Tender for Construction Of New Model Anganwadi Building And Equipments Of Playing Materials At Kalavai Road Group House Oht Near In Thimiri Town Panchayat , Earth Work Excavation For Foundation By Manual Means For Isolated, Combined And Other Type Foundations In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By The Departmental Officers With An Initial Lead Of 10 Mts And Initial Lift Of 2.00Mts. And Clearing And Levelling The Site, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supply And filling In Foundation And Basement With Gravel In Layers Of Not More Than 15Cm.Thick Well Rammed Watered And Compacted With Surface Vibrator, Watered And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Cement Concrete 1:5:10 (One Cement, Five Crushed Stone Sand And Ten Hard Broken Stone Jelly) Using 40 Mm Gauge Hard Broken Granite Stone Jelly For Foundation Including Dewatering Wherever Necessary And Laid In Layers Of Not More Than 15 Cm Thick Well Rammed, Consolidated And Including Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. -Mixing By Manual Means , Brick Work In Following Cement Mortar Using Best Quality Burnt Clay Brick Of Size 9 X 4 1/2 X 3 With Class Designation Of 7.5 Conforming To Is 1077-1992 For Oundation And Basement Including Cost Of Mortar Plasticizer Curing, Etc.,Complete Complying With Standard Specification And As Directed By The Departmental Officers. Brickwork Shall Be Done As Per Is 2212-1991 Adopting English Bond Generally.Other Type Of Bond Shall Be Done As Directed By The Executive Engineer In Charge.In Cement Mortar 1:5 , Providing And Laying In Position, Standardised Concrete Mix M-20 Grade Using In-Situ Concrete Batching Plant/ Ready Mix Concrete (Rmc) Adopting Weigh Batch Method In Accordance With Is 456 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Reinforced Cement Concrete Items Of Works With Minimum Cement Content Of 325 Kg/M3 And Maximum Water Cement Ratio Of 0.55, Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete,Improve Workability Without Impairing Strength And Durability With About (5 Cu.M) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M) 5156 Kg. Of 10- 12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Conveyance Of Concrete From Batching Plant To Work Site, Electricity Charges And Other Works & Labour Cost Involved For Concrete Production, Laying, Vibrating With Mechanical Vibrators, finishing, Curing, Etc. And Providing fixtures Like Fan Clamps In The Reinforced Cement Concrete floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Supplying And Errecting For Sides & Soffits Including Supports And Strutting Upto 3.29M Height For Plane Surface In All Floors Including Cost And Conveyance And All Labour Charges Etc. , Centring Below Gl , Centring Above Gl, Roof & Roof Beam , Supplying, Fabricating And Placing In Position Mild Steel / Ribbed Tor Steel Reinforcement Grills Of All Variety Like Hysd/Ctd/Tmtand All Grade Like Fe 500,Fe550d, Fe 500 D Etc., For All Reinforced Cement Concrete Works As Per Design Given Including Cost Of Steel Reinforcement And G.I. Binding Wire, Wastage Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers.(Contractor Has To Make His Own Arrangements For The Supply Of Steel Reinforcement And Binding Wire) , Weathering Course In Brick Jelly Lime Concrete Using Broken Brick Jelly Of Size 20Mm Uniform Gauge In Pure Slaked Lime (No Crushed Stone Sand To Be Used) To The Proportion Of Brick Jelly To Lime Being 32:12.5 By Volume And Laid Over The Reinforced Cement Concrete Roof Slab In A Single Layer Of Required Slope And finished By Beating The Concrete With Wooden Beaters Of Approved Pattern, Keeping The Surface Constantly Wet By Sprinkling Lime Jaggery Water, Etc., Complete As Per Standard Specification And As Directed By The Deparmental Officers. , Finishing The Top Of Roof With One Course Of Machine Pressed Tiles Of Following Size Of Approved Quality Set In Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) 12Mm Thick Mixed With Water Proofing Compound Conforming To Iss At 2% By Weight Of Cement Used And The Joints Pointed Neatly To Full Depth Of Tiles With The Same Cement Mortar Mixed With Red Oxide And Water Proofing Compound Including Curing Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers , Plastering With Cement Mortar 1:5 (One Cement And Five Plastering Sand), 12Mm Thick In All floors Including Mortar Plasticizer At 200Ml Per 50Kg Of Cement Used, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Special Ceiling Plastering And finishing The Exposed Surface Of All Reinforced Cement Concrete Items Of Work Such As Slabs, Beams, Sunshades, Facia, Canopy Slab, Staircase Waist Slab, Landing Slab Etc., With Cement Mortar 1:3 (One Cement And Three Plastering Sand) 10Mm Thick Including Mortar Plasticizer At 200Ml Per 50Kg Of Cement Used , Hacking The Surfaces And Curing, Etc., In All floors Complying With Standard Specification And As Directed By The Departmental Officers , Paving The Floor With Pre-Polished Concrete Anti-Skid Tiles (Required Shape And Design) Of 20Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three Crushed Stone M.Sand) 20Mm Thick And Pointed With White Cement Mixed With Colouring Pigment At The Rate Of 0.40 Kg. / Sq.M., Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) Using Anti-Skid Tiles (Observed Data) , Dadooing Walls With Following Best Approved Quality, White / Colour Glazed Tiles Conforming To Is 15622 Of Following Sizes In Cement Mortar 1:2 (One Cement And Two Crushed Stone Sand),10 Thick With Mortar Plasticizer And Pointing The Joints With Water Resistant Tile Epoxy Grout At The Rate Of 0.27 Kg. / Sq.M. Neatly In All floors, Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.(The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Solid Pvc Door Shutters Using 19 Gauge 19Mm Ms Square Tubes For Styles And Outer Frames. 15Mm Ms Square Tubes For Top, Lock And Bottom Rails. The Steel Tubes Shall Be Covered With 5Mm Thick Solid Pvc Sheets. Shutter Using 5Mm Thick Solid Pvc Sheets For Panelling Shall Rigidly Fixed In Position Including Necessary Furniture And Fittings. The Over All Size Of Styles Shall Be 50Mm X 30Mm. The Over All Size Of Top Rail, Lock Rail And Bottom Rail Shall Be 75Mm X 30Mm. The Over All Size Of Frames Shall Be 50Mm X 45Mm With Suitable Rabate For Housing The Shutter , Manufacturing, Supplying And fixing Of Entrance Steel Door Single Leaf Covered With The Following Specification. M.S Angles Of A Size 40X40x6mm Are Used For The Outer Frames And M.S. Angles Of Size 35X35x5mm For The Shutter Frames Stiffeners With 32X6mm M.S. flat Is Provided At Required Intervals In The Shutter Frames 18 Gauge C.R. Sheet Is Laid As Panel In The Shutter And Welded Intact For 1/3 Bottom Portion Of The Shutter. M.S. flat 18X5mm Is Welded Over The 32X6mm M.S. flat Sand Witching The Cr Sheet In Between.Additional Stiffener With 18X5mm M.S. flat Is Provided Diagonally At The Rear Side Of The Shutter. The Balance 2/3 Portion At Top Is Provided With Grill At An Average Weight Of 20 Kg/Sq.M With 300Mm Height Of fixed Glazing At Top With 3Mm Thick Pin Headed Glass Including 3 Nos Steel Parliament Hinges Of Size 125Mm X 150Mm For Single Leaf Shutter To Be Provided, 6 Nos Of Holdfasts 200Mm In Length Made Of Angle Section Spliced At The Ends Are Welded To The Outer Frame Of The Door. Tower Bolts 3 Nos, One At The Top, One At Lock Rail (Inner Side) And The Other At The Bottom Are Provided. One Aldrop Is Provided At An Appropriate Place In The Door. 2Nos Of Handle Are To Be Provided. A Tie Bar Is Provided At The Bottom Of The Outer Frame To Prevent Twisting Of Frame During Transportation Or fixing. All Members Are Given One Coat Of Red Oxide Primer As Directed By The Departmental Officer. The Rate Includes Cost Of All Materials, Labour, Charges,Taxes, Transportation To Site Of Work, Loading, Unloading And All Other Incidental Charges Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. - Single Leaf Of Size 1.00M X 2.40M. , Manufacturing, Supplying And fixing In Position Of Reinforced Cement Concrete Jally Of 5Cm Thick In Cement Concrete 1:2:4 Using 20Mm Machine Crushed Stone Jelly (Excluding Cost Of Reinforcement Steel) Including Cost Of Mould, finishing, Curing, Lifting, fixing In Position Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Provision For Electrification Arrangements With Service Connection , Light Point Sd 17 , Fan Point Sd 106 , Plug Point Sd 17 , Tube Light Sd 88 , Painting New Plastered Wall Surface With Two finishing Coats Of Ready Mixed (Emulsion) Of Approved Quality And Colour Over One Coat Priming Coat In All floors Including The Cost Of Primer Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.(The Make, Quality And Colour Of Paint Should Be Got Approved By The Executive Engineer Before Use On Works.) , Painting New Iron Works Such As Steel Doors, Windows, Ventilators, Window Bars, Balustrades Etc., With Two Coats Of Best Approved first Quality And Colour Of Synthetic Enamel Paint Over The Existing Red Oxide Priming Coat In All floors Excluding Cost Of Priming Coat Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Make, Quality And Colour Of Paint Should Be Got Approved By The Executive Engineer Before Use On Works.) , Providing Black Board In Two Layers With first Layer In Cement Mortar 1:5 (One Cement And five Crushed Stone Sand)20Mm Thick And The Second Layer In Combination Mortar 1:1:6(One Cement One Lime And Six Crushed Stone Sand) 20Mm Thick And Providing Band All Round The Block Board In C.M 1:5 (One Cement And five Crushed Stone Sand) For 20Mm Thick And 50Mm Width Including Cost Of One Coat Of Block Oxide Paint Of Approved Quality Complying With Standard Specification. , Water Supply And Sanitary Arrangements , 1000 Lit Tank , 20Mm Pvc Pipe , 20 Mm Pvc Elbow , 20 Mm Pvc Tee , 75 Mm Pvc Pipe , 75Mm Dia Bend , 110 Mm Pvc Pipe 6Ksc , 110 Mm Pvc Bend 6Ksc , Supplying And fixing In Positon Indian Water Closet (Oriya Type) Of Size 580 X 440Mm White Glazed Earthern Ware Of Approved Quality And Brand With P Or S Trap Conforming To Bis With Crushed Stone Sand Cushion And Forming flooring Alround The Closet Using 40Mm Broken Brick Jelly In Lime Concrete 1:2:5 (One Lime, Two Crushed Stone Sandand Five Brick Jelly) 100Mm Thick And finishing The Top To The Required Slope And Including Giving Necessary Connection To Ci Soil Pipes (Including The Cost Of 100Mm Dia Ci Pipe For A Length Of 600Mm) By Dismantling Brick Masonry Wall / Reinforced Cement Concrete Roof / floor Slab And Making Good The Dismantled Portion To The Original Condition With Leakages Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. (The Water Closet Should Be Got Approved By The Executive Engineer Before Use On Works). , Manufacturing, Supplying And Fixing Of Stainless Steel Hand Rails For Staircase Using 50Mm Dia 304L Grade Stainless Steel Pipe Of 1.60Mm Thick At Required Locations To A Height Of 900Mm From Finished Floor Level Welded To 38Mm Dia Stainless Steel Pipe Post Of 1.00Mm Thick As Vertical At 900Mm Centre With 2 Nos. Of 25Mm Dia Intermediate Horizontal Stainless Steel Pipe Of 1.60Mm Thick In Between. The Vertical Pipe Has To Be Welded To The 100 X100 X 6Mm Ms Base Plate Encased In The Base Concrete. The Rate Is Inclusive Of The Charges For Cutting, Bending, Welding, Grinding, Polishing, Conveyance, Electrical Charges, Etc. Complete , Supplying And fixing In Position Best Approved Of Bis Quality Pvc Rain Water Down Fall Pipes Having A Pressure Of 4 Kg. / Sq.Cm Including Cost Of Necesory Pvc Shoe, Pvc Bend, Cast Iron Gratings Of Required Diameter And Special Clamps, Brass Screws, Nails, Etc., And fixing Of Cast Iron Gratings At Junction Of Parapet And The Reinforced Cement Concrete Roof Slab Including finishing Neatly Etc., Complete. The Rate Shall Be Inclusive Of Cast Of Removable Cast Iron Grating. The Pvc Pipe Shall Be fixed In Wall With Special Type Of U Clamp At The Centre Of The Pipe Line In Addition To Those For More Than 3.0 Metre Pipe Length, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers , Supplying And Laying Of Interlocking Paver Block Stone 63Mm Thick Over A Base Layer Of Crushed Stone Sandfilling Incl. Cost Of Materials Laying And Labour Charges Etc Complete Complying With The Standard Specification And As Directed By The Departmental Officers. , Supplying And Fixing Of Unbranded Outdoor Slide With Curved Spiral As Gem Portal , Supplying And Fixing Of Khelo Kudoo Outdoor Slide With Straight As Gem Portal , Supplying And Fixing Of Athletic Trends Industries Outdoor Slide As Gem Portal , Conducting Geophysical Survey, Quality And Quantity Test And Transportation Charges Etc, (This Includes Labour Charges In The Field, Rent Of The Vehicle For Reaching The Place, Rent Of The Instrument And Excluding Charges For The Geologist) , Drilling 150 Mm Dia Bore Well In Hard Rock Areas Anywhere In The State Inculding Transportation To Site Of Work In Hardrock Areas Inculding Labour Charges For Insertion Of Ms Casing Pipe And Flushing Of Borewell And For Minutes. ( As Per Md Twad Board Chennai Letter No : F15090/Ae/Cm/Twad/2013/ Dated:22/4/2013 ) , Supplying And Fixing Of 200 Mm Dia Of Casing Pipe Including All Cost And Conveyance Etc Complete. Twad Sor Page No : 22 , Supply And Delivery Of Clear Water Vertical Wet Type Submersible Pump Conforming To Is 8034/2002 And As Amended Thereafter And Bee 3 Star Rated Capable Of Discharging Noted Lpm Against Head Of Water Column Due To All Causes. The Pump Shall Be With Stainless Steel Shaft And Dynamically Balanced Bronze Or Cast Ss Impeller, Brass Screws And Ci Fg 200 Grade Pump Bowl/Diffuser With Isi Mark. The Pump Shall Be Directly Coupled To A Continuos Rated Two Pole Suitable Wet Type Vertical Squirrel Cage Induction Motor Suitable For Operation In Ac Single Phase 230 V+/- 10 %,50 Hz +/-5 % , Supply And Delivery Of Direct Online Starter Confirming To Is13947, Iec60947-1 And As Amended Thereafter With Suitable Kw Rating For Operation In Ac/Single Phase/50Hz(± 5%) And 230 V(±10%) Including Ammeter, Voltmeter, Thermal Overload Relay, 16 Amps 2 Pole Magnetic Contactor With Under Voltage Protection, Indication Lamp, Starting Capacitor, Running Capacitor And On/Off Push Button Switches, 5 Way Connector, Wiring With 1 Sq. Mm/1.5 Sq. Mm Copper Pvc Insulated Cable, Powder Coated Vermin Proof Box Including The Capacitor (The Cost Of Capacitor Is To Be Taken Separately). , Supply And Delivery Of Following 50 Mm Dia Upvc Column Pipe And Gi Pipes And Other Special Materials Of Good Quality Including Cost Of Materials And Labour With Cost For Coveyence To Site Etc Complete Complying With Standard Specifications. Etc., , 32 Mm Dia Upvc Column Pipe Twad , 32 Mm Upvc . Elbow , 32 Mm Upvc . Union Elbow , 32 Mm Dia Gi Flange Set , Bore M.S. Clamp Set , Bore Plate , Nylone Rope , 2.5 Sqmm 3Core Flate Cable , Erection Of Power Pumps In Borewell Labour Charges For Erection Of Twin Packer Duplex Type Jet Pumps In Borewells Upto 150 Mm Dia Including Fixing Of Suction Pipe Regulating Valves With Jet Assembly Upto A Maximum Depth Of 30 M And Delivery Pipe Valves Pressure Gauges Upto The Exterior Wall Of Pump Room And Erection Of Panel Board Consisting Of Tpicn Switches Starter, Voltmeter, Ammeter, Three Indicator Lamps Capacitor And Laying And Jointing The Cables And Twin Earthing As Per Ie Rules Etc., Complete And Testing The Pumps And Trail Run For 10 Days Including Signing Of Completion Of Reports As Required By Eb Authorities And Finishing The Pipe Holes Including The Foundation Bolts, Nuts And Earth Pits.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. |
| 2 | Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 3 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means |
| 4 | Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9” x 4 1/2” x 3” with class designation of 7.5 conforming to IS 1077-1992 for oundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.In Cement Mortar 1:5 |
| 5 | Providing and laying in position, standardised concrete Mix M-20 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete,improve workability without impairing strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10- 12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 6 | Supplying and errecting for sides & soffits including supports and strutting upto 3.29m height for plane surface in all floors including cost and conveyance and all labour charges etc. |
| 7 | Centring Below GL |
| 8 | Centring Above GL, Roof & Roof Beam |
| 9 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500,Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 10 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 11 | Finishing the top of roof with one course of machine pressed tiles of following size ofapproved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 12 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 13 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 14 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Using anti-skid tiles (Observed Data) |
| 15 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 16 | Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter |
| 17 | Manufacturing, supplying and fixing of Entrance steel door Single leaf covered with the following specification. M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sand witching the CR sheet in between.Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20 kg/sq.m with 300mm height of fixed glazing at top with 3mm thick Pin Headed glass including 3 Nos Steel Parliament Hinges of Size 125mm x 150mm for single leaf shutter to be provided, 6 nos of holdfasts 200mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 3 nos, one at the top, one at lock rail (Inner Side) and the other at the bottom are provided. One aldrop is provided at an appropriate place in the door. 2Nos of handle are to be provided. A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officer. The rate includes cost of all materials, labour, charges,taxes, transportation to site of work, loading, unloading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.40m. |
| 18 | Manufacturing, supplying and fixing in position of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed by the departmental officers. |
| 19 | Provision for electrification arrangements with service connection |
| 20 | Light point SD 17 |
| 21 | Fan point SD 106 |
| 22 | Plug point SD 17 |
| 23 | Tube light SD 88 |
| 24 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 25 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 26 | Providing Black board in two layers with first layer in cement mortar 1:5 (one cement and five crushed stone sand)20mm thick and the second layer in Combination mortar 1:1:6(one cement one lime and six crushed stone sand) 20mm thick and providing band all round the block board in c.m 1:5 (one cement and five crushed stone sand) for 20mm thick and 50mm width including cost of one coat of block oxide paint of approved quality complying with standard specification. |
| 27 | Water supply and sanitary arrangements |
| 28 | 1000 lit tank |
| 29 | 20mm PVC pipe |
| 30 | 20 mm PVC elbow |
| 31 | 20 mm PVC Tee |
| 32 | 75 mm PVC Pipe |
| 33 | 75mm Dia Bend |
| 34 | 110 mm PVC PIPE 6Ksc |
| 35 | 110 mm PVC Bend 6Ksc |
| 36 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 37 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges, etc. complete |
| 38 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers |
| 39 | Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers. |
| 40 | Supplying and Fixing of Unbranded Outdoor Slide With Curved Spiral as Gem portal |
| 41 | Supplying and Fixing of Khelo Kudoo Outdoor Slide with Straight as Gem portal |
| 42 | Supplying and Fixing of Athletic Trends Industries Outdoor Slide as Gem portal |
| 43 | Conducting Geophysical survey, quality and quantity test and transportation charges etc, (This includes labour charges in the field, rent of the vehicle for reaching the place, rent of the instrument and excluding charges for the geologist) |
| 44 | Drilling 150 mm Dia bore well in Hard rock areas anywhere in the state inculding transportation to site of work in hardrock areas inculding labour charges for insertion of MS casing pipe and flushing of borewell and for minutes. ( As per MD TWAD Board Chennai Letter No : F15090/AE/CM/TWAD/2013/ Dated:22/4/2013 ) |
| 45 | Supplying and Fixing of 200 mm Dia of Casing Pipe including all cost and conveyance etc Complete. TWAD SOR Page No : 22 |
| 46 | Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase230 V+/- 10 %,50 HZ +/-5 % |
| 47 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVCinsulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). |
| 48 | Supply and delivery of following 50 mm dia UPVC Column Pipe and GI Pipes and Other Special materials of good quality including cost of materials and labour with cost for coveyence to site etc Complete complying with standard Specifications. etc., |
| 49 | 32 mm dia UPVC Column pipe TWAD |
| 50 | 32 mm UPVC . Elbow |
| 51 | 32 mm UPVC . Union Elbow |
| 52 | 32 mm dia GI Flange set |
| 53 | Bore M.S. Clamp set |
| 54 | Bore Plate |
| 55 | Nylone Rope |
| 56 | 2.5 sqmm 3core Flate Cable |
| 57 | Erection of power pumps in borewell labour charges for erection of twin packer duplextype jet pumps in borewells upto 150 mm dia including fixing of Suction pipe regulatingvalves with jet assembly upto a maximum depth of 30 m and delivery pipe valves pressuregauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three indicator lamps capacitor and layingand jointing the cables and twin earthing as per IE rules etc., complete and testing thepumps and trail run for 10 days including signing of completion of reports as requiredby EB authorities and finishing the pipe holes including the foundation bolts, nuts and earthpits. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender