Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57582427

Tender For Electrification & Allied Works Of Academic Block-Ii At Dr. A.P.J. Abdul Kalam Institute Of Technology Tanakpur (Uttarakhand)

Issued by Government Departments · Champawat, Uttarakhand
Tender Value
32.10 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
6 days left
EMD
64000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Champawat → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrification & Allied Works Of Academic Block-Ii At Dr. A.P.J. Abdul Kalam Institute Of Technology Tanakpur (Uttarakhand)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Sep-2026 Corrigendum Fee 01-Oct-2026

BOQ

Name of Work:- Electrification & Allied Works of Academic Block-II at Dr. A.P.J. Abdul Kalam Institute of Technology Tanakpur (Uttarakhand)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
2Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required.
3Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
5Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
7Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 20 mm
8Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
9Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
10Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
12Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
13Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm)
14Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
15Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
16Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
17Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
18Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
19Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required.(Note : More than 5 cm length shall be rounded to the nearest10 cm and 5 cm or less shall be ignored)
20Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
21Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
22Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( without independentswitch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulatedcopper conductor single core cable etc. as required.GROUP C
23Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door
24Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
25Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
26Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
27Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.63 A
28Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
29Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.150 mm width X 50 mm depth X 1.6 mm thickness
30Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.150 mm width X 50 mm depth X 1.6 mm thickness
31Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.
32Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
33Supply, Installation, Testing and Commissioning of On line UPS with 20 Min Backup including Batteries , Incerconnecting cables , Battery Rack completein all respect.
34Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 125 A, 36KA,FPMCCB
35Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door
36Supply of 20 Watt LED Linear Metal Construction commercial batten fitting with fuse protection suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for both surface & suspended Mounting, complete in all respect 2000 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge., Make Philips BN021C LED20S PSU CW GR S2 or eqivalent as per approved make
37Supply of Aluminium alloy Wall lamp, 5 Watt Power Source 220V AC,Type Wall Mounted , Number of Light souce 1 Shade Direction Up-Down Lamp Shape others Wattage 5 Watt, Lighting source life 10000 hour Lighting Type LED General , Top Cover Material Arcylic coverWeight 200 gram Overall Dimension 75x75x50 mm Finish Powder Coated Warranty 36 month Comlete in all respect
38Supply of Aluminium alloy Focus light , 9 Watt Power Source 220V AC,Environmental friendly, new generation, energy saving, decorative IP66 LED spike light using Focus/COB LED as light source. Comlete in all respect
39Supply of Exhaust fan 250 mm sweep metal body with 50 HZ 230 volt ac complete with all respective accessories.
40Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
41Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
42Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
43Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
44Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
45Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
46Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
47Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
48Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
49Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering andrefilling the trench etc as required. Upto 35 sq. mm
50Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 4 X 10 sq. mm (25mm)
51Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4CX10 SQMM AL ARMOURD CABLE
52Supplying & laying 1.1 kv grade ISI marked synthetic rubber mats as per specifications of chief electrical inspectorate.
53Supplying & fixing of shock treatment chart printed in hindi and english fitted in wooden frame and glass at front side and hard board at back side.
54Supply,installation of CO2 type fire extinguisher. Capacity. 4.5kg.
55Supply,installation of ABC type fire extinguisher. Capacity. 4kg.
56Supplying and Fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
57Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel/PVC conduit as required 1 run of cable.
58Supply, installation, testing and commissioning of IP Camera Indoor 4MP with RJ 45 connector/jack.
59Supply, installation, testing and commissioning of IP Camera Outdoor 4MP with RJ 45 connector/jack.
60Supply, installation, testing and commissioning of NVR 32 channel complete with all respect accessories and suitable for minimum 8 slot harddisk.
61Supply, installation, testing and commissioning of hard disk 4TB per NVR.
62Supply, installation, testing and commissioning of Switch 16 port POE.
63Supply, installation, testing and commissioning of Switch 24 port POE.
64Supply, installation, testing and commissioning of Back Box.
65Supply, installation, testing and commissioning of 48\\" LED Screen for Observation and reviewing.
66Supply and fixing of 2 meter patch cord with complete connectors.
67Supply, installation, testing and commissioning of 42U RACK with PDU and respected accessories.
68Supply, installation, testing and commissioning of 9U RACK with PDU and respected accessories. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57582427
AUTHORITY Government Departments
TENDER VALUE 32.10 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited
Work Description Tender for Electrification & Allied Works Of Academic Block-Ii At Dr. A.P.J. Abdul Kalam Institute Of Technology Tanakpur (Uttarakhand)
Basic Detail
Tender No 1754/BRIDCUL/Tender/26 Dated 16.09.2026
Bidding Type Tender
Location
City Champawat
State Uttarakhand
Key Dates
Publish Date 21 Sep 2026
Submission Date 01 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 32.10 Lakhs
Tender Fee 5900
EMD 64000
Exemption Not Available
Document List
593f06e0-30b4-46f8-8117-4979f03dba2b.html
BOQ_118270.xls
sbdtanakpurchampawatf.pdf
Tendernotice_1 (33).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

593f06e0-30b4-46f8-8117-4979f03dba2b.html

xls

BOQ_118270.xls

pdf

sbdtanakpurchampawatf.pdf

pdf

Tendernotice_1 (33).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders