Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57571271

Tender For Special Repair Of Existing Mes Bldg, Security Lights And Rev Work At Certain Unit Under Ge (A) Jaisalmer At Mil Stn Jaisalmer

Issued by Statutory Bodies & Commissions/Committees · Jaisalmer, Rajasthan
Tender Value
48.49 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
11 days left
EMD
96980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Existing Mes Bldg, Security Lights And Rev Work At Certain Unit Under Ge (A) Jaisalmer At Mil Stn Jaisalmer

BOQ

Name of Work:- SPECIAL REPAIR OF EXISTING MES BLDG, SECURITY LIGHTS AND REV WORK AT CERTAIN UNIT UNDER GE (A) JAISALMER AT MIL STN JAISALMER
Sl. No. Item Description
1Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil
2Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified & directed by Engineer-in-Charge.
3Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge.
4Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
5Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
6Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each, in soil, complete all as specified.
7Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm soft/disintegrated rock complete all as specified and directed.
8Removing excavated soil to a distance not exceeding 50 meter and depositing where directed, at a level n.exc 1.5m above the starting point, complete all as specified.
9Removing excavated material (soft disintegrated rock) to a distance n. exc 50 mtr and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed.
10S&F Plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation filling etc complete all as specified.
11M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge.
12Extra over stone walling for hammer dressing to face stones with maximum depression on face from straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling, Jodhpur type brought upto courses.
13M&L for 40mm thick cement concrete of 1:2:4 type B0 using 12.50mm graded stone aggregate as in Damp proof course to horizontal or vertical surfaces including necessary formwork
14Material and Labour for Hard core of Guage n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface with broken stone boulders complete all as specified and directed.
15Cement concrete type C2 1:3:6 (40mm graded stone aggregate) 100mm thick in sub base concrete of floor etc all as specified and as directed.
16M&L for Glazed ceramic coloured tiles 350x250x7mm/450x350x7mm thick in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 10mm thick screed in CM 1:4 complete all as specified and as directed
17M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15mm thick screed bed in cement mortar 1:6 complete all as directed by Engr-in-charge.
18M&L for Granite 20mm thick table rubbed and polished in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixure of pigment to match with marble shade of Makrana white complete all as specified and as directed
19S&F solid PVC door frame of size 50x47 mm made out of 5 mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with M.S. Square tube suppling and fixing in opening as per specification and drawing
20S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specificationall as specified and directed.
21S & F Aluminum anodised bow handle, bearing ISI mark, fabricated type extruded section of 150mm long complete all as specified and as directed.
22S & F aluminum anodised barrel tower bolts, bearing ISI mark, of extruded section 150mm long complete all as specified and as directed.
23S & F 150 mm over all length of cover plate of floor door stopper, bearing ISI mark, of aluminium alloy body and tongue, anodised with hard drawn steel spring, complete all as specified and as directed.
24S&F anodised aluminium snap grid frame work 605x605mm for false ceiling and hangers 6mm dia, GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long including 12 mm medium density fibre board, exterior grade, fixed to timber framework with screws complete all as specified and directed by Engineer-in-charge. Note :- (i) Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm. (ii) Rate quoted by the contractor shall deemed to inclusive of frame work & ceiling board complete.
25S&F for Anodised aluminium powder ocated window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified etc.
26S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge.
27S&F of 5.5 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares exceeding 0.50 Sqm in each pane complete all as specified.
28S&F for towel rack brass chromium plated 20mm dia D type 60cm long of approved make (eg. Prayag or equivalent) complete all as directed by Engr-in-charge.
29S&F for towel ring brass chromium plated 200mm dia or square in shape of approved make (eg. Prayag or equivalent) complete all as directed by Engr-in-charge.
30S&F 15mm dia medium grade GI tubing with all fittings and fixtures complete fixed to walls, ceilings etc all as specified and as directed by Engr-in-charge.
31S&F 20mm dia medium grade GI tubing with all fittings and fixtures complete fixed to walls, ceilings etc all as specified and as directed by Engr-in-charge.
32Supply and fix complete to walls / ceilings or laid in floors/trenches steel water tubing galvanised medium grade with all fittings of sizes 25 mm bore complete all as specified and directed by Engineer-in-charge.
33S&F for 15mm dia bib taps cast copper alloy chromium plated with crown or capstan head, screwed down, high pressure screwed for iron pipe complete all as directed by Engr-in-Charge.
34S&F for 15mm dia stop valves fancy type cast copper alloy chromium plated screwed down high pressure with crown or capstan head screwed both ends for iron pipe complete all as directed by Engr-in-Charge.
35S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White ) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position complete all as directed by Engr-in-charge.
36S & F for single peice vitreous china wash down water closet (pedestal pattern) pan white with “P” or “S” trap including flushing cistern 10 lts capacity with plug , handle etc. connection to drain or outgoing and to syphonage pipe complete all as specified and directed.
37S&F (Health faucet) with 1 Mtr flexible tube with wall hook bracket etc, complete set of superior quality all as specified and directed.
38S & F for 600 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete.
39S&F for CP Brass toilet paper holder with wall hook bracket etc, complete set of superior quality all as specified and directed.
40S&F soap dish brass chrome plated fancy type
41S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete
42S&F for light colour vitreous china WHB Thin Rim Table top of size 495 x 395 x 150 mm (minimum) including CP waste pipe etc and making holes in the counter for fixing basin and mixer complete all as specified as approved by GE
43S&F CP brass Central Hole Table Top Wash Hand Basin mixture fixed to GI pipe with .M complete all as specified and directed
44S&F in repair 75 mm bore PVC (SWR) single socketed in any length with rubberring joints fixed to walls with clamps or laid in trenches or in floors
45S&F in repair 110 mm bore PVC (SWR) single socketed in any length with rubberring joints fixed to walls with clamps or laid in trenches or in floors
46S&F in repair PVC (SWR) bend any radius of 75 mm bore
47S&F in repair PVC (SWR) bend any radius of 110 mm bore
48S&F in repair PVC (SWR) branch piece, single(single Y), equal or unequal any radius of 75 mm bore
49S&F in repair PVC (SWR) branch piece, single(single Y), equal or unequal any radius of 110 mm bore
50S&F in repair PVC (SWR) vent cowl any radius of 75 mm bore
51S&F in repair PVC (SWR) vent cowl any radius of 110 mm bore
52M& L for PVC (SWR) floor trap of size 75mm, plain with grating including jointing with solvent cement all as directed by Eng-in-Charge.
53S & F in repair CP brass Towel rail 20mm dia, D type, 60 cm long complete fixed in wall with screws complete all as specified and directed by Engineer-in-charge.
54M&L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:3 complete all as specified and directed.
55M&L for PCC (1:2:4) Bo using 12.5 mm graded stone aggregate as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., to achieve requisite slope all as specified and directed.
56Material and Labour for 10mm thick cement plaster in CM (1:3) on RCC roof mixed with water proofing compound levelled to even and smooth without using extra cement.
57M&L for rendering 15 mm thick readymade plaster on inner/outer walls with approved make by adding 17-19% of potable water by weight of material. For thickness above 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3. Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height.
58M&L for rendering 5 mm thick readymade plaster on inner/outer walls with approved make by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3. Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height.
59Material and labour for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer including applying 3mm thick wall care putty over plastered surface for even and smooth finish complete all as specified and as directed by the Engr-in-Charge.
60Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete.
61M&L for Roughly squared jodhpur stone lintels hammer dressed on face and soffits, hoisted, set and pointed in lime mortar 1:3 or cement mortar 1:6 complete, n exc 3m in lengthcomplete all as specified and directed.
62S&F 5cm thick Sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side andset and pointed in lime mortar 1:2 or cement mortar 1:4. complete
63Material & Labour for 75 mm thick PCC 1:3:6 type C-2 (40mm graded stone aggregate as in plinth protection without using extra cement complete all as specified and directed.
64Supply only liquid water proofing compound
65M&L for providing 3 mm thick APP modified memberane over RCC roof with the following specifiations :-
66(a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :-(i) Membrane weight >3.6 Kg/Sqm .(ii) Net wooven polyster weight >160 gm/Sqm(iii) Softening point of membrane > 150o C(iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction(vi) Elongation > 30 %(vii) Impermeability under water pressure > 3 Kg/Sq cm Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane.(d) Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane
67M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation of manholes, filling and mass concrete complete all as specified and directed
68M&L Brickwork with fly ash modular size bricks of class designation 75 (kgf/ sqcm) bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4. complete all as specified and directed
69M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping incl necessary form work finished even & smooth with using pigment in cement complete all as specified and directed
70M&L PCC 1:2:4 type -B1 (using 20mm graded stone aggregate) as in surface channels and drain etc complete all as specified and directed.
71Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds, mitered /stopped ends etc complete all as specified and directed.
72M&L rendering 15 mm thick in CM (1:4) on fair face of brick work/ concrete faces finished even and smooth without using extra cement with using water proofing compound as per manufacturers instructions complete all as specifed and directed. (Note: water proofing compound shall be measured and paid seperately).
73M&L concrete bed of PCC 1:4:8 type C2 using 40 mm graded stone aggregate for 150 mm bore drain pipes bedding & hunching against the sides complete after pipes are laid, jointed and tested complete as specified
74M&L TMT mild steel bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed
75M&L for proving precast cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces placed in position, set in CM(1:6) complete all as specified and directed. Note: Reinforcement shall be measured and paid seperately.
76M&L 150 mm internal dia of reinforced cement concret drain pipe class NP-3 laid in tenches and jointedwith collars specified .
77M&L for On site LLDPE septic tank conventional type for 20 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for finishing same returning filling in of soil LLDPE manhole cover complete all as specified and directed.
78M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20 M dia X 3.00 M deep complete all as specified and directed
79Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
80Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing).
81M&L for vitrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM 1:6 provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as directed (size 600mm to 600mm) complete all as specified and directed.
82M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15mm thick screed bed in cement mortar 1:6 complete all as directed by Engr-in-charge.
83M&L 50mm PCC 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection, sub base of flooring and hard standing including providing contraction joints with wooden spacers complete all as specified and directed
84Taking down chowkhat or frames exe 1.5 sqm but exc 4 sqm each with shutter (without taking off shutter from the frames)
85S&F aluminium die cast body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.
86Dismantling of Ceiling Board of any description and any thickness including Cover Fillets, Cornices, etc complete all as specified and as directed.
87Taking down cement plaster of any description on stone or brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as per directed by Engr-in-Charge.
88M&L for washing/rubbing down and stopping of distempered, plastered and painted surfaces of wall including cornices etc and making good of holes by filling holes in plastered surfaaces with POP mixed with distemper and applying two coat of distemper oil emulsion incl complete removal of existing treatment complete all as specified and as directed by Eng-in-Charge.
89Complete removal of the existing treatment on walls by scraping and washing down with water including making good the surfaces complete all as directed by Engr-in-Charge.
90S&F in repairs Stainless steel tubing of 25 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fency type, stops fixed with ss screws etc all as specified & directed as in repair .Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered.
91S& F in repairs floor door stopper of aluminium alloy body with steel spring 150 mm fixed to door
92Dismantling wall and ceiling boarding of any description, thickness including cover fillets complete al as specified and directed.
93S & F solid PVC Wall Lining consisting of 6mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all respect including supply and fixing of all accessories like fasteners/screws/solvent etc all as recommended by manufacturer all as specified (colour/pattern as approved by Accepting Officer).
94S&F powder coated 50 microns extruded aluminium glazing/ doors & shutters made out of section 63.5x38.10x1.20mm for chowkats or frame & shutters made of size 44.45x44.45x1.29mm for side rails and middle rail, 114.3X44.45X1.29mm for top rails and bottom rails including 5mm thick tinted glass above middle/lock rail (top & bottom) and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beads 20mm size with and incl mortice lock with duplicate keys etc complete all as specified and directed including supply and fixing the following items:(a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 3 nos per leaf.(b) Powder Coated Aluminium Tower Bolt 200mm long - 2 nos per leaf(c) Powder Coated Aluminium Handles 150 mm - 2 nos per leaf
95Providing and fixing powder coated 50 microns extruded aluminium in 3 Tier Track Sliding Windows/glazing, with frame of section 100x44-45x1.30mm, track of size 100x38.10x1.30 & shutters made of size 32x18x1.3mm, with and including 4mm thick tinted sheet glass selected quality fixed in 2 shutters and stainless steel wire gauge 0.36mm nominal dia of wire and average width of aperture 1.40mm in one shutter and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size and also including powder coated 150mm handle with built in locking system for each leaf complete all as specified.
96M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-Note : Modular switch and socket shall be measured and paid separately.
97One light point controlled by one switch
98One exhaust fan point controlled by one switch
99One socket outlet 6 amp controlled by one switch on the same board with other switches.
100One socket outlet 6 amp controlled by one switch on the Independent board with other switches.
101All as per item No 95.00 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase, neutral & earth for power socket point 15 A .
102S&F modular switch one way 6A, 1 module .
103S&F modular socket 6A-2/3 pin combined 2 module.
104S&F modular switch socket combined 6A/16A , 6 pin, 3 module
105S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body.
106Taking down carefully surface aluminium point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
107Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes all as specified.
108M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, PVC casing caping/Concealed PVC conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box thickness as per IS standard (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps.
109One light point controlled by one switch.
110One Ceiling /Exhaust fan point controlled by one switch.
111One socket outlet 5 amp controlled by one switch on the same board with other switches.
112All as per Item No 103.00 here-in-before but for one socket outlet of 05 Amps fixed on independent board WIT 2.5 sqmm
113All as per Item No 103.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified.
114S/F in repair modular switch one way 6A, 1 module .
115S/F in repair modular socket 6A-2/3 pin combined 2 module.
116S/F in repair modular switch socket combined 6A/16A , 6 pin, 2 module
117S&F in repair hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
118S/F in repair Ceiling rose, three terminals PVC/polycorbonate, isolated body.
119S/F vertical DBs VTPN 6 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 54 - IK 09 with metal door, recess mounted, having insulated 200 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP and with provision of SP/TP MCB's of required size as outgoing. Note :- Provn of space for fixing of 160 Amp 4P MCCB.
120S & F for MCB DB SPN 8 way double door IP 54 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed .Make: Legrand/Havells/Indoasian
121S & F in repair MCCB 4P 415 volts 16 KA microprocessor based release suitable for fixing on VTPN DB of capacity 160 Amps with extended terminals complete all as specified. Note:- Suitable size and frame of MCCB required as per existing DBs at site.Note MCCB Rating ICS=100 % ICU
122Supply and fixing in repair MCB's single pole and neutral 40 to 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve.complete all as specified & directed.
123Supply and fixing in repair MCB's single pole 06 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve.complete all as specified & directed.
124S&F in repair submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in PVC casing caping/Concealed pvc conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete including taking/down all as specified and directed by Engr-In-Charge.Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length.
125S&F in repair building security light fitting LED 35/36 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment etc and connecting as specified and directed .
126S& F in repair bracket of GI pipe medium grade of 40mm dia ,1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts ,bolts & washers,painting complete as specified .
127S&F in repair LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
128S & F in repair of LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified and directed.
129Supply and fixing of recessed/ceiling/surface/POP mounted down lighter with CRCA housing with high bright LED,idealy suited for low ceiling areas 36 watt LED (100 Lumen/watt or higher) , size 2ft x 2ft The product features color tuning from 3000 K to 6500 K, necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified.
130Taking down and refixing at required place of LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr in Charge.
131Taking down U/S ceiling fan/exhaust fan of any sweep sealing cable end dismanting blade and removing fan and blade to store complete all as specified and directed. Note :- Old u/s fans shall be deposited at MES Store.
132Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
133M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge.Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length.
134S & F for MCB DB SPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed .
135Supply and fixing MCB's single pole and neutral 40 to 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve.complete all as specified & directed.
136Supply and fixing MCB's single pole 06 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve.complete all as specified & directed.
137Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
138Supply only 12 watt black gold finish straight bar LED picture photo frame/wall miror vanity/bathroom dressing table (white/warm white) complete all as per site requirement.
139Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
140S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fancy type and fixed 15 mm dia and fixed all as specified and directed.
141M&L for PVC connection pipe chromium plated 15 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 450 mm suitable for Hot/ cold water system complete all as specified & directed by Engineer-in-charge.
142S&F Stop valves, cast copper alloy,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete of size 15 mm dia all as specified & directed by Engineer-in-charge.
143S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amp all as specified.
144M &L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 15 mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle, funnel and wire mesh etc and testing on complete all as specified and directed Engr-in-Charge.
145M & L repair of bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 15 mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle , funnel and wire mesh etc and testing on complete all as specified and directed Engr-in-Charge.
146Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers
147M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with 4.00 mm dia GI wire size complete all as specified and directed Engg-in-Charge.
148M&L for GI Tubing light grade 15 mm dia.for cable protection complete all as specified and directed Engg-in-Charge.
149S&F Gun-metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 20 mm bore with ISI marked and as per IS 14846 complete all as specified and directed by the Engineer-in-Charge.
150S&F Gun-metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 25 mm bore with ISI marked and as per IS 14846 complete all as specified and directed by the Engineer-in-Charge.
151Cutting the existing 50mm pipe CI/GI & inserting the Tee 50x50x25mm complete all as specified and directed by Engineer-in-charge.
152Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 40 mm outer dIa 32 mm bore as per is 16205 part 24 cable protectionincluding all fitting as required complete all as specified and directed by engineer- in-charge.
153Taking out LT UG cable of any size/any core as directed by engr in charge
154Supply ,laying, test and commissioning in repair of LT UG ,XLPE insulated, heavy duty, 1100V grade of size 10 Sqmm 4 core electric cable with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands, lugs,bushing etc as required complete all as specified and directed by Engineer-in -Charge of following size:-Note: Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items complete all as specified & directed by Engr-in-Charge.
155All as per item No 146.00 above but size 16 Sqmm 4 core
156All as per item No 146.00 above but size 25 Sqmm 3.5 core
157Supply & fix in repair 40 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified and as directed.
158Material and labour for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge.
159Material and labour for preparation of old painted surface of LT Concrete electric pole of any size by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height 1.5 mtr above the ground level, including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge.
160Supply and Fixing Led Street Light Of Capacity 60 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 100 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have ptted type and Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge
161Supply & Fixing only, galvanised iron bracket of 'light grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer Taking And Down Old unserviceable iron brackets complete for fixing street light fittings all as directed by Engr-in-Charge.
162Supply and Fixing of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and taking down old unsv and complete all as specified.
163Supply and fix of PVC insulated, sheathed weather proof, Copper conductor of size 1.5 Sqmm sqmm, 3 core Including Disconnected & Taking Down Old Unserviceable complete all as specified And directed by engr-in-charge.
164S&F in repair Nature switch (using infrared sensor technology) based automatic street light control panel. The panel should be enough to take three phase load of 8 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is <=60 and for Switching OFF >=10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 8 KW with 3 nos contactor 32 Amp ,3 nos Incoming MCBs of 40 Amps and outgoing MCBs of 40 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof, Electric shock proof, Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation complete all as specified and directed by Engr-in-Charge.
165Material and labour for cutting the existing bituminious road / hard standing to size not exceeding 45 CM wide and depth not less than 45 cm for passing UG cable through GI pipe and making good the good distrubed surface and filled excavated material and 200 mm depth with plane cement concrete 1:3:6 type C1 using 20 mm graded aggregate complete all as specified and directed by Engr -in- charge
166Supply and fix in repair circular top for 80mm GI pipe fix with welding (height of pole 9 mtr) Complete all as specifed and directed by Engr-in-Charge.
167M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified.
168S&F feeder pillar box out door type not less than 0.60 M x0.60 M x0.60 M made out of 3.15 mm thick CRCA sheet powder coated dust & vernin proof supported on angle iron frame 40x40x5 MM , with Incoming MCCB 4 pole, 200 Amp 415 Volts , 36 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu) and outgoing MCCB 160 Amp -01 nos ,and MCB TPN 63 AMP,4 pole -01 Nos luminium bus bar 04 Nos vertivally fitted Aluminium strips rated capacity 300 Amp for netural supported on porcelain insulators including painting with two coats red oxide primer and pcc foundation including taking down of existing feeder pillar box complete all as specified and directed by Engineer-in-charge.
169Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) complete all as specified and directed by Engr -in- charge
170M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engr-in-Charge.
171M & L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of stay assembly including necessary form work all as specified and directed by Engr-in-Charge.
172M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57571271
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.49 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Existing Mes Bldg, Security Lights And Rev Work At Certain Unit Under Ge (A) Jaisalmer At Mil Stn Jaisalmer
Basic Detail
Tender No 8590/26-27/E8
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 17 Sep 2026
Submission Date 01 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 48.49 Lakhs
Tender Fee 500
EMD 96980
Exemption Available
Document List
BOQ_885504.xls
e8f7bc74-8b25-4d56-b5cb-70abe99e919e.html
TenderDocuments8590.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_885504.xls

html

e8f7bc74-8b25-4d56-b5cb-70abe99e919e.html

pdf

TenderDocuments8590.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender