Housing Urban and Rular Development Government Departments Closing in 34 days TDR #57582432

Tender For Electrification Work Of Proposed Media Centre And Guest House Building Tanakpur Disstrict -Ch Awat

Issued by Government Departments · Champawat, Uttarakhand
Tender Value
2.94 Crore
Estimated cost
Bid Submission
27 Oct 2026
34 days left
EMD
5.89 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Champawat → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrification Work Of Proposed Media Centre And Guest House Building Tanakpur Disstrict -Ch Awat

BOQ

Name of Work:- Electrification work of Proposed Media Centre and guest house Building Tanakpur Disstrict -Ch awat
Sl. No. Item Description
1Media CentreSUB-HEAD - I : INTERNAL WIRING
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group - C)
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4b: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
5c: 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
6d: 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
7e: 4 x 2.5 sq.mm + 2 x 2.5 sq.mm. earth wire
8f: 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire
9g :4 x 10 sq.mm + 2 x 6 sq.mm. earth wire
10h: 4 x 16 sq.mm + 2 x 6 sq.mm. earth wire
11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a: 3 x 1.5 sq. mm
12b: 3 x 2.5 sq. mm
13c: 3 x 4 sq. mm
14Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
15Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
16Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
17Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
18Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
19Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
20Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required a: 5/6 A switch
21b:3 pin 5/6 A socket outlet
22Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
23Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
24Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
25Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes
26LIGHT FIXTURES: Supply & Fixing of Recess mounting 2x2 feet 36W to 42W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
27Supply & Fixing of LED 4ft Batten 18w to 22w with a nominal system lumen output and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PC diffuser . ( PRESSURE DIE CAST AL with HEAT SINK)
28Supply & Fixing of Recess mounting round 10 Watt 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
29Supply & Fixing of Recess mounting square 18 to 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.( PRESSURE DIE CAST AL with HEAT SINK square & round)
30Supply & Fixing of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.
31Supply & Fixing of LED 2ft mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required.
32Supply & Fixing of LED 24 Watt 5 meter strip for cove light with suitable driver, suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
33Supply & Fixing of LED 20 Watt to 25 Watt Track light with 1 meter Track, suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
34Supply & Fixing of LED 20 Watt to 25 Watt Gate light , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
35Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
36Supply & Fixing of 300mm EXHAUST FAN complete as required.
37DISTRIBUTION BOARD
38Providing and fixing of 63 A, rating and 25KA,breaking capacity and four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.
39Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a: 6 Way Double Door
40b: 12 way, Double Door
41Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a: 4 Way Double door
42b: 6 way Double door
43c: 8 way Double door
44Supplying and fixing 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)
45Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a: Single pole
46b: Double pole
47c: Triple pole
48d: Triple pole and neutral
49Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
50Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
51Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.
52M.V. PANELS
53Supply installation testing and commissioning of LT panel Board for the extension of existing panel as per the following specification with proper copper earthing as recommended. The panel should be Designed as per the latest standard IEC 61439. The panel should have Bus bar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyester glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as Form of separation. The panel should be equipped with suitable size of CT and display meter for VAF measurement. The panel should be suitable for seismic zone V.LT Outgoing should be IP 54 and should have switchgears as below. MainLTPanel : INCOMER:-a: 1 No 500 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity b:1 No 100 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity METERING :- 2 No. Multi Function Meter. 1 No. CT FOR APFC PANEL 2 Set of phase indicating lamps with Single Pole MCB. 2 Set of ON / OFF indicating lamps with Single Pole MCB. 2 Set 50,50N,51,51N,27,32,49,59,86,95 CT's control. BUS BARS:- 750 Amps. TP&N aluminium bus bars OUT GOINGS:-1 Nos. 250 Amps. FP MCCB thermal magnetic release2 Nos. 160 Amps. FP MCCB thermal magnetic release2 Nos. 125 Amps. FP MCCB thermal magnetic release1 Nos. 100 Amps. FP MCCB thermal magnetic release2 Nos. 32 Amps. FP MCCB thermal magnetic release2 Nos. Space & Spare
54EM PanelINCOMER:- 1 No 100 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking CapacityMETERING :-1 No. Multi Function Meter.11 Set of phase indicating lamps with Single Pole MCB.1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:- 150 Amps. TP&N aluminium bus barsOUT GOINGS:-4 Nos. 32 Amps. FP MCB2 Nos. 32 Amps. DP MCB2 Nos. Space & Spare
55Main Power Panel:INCOMER:- 1 No 160 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking CapacityMETERING :-1 No. Multi Function Meter.11 Set of phase indicating lamps with Single Pole MCB.1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:- 250 Amps. TP&N aluminium bus barsOUT GOINGS:- 6 Nos. 32 Amps. FP MCB2 Nos. Space & Spare
56Main AC Panel :INCOMER:- 1 No 125 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking CapacityMETERING :-1 No. Multi Function Meter.11 Set of phase indicating lamps with Single Pole MCB.1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:- 200 Amps. TP&N aluminium bus barsOUT GOINGS:-6 Nos. 32 Amps. FP MCB2 Nos. Space & Spare
57CAPACITOR PANEL-50 KVARSITC APFC Panel of 50 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static 5,10,15,25 KVAR capacitors (without oil) in tier formation complete with following TPN MCCB as incomer of the panel, 3 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated.Incoming:1No 125 Amp. 4P MCCB of 25 KA Breaking capacity BUS BAR : 1 Set of 150 Amps TPN Aluminium Bus Bars OUT GOING : 01 No. 63 Amps. TP MCB (10 KA) - (25KVAR)01 No. 40 Amps. TP MCB (10 KA) (15KVAR)01 No. 25 Amps. TP MCB (10 KA) - (10KVAR)Panel described as above
58TRANSFORMER (11 KV / 0.433 KV)Supply, Installation, testing and commissioning of 400 KVA. 11/0.433 KV, 3 Phase, 50Hz, Dyn 11, Oil type, copper wound transformer with ON load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% , having cable end boxes on HV side and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site.
59RMU SYSTEMDesign, manufacturing, testing at works, supply of 1 No. 11KV, 630A, 21kA/3 Sec Outdoor type, extensible SF6 gas insulated Ring Main Unit equivalent to Ringmaster RE6C+CE6 with 1 Nos. On Load Cable isolator and 1 No. Vaccum Circuit breaker enclosed in a stainless steel tank with self powered microprocessor based numerical relay and dedicated Ct's for protection of Transformer comple as required and as per specification
6011 KV DOUBLE POLE STRUCTURESupply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,200A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following.a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc.b. 1 Set of cross arms, branching, clamps and painting complete with GI nut, bolts & washers as required (for GO & DO), LA connection.c .1 set 11KV Insulator complete with spindles & hardware complete as required.d .1 No. 11KV 400A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement.e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses, and mounting arrangement.f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases.h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA)i: 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices.11 KV Double Pole Structure described below
61FIRE DETECTION SYSTEM
62Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
63Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
64MANUAL CALL POINTSupplying, installation, testing & commissioning of addressable manual call point complete as required
65RESPONSE INDICATORSupplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
66Hooter cum strobe Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
67Reapter PanelSupplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
68FIRE ALARM CONTROL PANEL Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications A-10 Zone panel for fire alarm system
69Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required
70CABLE TRAY
71Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. a: 100 mm wide x 50 mm depth x 1.6 mm thickness.
72b : 150 mm wide x 50 mm depth x 1.6 mm thickness
73Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. a:100 mm wide x 50 mm depth x 1.6 mm thickness.
74b:150 mm wide x 50 mm depth x 1.6 mm thickness.
75Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. a:100 mm wide x 50 mm depth x 1.6 mm thickness.
76b:150 mm wide x 50 mm depth x 1.6 mm thickness.
77UPS SYSTEM
78Supply, Installation, Testing and Commissioning of true parallel redundant 1 X 5 kVA, online, UPS system suitable for providing power supply to emergency lighting at station & viaduct, Platform edge door and Computerised Control panel load of approved make, suitable for incoming 415 volts, single phase +10 % ‐ 20%, 50 Hz, supply and single phase output voltage, variation ± 1%, including transformer, rectifier/dual converter, static switch, inverter, filter, Bypass & static transfer switch for automatic switch over without giving any break of power, maintenance bypass switch, Micro processor/ software controlled annunciation,protection(including against input phase reverssal), and menu run diagnostic module,associated cabling and connections/ terminations, erection including associated foundation/ masonorey or RCC work for mounting on base channels etc. complete as per specifications and as required. Supply, Installation, Testing and Commissioning of lead acid sealed maintenance free suitable for 30‐minute‐battery backup to the UPS set. Battery shall comply with relevant regulations & Battery racks shall be made of acid resistant material UPS described as above
79Solar Photovoltaic Power Plant
80Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
81Lightning Protection
82Air Termination Network:SITC of single spike air terminals of 10 mm dia. & 1500 mm length as required and as per site conditions. The air terminal shall be manufactured with aluminium & shall be as per IEC 62561-2. The air terminal shall be fixed with base plate arrangement.
83Roof Conductor for Parapet & Mesh :Supply of 8 mm dia aluminium round conductor for air termination network at parapet and for making mesh at terrace level and shall meet the requirement of IEC 62561-2.
84Supply of Parapet Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor holder shall be mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr.
85Supply of Mesh Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor holder shall be fixed on plastic support weighed by concrete block. It shall meet the requirements of IEC 62561-4 and should be installed at every 1 mtr.
86Bridging cable: Supply of 16sq.mm. copper cable along with lugs, having 500mm length & as per IEC 62561-1 so as to connect air termination rod with any metallic structure on the roof.
87Supply of Universal Connector for making straight, Tee & Cross joint of 8 mm Aluminium Conductor to 8 mm dia Aluminium conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work.
88Down Conductor : Supply of 8 mm dia aluminium round conductor for Down conductors to be installed on vertical wall, façade of masonary / glass / metalic work. It shall meet the requirements of IEC 62561-2.
89Supply of Wall Conductor holder for holding 8 mm dia. round conductor (for RCC wall). The conductor holder should be installed at every 1 mtr. The conductor holder shall be made with clamp mounted on plastic base support & as per IEC 62561-4.(Part No. JMV/H8A800)
90Supply of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value. (with enclosure). It shall meet the requirements of IEC 62561-2.
91Supply of Expansion piece made of 8mm dia. Aluminium & as per IEC 62561-2 along with suitable connecting accessory. It shall be installed at every 20 mtr to maintain the flexibility to the conductor due to heat.
92Supply of Lightning Strike counter Model: JMV 7D for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 68 rated enclosure suitable for external application.
93Earth Termination Network: Supply of Earthing termination made of copper-bonded rod of 10 feet length,14.2 mm dia. (Minimum copper bonding shall be 0.25mm) as per IS 3043, IEEE-80, NBC 2016 along with Earth enhancement material some with resistivity of 0.12 ohm-mtr, and complying IEC 62561-7 and Pit Cover complying IEC 62561-5 and other accessories as required and as per specification and other applicable codes.
94Supply of 8 mm CBS Conductor laid below the ground, as Required and as per specification and code of practice with Tee and Straight joint.
95Geyser Equipment
96SITC of 25 Ltr. Glass line Geyser with all accessories
97AC Equipment
98SITC of 2 Ton 3 star Hot and Cold Split Air Conditioner, connecting outdoor unit with copper pipe with required insulation
99S/F MS Outdoor Stand
100S/F 5 KVA Stabilizer copper winding
101S/L 3 x 2.5 Sqmm core flexible Copper Counductor
102S/L drain Pipe 25mm with Albow socket
103S/L Copper Refrigerent pipe 5/8 and 1/4
104LiftSupply,Installation,Testing and Commissioning of Electric Traction Passenger Lift with• Rated capacity :- 10 Passenger/680Kg• Floors :- Basement to Fourth floor (6 Stops / 6 Landings)• Travel :- 21.6 mtrs to 24 mtrs.• Location of Lift Machine:- without Machine Room• Rated speed :- 1.0 mps VSElevator Type :Passenger elevator PWI10/10-19Product : IMonospaceNo of Units : 1Load & Capacity : 680 kg or 10 personsSpeed : 1 m/sStops & Openings : 6 stops & 6 openings, Single entrance caTotal no of opening :1 entrancesTravel height :21.6 m Elevator Grouping : Simplex Full Collective ControlWell Dimension : 1654 mm width and 2100 mm depth (required)Head Room height :3800 mm (required)Pit Height : 1400 mm (required)MAP Floor Position :Topmost floor (TOP)Car dimensions :1100 mm wide x 1600 mm deep x 2200 mm high Door dimensions :800 mm wide x 2000 mm internal heightDoor type :Two-panel to left opening Plain Panel Car design :SS silver mirror
105Car Panel Finish:Side walls: Stainless steel Hairline AISI441Rear wall: Silver mirror polished stainless steelFront wall: Stainless SteelHandrail :Round Bend Handrail Silver brushed stainless steel (ST4) at RearWallCeiling & Lighting :Integrated Roof RL20 Stainless Steel Ring Lighting LEDFlooring : 20 mmCar skirting material: Stainless steel Hairline AISI441Standard1:Correction drive to next level. 2:Emergency Alarm @ Main FloorCar Call backwards. 3:Overload function, constant indication/Buzzer 4: Bypass load Function5:Auto Cut off Fan and Light 6: Manual Rescue Operation7: Centralized Hoisting for lesser vibration and smooth travel8:Pit Ladder 9: Micro movement Led Based Buttons 10: L.W.D. (Load Weighing Device) 11: Direction & Position Indicator In Car & Landing 12: Advanced Car Position Indication 13:Automatic Brake Test function every 11hours 14: Every run brake supervision.15: Phase reversal functioning 16: Signal Fixtures. 17:+10% to –10% Voltage Fluctuation Withstanding Capacity18:Door Close Button. 19: Door Open Button.20:Car Emergency Light.21: Fireman Drive.22:Curtain of Light 169 Beams.23: Accurate Relevelling, Automatic, Closed Door.24.E, With emerg.opening deviceAdditional: 1:Emergency Rescue Device with audio announcer.2: Way Dedicated Intercom.3: Attendant Service 4: Parking Predefined floor - Doors closed.5: BMS.6:Ring Lighting LED.7: Access Control ProvisionA, 1 Hour Fire rated
106EPABX & LAN SYSTEM
107Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:a: 2 Pair (4 core)
108Supply, Laying Connectig ad testing of multi core (10 Pair) Telwphone cable of conductor size 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed jelly Filled.
109Supply,Laying connecting and Testing of 10 Pair cross Jumper type Telephone tag block krone make in surface /recess in wall required size of M.S box with hinged lockable dully stove enamel painted
110Supply,Laying connecting and Testing of 10 Pair telephone tag block krone make in surface /recess in wall.Requried size of M.S box with hinged lockable duly stove enamel painted.
111Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as requireda:1 or 2 Module (75mmX75mm)
112Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a: Telephone socket outlet
113RJ-45 Data Socket outlet
114Supply,Installation Testing and Commissionning of Hybrid Server based PaBX with 40 analog Extension ,4 digital Extension 04 CO with CLI Facilities system.
115Supply and Installation of CLI based push button telephone set.
116Propriatary Full duplex HF digital phoe set with 12 ouble function programmable keys,4 line display ,call waiting ,3 way confrence,call transfer,User to user signaling.
117Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
118Supply Installation testing and commissioning of 24 port L2 Managed switch having port density 24 No.of 10/100/1000Mbps/4 1 G SFP Ports.
119SITC of UTP CAT 6 UTP Patch Cord 3 Mtr
120Supply and Fixing of 12 U wall mounting Networking Rack.
121Supply Punching and Fixing of 24 ports Patch Panel
122Supply,Laying of UNI Tube Single Mode 6 F Armored Fiber Optic Cable
123Labour chagres for optical fiber cable splicing and jointing with Termination.
124Supply and Fixing of 6F port LIU box fully Loaded.
125Supply and Fixing of Single Mode Patch cord LC to LC 3mtr.
126Supply and Installation of Single Mode SFP Module For Switch
127Supply and Fixing of 25 mm Sizes of Medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good thw same in case of recessed conduit as requried.
128CCTV SYSTEM
129S.I.T.C. of 4 MP or better Indoor Dome camera fix Lens with 1/3'' Progressive Scan CMOS or better image sensor, Image Resolution :2560x1440 or better 30 FPS ,Wide Dynamic range - 120 dB or better, Day/Night operation, Electronic Shutter 1/25 to 1/15000 or better, Compression- H.265 or better, 3.2 to 9 mm or better, Varifocal lens with motorized zoom and focus, SSD Storage at Edged 64 GB from day 1 and expandable upto 128 GB, Motion detection, camera tampering protection ,IR Range up to 30 mtr or above , ONVIF, Profile S. Operating Temperature - -10 °C to 50 °C. STQC APPROVED
130S.I.T.C. of 4 MP or better Bullet camera 3 to 9 mm or better Fix lens, Camera Type: outdoor bullet camera Housing with IP66/67 and IK 10 rating, IR distance 50 mtrs or above with variable beam angle/intensity. Image Sensor : 1/3\\" Progressive Scan CMOS or better, Image Resolution : 2560x1440 or better at 30 fps, Compression : H.265 or better, WDR 120 db or better, Shutter speed 1/30 to 1/15000 or better, line crossing, idle object, removed object, intrusion, motion detection, tampering protection, IP Address Filter , Day and Night, ONVIF: Profile S. Environmental rating IP66/67 and IK 10 Rated or better, SSD Storage at Edged 64 GB from day 1 and expandable upto 128 GB. Operating Temperature - -10 °C to 50 °C.STQC APPROVED
131S.I.T.C of all-in-one recording, viewing and management solution for network surveillance systems for up to 64 channels, Pre-installed, preconfigured IP storage solution, with RAID-5 protected (RAID-5 with hot spare or RAID-6 supported),Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management, Intel® Core™ i3-10100E(6 MB Intel® Smart Cache,3.20 GHz),16GB DDR4-2933 2Rx8 ECC UDIMM, installed1U rack mount,4 Trays:3.5-inch SATA 4,max 18TB per HDD slot maximum supported, 4 x 8TB HDD to be offered,6 USB ports; Intel onboard graphics (Three digital outputs),Microsoft Windows Server IoT 2022 for Storage UL, CE Certified.2 x RJ45 Gigabit Ethernet LAN ports (teamed);Operating temperature (°C) 0°C to +40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Management software Inbuilt (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection (1, 2X2, 3X3 and 4X4), Sequencing selection), favorite view design. Dual authorization login, e Map support, ONVIF profile S,T complied, User management, Alarm management, SQL based database, DAP support. Support of camera edge based analytics/server based analytics alarm triggering. Certifications - BIS, STQC APPROVED
132VMS base license for viewing and recording for 1 camera.
133SITC of 75 Inch display : Screen Size : 75, Brightness (cd/m 2 ) : 440,Response Time (ms) : 8.0, Display resolution (H x V, pixels) ;3840 x 2160, Full Array LED Backlight, 4K HDR Processor X1 , 178 degree Viewing Angle (Right/Left/Up/Down), HDR10,HLG,Dolby Vision Compatibility, On-board Storage (16GB or more), Wi-Fi Direct, Wi-Fi Certified & Wireless LAN, Chromecast & Apple AirPlay built in, HDCP 2.3, Ports and Connectivity HDMI (4), Digital Audio Out (1), USB (2), Ethernet (1) , Power consumption Not more than 310 W, Operating System : Android TV, On-board Storage (GB) : 16GB.
134Supply Installations Testing and Commissioning of 8 PORT POE Managed Switch with 2 SFP ports 8X10/100/1000 advance layer 2 Switch. Power Budget should be sufficient (minimum 65Watt) to calculate the total Budget of cameras on site STQC APPROVED
135S/D of UTP 4 Pair CAT 6 LAN cable in the existing PVC conduit as required
136S/F of 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
137Miscellaneous
138Providing and fixing HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required.
139Supplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
140Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
141Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.)
142Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.
143HT CABLES
144Supply & Laying of 3 core stranded aluminium conductor 11KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments). Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required a:70 sq. mm 3 core
145supplying and making indoor cable end termination with heatshrinkable jointing kit complete with all accessories includinglugs suitable for following size of, XLPE aluminiumconductor cable of 11 KV grade as required 70 sq. mm
146Supplying and making outdoor cable end termination with heatshrinkable jointing kit complete with all accessories includinglugs suitable for following size of 3 core, XLPE aluminiumconductor cable of 11 KV grade as required70 sq. mm
147D.G. SETS
148Supplying, Installation and commissioning of AMF start silent type 58.5KVA/62.5KVA DG set comprising of suitable BHP diesel engine directly coupled to 3 phase 50 Hz 415 V alternator of 58.5 KVA/62.5 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB IV normsAMF Panel Incoming-100 Amps FP MCCB of 25KA breaking capacity and contactor same rating
149EARTHING
150Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
151Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
152Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
153Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
154Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
155Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required
156L.T. CABLES
157Supply & Laying of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.a: 3.5 x 185 sq.mm
158b: 3.5 x 95 sq.mm
159c: 3.5 x 70 sq.mm
160d: 2 x 4 sq.mm
161Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.a: 2 X 6 sq. mm (19mm)
162b: 3½ X 70 sq. mm (38mm)
163c:3½ X 95 sq. mm (45mm)
164d: 3½ X 185 sq. mm (57mm)
165Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.a: 100mm dia
166b:150 mm dia
167Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
168INTERNAL FIRE FIGHTING WORKS (HYDRANT SYSTEM)
169Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :a: 100 mm dia
170Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :a: 100 mm dia.
171Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :a: 80 mm nominal bore
172b: 100 mm nominal bore
173Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal
174Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a:20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b: 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.a: 40 m
175Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun metal
176Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal
177Providing and fixing standard fire mans axe with heavy duty insulated rubber handle.
178Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door: 900mm Wide & 1500mm Height)
179Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
180Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
181Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
182SPRINKLER SYSTEM
183Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :a: Pendent type sprinkler
184b: Upright Sprinkler
185c:Horizontal side wall sprinkler
186Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.a: Length upto 1000 mm
187b: Length upto 1200 mm
188Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :a: 150 mm nominal bore
189b: 100 mm nominal bore
190c: 80 mm nominal bore
191d: 65 mm nominal bore
192e: 50 mm nominal bore
193f: 40 mm nominal bore
194g: 32 mm nominal bore
195h:25 mm nominal bore
196Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.A: 100mm dia
197Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :a: 100 mm dia.
198b: 50 mm dia.
199Supplying, installation, testing & commissioning of Test and Drain Valve Assembly, including accessories such as test valve, unions, sight glass & drain valve for 50mm pipes size complete as required.
200FIRE EXTINGUSHER
201Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
202Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
203Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.
204FIRE PUMP ROOM & EXTERNAL WORKS
205FIRE PUMPS - ELECTRICALSupplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads.A: 2280 lpm at 70 m Head
206FIRE PUMPS - DIESEL ENGINE DRIVENSupplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plasteredand with anti vibration pads.A: 2280 lpm at 70 m Head
207JOCKEY PUMP:-Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.A: 180 lpm at 70 m Head
208Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
209Pressure VesselProviding, fixing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.working pressure:- 7 kg/sqcmtest pressure: 10 kg/sqcm(450 mm dia & 2000 mm height)
210Providing & fixing of Anti vibration Expansion Bellow at pump outlet etc. as required.A: 150 mm dia.
211B: 80 mm dia.
212Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required
213Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :a: 200 mm dia.
214b:150 mm dia.
215c:100 mm dia.
216d:80 mm dia.
217Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :a: 200 mm dia.
218b: 150 mm dia.
219c: 80 mm dia.
220Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.A: 200 mm dia.
221Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS)a: 150 mm dia.
222b: 100 mm dia.
223c: 80 mm dia.
224Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (PUMP ROOM WORKS)a:80 mm nominal bore
225b: 100 mm nominal bore
226c: 150 mm nominal bore
227d: 200 mm dia (wall thickness 6.3 mm)
228Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :a:150mm dia
229Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :a: Single headed Gunmetal
230Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required
231Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :a: Gun metal
232Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
233Providing and fixing standard fire mans axe with heavy duty insulated rubber handle.
234Providing & Fixing of M.S. fire hose weather proof cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & \\"FIRE HOSE\\" written on front.
235Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :a: 2 way - 100 mm dia M.S. Pipe (Siamese Connection)
236b: 4 way - 150 mm dia M.S. Pipe
237ELECTRICAL WORKSFIRE FIGHTING PANEL Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required:INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0 500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300AOUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
238Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump63A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engineSystem ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
239Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as requireda: 8 x 2.5 sq.mm
240b: 6 x 2.5 sq.mm
241c: 4 x 2.5 sq.mm
242d: 2 x 2.5 sq.mm
243Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge. It should be complete as per specifications & directions of Engineer-in-charge.
244Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.A:150 mm width x 50mm depth x 1.6 mm thickness.
245Guest houseSUB-HEAD - I : INTERNAL WIRING
246Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group - C)
247Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
248b: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
249c: 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
250Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. A: 3 x 1.5 sq. mm
251b: 3 x 2.5 sq. mm
252c: 3 x 4 sq. mm
253Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
254Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
255Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required)
256Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
257Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required a: 5/6 A switch
258b:3 pin 5/6 A socket outlet
259Supplying and fixing brass batten/ angle holder including connection etc. as required.
260Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
261Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
262Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
263Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes
264Supply & Fixing of LED 4ft Batten 18w to 22w with a nominal system lumen output and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PC diffuser . ( PRESSURE DIE CAST AL with HEAT SINK)
265Supply & Fixing of 9W to 15 W LED Wall Light Blub complete in all respect
266Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
267Supply & Fixing of 300mm EXHAUST FAN complete as required.
268DISTRIBUTION BOARD
269Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a: 4 Way Double door
270Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a: Single pole
271d: Triple pole and neutral
272Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
273Geyser Equipment
274SITC of 25 Ltr. Glass line Geyser with all accessories
275Miscellaneous
276Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work
277Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.
278L.T. CABLES
279Supply & Laying of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.a: 4 x 6 sq.mm
280Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.a:4 X 10 sq. mm (25mm)
281Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.a: 100 mm dia
282Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57582432
AUTHORITY Government Departments
TENDER VALUE 2.94 Crore
LAST DATE 27-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrification Work Of Proposed Media Centre And Guest House Building Tanakpur Disstrict -Ch Awat
Basic Detail
Tender No 1279/02CB-05/26 DATE 11/09/2026
Bidding Type Tender
Location
City Champawat
State Uttarakhand
Key Dates
Publish Date 18 Sep 2026
Submission Date 27 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value 2.94 Crore
Tender Fee 5900
EMD 5.89 Lakhs
Exemption Not Available
Document List
BOQ_118252.xls
f3fc0141-2d14-411d-9e27-5ae365b90cd4.html
techbiduploaded.pdf
Tendernotice_1 (33).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 34 days
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 35 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_118252.xls

html

f3fc0141-2d14-411d-9e27-5ae365b90cd4.html

pdf

techbiduploaded.pdf

pdf

Tendernotice_1 (33).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders