Tender For Repair Maintenance To Internal Electrification For Wiring And Fixtures Dbs/Mcbs Etc At Pope Road, Victoria Road, Vishwamitra Marg, Nehru Marg, Scsr, Asha School, Aps, 101 Ta, Shivaji Marg And Other Various Nearby Locations In The Area Of A
Tender Overview
Project Description
Tender for Repair Maintenance To Internal Electrification For Wiring And Fixtures Dbs/Mcbs Etc At Pope Road, Victoria Road, Vishwamitra Marg, Nehru Marg, Scsr, Asha School, Aps, 101 Ta, Shivaji Marg And Other Various Nearby Locations In The Area Of Age E/M Under Ge (North) Pune
BOQ
| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fitting fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, ceiling etc complete all as specified and as directed. |
| 2 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-(Make- Finolex/ Anchor/ Polycab/L&T/ Great White or Techno commercially equivalent in approved makes.) |
| 3 | (a) One light / fan controlled by one switch one way. |
| 4 | (b) One light point controlled by two 2 way switch. |
| 5 | (c) Socket outlet 05 Amp on same board. |
| 6 | (d) Socket outlet 05 Amp on independent board. |
| 7 | (e) One bell / buzzer point controlled by one bell push |
| 8 | All as per item No 02 point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board. |
| 9 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Make- Finolex/ Anchor/ Polycab/L&T/ Great Whiteor Techno commercially equivalent in approved makes) |
| 10 | (a) One ligh/Fant point controlled by one, one way switch |
| 11 | (b) One light point controlled by two 2 way switch. |
| 12 | (c) One three pin 5 Amps socket outlet point controlled by one, one way switch on same board |
| 13 | (d) One 3 pin 5 Amps socket outlet point controlled by one No, way switch on independent board. |
| 14 | (e) One bell / buzzer point controlled by one bell push |
| 15 | All as per item No 4 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board. |
| 16 | Taking down old / perished sub main wiring of any size aluminium conductor cable along with TW batten / PVC conduit and making good the disturbed surface of wall / ceiling complete all as specified and as directed. |
| 17 | M & L in repair for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH Cable with multistranded copper conductor of size 4.0 Sq mm nominal area and drawn through PVC non metallic rigid PVC casing caping and its accessories including one run of PVC insulated 4.0 Sq mm (nominal area) multistranded copper conductor FRLSH Cable as earth wire and connected from DB to DB/ main board complete all as specified and as directed.(Note- Two runs of 4.0 Sqmm main cable, one run of 4.0 Sqmm earth conductor and one run of PVC conduit will be measured as one unit) |
| 18 | All as per item No 7 but Submain wiring with 2 runs of 6 Sqmm size main cable and one run of 6 Sqmm size earth continuity conductor. |
| 19 | All as per item No 7 but Submain wiring with 4 runs of 6 Sqmm size main cable and one run of 6 Sqmm size earth continuity conductor. |
| 20 | All as per item No 7 but Submain wiring with 4 runs of 10 Sqmm size main cable and one run of 10 Sqmm size earth continuity conductor. |
| 21 | Supply and fix for metal flush box made of GI sheet with earth terminal including necessary cutting in wall and POP work as required for matching existing slot in wall complete all as specified and as directed for the following modual metal flush box |
| 22 | (a) Metal Flush box 1 Module |
| 23 | (g) Metal Flush box 2 Module |
| 24 | (b) Metal Flush box 3 Module |
| 25 | (c) Metal Flush box 4 Module |
| 26 | (d) Metal Flush box 6 Module |
| 27 | (e) Metal Flush box 8 Module |
| 28 | (f) Metal Flush box 12 Module |
| 29 | Supply and fix for modular plates white colour with frame of following module complete all as specified and as directed. |
| 30 | (a) 1 Module |
| 31 | (b) 2 Module |
| 32 | (b) 3 Module |
| 33 | (c) 4 Module |
| 34 | (d) 6 Module |
| 35 | (e) 8 Module |
| 36 | (f) 12 Module |
| 37 | S&F for readymade surface mounted PVC box with modular cover plate and frame all ISI marked suitable for holding modular switch socket & regulators for the following module:- |
| 38 | (a) 1 module |
| 39 | (b) 2 module |
| 40 | (c) 3 Module |
| 41 | (d) 4 Module |
| 42 | (e) 6 Module |
| 43 | (f) 8 Module |
| 44 | (g) 12 Module |
| 45 | S&F modular switch 01 way 6 Amp , 01 module ISI marked complete all as specified and as directed.(Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 46 | S&F modular switch 02 way 6 Amp , 01 module ISI marked complete all as specified and as directed.(Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 47 | S&F modular switch 01 way 16 Amp , 01 module ISI marked complete all as specified and as directed.(Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 48 | M&L for Modular bell push 6 amp 230 volt 50 hz AC supply one way, complete all as specified and as directed.(Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 49 | S&F modular socket 6 Amp , 2 module ISI marked complete all as specified and as directed.(Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 50 | S&F modular socket 6 / 16 Amp , 02 in 01 , 02 module ISI marked complete all as specified and as directed.(Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 51 | S&F for modular step fan regulator 120 watt 2 module suitable for 230 Volt 50 Hz supply complete all as specified and as directed. |
| 52 | Supply & fix CALL Bell ISI marked complete all as specified and as directed.(Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 53 | S&F ceiling rose surface Bakelite 3 terminals 230V 50 Hz ISI marked complete all as specified and as directed. (Make:Anchor/Roma/Havells/Legrand/Indoasian/Greatwhite) |
| 54 | S&F for Lamp holder, PVC/ Polycarbonate type with back plate suitable for angle/batten fitting complete all as specified and as directed. |
| 55 | S & F in repair for LED 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make- Bajaj Cat Part No BCLSB 10 NW, or its equivallent model in JAQUAR Cat LGLZ01X010XC, HAVELLS, PHILIPS /Greatwhite |
| 56 | S & F for wall/ceiling mounted LED batten tube 18 watts white/ warm white light fitting, 230 volts with out put of 2000 lumens with extruded aluminium housing with decorative end caps and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18 watts complete all as specified and as directed. Make :- JAQUAR Cat part No-LGLZ01X020XN or PHILIPS, Bajaj, Havells, Greatwhite |
| 57 | S & F in repair for wall mounted 18 watts indoor Inverter batten with opal diffuser, IP 20, with 4 hrs back up with out put of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18 watts complete all as specified and as directed. Make :- Halonix Cat part No. LED INVERTER BATTEN HLB-08-18-CW-INV or Techno commercially equivalent in approved makes. Philips |
| 58 | Supply and fix for energy saving new generation 10 watts LED bulk head fitting , 230 volts with connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor from ceiling rose to fitting complete all as specified and as directed. Make :- PHILIPS/JAQUAR Cat LBLK02X010XC 10W/Bajaj/Shakti/ havells or Techno commercially equivalent in approved makes. |
| 59 | S & F in repair LED post top lantern fitting New generation, energy saving, environmental friendly, long life aesthetically designed Die cast aluminium housing of capacity 25 Watt, with high power LED as light source complete with all accessories fixed on GI pipe 40mm dia complete all as specified and directed. Make : Bajaj Cat part No BGCTN 25W LED WW, JAQUAR /Shakti Cat No SZPGPMX025/ Havellsor Techno commercially equivalent in approved makes. |
| 60 | Supply & fix in replacement for Decorative wall mounted luminaire with opal glass with E27 lamp holder complete all as specified and as directed. Make- Jaquar Cat part No - JNL-CHR-WLSL-55004E27 , havells FLORETTE 1LS E27 SS or Techno commercially equivalent in approved makes. |
| 61 | Supply and fix in repair Inverter LED Lamp warm white/ amber 10 Watt highly efficient of make Halonix LED INVERTER LIGHT 10W B22 CW IP, Havells /Bajaj/Philips all as specified and as directed. |
| 62 | S & F in repair for recess mounted 2' x 2' luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free sift illumination square LED panel 36 watts, white/Warm White powder coated CRCA housing with full window acrylic diffuser giving a complete full glow look, operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- JAQUAR Ultima Ultra Cat Part No LULTU1S036XC or its Techno commercially equivalent in approved makes. in Havells/ Phillips/Bajaj-BZRSQL 36L LED GX WH, Greatwhite or Techno commercially equivalent in approved makes. |
| 63 | S & F in Repair for LED down light recess mounted luminare, 1'x4'of 36 watts with efficiency of 100 lumens per watt, sleek design aluminium housing polycarbonate diffuser white finish operating voltage 150 V-270 V AC, 50 Hz all as per Make- Bajaj Cat BZRSLL 36L LED or jaquar/ Havells, Phillips or Techno commercially equivalent in approved makes. |
| 64 | S & F in Repair for LED downlight recess mounted luminare Square type 15 watts with inbult driver and polycarbonate opal diffuser white finish operating voltage 230V AC, 50 Hz including taking down old unserviceable fitting complete all as specified and as directed. Make :- Jaquar-IDL-WHT-LLCN01S015XC, philips/ Havells , Greatwhite or Techno commercially equivalent in approved makes. |
| 65 | S & F in Repair for LED downlight recess mounted luminare round type 18 watts with inbult driver and polycarbonate opal diffuser white finish operating voltage 230V AC, 50 Hz including taking down old unserviceable fitting complete all as directed Make :- Jaquar IDL-WHT-LLCN01R018XC, philips/ Havells , Greatwhite or Techno commercially equivalent in approved makes. |
| 66 | S & F in Repair for LED downlight recess mounted luminare round type 12 watts with inbult driver and polycarbonate opal diffuser white finish operating voltage 230V AC, 50 Hz including taking down old unserviceable fitting complete all as directed Make :- Jaquar IDL-WHT-LLCN01R012XC, philips/ Havells , Greatwhite or Techno commercially equivalent in approved makes. |
| 67 | S & F in Repair for LED downlight surface mounted luminare round type 12 watts with inbult driver and polycarbonate opal diffuser white finish operating voltage 230V AC, 50 Hz including taking down old unserviceable fitting complete all as directed Make :- Jaquar IDL-WHT-LNRO02R012SC , philips/ Havells , Greatwhite in Techno commercially equivalent in approved makes. |
| 68 | S & F in repair wall mounted LED 3/6 watts bed side lamp with necessary electrical connections complete all as specified and as directed of Make Jaquor cat Part No WBR-CHR-LBED01R003XW Techno commercially equivalent in approved makes. in Havells/Bajaj/Crompton, Phillips or Techno commercially equivalent in approved makes. |
| 69 | S & F in repair wall mounted LED 3/6 watts PICTURE Light flexible and adjustable to any direction with necessary electrical connections complete all as specified and as directed. Make: Philips, Havells, Jaguar, lukar or Techno commercially equivalent in approved makes. |
| 70 | S/F LED street light fitting 30 Watt 230V energy efficient & environment friendly type. The fitting should have powder coated, pressure die cast Aluminium housing and heat resistant toughened glass with frame having better optics for uniform distribution complete all as per Make JAQUAR OSL-GRY-LSRT015030XC or Techno commercially equivalent in approved makes. of make Bajaj, Philips, Havells , Greatwhite as approved. |
| 71 | Supply and fix in repair for Ceiling Fan of sweep size 1200 mm BEE. Five star rated with brushless direct current motor (BLDC) →, ISI marked and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. Make:- Bajaj , USHA , Havells, Orient or Techno commercially equivalent in approved makes. |
| 72 | Supply and fix in repair for plastic body exhaust fan, AC single phase, 240 volts of size 150 mm sweep with louvers all as per Cat No. Maxma DX 6\\" of Make Bajaj or Techno commercially equivalent in approved makes. of Make Automberg/ Havells/Usha/ Halonix with necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and as directed. |
| 73 | Supply and fix in repair for plastic body exhaust fan, AC single phase, 240 volts of size 200 mm sweep with louvers all as per Cat No. Maxma DX 8\\" of Make Bajaj or Techno commercially equivalent in approved makes. of Automberg/ Havells/Usha/ Halonix with necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and as directed. |
| 74 | Supply and fix in repair for plastic body exhaust fan, AC single phase, 240 volts of size 250 mm sweep with louvers all as per Cat No. Maxma DX 10\\" of Make Bajaj or Techno commercially equivalent in approved makes. of Automberg/ Havells/Usha/ Halonix with necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and as directed. |
| 75 | Supply and fix in repair for metal body exhaust fan, AC single phase, 240 volts of size 300 mm sweep of Make Bajaj Bahar or Techno commercially equivalent in approved makes. of Havells/Usha with necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 76 | Supply and fix in repair for metal body exhaust fan, AC single phase, 240 volts of size 300 mm sweep of Make Bajaj Bahar or Techno commercially equivalent in approved makes. of Havells/Usha with necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender