Tender For Special Repair To Bldg No P-145 (Or Cook House) Of 404 Lt Ad Regt (Comp) Under Age B/R-I Of Ge 865 Ews.
Tender Value
20.14 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
0 days left
EMD
40300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No P-145 (Or Cook House) Of 404 Lt Ad Regt (Comp) Under Age B/R-I Of Ge 865 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floor and pavings n'exc 15cm thick below or above ground level complete all as specified and as directed. |
| 2 | Dismantling floor, hearth or wall tiling including wall cement mortar, bedding (But not backing ) and rubbish of premises complete all as directed. |
| 3 | M&L for 25 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in sub base of floor complete all as directed. |
| 4 | M&L Non-Skid ceramic coloured tiles 7 to 8mm thick(squre/rectanglar) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors over 15 mm screed bed or bedding layers in cement mortar 1:4 Set and jointed in neat cement slurry and pointed in colour cement to match, complete all as specified and as directed. |
| 5 | M&L for Glazed ceramic coloured tiles in vertical surfaces 300x450x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match over 10mm thick CM (1:4) in dado/skirting tiles complete all as specified and directed. |
| 6 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and rubbish off the premises, complete all as specified and directed. |
| 7 | M&L for reinforced cement concrete (Nominal Mix) in type B-1 1:2:4 ( 20mm graded aggregate) as in slabs supported of walls , beams and columns in floors, roofs, landings, balconices , canopies , deck slabs and in shelves etc complete all as specified and as directed |
| 8 | Formwork to sides and soffits of suspended slab such as roof slab, floor slab, shelves and similar works n. exc. 200mm thick (Horizontal or sloping), finishing the concrete surfaces rough, complete all as specified and directed. |
| 9 | MS TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed. |
| 10 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc.laid bedded and pointed in any mortar, complete all as specifed and directed. |
| 11 | M&L for 20 mm thick granite stone (any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite including cutting, etc and screed bed with CM (1:4) 20mm thick laying floor tiles complete all as specified and as directed. |
| 12 | Taking down shutters of any description area exceeding 1 Sqm and not exceeding 2 Sqm each complete all as directed. |
| 13 | S&F for 35mm thick 2nd class soft wood plain framed paneled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed. |
| 14 | S&F 2nd class soft wood 35 mm thick Glazed and skelton shutter, open and prepared to receive the glass, gauze etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc. (Glass / Wiremesh should be measured seperately) as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed. |
| 15 | S&F MS framedwork such as grills, gratings etc with ends of bars shouldered and/or rivited or forged in spikes, framed guard bars, barred iron doors, ledders framed balsters walk ways railings frame work of water tanks and similar work including dismantling confirming to Fe-290, Gde-E-165 complete all as specified and as directed. |
| 16 | S&F in repair Galvanised mild steel wire cloth ,0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples. |
| 17 | M&L for preperation of new wood or wood based surface of any description over 10cm width or girth and applying two coat of synthetic enamal paint over a coat of pink primer complete all as specified and as directed. |
| 18 | Hacking out old broken glass (any thick ness, size, quality or description) from wooden panes or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads, complete all as specified and as directed . |
| 19 | M&L sheet glass 3mm thick ordinalry quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each pane complete all as specified and as directed. |
| 20 | S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed. |
| 21 | S&F 100mm long aluminium anodized, barrel tower bolt of extruded section, complete all as specified and as directed . |
| 22 | S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed. |
| 23 | S&F 100 mm size extruded aluminium alloy handles, fabricated type, anodized, complete all as specified and as directed . |
| 24 | S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed. |
| 25 | S&F 75mm long aluminium anodized, butt hinges of extruded section complete all as specified and as directed. |
| 26 | M&L Prelaminated particle board,18/19 mm thcik, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including dismantling, complete all as specified and as directed. |
| 27 | M & L for 75 mm PCC 1:3:6 type C-2 using 40mm graded aggregate as plinth protection finished even and smooth with out using extra cement, complete all as specified and as directed. |
| 28 | M&L Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade 'A' in plinth protection, complete all as specified and as directed . |
| 29 | Demolition of precast concrete block walling built in cement mortar including all quoins, arches , pillars etc all as specified and as directed. |
| 30 | M&L for pre cast solid block masonry set in CM 1:6 & casted in cement concrete type C-1 (1:3:6) using 20mm graded curshed stone aggregate complete all as specified and directed. |
| 31 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed |
| 32 | M&L for 10mm thick rendering on fair faces of block wall works finished even and smooth without using extra cement in cement mortar 1:6 complete all as specified and as directed |
| 33 | M&L for 5 mm thick rendering on ceiling finished even and smooth without using extra cement in cement mortar 1: 3 complete all as specified and as directed. |
| 34 | M & L for two coat of cement base paint on newly plastered wall surfaces including preparation of surfaces, complete all as specified and as directed. |
| 35 | M&L for preperation of new concrete /plastered surface of ceiling, any description, applying three coat of white wash complete all as specified and as directed. |
| 36 | M&L for preperation of old plastered ceiling surface of any description and applying one coat of white wash complete all as specified and as directed. |
| 37 | S & F rotational moulded HDPE water storage tanks 1000 ltrs capacity and will be PUF insulated with 75mm thick PUF insulation of density 48 kg/Cum inner and out white two layers ISI marked ( cylindical vertical type/rectangular loft type closed top) hoisted hoisted with threaded cap and fixed in position all as specified in SSR Part I including all accessories (ie GI nipple etc), including provn of 20/25 mm dia spout for connecting inlet, outlet, over flow and washout pipes and including dismantling water tanks and removing to store of 1000 ltrs capacity complete all as specified and as directed by Engr-in-Charge. |
| 38 | S & F in repairs fancy type 15mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfy handle, screwed down, screwed for iron pipe or for brass ferrule |
| 39 | Taking up or down 25 mm bore steel tubing and connections and set aside for re-use or removal to store, complete all as specified and as directed. |
| 40 | Taking up or down 32 mm bore steel tubing and connections and set aside for re-use or removal to store, complete all as specified and as directed. |
| 41 | S & F 25mm dia 3 layer PP-R polypropyene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as per manufacture instructions, complete all as specified and as directed . |
| 42 | S & F 32mm dia 3 layer PP-R polypropyene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as per manufacture instructions and complete all as specified and as directed . |
| 43 | S & F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, Waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed . |
| 44 | S & F 32mm waste coupling of PTMT for sink and wash hand basin (Half or full threaded ) (Minimum Weight 45 grams), complete all as specified and as directed . |
| 45 | S&F in repair 19mm dia mild steel, chromium plated curtain rods fancy type , with brackets, end bulbs, complete all as specified and as directed . |
| 46 | S&F in repair chromium plated soap dish any type fixed to plugs with brass screws, complete all as specified and directed. |
| 47 | S&F in repairs towel hanger with 6 Nos of pin and 600mm long Cromum plated etc complete fitted as per sepcified and directed. |
| 48 | S&F in repair 25mm outer dia PPR Ball valve (Brass insert) confirming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site completely all as specified and directed by the Engr-in-Charge. |
| 49 | S&F in repair 25mm outer dia PPR Gate valve (Brass insert) confirming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site, complete all as specified and as directed . |
| 50 | S&F in repair 32mm outer dia PPR Gate valve (Brass insert) confirming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site, complete all as specified and as directed . |
| 51 | S & F in repairs, PVC (SWR) 75 mm dia, floor trap, plain with grating including jointing to waste pipe with solvent cement complete all as specified & directed. |
| 52 | S & F in repair CP floor gratings 150mm dia, complete all as specified and as directed . |
| 53 | S&F in repair 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 54 | M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling & lining fixed with nails exc 13 sqcm and n exc 25 sqcm in section including Dismantlng .complete all as specified and as directed. |
| 55 | M&L for 2nd class soft wood clean sawn as in beeding for edges of ceiling, lining or wooden flooring work fixed with nails exc 6 sqcm and n exc 13 sqcm in section including dismantlng of old, complete all as specified and as directed. |
| 56 | M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws including dismantlng of old, complete all as specified and as directed. |
| 57 | M&L for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing white lamination fixed with screws to timber frame work as in wall panelling, shelves/boarding dismantlng of old, complete all as specified and as directed. |
| 58 | Ditto as above item no 57 but on ceiling. |
| 59 | M&L for 100 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) sub base, sub floor and pavings, complete all as specified and directed. |
| 60 | Chequered cement concrete tiles 200mm X 200mm X 25mm thick, set ,pointed & jointed in neat cement slurry in floors polished with grey cement & pigments layed over 20mm thick cement screed bed in CM 1:6 and complete including demolition of existing stone slab/ concrete tiles all as specified and directed. |
| 61 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge. |
| 62 | Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- |
| 63 | (a) One light/exhaust fan point controlled by one way switch complete all as specified and directed. |
| 64 | (c) One switch socket outlet 6 Amps, 230 volts point on Same board complete all as specified and directed. |
| 65 | (d) One switch socket outlet 6 Amps, 230 volts point on independent board complete all as specified and directed. |
| 66 | All as item No 62 above, but using cables 4 Sq mm size complete all as specified and directed. |
| 67 | Switch piano flush button single pole 6 Amps 230 volts one way, complete all as specified and directed. |
| 68 | Socket out let two-in-one 5 pin 6 Amps flush type, 230 volts, complete all as specified and directed.. |
| 69 | Switch Socket combination outlet multi purpose 5 pin 6 Amps and 16Amps 230 volts, complete all as specified and directed. |
| 70 | Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed. |
| 71 | Replacement of MCB DB, SPN, 12 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall including cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 72 | Replacement of MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall including cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 73 | MCB, SPN, AC, 240 volts \\"C\\" series capacity of 63 Amps, 10kA and making connections, complete all as specified & directed. |
| 74 | MCB, SP, AC, 240 volts \\"C\\" series capacity of 6-32 Amps, 10kA and making connections, complete all as specified & directed |
| 75 | M & L for submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x10.0 sq. mm + 1x10.0 sq. mm earth wire complete all as specified and directed. |
| 76 | Replacement 4' x 1' LED light fitting 32 Watt, 220 V, AC surface mounted box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 77 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 78 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft soil complete all as specified and directed. |
| 79 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. |
| 80 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed. |
| 81 | M & L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable, complete all as specified and directed. |
| 82 | PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other, complete all as specified and directed at site. |
| 83 | Labour only for laying of old serviceable cable covers retrieved from excavation, complete all as specified and directed. |
| 84 | Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles including taking down ol unserviceable cable and cable covers complete all as specified and/or directed. |
| 85 | S & F in repair 4 Way double door tripple Pole Neutral vertical load line Distribution Board suitable for Flush mounting and suface mounting with 250 A copper bus bar with neutral bars and earth bars with including MCCB 160 TPN as incomer and SPN/TP MCBs as out going and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 86 | Earthing complete in repair with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009.Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. |
| 87 | Deduct Schedule of Credit of Rs (-) 22347.60 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender