Tender For Construction Of Chain Link Boundary Fencing For Additional Land At Apcd, Amguri, Sivasagar, Assam
Tender Overview
Project Description
Tender for Construction Of Chain Link Boundary Fencing For Additional Land At Apcd, Amguri, Sivasagar, Assam
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Sep-2026 | Corrigendum 1 | Technical Bid | 07-Oct-2026 |
| 2 | 24-Sep-2026 | Corrigendum 03 | Technical Bid | 12-Oct-2026 |
| 3 | 24-Sep-2026 | 1st Extension Notice | Date | 12-Oct-2026 |
| 4 | 23-Sep-2026 | BOQ Corrigendum | BOQ | 12-Oct-2026 |
| 5 | 19-Sep-2026 | Corrigendum 1 | Technical Bid | 12-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Construction of “ Officer’s Hostel at Karbi Langpi Middle-II Hydro Power Project, Morinto, Karbi Anglong, Assam” |
| 2 | 2.0 1.0 PART-A (Civil Works) |
| 3 | Activity upto Plinth Level: i.e, Earthwork in Excavation/ Filling, PCC (1:3:6), Formwork, Dry Stone Pitching, Brick Work (in Sub Structure), Damp Proof Course (1:1:2) , Foundation and pedestal RCC (1:1.5:3), Steel Reinforcement etc . |
| 4 | Activity above Plinth Level: i.e PCC (1:3:6), Formwork, Superstructure RCC (1:1.5:3) for Column, Lintel with Steel Reinforcement, Brick Work and Plastering as per the specifications |
| 5 | Plinth protection 50mm thick of cement concrete 1:3:6, all around the premises. |
| 6 | Cement Concrete paver blocks in footpath 60mm thick Chamfered edge |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) _ For Roof Truss i.e Rafter, purline, post & strut, post plate including all connection system all activity as per the specifications. |
| 8 | Roofing Work: 0.50mm Precoated galvanized iron profile sheets , Flushing Aprons and Barge Boards |
| 9 | Doors:1. Main Door and Internal door for Guest room: Double leaf door- One (01) and Single leaf door- one (01). Laminated Modular ( Partly Glazed and Partly Panel) made of teak Wook with varnishing and mica finish door boundary. 2. Main and W/c Door for VIP room: Modular door ( mica finish)- Main door- 01 and W/c door-013. Other Main doors and W/c's : WPC frame, Flush/WPC door shutter in rooms and w/c's Main Door- 4 no's , W/c Door- 5 no's |
| 10 | Hydraulic door closer :(having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete- for Guest and VIP room |
| 11 | Windows:All the windows upvc with toughened glass.W1- 1200mmx1200mm- 12 no's ( with Iron Grill)W2- 450mmx600mm- 6 no's ( with Iron Grill)including fixing screws/anchors, plugs, packers, handles, locks, hinges/rollers, glazing , gaskets, setting blocks, PU foam, silicone sealant, drainage caps and cover caps, complete in all respects. |
| 12 | Fall Ceiling :Providing and fixing 15 mm thick tegular-edged calcium silicate false ceiling tiles of size 595×595 mm, of approved texture/design, suspended at all heights on a galvanized metal T-grid system comprising main-T and cross-T runners, GI hanger rods, dash fasteners, level adjusters, perimeter wall angles and necessary fixing accessories, complete in true horizontal level and as per CPWD Specifications. |
| 13 | Tiles Work:Vitrified floor tiles in all Rooms and Varandah’s, Ceramic glazed wall tiles floors and walls of wash areas |
| 14 | Painting Works:Walls: Water proof wall putty, Priming coat, Acrylic Emulsion PaintIron and Grill: Multi Surface metallic paint over the priming coat. Texture Wall Paint: Over the entrance wall |
| 15 | Pavers Block: Cement concrete interlocking colored block 60 mm thick |
| 16 | Plinth protection work all around the premises. |
| 17 | Rain Water Harvesting System: Underground Reservoir capacity 5000 Ltrs, Sand filtration Unit 1000 Ltrs, Enclosed with 230mm 1st class brick wall, PCC floor, FRP underground storage tank, 1,000 L filter chamber, graded filter media comprising coarse aggregate/gravel, fine sand and supporting layers, PVC/HDPE rainwater down-take and inlet pipes with elbows, tees, sockets and reducers, first-flush arrangement, silt trap, inlet diffuser, overflow and drain arrangements, non-return/check valve, isolation valves, inspection/manhole covers, mosquito-proof screens, vent pipe, water-level indicator, suction/discharge accessories where required, pipe clamps/supports, waterproofing/saelant and all necessary joints, connectors and fittings, complete in all respect. 2.0 PART- B ( SANITARY AND WATER SUPPLY WORKS) |
| 18 | Water Closet ( European Type): vitreous china pedestal type water closet (EuropNo'sn type W.C. pan) with sNo'st and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic sNo'st, lid, SS jet ( HNo'slt FJobcet), CP Bib cock etc. |
| 19 | Wash Basin: with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked |
| 20 | PVC pipe line for Water Closet, Waste pipeline , Rain water collection pipe, Ventilation pipe |
| 21 | PVC molded fittings/ accessories: Coupler, Tee with and without door, Elbow, Bend etc. Waste pipe for sink or wash basin etc. |
| 22 | Glass shelf, Soap dish holer, towel rail, Mirror in all the wash rooms./washing area. |
| 23 | Brass Single lever telephonic wall mixer or Diverter System in all the washeooms/shower areas. |
| 24 | Providing and fixing CPVC pipe network system of 50 mm, 40 mm and 15 mm dia, including all necessary CPVC pipes, fittings, elbows, tees, sockets, reducers, unions, valves, clamps/supports, solvent cement, jointing materials and connections to fixtures, including testing for leakage and pressure, complete in all respect. |
| 25 | C.P. brass long nose bib cock in all the wash rooms, exterior points |
| 26 | All plumbing accessories for Rain Water Harvesting: PPR Unions, gun metal gate valve with C.I. wheel, C.P. brass angle valve and any other required for complete installation of Rain water harvesting system, complete sanitary and water supply system. 3.0 PART-C (Electrical works) |
| 27 | Complete Wiring: Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire2 X 4 sq. mm + 1 X 4 sq. mm earth wire4 X 6 sq. mm + 2 X 6 sq. mm earth wire4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 28 | GI Box: Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)- 5 Nos3 Module (100mmX75mm)- 10 Nos4 Module (200mmX75mm)- 8 Nos8 Module (125mmX125mm)- 7 No’s12 Module (200mmX150mm)- 7 Nos |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch- 109 no's15/16 A switch- 30 no's3 pin 5/6 A socket outlet- 18 no's6 pin 15/16 A socket outlet- 14 no'sBell push- 6 no'smodular blanking plate |
| 30 | Supplying and fixing electronic fan regulator |
| 31 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, No'srth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door |
| 32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. |
| 33 | Supplying and fixing brass batten/ angle holder- 34 nos, 3 pin, 5 A ceiling rose-14 nos , call bell/ buzzer- 6 nos |
| 34 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor |
| 35 | Supplying, fitting and fixing of exhaust fan 200mm sweep |
| 36 | Lighting: Supplying ACE Saver 18W bulb – 34 nosSQUARE LED PANEL 12 W 3000 K- 20 nos |
| 37 | Decorative Lighting: |
| 38 | Adjustable Inverter AC, 2 Ton, Minimum 3 star |
| 39 | Geyser PURO TURBO DX 6 L |
| 40 | Centrifugal Deep Well Jet Pumps- JCP12A- 1HP- Discharge 1700-400 LPH- HNo'sd Range 9-24m, with 25A Single phase motor starter switch required for Rainwater Harvesting System 4.0 PART-D (Interior works) |
| 41 | Curtain Wall panel ( Laminated ) for VIP lobby room |
| 42 | 02 no's TV Unit's |
| 43 | PVC wall panel for Guest Room |
| 44 | Texture paint on Entrance Wall of Guest Room |
| 45 | LED profile Decorative Light in Guest Room and VIP Lobby |
| 46 | Electrician for Installation |
| 47 | Electronic Technician for Installation |
| 48 | Laminated Door 3 No's Guest Room and VIP Room |
| 49 | Wardrobe and Dressing ( Made of Block Board) for VIP Room Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender