Tender For Improvement To Electric Supply Installations Incl Certain Misc Wks Under Ge Nasik Road C
Tender Overview
Project Description
Tender for Improvement To Electric Supply Installations Incl Certain Misc Wks Under Ge Nasik Road C
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying pipe line / cables etc and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | All as per item No 01 above but depth exc 1.5m upto 3 m. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 4 | Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 5 | Disconnecting & taking out cable LT 1100V grade any size complete all as specified. |
| 6 | Supply, laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 2 core 6 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and as directed. |
| 7 | All as per Ser item No 6.00 above but 2 Core 10 Sqmm |
| 8 | All as per Ser item No 6.00 above but 3.5 Core 35 Sqmm |
| 9 | All as per Ser item No 6.00 above but 3.5 Core 50 Sqmm |
| 10 | S&F in repair glow sign board of size 2x1x0.30 m for fixing at MES installations fabricated out of two side polycarbonate unbreakable sheet LG vinyl cutting duly framed with 18 SWG GI sheet and suitable angle iron frame of not less than 35x35x3mm errected at a height of 1.5m from ground level duly embedded in PCC. The sign board to be written in bold letters of standard size as per sample approved by Engineer in Charge, duly fitted with 2x10 Watt LED invertor tube light fittings with prewired and connected to the street light feeder through one three core PVC insulated copper conductor cable 1.5 sqmm drawn through MS conduit of 20mm dia to avoid mechanical damage on ground and raising on sign board or street light pole or Bldg for MES INSTALLATIONS complete all as specified and as directed. |
| 11 | Supply, fixing and commissioning Auxilliary Voltage transformer for RMU of Crompton make complete with following specifications including taking down old transformer:- VTR : 11000/ 3/230/ 3 V ACBurden : 500VABIL : 28kVrms/75kVpKHRCA fuse at the primery sideCopper PT connection VT12, MGVCL, 12 RMU - 01 NoCopper PT connection 2 VT12, MGVCL, 12 RMU - 01 NoHT Tape (Scotch Tape) - 01 NoCable copper conductor 2.5 Sqmm black - 10 RMHardware Set - 01 Set |
| 12 | M&L for disconnecting existing solar street light fittings carefully from bracket/pole, opening the fitting and Supply, fixing & commissioning of Lithium Ferro Phosphate (LiFePO4) battery suitable for 50-Watt (Solar light Make: Wipro and Halonix). Battery specification 12.8V 30Ah to 36Ah Lithium Ferro Phosphate (LiFePO4) battery. Battery is ideal because it lasts longer, handles hot weather, and can power the light for 12 to 15 hours, including during cloudy days complete all as specified and directed. |
| 13 | M&L for complete removal of existing treatment for preparation of old decorated treatment on wall / ceiling of Sub Stn Buildings by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint over a coat of weather proof primer with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturer's instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.MAKE :- Apex Ultima Protek Asianpaints/ Nerolac excel top guard / Berger weathercoat long life 10 |
| 14 | NOTE FOR PAINITNG ITEM :-The following precautionary measures shall be ensured by the contractor before and during execution of the work :- (i) All the painting works shall be got executed through original material manufacturing company or their authorised applicators as approved by GE and contractor should submit MOU with the manufacturing company or their authorised applicator before execution of work and entire work shall be executed with the approved firm.(ii) Contractor shall deposit entire quantity of materials (proprietory materials) in sealed containers required for painting works covered under subject contract in the custody of Engineer-In-Charge.(iii) The materials as required shall be issued to contractor by JE/ Engineer-In-Charge on daily basis and the empty containers/ bags shall be deposited in the store of Engineer -In-Charge by the contractor, for verification as per standard consumption/ coverage prescribed by the manufacturers.(iv) After completion of painting work contractor shall remove and clean all the droplets/stain of paint left on the floor, glasses and joinery etc.(v) The Painting shall be carried out for OH Tanks up to 16 to 21 m contracor. Quotated rates includes the Charges of scaffolding. |
| 15 | Supply, laying, jointing and testing 3 core 95 sqmm XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 11000 Volts grade lay in trenches, ducts, along pole, along transformer complete all as specified and as directed. |
| 16 | Supply, fixing and connecting Cable jointing kit for 11 kV (Earthed) grade cable for outdoor straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed. |
| 17 | M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and as directed. |
| 18 | M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and innter dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90 mm suitable for cable protection of size 70 sqmm to 185 sqmm cable complete all as specified and as directed. |
| 19 | S&F in repair PVC weather proof, hinged door, junction box with, 240V, Neutral link and 1 No MCB SP of 6 Amps, necessary fixing arrangement such as 32x5mm clamps, nut, bolts, etc including dismantling old unservieable junction box all as specified and as directed.Make : Sintex, Cat No. GSJB 2014 or equivalent of Hensel/ National. |
| 20 | Dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc. |
| 21 | Supply and laying in repair synthetic rubber insulated mats 2 mm thick for Voltage upto 3.3 kV for electrical purpose as per IS-15652-2006 suitable for electrical shock safety of size 2x1m complete all as specified and as directed. |
| 22 | Supply, install, erect steel tublar seweaged welded poles complete with MS base plate of 6mm thick of size 300x300mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 11 m long 410 SP-55, fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete including taking down old pole complete all as specified and as directed. |
| 23 | Demolition of PCC of any description above/below ground level exceeding 15cm complete all as specified and as directed. |
| 24 | M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etc all as specified and as directed. |
| 25 | M&L for PCC 1:2:4 type C1 using 20mm graded aggregate for coping including necessary form work with fair finishing of exposed surface of concrete all as specified and as directed. |
| 26 | S&F in repair galvanized earth strip 32x6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 m interval all as specified and as directed. |
| 27 | S&F in repair angle iron post for chain link fencing, cross arms. Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts, washers, welding, bending, cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and as directed. |
| 28 | Supply only in repair chain link fencing MS galvanised, any size or type complete all as specifed and as directed. |
| 29 | Fixing only chain link fencing icluding line wires any mesh size and type of standard rails straining bolts etc including provision of binding wire complete all as specified and as directed. |
| 30 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI wire 4.0 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion and taking down old earthing”.Note: These earthings shall be provided for poles; without provision of concrete earth pits. |
| 31 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI strip 32x6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion and taking down old earthing”. |
| 32 | Supply and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for Voltage upto 11 kV for electrical purpose as per IS-15652-2006 suitable for electrical shock safety of size 2x1m complete all as specified and as directed. |
| 33 | Supply and laying in replacement of synthetic rubber insulated mats 3 mm thick for Voltage upto 33 kV for electrical purpose as per IS-15652-2006 suitable for electrical shock safety of size 2x1m complete all as specified and as directed. |
| 34 | S&F repair Air termination single pointed aluminium rod 12mm dia and 300 mm long complete all as specified and directed |
| 35 | S&F repair Air termination single pointed copper rod 12mm dia and 300 mm long complete all as specified and directed |
| 36 | M&L for cleaning/clearing of vegitation around the installations and disposing off as directed. |
| 37 | M&L for stone aggregate 40mm graded spreading and leveling aroung 2 pole/ 4 pole structure where GOD installed including well ramming complete all as specified and directed. |
| 38 | M&L for replacement of Lightening arresters station class complete with all fittings, station class, discharge capacity 65 kA, suitable for 11000 Volts all as directed. |
| 39 | M&L for replacement of Lightening arresters station class complete with all fittings, station class, discharge capacity 65 kA, suitable for 33000 Volts all as directed. |
| 40 | M&L for preparation of old distempered wall surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and effrosecent salts and trading oil and greasy spots and applying a coat of distemper oil emulsion any tinted complete all as specified and as directed. |
| 41 | All as per item No 40.00 above but on ceiling. |
| 42 | M&L for preparation of old surface any type of surface wall and ceiling and aopplying 1.5mm thick wall thick wall care putty complete all as specified and as directed. |
| 43 | M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 44 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 45 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed. |
| 46 | M&L for rendering 10mm thick in CM 1:4 as in backing coat, finishing even and smooth without using extra cement complete all as specifeid and as directed. |
| 47 | M&L for colour glazed cermic tiles 300x450x7mm thick or above size in vertical surface, set and jointed in neat cement slurry & pointed with coloured cement to match laid over and including rendering 10mm thick in CM 1:4 as in backing coat on fair surfaces of brick wall. |
| 48 | Demolition of un-reinforced cement concrete in ground floors or pavings n.exc 15cm thick (below or above level) complete all as specifed and as directed. |
| 49 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base complete all as specifed and as directed. |
| 50 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) as in level course finished even and rough with out using extra cement complete all as specifed and as directed. |
| 51 | M&L for screed bed or bedding layer 15mm thick in CM 1:4 for laying floor finished complete all as specified and as directed. |
| 52 | M&L for 40mm thick PCC 1:2:4 type B-1 using 20mm graded aggregate finished even and smooth with using extra cement all as specified and as directed. |
| 53 | M&L for glass dividing strips, 3mm thick, 38mm width and inserted in position to conform to design complete all as specifed and as directed. |
| 54 | M&L for Non-skid coloured ceramic joint free tiles 400x400x7 to 8 mm thick or above size (square/rectangular) in flooring etc. laid over screed bed 15 mm thick in CM 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match. |
| 55 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed. |
| 56 | M&L for rounding to edges of stones slabs one edge, such as in steps, cooking platform and other simlar situations. |
| 57 | M&L for 60 mm thick M-35 grade precast colored cement concrete interlocking paving tiles rubber mouleded of any size and shape confirming to IS 15658-2006 and ISI marked as in pavement laid on 50mm thick stone dust cushion laid dry all as per manufacturers instructions complete all as specified and directed. Please Enable Macros to View BoQ information |
| 58 | M&L for 60 mm thick M-35 grade precast colored cement concrete interlocking paving tiles rubber mouleded of any size and shape confirming to IS 15658-2006 and ISI marked as in pavement laid on 50mm thick stone dust cushion laid dry all as per manufacturers instructions complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender