Tender For Repair/ Maintenance Of E/M Installations And Allied Works At Drass Under Ge Kargil
Tender Overview
Project Description
Tender for Repair/ Maintenance Of E/M Installations And Allied Works At Drass Under Ge Kargil
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Oct-2026 | DATE | Date | 17-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises., complete all as specified and directed by Engr-in-Charge. |
| 2 | Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L for 75mm thick, PCC type D-2 1:3:6 (using 40mm graded stone aggregate) as in sub base flooring, Hardstanding, surface finished even and rough to receive floor topping or similar works complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for 25 mm thick PCC type B-0 (12.5mm graded stone aggregate) 1:2:4 as in floor or similar works complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for Joint free Non-skid coloured ceramic tiles 7 to 8mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L Joint free Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 and n.exc 0.38 Sqm in floors over 15mm thick screed bed in cement mortar 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for Coloured Glazed ceramic tiles of size 300x450x7 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 10 mm thick rendering in CM (1:3), complete all as specified and directed by Engr-in-Charge. |
| 8 | Dismantling of Stone sett paving of any description or thickness in floors, aprons etc. laid dry or laid dry and pointed complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over 25mm thick sand cushion complete all as specified and directed by Engr-in-Charge. (Note- Sand cushion measured and paid seperately) |
| 10 | M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engr-in-Charge. |
| 11 | Demolition of Brickwork or stone/boulders masonry built in any cement mortar complete all as specified and as directed by the Engr-in-charge |
| 12 | M&L for precast cement concrete type B1 1:3:6 (using 20mm graded aggregate) block masonry with soild block, exc 10cm width and setting in cement mortor 1:6 complete all as specified and as directed by Engr-in-Charge |
| 13 | Taking down cement plaster on Brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L rendering 15mm thick in CM 1:6 on other fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for preparation of new plastered surfaces on walls and applying two coats of Oil bound emulsion paint over a coat of primer complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for preparation of old plastered surfaces of walls and applying one coat of Oil Bound distemper of approved tint, complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for preparation of new plastered surfaces on walls and applying one coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 19 | M&L for preparation of old plastered surfaces on walls and applying two coats of cement based paint complete all as specified and as directed. |
| 20 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge. |
| 21 | Dismantling timber scantling as in fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section in framed work, in any position complete all as specfied and as directed |
| 22 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 6 Sqcm but not exceeding 13 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed |
| 24 | S&F 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed by Engr-in-Charge. |
| 26 | Taking up or down steel water tubing of 20mm dia bore and connection incl cleaning for refixing or removal to stores all as specified and as directed |
| 27 | Taking up or down steel water tubing of 25mm dia bore and connection incl cleaning for refixing or removal to stores all as specified and as directed |
| 28 | M&L for 20mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed to walls, ceilings or in floors etc complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for 25mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed to walls, ceilings or in floors etc complete all as specified and directed by Engr-in-Charge. |
| 30 | Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of specified colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge |
| 32 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of specified colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge. |
| 34 | M&L Rolled mild steel Fe 290 (Gde E-165) for roof trussed (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F for joists, channel, angle or tee sections fixed independently with out connecting plates Fe 290 (Gde E-165) complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F Mild steel rag or lewis bolts screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised length of bolt exc 15 cm and not exc 30 cm long and neck diameter 12mm complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L prepation of new or previously untreated surfaces of steel and applying two coat of Synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge |
| 38 | M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 39 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc complete all as specified and directed by Engr-in-Charge. |
| 40 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5 Sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2 mm thick PVC casing caping with all accessories and 1.5 Sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate, flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer point controlled by one switch. |
| 41 | All as per Srl item No 40.00 here in before but for one 3 pin 5 Amps switch socket on same board. |
| 42 | All as per Srl item No 40.00 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 43 | All as per Srl item No 40.00 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 44 | S&F in replacement switch piano flush type 5 Amps, single pole one way. |
| 45 | S&F in replacement socket outlet 2 in 1, 6 Amp flush type |
| 46 | S&F in replacement switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type. |
| 47 | S&F in replacement switch socket combination 2 in 1, 5 and 15 Amps flush type. |
| 48 | S&F in replacement ceiling rose surface bakelite 65x50mm, two to three terminals. |
| 49 | S&F in replacement lamp holder, insulated body with back plate suitable for batten fittings |
| 50 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 4 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 52 | S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 53 | S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 54 | S&F in replacement 1100 volts grade heavy duty 6 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-in-Charge. |
| 55 | S&F in replacement 1100 volts grade heavy duty 10 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-in-Charge. |
| 56 | S&F in replacement 1100 volts grade heavy duty 16 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-in-Charge. |
| 57 | S&F in replacement LED 1x18 Watt, 220 V, Cool Daylight (6000-7000K) , AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as speicifed and directed. Make- Havells/Crompton/Polycab or equivalent |
| 58 | S&F in replacement LED 1x18 Watt, 220 V, Warm White (3000K) , AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as speicifed and directed. Make- Havells/Crompton/Polycab or equivalent. |
| 59 | S&F in replacement exhaust fan, steel body, AC single phase, 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed by Engr-in-Charge. |
| 60 | S&F in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F in replacement of LED Flood light fitting 70 watt 5000K, 125 lm/w, natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver with toughtened glass including all connected accessories complete all as specified and directed by Engr-in-Charge. |
| 62 | S&F in replacement of LED Flood light fitting 120 watt 5000 k,125 lm/w, natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver with toughtened glass including all connected accessories complete all as specified and directed by Engr-in-Charge. |
| 63 | S&F as in repairs MCCB, 63A, rupturing capacity 16 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge. |
| 64 | S&F as in repairs MCCB, 125A, rupturing capacity 16 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 65 | S&F as in repairs MCCB, 160A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 66 | S&F as in repairs MCCB, 250A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 67 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 320 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 68 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 200 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 69 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 100 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 70 | S&F in replacement PVC casing caping size 32 mm x 12 mm medium grade ISI mark including accessories to fix on wall/Poles complete all as specified and directed |
| 71 | Excavating in trenches in Hard and dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and directed by the Engr-in-Charge. |
| 72 | Returning , filling in , including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed by the Engr-in-Charge. |
| 73 | Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engr-in-Charge |
| 74 | M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I. |
| 75 | Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm laid dry over electric cable for protection complete all as specified and directed by the Engr-in-Charge |
| 76 | Taking out defective Various sizes of cable XLPE/PVC sheathed 1100 volt/11000V grade heavy duty armoured with aluminium conductor from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed by the Engr-in-Charge. |
| 77 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 300 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts, clamps and accessories complete complete all as specified and directed by the Engr-in-Charge. |
| 78 | M&L for boring of holes under road pavment/hard standing by manual boring including making good to the distrubed surfaces complete all as specified and directed |
| 79 | Supplying and laying as in repairs GI tubing light grade of size 80 mm bore incl all accessories for passing of cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works complete all as specified and directed by the Engr-in-Charge. |
| 80 | Supply and fix in repair 3 phase Busbar chamber suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system,wall mounted type, 200A, 6 no. copper strip, busbar made of ETP grade copper fixed on wall/angle complete all as specified and directed. |
| 81 | Note : Deduction for amount of Rs. 48,855.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender