 wound dressings, 3 burn dressings, 13 gms absorbent cotton wool, one dressing scissors, one bottle of spirit of sal volatile, 1 tube of burn ointment (Burnol) tablets of aspiring, 1 No. artificialrespirator.
19Supply and Erection of shock treatment chart written in Hindi and English and local language duly framed in wood frame with glass complete as required as per India Electricity Act. (Safety rules).
20Supply and Erection of Fire Extinguishers ISI marked duly erected/ hung on wall with hooks including the cost of hooks with all material & labour required to complete the job in all respect upto the entire satisfaction of the Engineer-in- charge of work.
21CO2 type of 9 Kg capacity fire extinguishers conforming to IS.
22S/E rubber mat of size 6’x3’x 12 mm thick (ISI mark) Wide of superior quality and of approved make as approved by the Engineer –in- Charger /EC to be laid on floor in HT room in Front of panels and transformers.
23S/I/T/C of Power Pack with 220 Volt AC supply input and 24 Volt DC continuous output, suitable for closing/tripping/ indication of HT VCB breakers, provided with 2 Nos. 12 Volt each, SMF batteries of 100 AH capacity, Charging unit and suitable capacity of multifunction meter for current and voltage including connection with 2.5 Sq.mm FRLS insulated copper conductor cable etc. duly houses in cabinet of size (L x W x D) 36”x24”18” made of 14 gauge CRCE sheet having 4 Nos. legs of 8” length made of MS angle of size 50 x 50 x 6mm. (Please refer DNIT for complete specification of item no.16)
24Gas Suppression SystemSupply, installation, testing and commissioning of clean Gas Based Fire Suppression System suitable up to 2 cum volume. The clean agent with zero ODP as per NFPA 2001, UL listed with container conforming to applicable fixed fire suppression system standard, electrical non-conductive clean agent capacity 2 kg comprising of 10 m heat sensing tube (HST) made of polyamide (UL/ LPCB listed) size of tube 4 mm ID and 6 mm OD. (Please refer DNIT for complete specification of item no.17)
25Supply, Erection, Testing and Commissioning of Modular Type, Thermally Actuated (self-operated) on 68°C operating temperature clean agent fire extinguishing system, complete with cylinder, valve, discharge nozzle and mounting accessories, conforming to NFPA 2001/ relevant IS standards, duly CE/ UL/ FM/ LPCB certified, Fire Extinguishers filled with approved Clean Agent Gas (equivalent to FK-5-1-12/ HFC-227ea) of approved make: Victor/ Adasi/ Ceasefire/ Minimax/ NAFFCO only. The job includes the cost of all incidental and petty materials required for proper installation & commissioning, complete in all respects, to the entire satisfaction of Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57582572
AUTHORITY Local Bodies
TENDER VALUE 4.70 Crore
LAST DATE 12-10-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Providing 11 Kv Sub-Station For Charging Infrastructure Of E-Buses At Bus Depot Cum Workshop, Raipur Kalan, Chandigarh.
Basic Detail
Tender No E2/26/113
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 01 Oct 2026
Submission Date 12 Oct 2026
Open Date 12 Oct 2026
Finance
Tender Value 4.70 Crore
Tender Fee Ref. Documents
EMD 9.41 Lakhs
Exemption Not Available
Document List
1d5fc963-511d-4200-852e-b7548f435e18.html
BOQ_117411.xls
Tendernotice_1 (33).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

1d5fc963-511d-4200-852e-b7548f435e18.html

xls

BOQ_117411.xls

pdf

Tendernotice_1 (33).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders