Housing Urban and Rular Development Government Departments Closing in 8 days TDR #57574663

Tender For Emergent Restoration Of 05(Five) Nos Flats By Replacing The Damaged Electrical Wirings Including Modification Of Illumination System At Bichitra And Banasree Abasans To Be Executed By Central Mechanical Division, Slrdc , Under Ud & Ma Depa

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
7.93 Lakhs
Estimated cost
Bid Submission
02 Oct 2026
8 days left
EMD
15873
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Emergent Restoration Of 05(Five) Nos Flats By Replacing The Damaged Electrical Wirings Including Modification Of Illumination System At Bichitra And Banasree Abasans To Be Executed By Central Mechanical Division, Slrdc , Under Ud & Ma Department.

BOQ

Name of Work:- Emergent restoration of 05(Five) nos flats by replacing the damaged electrical wirings including modification of illumination system at Bichitra and Banasree abasans to be executed by Central Mechanical division, SLRDC , under UD & MA Department.
Sl. No. Item Description
1Supplying and fixing Sheet steel Main Switches on flat/ angle iron frame on wall
230/32 A,240V DP with fuse on L&N Standard make
360/63 A,415V TPN with fuse on L&N Standard make
4Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated&unsheathedcopperwire(BrandapprovedbyEIC) of following sizes in25mm PVCcasing-capping (Precision make) incl. necy. PVC clips, fittings etc.
52 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
62 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5 sqmm)
7Distributionwiringin1.1KVgrade2x22/0.3(1.5sqmm)single corestranded'FR' VCinsulated&unsheathedcopperwire (BrandapprovedbyEIC) nsuitablesizePVCcasing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVCinsulated&unsheathedcopperwire for ECC, incl. necy. PVCclips, fittingsetc. to light/fan/call bell point with piano key type witch(Anchormake)fixed on sheet steel fabricatedswitchboardwithPerspex/bakelitetopcover on wall incl. necy. connections and making earthing attachment andmendinggooddamages buildingworks. [PVC casing-capping and Switch board both on surface] Average run 6 mtr.
8Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVCcasing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] On Board
9Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
10Supplying and fixing 20A Piano key type Switch.
11Supplyingandfixingdouble-doorSPNMCBDistribution BoardwithIP-42/43protection,concealedinwallafter cutting the wall &mending good the damages to original finishincl. Interconnectionwithsuitablesizeof copperwireandneutral link&provision for earthing attachment.
122+8 way Enclosure (607711) L &T make
13Supplying and fixing240/415V MCB of Breaking capacity10kA&Ccharacteristics on din rail of existing DBs and necessary connection L&T make 6-32 A.
14Supplyingand fixing240/415VMCB Isolator on din rail of existing DBs and necessary connection. 40 A .L&T make .
15Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
16Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GIModular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc..
17Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
1825mm size
19Disconnection & dismantling the existing damged wiring with switch boards, luminaries & fans etc. before stating the civils works or as per direction of EIC
201 no Electricain=Rs 491.00/Day with 02 nos helper for electrician=2 x 447=894/ day= Rs 1385 day
21SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. (Rate in Rs. Per Mtr)
224 CORE 10 SQ MM
232 CORE 6 SQ MM
24Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
25Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed,
26Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required, 50 mm dia.
27Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below ,
284 CORE 10 SQ MM
292 CORE 6 SQ MM
30Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials,
314 CORE 10 SQ MM
322 CORE 6 SQ MM
33Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 bars,415 V, 100/125 ADimension of Al. bars [85mm long] 4 x 25x5mm,Dimension of Sheet Metal Box 500x150mm
34S & F of Sintex SMC/ FRP water proof type looping cable box on newly erected pole size 240 x 130 x 95 mm depth having hinged front cover & Kit Kat fuse unit one no. N.L. on insulator, 1 no. 4-way bakelite connector for 2 nos. compression brass gland for up to 3-core 16 sq mm PVC/ Al. cable and having lined with rubber gasket front cover with brass machine screw etc. earthing terminal with lug on steel tubuler pole near base including supply & fixing of clamps with bolts & nuts etc. complete in all respect as per direction of E.I.C.
35Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980} 7m length, 73Kg, 410-SP-02make Calcutta poles & Tubes Co./ any approved make.
36Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly,
37Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
38Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box.
39Supply of single arm bracket made of 40mm dia 1.0 meter long.
40Supply of double arm bracket made of 40mm dia 1.0 meter long
41Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint, Upto 9.0 mtr. long pole
42One coat of red lead/Zinc chromate priming
431st coat of synthetic enamel paint over the primer
442nd coat of synthetic enamel paint over the 1st coat
45Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC)of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 22/0.3 (1.5 sqmm)
46Supply and fixing of greenline V2 street light (115 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make: Philips, 115watt
47Excavation of soil for installation of Earth Electrode and filling & ramming ,
48For Morrum Soil
49Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below,
50By ISI-Medium GI pipe
51Connecting the equipments to earthbus bar including S&FGI HotDip)wireofsizeasbelowonwall/floorwithstaplesburied inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No 4 SWG .
52GST@18% on total amount
53CESS@1% on total amount Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57574663
AUTHORITY Government Departments
TENDER VALUE 7.93 Lakhs
LAST DATE 02-10-2026
Authority
Authority Name Urban Development Department
Work Description Tender for Emergent Restoration Of 05(Five) Nos Flats By Replacing The Damaged Electrical Wirings Including Modification Of Illumination System At Bichitra And Banasree Abasans To Be Executed By Central Mechanical Division, Slrdc , Under Ud & Ma Department.
Basic Detail
Tender No WBUDMA/EE/CMD/e-NIT-13/2026-27
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 18 Sep 2026
Submission Date 02 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 7.93 Lakhs
Tender Fee Ref. Documents
EMD 15873
Exemption Not Available
Document List
2911.pdf
BOQ_2558668.xls
e13a2174-f7b4-45ca-9008-a7980e0cd00c.html
Tendernotice_1 (39).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.