Tender For repair maintenance Electrical And Mechanical Services At Vikas Bhawan-Ii, Delhi. (Sh :- Installation Of Video Conferencing, Ac In Conference Hall At Company Secretary Branch, Geospatial Delhi Ltd. Department I/C Replacement Of Damaged Swit
Tender Overview
Project Description
Tender for repair maintenance Electrical And Mechanical Services At Vikas Bhawan-Ii, Delhi. (Sh :- Installation Of Video Conferencing, Ac In Conference Hall At Company Secretary Branch, Geospatial Delhi Ltd. Department I/C Replacement Of Damaged Switch, Socket, Lan Port, Fittings In Various Offices).
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required. |
| 2 | Group C |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. |
| 4 | Group C |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 4 sq. mm |
| 8 | 3 x 6 sq. mm |
| 9 | Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 10 | 2 Pair |
| 11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | 20 mm |
| 13 | 25 mm |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | 5/6 amps switch |
| 16 | 15/16 amp switch |
| 17 | 3 pin 5/6 amp socket outlet |
| 18 | 6 pin 15/16 amp socket outlet |
| 19 | Telephone socket outlet |
| 20 | 25A modular SPMCB |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 23 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 24 | 1 or 2 Module (75mmX75mm) |
| 25 | 3 Module (100mmX75mm) |
| 26 | 6 Module (200mmX75mm) |
| 27 | 12 Module (200mmX150mm) |
| 28 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 29 | 1 or 2 Module |
| 30 | 3 Module |
| 31 | 6 Module |
| 32 | 12 Module |
| 33 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 34 | Supplying and fixing call bell suitable for single phase, 230 volts, complete as required. |
| 35 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim |
| 36 | 12 -15 watt |
| 37 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 38 | 36 watt |
| 39 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 40 | 36 watt |
| 41 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 42 | 150 watt |
| 43 | Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cut off and 50 hz, 1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll/ rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc. as required complete in all respect as specified of following capacity. Sound level of up to50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate upto 50 Degree C (out door ambient temperature). Inverter Type |
| 44 | 1.5 TR with fixed speed 5 Star BEE rating |
| 45 | Supply, Installation, Testing and Commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type - Cooling only |
| 46 | 1.5 TR with 5 Star BEE Rating |
| 47 | 2.0 TR with 5 Star BEE Rating |
| 48 | Supplying, Installation, Testing and commissioning of CAT6Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability. |
| 49 | Supplying, Installation, Testing and commissioning of RJ45Connector for CAT 6/6A Cables. RJ45 modular plug supports 4twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color. Use for 24- 26 AWG stranded wires. |
| 50 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5 Kg |
| 51 | 1 Run of cable |
| 52 | Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd. |
| 53 | 1200mm, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum) |
| 54 | Supplying and fixing of 32 x 12.5 mm DLP PVC trunking along with angle/bend, end cap & other accessories as required |
| 55 | Supplying and fixing of 100 x 50 mm DLP PVC trunking along with angle/bend, end cap & other accessories as required |
| 56 | Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd. |
| 57 | Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd. |
| 58 | Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd. |
| 59 | Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required. |
| 60 | Supplying, Installation, Testing & Commissioning of self contained storage type water cooler suitable for operation on 230 V single phase A.C. supply having following capacity per hour cooling capacity & storage capacity with SS304 stainless steel body, air circulation R-32/R-410 /R-407/ R134a Green Refrigerant with Scroll / rotary compressor with min 5 year OEM warranty of compressor, water over flow 1/2 BSP (connections) i/c MS Angle Iron Stand of suitable size, complete and other accessories i/c connection testing etc as reqd. |
| 61 | storage 150 ltr, cooling capacity 150 ltr per hr |
| 62 | Supplying, Installation, Testing & Commissioning of 65 inch interactive touch display with latest Android 14 OS, CPU : quad core cortex A-73@ 1.4 Ghz, RAM 8 GB, Storage : 128 GB, Pixel Pitch 0.4935 x 0.4935, Response 8 ms, Resolution : 3840 (H) x 2160 (W), Contrast ratio : 1200 : 1, Brightness : 400 cd/ m sq, Viewing angle : 178 deg (H) x 178 deg (V), 9H toughened glass, 60000 hrs screen life, screen recorder, Type -C port, 2 x 20W speaker, Bluetooth connectivity, Anti Glare screen, 20 point Multitouch, Essentials App : Whiteboard, Annotate, Timer, Calculator, Split Screen, Record, Spinner, Screen Record, Screen Share, Browser, PDF reader, Media Player, Screen Cast, built in wi-fi complete with Mounting Bracket |
| 63 | SITC of video conferencing which Adopt the most advanced image DSP and Sony 1/2.8” 8MP sensor, high quality 8MP optical full glass lens, to deliver ultra-high definition and crisp image.* Support max 3840x2160@30 UHD resolution* 4x digital zoom* 120 degree view angle without distortion* Power via USB, a single USB2.0 cable for video output, camera control and power supply directly, friendly-use and flexible operation.* Fast video switch: only 1 second.* Unique and patent camera housing and mechanism design.* With built-in dual microphone, pick up distance 5meters * Electronic pan/tilt design, no mechanism problem* Support WDR, 3D noise reduction* Support image flip function, camera can be installed upside down. VC hardware should be i5 or better processor with miunimum 3 x USB ports , 1 x HDMI output for connection with switcher. It should have all required cables, intercoonection patch cords etc and nothing shall be paid extra to make the same operational etc as reqd. |
| 64 | Supplying, Installation, testing of commissioning of 75 XL Desert Air Cooler For Home with Honeycomb Pads, Powerful +Air Fan, i-Pure Console and Low Power Consumption etc complete as required. |
| 65 | Supplying & Laying following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in existing DWC/GI/pipe/on surface or loose for connection and testing etc as reqd. |
| 66 | 3 x 10 Sq.mm |
| 67 | SITC of Chairman unit with priority button, fixed microphone with flexible stem, Two headphone sockets and light ring, Optional chime tone facility preceding chairman announcements. Microphone on/off button.• Chairman priority button.• Rotary volume control for adjusting headphone volume.• Loudspeaker, automatically muted when microphone is on.• Microphone ‘on’ indicator (red LED).• Light ring indicator on microphone stem, lights up red whenmicrophone is on.Nominal Acoustic Input - 85dB SPLFrequency Response - 400Hz to 10kHzLength of the microphone - 488mmetc complete as required. |
| 68 | SITC of of 240W mixer amplifier with atleast 4 mic/ line inputs, 2 tone chime feature. The frequency response should be 80Hz to 18khz or better, Distortion < 1%, Separate bass and treble control. the output should be available on 100V line out screw terminals etc complete as required. |
| 69 | Supply & Laying of 15 mtr HDMI cable etc complete as required. |
| 70 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 71 | 100 A,30KA,FPMCCB |
| 72 | Providing and fixing following rating and breaking capacity and pole MCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 73 | 40A FPMCB 10KA |
| 74 | 63A FPMCB 10KA |
| 75 | Supply, installation, testing and commissioning of complete Star-Delta starter for 10 HP, 415 V, 3-phase motor in the existing cubicle panel, comprising main, Star and Delta contactors, Star-Delta timer, thermal overload relay, Single Phase Preventer, Start/Stop push buttons, indication lamps, auxiliary contacts, electrical and mechanical interlocking, control transformer where required, terminal blocks, internal power/control wiring, lugs, ferrules, cable glands, labels and all necessary accessories, including modification of the existing panel, termination, testing and commissioning, complete in all respects. |
| 76 | Supply, installation, testing and commissioning of complete Star-Delta starter for 15 HP, 415 V, 3-phase motor in the existing cubicle panel, comprising main, Star and Delta contactors, Star-Delta timer, thermal overload relay, Single Phase Preventer, Start/Stop push buttons, indication lamps, auxiliary contacts, electrical and mechanical interlocking, control transformer where required, terminal blocks, internal power/control wiring, lugs, ferrules, cable glands, labels and all necessary accessories, including modification of the existing panel, termination, testing and commissioning, complete in all respects. |
| 77 | Supply, installation, testing and commissioning of complete Star-Delta starter for 20 HP, 415 V, 3-phase motor in the existing cubicle panel, comprising main, Star and Delta contactors, Star-Delta timer, thermal overload relay, Single Phase Preventer, Start/Stop push buttons, indication lamps, auxiliary contacts, electrical and mechanical interlocking, control transformer where required, terminal blocks, internal power/control wiring, lugs, ferrules, cable glands, labels and all necessary accessories, including modification of the existing panel, termination, testing and commissioning, complete in all respects. |
| 78 | Supply, installation, testing and commissioning of complete Star-Delta starter for 30 HP, 415 V, 3-phase motor in the existing cubicle panel, comprising main, Star and Delta contactors, Star-Delta timer, thermal overload relay, Single Phase Preventer, Start/Stop push buttons, indication lamps, auxiliary contacts, electrical and mechanical interlocking, control transformer where required, terminal blocks, internal power/control wiring, lugs, ferrules, cable glands, labels and all necessary accessories, including modification of the existing panel, termination, testing and commissioning, complete in all respects. |
| 79 | Less credit for old dismantled material received from site. |
| 80 | Assorted telephone / LAN Cable |
| 81 | Assorted Wire |
| 82 | Assorted Switch/Socket/RJ45 |
| 83 | Assorted fitting |
| 84 | Assorted Ceiling Fan |
| 85 | Assorted size water cooler |
| 86 | Assorted size desert cooler |
| 87 | Assorted panel Star delta Starter Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender