Tender For Repair/Maintenance Of Ht/Lt Switch Gears, Panels,Transformers, Cables And Connected Works At Dmde Area,Vvra,Sera And Ce R&D Area Under Age E/M.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
14 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Ht/Lt Switch Gears, Panels,Transformers, Cables And Connected Works At Dmde Area,Vvra,Sera And Ce R&D Area Under Age E/M.
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick using soil complete all as directed. |
| 3 | Removing excavated material to a distance exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as directed. |
| 4 | Supply and spreading natural dry, clean river sand in trenches for cushioning of cable complete all as directed. |
| 5 | M&L for brick protection with common burnt bricks sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed. |
| 6 | S&F unreinforced precast concrete cable cover class HV type 1 flat of size 300mmx 180mm x 40mm complete all as directed. |
| 7 | Supply, laying, testing and commissioning of Cable with Stranded Compacted Circular Aluminium Conductor, 11000Volts, UE, Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated, Insulation Screened with extruded semi-conducting compound in combination with copper tape cores laid up, inner sheath of Thermoplastic tape, galvanised flat steel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable conforming to IS:7098/II/85 of size 120 sqmm, 3 core with appropriate lugs including taking down unserviceable cable complete all as directed. |
| 8 | All as per item No 7.00 here-in-before but 95 sqmm 3 core complete all as directed.Make for item srl No 10 &11 - Havells/Universal/Gloster/Polycab |
| 9 | M&L in repairs for cable jointing kit for 11000Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as directed. |
| 10 | All as per srl item No 9 here-in-before but 50 sqmm to 95 sqmm all as directed. |
| 11 | M&L in repairs for cable jointing kit for 11000Volts (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as directed. |
| 12 | All as per item No 11 here-in-before but 50 sqmm to 95 sqmm all as directed.Make for item srl No 09 to 12 : Raychem/M-Seal/3M |
| 13 | M&L for GI tubing of 100 mm bore 'Light Grade' for protection of HT cable with all fixing accessories laid in trenches/walls including taking down unserviceable GI tube complete all as directed. Make:Jindal/Tata/Zenith |
| 14 | M & L for provinding of standby rented transformer of suitable capacity after receiving the complaint of non working of existing transformer of capacity 100 KVA to 315 KVA within 12 hrs of time frame before taking the existing transformer to the workshop from the site. The job included disconnection the existing transformer and shifting of rented transformer in place of the existing transformer including electric connection. Till the existing transformer get repaired/rewinding of the transformer done at workshopthe rented transformer should be inside in good condition as per the satisfaction of Enginner-in-Charge |
| 15 | M&L for cutting and removing grass, plants, bushes of the 2/4 pole structure area including surrounding of transformer plint and dispose the cut grass, plants, bushes to be taken out or destroyed by the contractor to a distance exceeding 2 KM from the site of work complete all as specifief and directed by Engr-in-Charge. |
| 16 | M&L for spreading and leveling of 40mm graded stone aggregate over stone dust (0-3mm) in transformer yard complete all as directed by Engr-in-charge.Note : After ramming stone dust layer will be of minimum 25mm thickness |
| 17 | M&L for Cutting and removing tree branches of any height and of any size, hanging on HT/LT lines, street lights, and the cut tree branches / trimming and shall be removed to a distance exceeding 2 km and not exceeding4 Km from the site of work complete all as directed |
| 18 | Cutting the road /hard standing to a size not exceeding 45 cm in width and not exceeding 75 cm in depth for laying / removal of LT/HT UG cable /protection pipe including making good so as to match with existing finishing with PCC (1:4:8) type D2 (using 40mm grade stone aggregate) for 100mm thick on top including fair finishing complete all as directed. |
| 19 | S&F Laying LT UG cable heavy duty armoured with aluminum conductor multistranded PVC insulated and sheathed with suitable lugs including taking out old unserviceable cable complete all as directed for following sizes: - |
| 20 | 3.5 core 25 Sqmm. |
| 21 | 3.5 core 35 Sqmm. |
| 22 | 3.5 core 50 Sqmm. |
| 23 | 3.5 core 70 Sqmm. |
| 24 | 3.5 core 95 Sqmm. |
| 25 | 3.5 core 120 Sqmm. |
| 26 | 3.5 core 185 Sqmm. |
| 27 | 3.5 core 240Sqmm. |
| 28 | 3.5 core 300 Sqmm.Note: - .Excavation & earthwork, sand cushioning and brick protection shall be measured and paid seperately under relevant items.Make for item 19.01 to 19.09 : Havells/Universal/Gloster/Polycab |
| 29 | S&F in replacement Alluminium lugs of following sizes:-Make : Dowell/Jainson |
| 30 | 240 sqmm |
| 31 | 185 sqmm |
| 32 | 95 to 120 sqmm |
| 33 | 50 Sqmm |
| 34 | 16 to 35 Sqmm |
| 35 | 10 Sqmm |
| 36 | S&F MCCB four pole 250 Amps, 415 volts 36 KA, including taking out old unserviceable MCCB complete all as directed. |
| 37 | S&F MCCB four pole 160 Amps, 415 volts 36 KA, including taking out old unserviceable MCCB complete all as directed. |
| 38 | S&F MCCB four pole 100 Amps, 415 volts 16 KA, including taking out old unserviceable MCCB complete all as directed. |
| 39 | S&F MCCB four pole 63 Amps, 415 volts 16 KA, including taking out old unserviceable one complete all as direced. |
| 40 | S&F Change over switch 200 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed. |
| 41 | S&F Change over switch 320 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed. Make for Item srl No : 21 to 26 - Havells/Standard/L&T/CG |
| 42 | Supply and fixing switch Air break Gang operated triple pole mechanically operated with GI operated rod, insulator (wire isulator type) and steel frame with operating mechanisim worked from ground level verticle/Horizontal type, for current rating upto 200 Amps, HT 11000 volts including locking arrangement with six lever lock and painting the steel surfaces with two coats of aluminimum paint over a coat of red oxide primer including taking down unserviceable switch air break complete all as directed. |
| 43 | Supply and install Horn gap fuse assembly (solid core insulator type) and steel frame etc suitable for HT 11000 Volts with HT fuse element upto 50 amps including taking down unserviceable fuse assembly complete all as directed. |
| 44 | Supply and fixing drop out expulsion fuse assembly single pole mounted on insulator (two isulator type) and steel frame etc suitable for HT 11000Volts grade with burried fuses & HT fuse element up to 50 Amps including taking down unserviceable drop out expulsion fuse assembly complete all as directed. |
| 45 | M&L for lightining arrestor for outdoor fuse expulsion type complete with all fittings, transmission class earthed system discharge capacity 65 KA suitable for 11000 volts grade including taking down unserviceable lightining arrestor complete all as directed.Make for item srl No 27 to 30 : OBLUM/British Electric/ LET/Lanco |
| 46 | M&L for Aluminum conductor, steel reinforced (ACSR) of size 6/2.11 mm (rapid) not exceeding 2 mtr long for jumper connection between lightning arrester and pin insulator, pin insulator and AB switch, AB switch and HG fuse, drop out expulsion to transformer, including necessary lugs, binding wire, heavy duty PG clamps, PVC sleeves with R, Y, B colour code inlcuding taking down unserviceable aluminium conductor complete all as directed.Make: - Raychem/Transpower/Denson |
| 47 | M & L danger notice plate of 1.6mm thick Mild steel sheet vitreous enameled white, with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20cm size including taking down unserviceable danger notice plate complete all as directed. Please Enable Macros to View BoQ information |
| 48 | M & L danger notice plate of 1.6mm thick Mild steel sheet vitreous enameled white, with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20cm size including taking down unserviceable danger notice plate complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender