Tender For Addition Alteration To Firing Range At Af Stn Thanjavur.

BOQ

Name of Work:- ADDN / ALTN TO FIRING RANGE AT AF STN THANJAVUR.
Sl. No. Item Description
1Please Enable Macros to View BoQ information
2Taking out damaged / contaminated existing sand /soil of any type and in any position and disposing off the outside MD land to a distance exceeding 5 KMs and not exceeding 8 Kms from the firing range and depositing complete all as specified and as directed.
3M&L good quality sand / soil consisting of composition of 50% of Sand and 50% of dry wood saw dust suitable for firing range etc and depositing the same in layers and maintaining the gradual slope at firing range in any place and in any direction complete all as specified and as directed.
4M&L surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard and dense soil complete all as specified and as directed.
5M&L excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manhole, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and as directed.
6Description all as per srl item No 04 here-in-before but exc 1.5m but n.exc 3.0m complete all as specified and as directed.
7M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
8M& L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed.
9M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
10Description all as per srl item No 8 here-in-before but 6mm to 8mm dia complete all as specified and as directed.
11Description all as per item No 8 here-in-before but 5mm dia and over and including 10mm dia as in stirrups spacers and binders complete all as specified and as directed.
12M&L RCC 1:11/2:3 (using 20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for column etc basement slabs under reamed piles and mass concrete complete all as specified and as directed.
13M&L RCC 1:11/2:3 (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
14M&L RCC 1:11/2:3 (using 20 mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
15M&L RCC 1:11/2:3 (using 20 mm graded stone aggregate) as in chajjas complete all as specified and as directed.
16M&L RCC 1:11/2:3 (using 20 mm graded stone aggregate) as in beams, cantilvers, bressummers, lintels over 1.5m span complete all as specified and as directed.
17Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work flat rough finished vertical or to batter complete all as specified and as directed.
18Use and waste of form work to sides of pillars posts, struts, piers, columns and stanchions finished the surface rough square or rectangle shape complete all as specified and as directed.
19Use and waste of form work to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc. rough finished flat complete all as specified and as directed.
20Use and waste of form work to chajjas, troughs and similar items including edges for flat rough finished complete all as specified and as directed.
21M&L form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) rough finished surface of concrete, flat complete all as specified and as directed.
22Supply only water proofing compound complete all as specified and as directed.
23S&F framed work as in door or gates of angle or other section with gusset plate, rails, braces, etc complete drilled for fixing of steel sheeting or other covering. Doors to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing confirming to Fe-410-W (Gde E-250) quality \\"A\\" complete all as specified and as directed.
24S&F framed work such as grills, gratings, etc with ends of bar shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed baluster, walk way, railings, frame work of water tank hung as gates, including pintle hinges, stops, hand made sliding bolts etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and as directed.
25S&F mild steel, plain, black sheet 1.25mm thick rolling shutters and wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nail or rivets and fixed to wood or steel framing with plain 40mm lap joints with rivetted or welded seams, including welding or turning up, mitered angles etc as required complete all as specified and as directed.
26M&L preparation of new surfaces of steel and iron of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed
27M&L Steel windows/ventilators with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including fixing of 3mm thick sheet glass complete all as specified and as directed
28M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
29M&L hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
30M&L 40 mm thick PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen at 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm including 150 micron thick polythene film complete all as specified and as directed.
31M&L PCC 1:4:8 type D-2 (using 40.mm graded stone aggregate) 100 mm thick as in sub base of floor complete all as specified and as directed.
32M&L 100 mm thick PCC 1:2:4 type B-2, (using 40 mm graded stone aggregate) as in flooring and finishing the surface even and smooth without using extra cement including spike rolling or making impressions of expanded metal whilst concrete is green complete all as specified and as directed.
33M&L 75mm thick PCC in 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection/path finished the surface even and smooth without using extra cement complete all as specified and as directed.
34M&L plastering 15mm thick in CM 1:6 on brick or stone walls to be finished even and smooth (without using extra lime or cement) all as specified and as directed .
35M & L rendering 15mm thick on cement mortar 1:4 mixed with water proofing compound @ 3% of weight of cement on brick or concrete work finished the surface even and smooth without using extra cement.. WPC will be measured and paid separately complete all as specified and as directed.
36M&L cement plaster 5mm thick in CM 1:3 on concrete surface on ceilling finished even and smooth with out using extra cement complete all as specified and as directed.
37M & L preparation of new plastered/concrete surfaces of walls, providing one or more coats of Birla white wall care putty to achieve smooth surfaces and applying two coats of distemper oil emulsion of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed.
38M & L preparation of new surfaces of ceiling (plastered or unplastered) and cornices, by brooming down , scrapping down smoke soot, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of white wash on walls complete all as specified and as directed.
39Material and Labour for Prepration of surface and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and as directed.
40M&L Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following complete all as specified and as directed : - (a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 1.50 kg/Sqm on top of dry surface of finished cement mortar plaster. (b) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces.(c) One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non woven fabric shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame.(d) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over polymeric membrane.(e) Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm.
41Returning filling in incl spreading levelling watering and well ramming in layers n.exec 25cm of any type of soil complete all as specified and as directed.
42Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed at a level n.exec 1.5m above the starting point of any type complete all as specified and as directed.
43M&L high density ballistic rubber tiles of 100mm thickness and size 500mmx500mm of each panel made from crumb rubber granuals with polyurathelne polymerically bonded having hardness A60 (ASTM D2240), Tensile Str (Mpa) 1.2(Force 55.4N), Elongation at break 47% (ASTM D573) Tear Str (N/mm) 40.1% Starin @ Break % Specific Gravity (g/cm3) 0.88 and operating (continuous use- 140-150) fixed over AR500 Steel plate packing by the manufactures instructions complete all as specified and as directed. The AR 500 steel plate packing shall be fixed in 500mmx500mm grid and the AR Steel plate shall have two coats of Anti corrosive epoxy painting. The rubber ballistic tiles shall be interlocked with each other to enable to remove defective one whenvever required. The Brinel hardness of AR 500 steel plate should be in the range of 500BHN-600BHN. The following working procedure shall be followed :-Drill and screw the AR500 steel into the cement wall structure.Create vertical hardox square steel pipes with 2x2 inch or other dimensions based on your needs. The steel and tiles must have a 20mm/25mm gap to collect bullet anti-ricochet leads on the floor, which aids in cleaning the range.Begin by screwing the ballistic rubber tiles into hardox square steel pipes. It is preferable to begin affixing the rubber tiles from the ground level, so that they can form supports for one another.
44S&F 1000 Ltr capacity rotational moulded polyethyene water storage tanks (Cylindrical vertical with closed top) twisted and fixed in position complete all as specified and as directed.
45Supply and fix in repairs 20mm unplasticised PVC pipes of pressure rating 10kg/sqcm fixed to walls or laid in floors, complete all as specified and as directed.
46Supply and fix 25 mm unplasticised PVC pipes of pressure rating 10kg\sqcm fixed to walls or laid in floors e, complete all as specified and as directed.
47Supply and fix 20 mm dia ball valves brass high pressure with polythene float and fly nut, complete all as specified and as directed.
48S&F in repairs vitreous china wash basin, white flat back, size 550 X 400 mm fixed to wall by anchor bolts excluding taps, waste coupling, waste pipe etc complete all as specified and as directed.
49S&F in repair PVC low level flushing cistern 10 Ltr capacity incl float valve and flush pipe complete all as specified and as directed.
50S&Fin repairs fancy type pillar taps cast copper alloy, with capstan head, chromium plated, screwed down , high pressure, with or without lettered 'Hot' or Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and as directed.
51S&F in repairs PVC inlet connections 60 cm long, 15 mm bore with PTMT nuts complete all as specified and as directed.
52Taking down chowkats or frames not exc 1.5 sqm with shutter(without taking of shutter from the frames) including hold fasts and PCC block complete all as specified and as directed.
53S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails . MS frame shall be covered with heat moulded plain colour PVC 'C\\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail & bottom rail on either side & as gap insert for top rail & bottom rail , panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement ,supplying & fixing in the frame at site complete all as specified and as directed.
54S&F solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube supplying & fixing in opening complete all as specified and as directed.
55S&F in repairs Half stall Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automaticflushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and as directed. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) and incuding Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)
56Demolition of reinforced cement concrete target base of any description specially provided for and any shape including removing the same from the site complete all as specified and as directed.
57Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in Soft / loose soil complete all as specified and as directed.
58Removing excavated material (soil) not exc 50 m and depositing where directed at the level not exc 1.5 m above the starting point complete all as specified and as directed.
59M&L precast Cement concrete machine pressed coloured interlocking block 60mm thick M-35 (as per sample approved), Joint and pointed in neat cement slurry with gery cement and no pigment as in floors complete all as specified and as directed.
60M&L for 30 mm thick sand filling in bedding layer for laying floor finishes complete all as specified and as directed.
61M&L Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed.
62M&L Plain Cement Concrete 1:3:6, type C1 (using 20 mm graded stone aggregates) for coping over brick walls including necessary use and waste of form work complete all as specified and as directed.
63M&L Pre-cast RCC slabs for covers over drains using 20mm graded stone aggregate 1:2:4, type B1 set in cement mortar 1:4 including necessary form work complete all as specified and as directed.
64M&L cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate as in surface channels and drains including necessary form work complete all as specified and as directed.
65M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred /stopped ends etc complete all as specified and directed.

AI Tender Summary

OUR REF NO 57580297
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35.39 Lakhs
LAST DATE 02-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Addition Alteration To Firing Range At Af Stn Thanjavur.
Basic Detail
Tender No 8260/E8
Bidding Type Tender
Location
City Thanjavur
State Tamil Nadu
Key Dates
Publish Date 18 Sep 2026
Submission Date 02 Oct 2026
Open Date 08 Oct 2026
Finance
Tender Value 35.39 Lakhs
Tender Fee 500
EMD 71000
Exemption Available
Document List
147bc012-137c-4b5c-837e-3157c9117949.html
BOQ_885599.xls
TenderDocuments8260.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

147bc012-137c-4b5c-837e-3157c9117949.html

xls

BOQ_885599.xls

pdf

TenderDocuments8260.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders