Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57571591

Tender For Provision Of Certain Sanction Work In The Area Of Age B/R-I And Age E/M Under Ge (Central) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
48.29 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
19 days left
EMD
96580
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Provision Of Certain Sanction Work In The Area Of Age B/R-I And Age E/M Under Ge (Central) Delhi Cantt-10- 1 M&L, Pcc 1:3:6 Type C-2 Using 40Mm Graded Stone Aggregate As In Foundation, Fitting And Mass Concrete 2 M&L For 15-20Mm Thick Screed Bed Or Bedding Layer Of Cement Mortar 1:6 Complete All As Specified. 3 M&L Supplying And Laying Of Precast U-Shape Strom Water Drains Having In To In Dimension 600Mm X 600Mm Of Top Thickness _50Mm And Bottom Thickness Of _70_Mm Of 2000Mm Long Each From T6 Load Carrying Capacity-4.8Ton Axel Load And 2.4 T Wheel Load Confirming To Bis/Jis Having High Performance Self-Compacting Concrete M-40 Cylindrical Strength / M-50 Grade Cube Strength And Fe500/Fe550D Reinforcement. The Product Should Be Manufactured With Self Compacting Concrete In Wet-Cast Method Only And Dully Steam Cured For Accelerated Curing. The Product Shall Have Tie Shape Joint 10-20Mm With 25Mm Depth Groove As Per Bis/Jis On Both Side Of Each Storm Water Drain For Jointing Two Precast Storm Water Drains Using Cement Mortar Or Suitable Non Shrink Grout. The Precast Utility Duct Must Consists Of Special In-Built Inlet At Appropriate Location For Fixing De-Shackle For Mechanical Installation, Including Supply Transportation, Installation Of Specific Location At Site In Line, Level, Gradient And Plumb With Necessary Testing Commissioning And Filling Cement Slurry B/W Two Segment Joint Etc Complete All As Specified And Directed.2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed Cwe. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. 4 Providing And Fixing Factory Made Pre Caste High Strength Precast Draine Covers With Hole, Having Concrete Of Strength Not Less Than M-40, Size 500 X 730 X 80 (Mm), Are Varied As For Site Requirement , Reinforeced With As Per Structural Requirement Tmt Grade Fe 500/550D,All As Specified As Per Direction Of Eng In Charge. 2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed At Hq Cwe Delhi Cantt. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. 5 M&L Supplying And Laying Of Precast Box Culvert-Road Crossing Having In To In Dimension 600Mm X 600Mm Of Top Thickness _50Mm And Bottom Thickness Of _70_Mm Of 2000Mm Long Each From T6 Load Carrying Capacity-4.8Ton Axel Load And 2.4 T Wheel Load Confirming To Bis/Jis Having High Performance Self-Compacting Concrete M-40 Cylindrical Strength / M-50 Grade Cube Strength And Fe500/Fe550D Reinforcement. The Product Should Be Manufactured With Self Compacting Concrete In Wet-Cast Method Only And Dully Steam Cured For Accelerated Curing. The Product Shall Have Tie Shape Joint 10-20Mm With 25Mm Depth Groove As Per Bis/Jis On Both Side Of Each Storm Water Drain For Jointing Two Precast Storm Water Drains Using Cement Mortar Or Suitable Non Shrink Grout. The Precast Utility Duct Must Consists Of Special In-Built Inlet At Appropriate Location For Fixing De-Shackle For Mechanical Installation, Including Supply Transportation, Installation Of Specific Location At Site In Line, Level, Gradient And Plumb With Necessary Testing Commissioning And Filling Cement Slurry B/W Two Segment Joint Etc Complete All As Specified And Directed.2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed At Hq Cwe Delhi Cantt. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. Please Enable Macros To View Boq Information 6 M&L Supplying And Laying Of Precast Box Culvert-Road Crossing Having In To In Dimension 600Mm X 600Mm Of Top Thickness _50Mm And Bottom Thickness Of _70_Mm Of 2000Mm Long Each From T6 Load Carrying Capacity-4.8Ton Axel Load And 2.4 T Wheel Load Confirming To Bis/Jis Having High Performance Self-Compacting Concrete M-40 Cylindrical Strength / M-50 Grade Cube Strength And Fe500/Fe550D Reinforcement. The Product Should Be Manufactured With Self Compacting Concrete In Wet-Cast Method Only And Dully Steam Cured For Accelerated Curing. The Product Shall Have Tie Shape Joint 10-20Mm With 25Mm Depth Groove As Per Bis/Jis On Both Side Of Each Storm Water Drain For Jointing Two Precast Storm Water Drains Using Cement Mortar Or Suitable Non Shrink Grout. The Precast Utility Duct Must Consists Of Special In-Built Inlet At Appropriate Location For Fixing De-Shackle For Mechanical Installation, Including Supply Transportation, Installation Of Specific Location At Site In Line, Level, Gradient And Plumb With Necessary Testing Commissioning And Filling Cement Slurry B/W Two Segment Joint Etc Complete All As Specified And Directed.2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed At Hq Cwe Delhi Cantt. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. Please Enable Macros To View Boq Information

BOQ

Name of Work:- PROVN OF CERTAIN SANCTION WK IN THE AREA OF AGE B/R-I AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
Sl. No. Item Description
1M&L, PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation, fitting and mass concrete
2M&L for 15-20mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified.
3M&L Supplying and laying of Precast U-Shape Strom water Drains having in to in dimension 600mm x 600mm of top thickness _50mm and bottom thickness of _70_mm of 2000mm long each from T6 load carrying capacity-4.8Ton axel load and 2.4 T wheel load confirming to BIS/JIS having high performance self-compacting concrete M-40 cylindrical strength / M-50 Grade cube strength and Fe500/Fe550D reinforcement. The product should be manufactured with self compacting concrete in wet-cast method only and dully steam cured for accelerated curing. The product shall have tie shape joint 10-20mm with 25mm depth groove as per BIS/JIS on both side of each storm water drain for jointing two precast storm water drains using cement mortar or suitable non shrink grout. The precast utility duct must consists of special in-built inlet at appropriate location for fixing de-shackle for mechanical installation, including supply transportation, installation of specific location at site in line, level, gradient and plumb with necessary testing commissioning and filling cement slurry b/w two segment joint etc complete all as specified and directed.2. Contractor shall be enlisted with MES in Class ‘B’ and above and category a(i) having MOU with Precast/ Prefabricated manufacturer who has executed precast/ prefabricated building works with satisfactory performance subject to satisfactory remarks with performance in respect of works in hand as reflected in Workload return (WLR) or any other report circulated by competent engineer authority. The contractor should have possessed Provident Fund Code Number and GST Registration Number. Only MES Enlisted contractor is eligible with MOU. complete all as specified and directed by eng in chargeNote -1- including crane or hydra for laying drains 2-Sample as installed/laid at sena bhavan and displayed CWE. 3-Once the precast drains are on site (+,-)5% of Each lot will be subjected to rebound hammer test +compressive testing 4- Compressive test Certificate from Original OEM with inhouse NABL accredited lab only, to be submitted with each batch from Authenticity. MOU with Labs and 3rd Party Lab test certificate will not be accepted. 5. 10 Years warranty to be provided on Drains against leakage or seepage.
4Providing and fixing factory made pre caste High strength precast draine covers with hole, having concrete of strength not less than M-40, size 500 x 730 x 80 (mm), are varied as for site requirement , reinforeced with as per structural requirement TMT Grade Fe 500/550D,all as specified as per direction of eng in charge. 2. Contractor shall be enlisted with MES in Class ‘B’ and above and category a(i) having MOU with Precast/ Prefabricated manufacturer who has executed precast/ prefabricated building works with satisfactory performance subject to satisfactory remarks with performance in respect of works in hand as reflected in Workload return (WLR) or any other report circulated by competent engineer authority. The contractor should have possessed Provident Fund Code Number and GST Registration Number. Only MES Enlisted contractor is eligible with MOU. complete all as specified and directed by eng in chargeNote -1- including crane or hydra for laying drains 2-Sample as installed/laid at sena bhavan and displayed at HQ CWE delhi cantt. 3-Once the precast drains are on site (+,-)5% of Each lot will be subjected to rebound hammer test +compressive testing 4- Compressive test Certificate from Original OEM with inhouse NABL accredited lab only, to be submitted with each batch from Authenticity. MOU with Labs and 3rd Party Lab test certificate will not be accepted. 5. 10 Years warranty to be provided on Drains against leakage or seepage.
5M&L Supplying and laying of Precast Box Culvert-Road crossing having in to in dimension 600mm x 600mm of top thickness _50mm and bottom thickness of _70_mm of 2000mm long each from T6 load carrying capacity-4.8Ton axel load and 2.4 T wheel load confirming to BIS/JIS having high performance self-compacting concrete M-40 cylindrical strength / M-50 Grade cube strength and Fe500/Fe550D reinforcement. The product should be manufactured with self compacting concrete in wet-cast method only and dully steam cured for accelerated curing. The product shall have tie shape joint 10-20mm with 25mm depth groove as per BIS/JIS on both side of each storm water drain for jointing two precast storm water drains using cement mortar or suitable non shrink grout. The precast utility duct must consists of special in-built inlet at appropriate location for fixing de-shackle for mechanical installation, including supply transportation, installation of specific location at site in line, level, gradient and plumb with necessary testing commissioning and filling cement slurry b/w two segment joint etc complete all as specified and directed.2. Contractor shall be enlisted with MES in Class ‘B’ and above and category a(i) having MOU with Precast/ Prefabricated manufacturer who has executed precast/ prefabricated building works with satisfactory performance subject to satisfactory remarks with performance in respect of works in hand as reflected in Workload return (WLR) or any other report circulated by competent engineer authority. The contractor should have possessed Provident Fund Code Number and GST Registration Number. Only MES Enlisted contractor is eligible with MOU. complete all as specified and directed by eng in chargeNote -1- including crane or hydra for laying drains 2-Sample as installed/laid at sena bhavan and displayed at HQ CWE delhi cantt. 3-Once the precast drains are on site (+,-)5% of Each lot will be subjected to rebound hammer test +compressive testing 4- Compressive test Certificate from Original OEM with inhouse NABL accredited lab only, to be submitted with each batch from Authenticity. MOU with Labs and 3rd Party Lab test certificate will not be accepted. 5. 10 Years warranty to be provided on Drains against leakage or seepage. Please Enable Macros to View BoQ information
6M&L Supplying and laying of Precast Box Culvert-Road crossing having in to in dimension 600mm x 600mm of top thickness _50mm and bottom thickness of _70_mm of 2000mm long each from T6 load carrying capacity-4.8Ton axel load and 2.4 T wheel load confirming to BIS/JIS having high performance self-compacting concrete M-40 cylindrical strength / M-50 Grade cube strength and Fe500/Fe550D reinforcement. The product should be manufactured with self compacting concrete in wet-cast method only and dully steam cured for accelerated curing. The product shall have tie shape joint 10-20mm with 25mm depth groove as per BIS/JIS on both side of each storm water drain for jointing two precast storm water drains using cement mortar or suitable non shrink grout. The precast utility duct must consists of special in-built inlet at appropriate location for fixing de-shackle for mechanical installation, including supply transportation, installation of specific location at site in line, level, gradient and plumb with necessary testing commissioning and filling cement slurry b/w two segment joint etc complete all as specified and directed.2. Contractor shall be enlisted with MES in Class ‘B’ and above and category a(i) having MOU with Precast/ Prefabricated manufacturer who has executed precast/ prefabricated building works with satisfactory performance subject to satisfactory remarks with performance in respect of works in hand as reflected in Workload return (WLR) or any other report circulated by competent engineer authority. The contractor should have possessed Provident Fund Code Number and GST Registration Number. Only MES Enlisted contractor is eligible with MOU. complete all as specified and directed by eng in chargeNote -1- including crane or hydra for laying drains 2-Sample as installed/laid at sena bhavan and displayed at HQ CWE delhi cantt. 3-Once the precast drains are on site (+,-)5% of Each lot will be subjected to rebound hammer test +compressive testing 4- Compressive test Certificate from Original OEM with inhouse NABL accredited lab only, to be submitted with each batch from Authenticity. MOU with Labs and 3rd Party Lab test certificate will not be accepted. 5. 10 Years warranty to be provided on Drains against leakage or seepage. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57571591
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.29 Lakhs
LAST DATE 08-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Provision Of Certain Sanction Work In The Area Of Age B/R-I And Age E/M Under Ge (Central) Delhi Cantt-10- 1 M&L, Pcc 1:3:6 Type C-2 Using 40Mm Graded Stone Aggregate As In Foundation, Fitting And Mass Concrete 2 M&L For 15-20Mm Thick Screed Bed Or Bedding Layer Of Cement Mortar 1:6 Complete All As Specified. 3 M&L Supplying And Laying Of Precast U-Shape Strom Water Drains Having In To In Dimension 600Mm X 600Mm Of Top Thickness _50Mm And Bottom Thickness Of _70_Mm Of 2000Mm Long Each From T6 Load Carrying Capacity-4.8Ton Axel Load And 2.4 T Wheel Load Confirming To Bis/Jis Having High Performance Self-Compacting Concrete M-40 Cylindrical Strength / M-50 Grade Cube Strength And Fe500/Fe550D Reinforcement. The Product Should Be Manufactured With Self Compacting Concrete In Wet-Cast Method Only And Dully Steam Cured For Accelerated Curing. The Product Shall Have Tie Shape Joint 10-20Mm With 25Mm Depth Groove As Per Bis/Jis On Both Side Of Each Storm Water Drain For Jointing Two Precast Storm Water Drains Using Cement Mortar Or Suitable Non Shrink Grout. The Precast Utility Duct Must Consists Of Special In-Built Inlet At Appropriate Location For Fixing De-Shackle For Mechanical Installation, Including Supply Transportation, Installation Of Specific Location At Site In Line, Level, Gradient And Plumb With Necessary Testing Commissioning And Filling Cement Slurry B/W Two Segment Joint Etc Complete All As Specified And Directed.2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed Cwe. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. 4 Providing And Fixing Factory Made Pre Caste High Strength Precast Draine Covers With Hole, Having Concrete Of Strength Not Less Than M-40, Size 500 X 730 X 80 (Mm), Are Varied As For Site Requirement , Reinforeced With As Per Structural Requirement Tmt Grade Fe 500/550D,All As Specified As Per Direction Of Eng In Charge. 2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed At Hq Cwe Delhi Cantt. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. 5 M&L Supplying And Laying Of Precast Box Culvert-Road Crossing Having In To In Dimension 600Mm X 600Mm Of Top Thickness _50Mm And Bottom Thickness Of _70_Mm Of 2000Mm Long Each From T6 Load Carrying Capacity-4.8Ton Axel Load And 2.4 T Wheel Load Confirming To Bis/Jis Having High Performance Self-Compacting Concrete M-40 Cylindrical Strength / M-50 Grade Cube Strength And Fe500/Fe550D Reinforcement. The Product Should Be Manufactured With Self Compacting Concrete In Wet-Cast Method Only And Dully Steam Cured For Accelerated Curing. The Product Shall Have Tie Shape Joint 10-20Mm With 25Mm Depth Groove As Per Bis/Jis On Both Side Of Each Storm Water Drain For Jointing Two Precast Storm Water Drains Using Cement Mortar Or Suitable Non Shrink Grout. The Precast Utility Duct Must Consists Of Special In-Built Inlet At Appropriate Location For Fixing De-Shackle For Mechanical Installation, Including Supply Transportation, Installation Of Specific Location At Site In Line, Level, Gradient And Plumb With Necessary Testing Commissioning And Filling Cement Slurry B/W Two Segment Joint Etc Complete All As Specified And Directed.2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed At Hq Cwe Delhi Cantt. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. Please Enable Macros To View Boq Information 6 M&L Supplying And Laying Of Precast Box Culvert-Road Crossing Having In To In Dimension 600Mm X 600Mm Of Top Thickness _50Mm And Bottom Thickness Of _70_Mm Of 2000Mm Long Each From T6 Load Carrying Capacity-4.8Ton Axel Load And 2.4 T Wheel Load Confirming To Bis/Jis Having High Performance Self-Compacting Concrete M-40 Cylindrical Strength / M-50 Grade Cube Strength And Fe500/Fe550D Reinforcement. The Product Should Be Manufactured With Self Compacting Concrete In Wet-Cast Method Only And Dully Steam Cured For Accelerated Curing. The Product Shall Have Tie Shape Joint 10-20Mm With 25Mm Depth Groove As Per Bis/Jis On Both Side Of Each Storm Water Drain For Jointing Two Precast Storm Water Drains Using Cement Mortar Or Suitable Non Shrink Grout. The Precast Utility Duct Must Consists Of Special In-Built Inlet At Appropriate Location For Fixing De-Shackle For Mechanical Installation, Including Supply Transportation, Installation Of Specific Location At Site In Line, Level, Gradient And Plumb With Necessary Testing Commissioning And Filling Cement Slurry B/W Two Segment Joint Etc Complete All As Specified And Directed.2. Contractor Shall Be Enlisted With Mes In Class ‘B’ And Above And Category A(I) Having Mou With Precast/ Prefabricated Manufacturer Who Has Executed Precast/ Prefabricated Building Works With Satisfactory Performance Subject To Satisfactory Remarks With Performance In Respect Of Works In Hand As Reflected In Workload Return (Wlr) Or Any Other Report Circulated By Competent Engineer Authority. The Contractor Should Have Possessed Provident Fund Code Number And Gst Registration Number. Only Mes Enlisted Contractor Is Eligible With Mou. Complete All As Specified And Directed By Eng In Chargenote -1- Including Crane Or Hydra For Laying Drains 2-Sample As Installed/Laid At Sena Bhavan And Displayed At Hq Cwe Delhi Cantt. 3-Once The Precast Drains Are On Site (+,-)5% Of Each Lot Will Be Subjected To Rebound Hammer Test +Compressive Testing 4- Compressive Test Certificate From Original Oem With Inhouse Nabl Accredited Lab Only, To Be Submitted With Each Batch From Authenticity. Mou With Labs And 3Rd Party Lab Test Certificate Will Not Be Accepted. 5. 10 Years Warranty To Be Provided On Drains Against Leakage Or Seepage. Please Enable Macros To View Boq Information
Basic Detail
Tender No GE/TOKEN-90/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 17 Sep 2026
Submission Date 08 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 48.29 Lakhs
Tender Fee 500
EMD 96580
Exemption Available
Document List
76b6137a-ef13-45e3-8e7c-f0cb3178167a.html
BOQ_885485.xls
Tendernotice_1 (10).pdf
tenderpage.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

76b6137a-ef13-45e3-8e7c-f0cb3178167a.html

xls

BOQ_885485.xls

pdf

Tendernotice_1 (10).pdf

pdf

tenderpage.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders