Housing Urban and Rular Development Local Bodies Closing in 5 days TDR #57574621

Tender For maintenance Of E.I, Repair And Replacement Of Unserviceable Conventional Fittings With Led Fittings And Burnt Out Switchgear In Punjab & Haryana Civil Sectt. Building, Chandigarh. (R/F Punjab & Haryana Govt.)

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
5.97 Lakhs
Estimated cost
Bid Submission
25 Sep 2026
5 days left
EMD
12000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance Of E.I, Repair And Replacement Of Unserviceable Conventional Fittings With Led Fittings And Burnt Out Switchgear In Punjab & Haryana Civil Sectt. Building, Chandigarh. (R/F Punjab & Haryana Govt.)

BOQ

Name of Work:- Mtc of E.I, repair and replacement of unserviceable conventional fittings with LED fittings and burnt out switchgear in Punjab & Haryana Civil Sectt. building, Chandigarh. (R/F Punjab & Haryana Govt.)
Sl. No. Item Description
1DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
23 x 1.5 sq. mm
33 x 2.5 sq. mm
4DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
5DSR 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
65/6 amps switch
73 pin 5/6 amp. socket outlet
85/6 amps switch
93 pin 5/6 amp. socket outlet
10DSR 9.2 Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
11DSR 8.7 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt)Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
1236 watt
13DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
14125 A,36KA,FPMCCB
15200 A,36KA,FPMCCB
16400 A,50KA,FPMCCB
17DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
18Single pole
19DSR 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
204 way (4 + 12), Double door
21S/E of enclosure for MCCB 125/200 amp. 3 pole made out of 16 gauge MS sheet. The enclosure is to be painted after one coat of primer including its erection in existing angle iron board with
22S/E of enclosure for MCCB 400 amp. 3 pole made out of 16 gauge MS sheet. The enclosure is to be painted after one coat of primer including its erection in existing angle iron board with
23Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The bakelite should be of Superhylam/ Formica/ Greenlam (ISI marked) make only.
24Supply and Erection of electronic step type socket type fan regulator in existing B.L. Sheet including making connection and petty material reqd. to complete the job.
25S/E of 18/20 watt polycarbonate tube rod 4’ long. The tube rod should be replaced in the place of existing defective tube rod in existing tube fittings as per the various locations. The job includes the cost of petty material required t site as per the satisfaction of the EIC. The tube rod should be of Philips/ Wipro/ Bajaj/ Havells/ Surya/Jaquar/Trilux/LT/ Crompton/Panasonic make only.
26S/E of PVC sheathed copper wire following sizes to be drawn in existing pipes. The job includes making connections all labour and petty material required to complete the job to the entire satisfaction of the E.I.C. of the work. The copper wire should be of Polycab/ KEI/ Havells/ Finolex/ R.R. Kables make only. The wire should be of ISI marked only.
2723./.076 flexible wire 2 core Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57574621
AUTHORITY Local Bodies
TENDER VALUE 5.97 Lakhs
LAST DATE 25-09-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for maintenance Of E.I, Repair And Replacement Of Unserviceable Conventional Fittings With Led Fittings And Burnt Out Switchgear In Punjab & Haryana Civil Sectt. Building, Chandigarh. (R/F Punjab & Haryana Govt.)
Basic Detail
Tender No E3/47W/141
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 18 Sep 2026
Submission Date 25 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value 5.97 Lakhs
Tender Fee Ref. Documents
EMD 12000
Exemption Not Available
Document List
576c20da-2660-4948-b38b-2a8104c97a9a.html
BOQ_117386.xls
Tendernotice_1 (33).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

576c20da-2660-4948-b38b-2a8104c97a9a.html

xls

BOQ_117386.xls

pdf

Tendernotice_1 (33).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders