Tender For Provn Of External Electric Supply For Power Mgt And Cooling System Of Zonal Center Ascon Ph-Iv At Disaster Node At 14 Cesr Under Age E/M-Ii Of Ge 865 Ews, Leh
Tender Value
27.66 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
4 days left
EMD
55400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provn Of External Electric Supply For Power Mgt And Cooling System Of Zonal Center Ascon Ph-Iv At Disaster Node At 14 Cesr Under Age E/M-Ii Of Ge 865 Ews, Leh
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 3 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 4 | Sand cushioning to under ground cables, 8 cm thick layer before laying and testing the cable and 15 cm thick after laying and directed. |
| 5 | Supply and laying factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flate size 250 x 150x50mm , complete all as specified and directed by Engr in Charge. |
| 6 | Supply and laying in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. |
| 7 | Supply and laying in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. |
| 8 | Supply and laying in replacement of XLPE insulated, armoured heavy duty with standerd copper cable rating 1100 volts grade, of size 35 sqmm cross sectional area 1 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. |
| 9 | All as per srl No.8 Aabove but of size 10 sqmm 2 core all as specified |
| 10 | All as per srl No.8 Aabove but of size 2.5 sqmm 3 core all as specified |
| 11 | Supply and fixing in replacement of tubes light grade of size 80 mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified |
| 12 | Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of tinned copper/ brass bolts nuts checknuts, and washers besides brazing ( copper strip shall be 0.5 M overlaped with copper plate by brazing) at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil earth,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to and including the earth test point of galvanised Iron/steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate , and RCC cover of size 54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in drawing Note - 1. Cost of copper strip and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items. 2. On testing,after completion of job ,if desired earth resistence is not found i.e. below 1.00 Ohms ,the earthing shall be redone on no extra cost . |
| 13 | Earth continuity conductor or main earthing lead fixed to wall on batten recess or chases or buried in ground or drawn in condutor/pipes or fixed to poles or any other indicated situation for loop earthing etc. Of size 25x3 mm aluminium strip complete all as specified and directed. |
| 14 | Test point terminal block made of gunm metal or phosphourus bronze size 75x75 mm drilled and screwed including 3 nos. 8mm dia. 25mm long hex. Head screw, complete all as specified and directed. |
| 15 | Supply and fix in replacement incl Installation , Commissioning in replacement of factory made LT panel cubical type outdoor mounted weather proof totally enclosed, CPRI approved made out of 3mm thick CRCA sheet powder coated and angle iron complete with bus of copper suitable size for capacity 600 amps 3 phase and neutral 415 volts 50 hz mounted on epoxy type insulation with PCC flooring and angle iron base frame complete all as specified and directed by Engr-in-charge including following acccessories, (a) MCCB 400 Amps Capacity 4 pole 36 KA 415 Volt -01 No (Incommer)(b) Change over switch open execution type 400 Amps 4 pole -01 No(c) MCCB 200 Amps 3 Pole 25 KA 415 V -01 No(d) MCCB 100 Amps 3 Pole 16 KA 415 V -03 Nos (e) Digital Voltmeter with selector switch (0-500 V) -02 Nos (f) Digital Amp meter with selector switch with suitable CT (0-500 A) -02 Nos (g) LED Indicating switch -02 SetNote- (i) The make of changeover and MCCBs considered as Havells, Standard, IndoAsian, HPL. (ii) The rates deemed to be inclusive of suitable size copper wiring/ copper strips from main I/C MCCB to change over switch Change over switch to main bus bar to out going MCCBs complete all as specified and directed. (iii) The design of panel make of complete accessories and drawing of LT panel should be submitted by the contractor for pre approval for the Engr-in-Charge before order and execuion of site. |
| 16 | Supply and fix voltage stablizer for automatic operation, 3 phase, naturally oil cooled, indoor type and design for input variation between 300V to 480V with output voltage stanlized at 415 V with accuracy +/- 2.5% and speed of correction 8 volt per second and capacity 150 KVA complete filled with insulating oil with suitable di - electric strength, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer