Tender For Repairs To Internal Wiring, Submain Wiring, Led Fittings, Fans, Geysers, Summer Cooling Appliances, Dg Sets And Certain Allied E/M Works At Mil Station Bhusawal Under Ge (S) Ahilyanagar
Tender Value
28 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
4 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalgaon → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Internal Wiring, Submain Wiring, Led Fittings, Fans, Geysers, Summer Cooling Appliances, Dg Sets And Certain Allied E/M Works At Mil Station Bhusawal Under Ge (S) Ahilyanagar
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, bell push, holders, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed. |
| 2 | M & L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC boards for mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch.NOTE : 1. Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. Wiring shall be done as per complaints received from user only on reqired basis it is not necessary to do whole wiring of any whole bldg. 3. All points shall be earthed upto lights fittings, fans,bldg security lights etc. |
| 3 | All as per serial item No. 2 here in before but for one 6 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. |
| 4 | All as per serial item No. 2 here in before but for one 6 Amp 5 pin socket outlet point on independent board. |
| 5 | All as per serial item No. 2 here in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 6 | All as per serial item No. 2 here in before but for one light point controlled by two 2-way switches |
| 7 | All as per serial item No. 2 herein before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase,Neutral and earth for one 16 Amp, 6 pin socket on independent board. |
| 8 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade, conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable laid / fixed and including concealed PVC rigid conduit on walls/ceiling alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including including Sunken box, including PVC boards/bakelite sheets / and including factory made terminal boxes with modular cover plates and frames suitable for mounting switches, sockets, fan Regulators, accessories etc as specified and as directed for one light point or one fan point controlled by one, one way switch NOTE :- 1.Proper colour coding shall be adopted for wiring (for phase-RED, YELLOW, BLUE for Earth-Green and Neutral-Black) 2.wiring shall be done as per complaints received from user only on reqired basis it is not necessary to do whole wiring of any whole bldg. 3. All points shall be earthed up to fixtures i.e holdrs,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc.4. Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall ,floors etc. |
| 9 | All as per serial item No. 8 here-in-before but for one 6 Amp, 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 10 | All as per serial item No. 8 here-in-before but for one 6 Amp, 3 pin socket outlet point on independent board with other switches including earth wire as specified. |
| 11 | All as per serial item No. 8 here-in-before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 12 | All as per serial item No. 8 here in before but for one light point controlled by two 2-way switches |
| 13 | All as per serial item No. 8 here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth for one 16 Amp, 6 pin socket on independent board. |
| 14 | S&F switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish, all as specified & as directed. |
| 15 | S&F switch socket combination, flush type, 5 pin, 6 Amp, multipurpose, 230 volts, suitable for 3 pin/2pin 6 Amp plug top white/ivory finish all as specified & as directed. |
| 16 | S&F switch socket combination, multipurpose, flush type, 2 in 1 type (6 pin) 6/16 Amps, 230V, AC. all as specified & as directed. |
| 17 | S&F lamp holder, angle/ batten type, PVC/Polycarbonate type with back plate, suitable for batten fittings all as specified & as directed. |
| 18 | S&F lamp LED 5 Watt, 230 volts 50 Hz AC complete all as specified and as directed.Make : Cat No. LHLDDDEC1D2R005 of Havells or equivalent of makes specified. |
| 19 | S&F ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & as directed. |
| 20 | S&F bell push, flush type, 6 Amp, single pole, 230 volts, white finish all as specified & as directed. |
| 21 | S&F fan regulator, step type, electronic on existing phenolic laminated sheet, 5 step, socket type, 230 volts, 120 watts, suitable for ceiling fan 1200/1400mm sweep all as specified & as directed. |
| 22 | S&F bell, AC, 230 volts, single phase complete all as specified and as directed. |
| 23 | S&F switch piano, flush button, 6 Amp, single pole, two way, 230 volts, white finish, all as specified & as directed. |
| 24 | S&F in repairs Inverter LED batten 20W 6500K with square profile and polycarbonate channel, lithium-Ion battery with charging time 8hours-10 hours, back up time up to 4 hours and surge protection up to 4KV.Make : HAVELLS PRIDE PLUS INVERTER BATTEN Cat No. LHEXASP7IN1W020 or equivalent model of makes specified. |
| 25 | S & F square profile LED lighting fixture with extruded polycorbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitting 10 Watt with LED light source 6500k with uniform light output,with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with complete with all as specified and directed by Engineer-in-charge.Make:HAVELLS E-LITE LED PRIDE PLUS NEO Cat No LHEXACP5IN1W010 or equivalent model of makes specified in PS. |
| 26 | S&F in repairs, 210 mm x 210 mm size, flat panel square fixture, slim,compact, aluminium die cast lit panel, recess mounting 1 x 18 watt, 230 volt with opal diffuser and sepatate electronic driver, LED light source 6500K with uniform light output, with all accessories including tconnections from ceiling rose to light fittings complete all as specified & as directed. Make :- Havells Cat Part No OCTANE LED PANEL SQUARE Item Code LHEBAEP7IZ1W018 or equivalent model of makes specified in PS. |
| 27 | M & L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTE: 1. Proper colour coding shall adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. Three runs of 4 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 28 | M & L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTE: 1. Proper colour coding shall adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. Three runs of 6 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 29 | S&F in repairs, sheet metal enclosures with plug socket, single pole and neutral with two pin and earth plug and Top with one MCB of 20 Amps (SP) complete all as specified and as directed. |
| 30 | S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'c' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. |
| 31 | S&F in repairs, MCB SPN, AC 240 V, 6 to 32 Amps, 10 KA capacity, 'c' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. |
| 32 | S&F in repairs, sheet metal enclosure (Factory made), double door MCB DB distribution board (when MCBs are to be used), SPN 240 volts, 8 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming as per IEC 61439-3, suitable for flush mounting and surface mounting, with 200 Amps rated copper bus bar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 33 | S&F in repairs, sheet metal enclosure (Factory made), double door MCB DB distribution board (when MCBs are to be used), SPN 240 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 200 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 34 | S&F in repairs, sheet metal enclosure (Factory made), double door MCB DB distribution board (when MCBs are to be used), TPN 415 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 200 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 35 | S&F in repairs ISOLATOR TPN, AC 415 V, 63 amps, 10 KA capacity ,'C' series, making connection with suitabl size of copper lugs etc complete all as specified and as directed. |
| 36 | S&F in repairs, security/street light fitting of building with single piece new generation energy savng and environmental friendly, long life, LED 35 W, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07 including one bracket made of light grade GI Pipe 25 mm dia, fixed to wall/ pole with two clamps made out of mild steel flat iron 40 mm x 5 mm and connect to nearest electric supply by two core 1.5 sqmm aluminium cable all as specified and as directed. Make : Havells Cat No ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC or equivalent model of makes specified. |
| 37 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia , by means of nut bolts, check nuts and washer of the GI Earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. |
| 38 | S&F in replacement 1100 Volt grade, heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection with twin core cable flat of stranded multistranded aluminium conductor of size 6 Sqmm suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one complete all as specified and as directed. |
| 39 | S&F in replacement 1100 Volt grade, heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection with twin core cable flat of stranded multistranded aluminium conductor of size 4 Sqmm suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one complete all as specified and as directed. |
| 40 | S&F in replacement 1100 Volt grade, heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection with twin core cable flat of stranded multistranded aluminium conductor of size 2.5 Sqmm suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one complete all as specified and as directed. |
| 41 | Supply and fix in replacement 15 watt post top lantern new generation, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and IP-65 protection complete all as specified and as directed.Make : Havells CORALPT15W757PSYMTOPC, or equivalent model of makes specified in PS. |
| 42 | S & F gate light made up of high grade unbreakable polycarbonate material suitable for retrofit 1x7 W LED Lamp (B22 base) - Moon 150 complete all as specified and as directed.Make:Havells MOON (OPAL) Cat no LHFXBONITN5Q008 or equivalent model of makes specified in PS. |
| 43 | S & F gate light made up of high grade unbreakable polycarbonate material suitable for retrofit 1x20 W LED Lamp (B22 base) - Moon (PRISMAT IC) complete all as specified and as directed.Make:Havells MOON (OPAL) Cat no LHFXBONITN5Q014 or equivalent model of makes specified in PS. Please Enable Macros to View BoQ information |
| 44 | S & F gate light made up of high grade unbreakable polycarbonate material suitable for retrofit 1x20 W LED Lamp (B22 base) - Moon (PRISMAT IC) complete all as specified and as directed.Make:Havells MOON (OPAL) Cat no LHFXBONITN5Q014 or equivalent model of makes specified in PS. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender