| Sl. No. | Item Description |
| 1 | Taking down carefully copper/alluminium point wiring light, fan, sockets or power including all fittings and accessories complete and making good disturbed surface of walls and floors etc. |
| 2 | M&L for Point wiring complete with and including 1.5 sq. mm (nominal area) single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade ISI marked drawn through in and including concealed non metalic rigid PVC conduit with accessories such as bend ,tees, junction boxes etc. suitable modular boxes for mounting fittings like modular switches, modular sockets and fan regulators etc with modular sheet covers including one run of 1.5 Sqmm PVC insulated and unsheathed multi strand FRLS copper conductor as green colour earth wire and connected to common earth dully complete all as specified and directed for the following:- |
| 3 | One light/fan/bell point controlled by one switch |
| 4 | One 3 pin socket outlet 5A on independent board |
| 5 | One 3 pin socket outlet 5A only on same board. |
| 6 | All as per item 2 above but with 2.5 sq mm size pvc insulated and unsheathed 1100 volts grade single core stranded multistrand ) copper conductor cable for 3/6 pin socket outlet 15 amp on one independent board. |
| 7 | S&F Modular Switch one way 6 Amps, 1 module all as specified and directed. |
| 8 | S&F Modular Socket 2 module for 2 / 3 pin 6 Amp all as specified and directed. |
| 9 | S&F Modular Switch one way 16 Amps, 1 module all as specified and directed. |
| 10 | S&F in repairs Modular bell push, flush type, 5 amp |
| 11 | S&F Socket 2 module 2in1, 3 pin, 6 and 16 Amp, complete all as specified and directed . |
| 12 | S&F ceiling rose PVC / polycorbonate isolated body 3 terminals with base plate ISI marked including taking down old unserviceable ceiling rose complete all as specified and directed.. |
| 13 | S&F Modular Electronic fan regulator 120W including taking down old unserviceable fan regulator complete all as specified and directed. |
| 14 | S&F lamp holder, PVC/poly carbonate type with back plate suitable for batten fittings complete including taking down unserviceable lamp holder all as directed by Engineer-in-Charge. |
| 15 | S&F Ding Dong bell AC 230 V complete unservicabal including taking down unservicable bell complete all as directed by Engr-in-Charge |
| 16 | S&F plug top 16 Amps,3 pin 230 V complete unservicabal including taking down unservicable plog top complete all as directed by Engr-in-Charge |
| 17 | S&F plog top 6 Amps,3 pin 230 V complete unservicabal including taking down unservicable plog top complete all as directed by Engr-in-Charge |
| 18 | S&F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <=20W, luminaire lumen >2000 lm, system efficiency of > 100 lumens/W, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Wipro/ Havells/ Philips/Bajaj |
| 19 | S&F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <=10W, luminaire lumen >2000 lm, system efficiency of > 100 lumens/W, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) including taking down old unserviceable light fitting of any description complete all as specified and directed.Make:- Wipro/ Havells/ Philips/Bajaj |
| 20 | Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.Make :Philips, Cat No : 30575 (Comet) or equivalent in Havells, Cat No : LHDL06160099 (CITY 3). |
| 21 | Supply and fix in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into existing T8 conventional fluorescent tube light fitting after changing the necessary electric connections as required at site complete all as specified and directed. |
| 22 | S&F LED bulb of zero watts red and green colour complete incl taking down old bulbs |
| 23 | Supply only LED bulb 9 Watts suitable for B22 white in colour all as specified and directed. Make:- Havells/Crompton/Philips/Bajaj/Surya |
| 24 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 25 | S&F 2 ft x 2ft recess mounted full panel LED luminaire with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaire lumen > 3500lm and system efficiency >120lm/W, CRI>80, colour temp -5700K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) , range 150-270V AC and safety extra low voltage safe level <60V DC including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Havells/Philips/Wipro/Bajaj |
| 26 | S&F 2 ft x 2ft recess mounted full panel LED luminaire ( Warm White) with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaire lumen > 3500lm and system efficiency >120lm/W, CRI>80, colour temp -3000K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) , range 150-270V AC and safety extra low voltage safe level <60V DC including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Havells/Philips/Wipro/Bajaj |
| 27 | S&F full glow, 1' x 4' (4 ft) LED luminaire, 36 W glare free and provision of cable from ceiling rose to light fitting including taking down unserviceable light fitting complete all as directed. Make :- Philips model No. RC380B LED32S-6500 L120W 30 PSU OD or techno equivalent in WIPRO / HAVELLS . |
| 28 | S&F LED post top lantern 35 Watts with symmetric light distribution energy saving, environmental friendly IP65 spun aluminium landscape luminiary with higher power LED as light source. Make:- Havells/Crompton/Philips/Bajaj |
| 29 | S&F LED flood light 250 Watts with aluminium die cast IP 66 with symmetric light distribution energy saving, environmental friendly suitable for high lighting archtechural faced all as specified and directed. Make:- Havells/Crompton/Philips/Bajaj |
| 30 | S&F LED flood light 100 Watts with aluminium die cast IP 66 with symmetric light distribution energy saving, environmental friendly suitable for high lighting archtechural faced all as specified and directed. Make:- Havells/Crompton/Philips/Bajaj |
| 31 | S&F in replacement highly efficient LED down light warm white 15 Watts IP 44 rating,recessed mounted pressure die cast aluminium in powder coated white finish with optimized heat sink for efficient heat dissipation with electrinic driver all as specified and directed. Make:- Havells, Cat No:- ENDURAHODLR15WLED830MOD & LEDDRIVER12/15WENDURAHOCE or equivalent in Crompton/Bajaj/Philips |
| 32 | S&F in replacement highly efficient LED down light warm white 12 Watts IP 44 rating,recessed mounted wall washers, tilted 70 degree outwards and swivels 360 degree, pressure die cast aluminium in powder coated white finish with optimized heat sink for efficient heat dissipation with electrinic driver all as specified and directed. Make:- Havells, Cat No:- SPARKLEPROSNOOTDLR20WLED857MOD38D & LEDDRIVER20WS or equivalent in Crompton/Bajaj/Philips |
| 33 | S&F in replacement LED down light 09 Watts warm white recess mounted adjustable with aluminium housing with electrinic driver all as specified and directed. Make:- Havells, Cat No:- SPARKLEPROADJDLR8W830MOD40D & LEDDRIVER8WS or equivalent in Crompton/Bajaj/Philips |
| 34 | S&F in replacement flexible LED strip uses high brightness yellow colour with electrinic driver all as specified and directed. Make:- Havells, Cat No:- FLEXISTRIP5MTRIP2055WLED860S & FLEXISTRIPDRIVER72WS or equivalent in Crompton/Bajaj/Philips |
| 35 | S&F Surface mounting Metal / PVC flush box 1/2 module 3 module including 3 modules inner plate & outer cover and taking down unserviceable Metal box complete all as directed by Engineer-in-Charge. |
| 36 | S&F Surface mounting Metal / PVC flush box 6 module including 6 modules inner plate & outer cover and taking down unserviceable Metal box complete all as directed by Engineer-in-Charge. |
| 37 | S&F surface mounting Metal / PVC flush box 8 module including 8 module inner plate & outer cover and taking down unserviceable Metal box complete all as directed by Engineer-in-Charge. |
| 38 | Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed |
| 39 | Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed |
| 40 | M&L for double door distribution board made of sheet metal TPN 4 way with 200 Amps rated bus bar with metal door including taking down unserviceable distribution board complete all as directed by Engineer-in-Charge. |
| 41 | S&F 3 pole MCCB 25-100 Amps 50Hz 415 volts with a rapturing capacity 16 KA including taking down unservicable MCCB complete all as directed by Engr-in-Charge |
| 42 | S&F 4 pole MCCB 100 Amps 50Hz 415 volts with a rapturing capacity 16 KA including taking down unservicable MCCB complete all as directed by Engr-in-Charge |
| 43 | S&F 4 pole MCCB 250 Amps 50Hz 415 volts with a rapturing capacity 25 KA including taking down unservicable MCCB complete all as directed by Engr-in-Charge |
| 44 | M&L for MCB TPN 100 Amps 415 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge. |
| 45 | M&L for MCB TPN 63 Amps 415 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge. |
| 46 | M&L for MCB SPN 40 Amps 240 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge. |
| 47 | M&L for MCB SPN 63 Amps 240 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge. |
| 48 | M&L for MCB SP 63 Amps 240 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge. |
| 49 | M&L for MCB SP 06 to 40 Amps 240 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge. |
| 50 | M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 4 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 4 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 V grade and connecting to common earth drawn through and including PVC concealed conduit medium grade ISI mark not less than 25mm outer dia complete and accessories of suitbale size as required. Note : Three run of 4 sqmm cable and one run of conduit shall be measured and paid as one length. |
| 51 | M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 6 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 6 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 V grade and connecting to common earth drawn through and including PVC concealed conduit medium grade ISI mark not less than 25mm outer dia complete and accessories of suitbale size as required. Note : Three run of 6 sqmm cable and one run of conduit shall be measured and paid as one length. |
| 52 | M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 10 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 10 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 V grade and connecting to common earth drawn through and including PVC concealed conduit medium grade ISI mark not less than 25mm outer dia complete and accessories of suitbale size as required. Note : Three run of 10 sqmm cable and one run of conduit shall be measured and paid as one length. |
| 53 | S&F PVC casing /capping of 1\\" width complete including taking down old capping. |
| 54 | S&F PVC casing /capping of 4/3\\" width complete including taking down old capping. |
| 55 | S&F cable 2 core PVC insulated unsheathed multistranded copper conductor of size 1.5 Sq mm in replacement passing through PVC conduit from junction box to fitting incl PVC conduit including taking out old unserviceable cable complete all as directed. |
| 56 | S&F cable 3 core PVC insulated unsheathed multistranded copper conductor of size 2.5 Sq mm in replacement passing through PVC conduit from junction box to fitting incl PVC conduit including taking out old unserviceable cable complete all as directed. |
| 57 | S&F cable 3 core PVC insulated unsheathed multistranded copper conductor of size 4 Sq mm in replacement passing through PVC conduit from junction box to fitting incl PVC conduit including taking out old unserviceable cable complete all as directed. |
| 58 | S & F Replacement of unserviceable wire of size 1.5 Sqmm with PVC insulated FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 1.5 Sqmm . |
| 59 | All as per item No 55 here in before but of size 2.5 Sqmm. |
| 60 | All as per item No 55 here in before but of size 4.0 Sqmm. |
| 61 | All as per item No 55 here in before but of size 6.0 Sqmm . |
| 62 | S&F PVC flat twin core cable with aluminium conductor of size 10 Sq mm including taking out old unserviceable cable complete all as directed. |
| 63 | S&F PVC flat twin core cable with aluminium conductor of size 16 Sq mm including taking out old unserviceable cable complete all as directed. |
| 64 | S&F Hylam sheet of size 8\\"x10\\" complete incl taking down old sheet |
| 65 | S&F Hylam sheet of size 12\\"x10\\" complete incl taking down old sheet |
| 66 | S&F Hylam sheet of size 6\\"x4\\" complete incl taking down old sheet |
| 67 | Supply only Insulation tape roll of width 1.80cm and legnth 7.00m and thickness 0.125mm complete all as directed |
| 68 | M&L for taking down ceiling /exhaust/pedestal/wall mounted fans of different makes and sizes for repairs and installing in its original position after repairs including provision of cable from ceiling rose or connected to fan complete all as directed by Engineer-in-Charge. |
| 69 | M&L for Dismantling of fans for rewinding with super enameled copper wire as per existing gauge /number of turns including heat varnish, overhauling and testing complete all as directed by Engineer-in-Charge for the following sizes: |
| 70 | (a) Ceiling fan 1200 / 1400 mm |
| 71 | (b) Exhaust fan 230 /300 mm |
| 72 | (c) Pedestal/Wall mounted fan 400 mm |
| 73 | S&F following spare parts for ceiling /exhaust fans of different makes and sizes and taking down unserviceable spare parts complete all as directed by Engineer-in-Charge. |
| 74 | (a) Copper Bush |
| 75 | (b) Ball bearing NO.6201 |
| 76 | (c ) Ball bearing No. 6202 |
| 77 | (d) Ball bearing for exhaust fan & pedestal fanMake for item Srl NO. 67 (a) to (d) : SKF/TATA |
| 78 | (e) Condensor 2.5 MFD |
| 79 | (f) Condensor 3.15 MFDMake for item Srl NO. 67 (e) & (f): Universal /Capco |
| 80 | (g) Rubber bush |
| 81 | (h) Canopy |
| 82 | (j) Condensor stand |
| 83 | (k) GI nuts, bolts and washers |
| 84 | (l) Ceiling fan blade 1200 mm. |
| 85 | (m) Exhaust fan blade 230/300 mm |
| 86 | M&L for taking down geysers of different makes and 25/50 ltrs capacity for repairs and installing in its original position after repairs with new bolts, nuts and washers complete all as specified. |
| 87 | M&L for taking out copper inner shell from the geyser 25/50 ltrs capacity of any make, arresting leakage by copper braxing including cleaning , provision of new rock wool and testing complete and refixing all parts in same position complete all as directed by Engineer-in-Charge. |
| 88 | S&F following spare parts for geysers and taking down unserviceable spare parts complete all as directed by Engineer-in-Charge. |
| 89 | Thermostat suitable for geyser 25/50 ltrs capacity. |
| 90 | PVC hose for hot /coldwater 450mm long with brass end nuts (ISI marked) suitable for 15mm dia GI tubing complete. |
| 91 | Heating element 2 KW ( Horizontal/Vartical) |
| 92 | Indicating lamp (Red/Green) |
| 93 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engr-in-Charge. Make:- Bajaj/Havells/Crompton/Usha |
| 94 | Supply and fix exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM ISI marked, and making connection with twisted copper flexibelwire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha |
| 95 | Supply and fix exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 225/230 mm sweep 1400 RPM ISI marked and making connection with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha |
| 96 | Supply and fixing wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1350 RPM, 65 Watts power input, air delivery 65 Cum/min with all accessories complete all as directed by Engineer - in - charge. Make:- Bajaj/Havells/Crompton/Usha |
| 97 | Supply and fix PVC air freshner 200 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha |
| 98 | Supply and fix PVC air freshner 300 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha |
| 99 | Supply and fixing of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 25 Ltr to operate on 230 volt AC, vertical type, white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode, adjustable thermostat, enamel coated incology heating element 2 KW, ABS plastic body including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, complete all as specified and directed. Make: Racold/Jaquar/Havells/Bajaj/Crompton.( Note:- Sl No 76 to 82- U/S fans/Geysers will be handed over to MES E/M Yard for BER procedure) |
| 100 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender