Tender For Repair And Maintenance Of Borewells, Water Filteration System(Ro Plant), Cleaning Of Ug Sumps At Def Lab Jodhpur
Tender Value
9.90 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
14 days left
EMD
19800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Borewells, Water Filteration System(Ro Plant), Cleaning Of Ug Sumps At Def Lab Jodhpur
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Inspection, checking of defect, repair and replacement of defective parts, sensor of existing RO Plant of capacity 20000 LPH as per to meet the required condition of water by back washing, cleaning of membrane, cleaning of cartridge filter, servicing of chemical dozer, calibration of level indicator, cleaning of chemical Tank and all control valves etc and submit the water quality report of RO Plant by collecting the sample of water (raw water and treated water) after carried out all work as mentioned above and as required at site complete all as specified and directed by Engineer-in-charge.Note :- (a) The periodicity of visit in each month but in case of some emergency or fault occurance within 48 hours to be attended by contractor or his rep, authroised RO plant specialist/manufacturer complete all as directed by Engineer-in-Charge.(b) Spare parts for replacement and chemical required for servicing of RO plant shall be measured and paid for separately under respective item of schedule. (c) The cost of replacement of small parts such as nuts, bolts, washer, screws, thimble lugs, gasket, rubber washer, wires etc and cost for testing of water quality sample shall be deemed to be included in unit rates quoted and nothing extra shall be admissible on this account. (d) All tools, plant, equipment etc required for service shall be arranged by contractor at his own without any extra cost. |
| 2 | M&L cleaning of RCC under ground sump (Raw Water ) of total capacity 400000 Ltrs incl dewatering the sump with water lifting pump, descaling internal surfaces of under ground sump with wire brush, removing the deposited mud/silt from inside the sump complete, washing with bleaching powder and flush water two times and again dewatering, applying two coats of lime wash inside the sump including writing capacity of tank, date of cleaning with synthetic enamel paint of white tint over black base (minimum size of letter 5 mm thick and 15 cm in height) complete all as specified and as directed at site by Engr-in-Charge. |
| 3 | M&L cleaning of RCC under ground sump (Treated Water) of total capacity 200000 Ltrs incl dewatering the sump with water lifting pump, descaling internal surfaces of under ground sump with wire brush, removing the deposited mud/silt from inside the sump complete, washing with bleaching powder and flush water two times and again dewatering, applying two coats of lime wash inside the sump including writing capacity of tank, date of cleaning with synthetic enamel paint of white tint over black base (minimum size of letter 5mm thick and 15 cm in height) complete all as specified and as directed at site by Engr-in-Charge. |
| 4 | Taking down carefully unserviceable any type and size dia CPVC pipe including fitting complete, removing unsv materials from site for keeping in safe custody for reuse of useable items at site and making good disturbed surfaces of walls, floors, etc. |
| 5 | Supply and fixing in replacement of unsv CPVC pipes as per IS:15778 of size dia 32 mm bore ,having thermal stability for hot & cold water pressure bearing capacity of SDR 11 pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² including all CPVC fittings, jointing off pipes, fittings with one step CPVC yellow solvent cement complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all SDR 11 CPVC fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) and pipe cutting fixing with CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 6 | Supply and fixing in replacement of unsv CPVC pipes as per IS:15778 of size dia 40 mm bore ,having thermal stability for hot & cold water pressure bearing capacity of SDR 11 pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² including all CPVC fittings, jointing off pipes, fittings with one step CPVC yellow solvent cement complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all SDR 11 CPVC fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) and pipe cutting fixing with CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 7 | Supply and fixing in replacement of unsv CPVC pipes as per IS:15778 of size dia 25 mm bore ,having thermal stability for hot & cold water pressure bearing capacity of SDR 11 pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² including all CPVC fittings, jointing off pipes, fittings with one step CPVC yellow solvent cement complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all SDR 11 CPVC fittings and pipe cutting fixing with CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 8 | Supply and fixing in replacement of unsv CPVC pipes as per IS:15778 of size dia 20 mm bore ,having thermal stability for hot & cold water pressure bearing capacity of SDR 11 pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² including all CPVC fittings, jointing off pipes, fittings with one step CPVC yellow solvent cement complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all SDR 11 CPVC fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) and pipe cutting fixing with CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 9 | Supply and fixing in replacement of unsv CPVC pipes as per IS:15778 of size dia 16 mm bore ,having thermal stability for hot & cold water pressure bearing capacity of SDR 11 pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² including all CPVC fittings, jointing off pipes, fittings with one step CPVC yellow solvent cement complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all SDR 11 CPVC fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) and pipe cutting fixing with CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 10 | Supply and fixing in replacement of unsv CPVC pipes as per IS:15778 of size dia 50 mm bore ,having thermal stability for hot & cold water pressure bearing capacity of SDR 11 pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² including all CPVC fittings, jointing off pipes, fittings with one step CPVC yellow solvent cement complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all SDR 11 CPVC fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) and pipe cutting fixing with CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 11 | Supply and fixing in replacement of unsv CPVC pipes as per ASTM F 441 in Schedule 80 of size dia 3'' (3 inch) bore ,having thermal stability for hot & cold water pressure bearing capacity of Schedule 80 pipes @23°C is 28.12 kg/cm² & at @82°C 7.03 kg/cm² including all CPVC fittings, jointing off pipes, fittings with 2 step CPVC Solvent cement comprising of 1st step CPVC Primer and 2nd step CPVC solvent cement to be used on pipes & fittings complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all CPVC fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) and pipe cutting fixing with 1st step CPVC Primer and 2nd step CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 12 | Supply and fixing in replacement of unsv CPVC pipes as per ASTM F 441 in Schedule 80 of size dia 62.5 mm bore ,having thermal stability for hot & cold water pressure bearing capacity of Schedule 80 pipes @23°C is 28.12 kg/cm² & at @82°C 7.03 kg/cm² including all CPVC fittings, jointing off pipes, fittings with 2 step CPVC Solvent cement comprising of 1st step CPVC Primer and 2nd step CPVC solvent cement to be used on pipes & fittings complete all as specified and directed by engineer-in-charge. Note : The rate quoted by contractor includes all CPVC fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) and pipe cutting fixing with 1st step CPVC Primer and 2nd step CPVC solvent cement including pipe fitting on wall, surface, floors etc as required and testing completion. |
| 13 | Taking up or down old un-serviceable sluice valves any type and size from any location complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply, installation, connection and testing sluice valve, cast iron body (long body) class PN-1.60 in replacement of unsv valve of size 3'' dia bore with flanged ends drilled ISI marked (IS : 14846:2000) having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket etc all as specified suitable for following bore of pipe. |
| 15 | Supply, installation, connection and testing sluice valve, cast iron body (long body) class PN-1.60 in replacement of unsv valve of size 2.5'' dia bore with flanged ends drilled ISI marked (IS : 14846:2000) having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket etc all as specified suitable for following bore of pipe. |
| 16 | Taking up or down old un-serviceable butter fly valves of any type and size complete from any location all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fixing in repairs cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 1.6 of bore 65 mm complete all as specified and directed by the Engr-in-Charge. |
| 18 | Supply and fixing in repairs cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 1.6 of bore 80 mm complete all as specified and directed by the Engr-in-Charge. |
| 19 | Supply and fixing in repairs cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 1.6 of bore 50 mm complete all as specified and directed by the Engr-in-Charge. |
| 20 | Supply Antiscalant |
| 21 | Supply HCl (Acid ) dosing |
| 22 | Supply SMBS dosing |
| 23 | Supply Ph booster |
| 24 | Supply Sodium Hypochloride |
| 25 | Supply Chlorine dosing |
| 26 | Supply RO Descalant |
| 27 | Supply 5 micron fine filter |
| 28 | Supply 1 micron fine filter |
| 29 | Supply common salt |
| 30 | Supply ,installation in replacement ,testing and commissioning of brackish R.O Membrane made from polyamide fibre ,thin film spiral wound based complete with interconnections of suitable size and requirement ; Dia-inches,length 40 inch array of membrane shpuldd be 4x2 for maximum recovery of system complete all as specified and directed by engineer-in-charge. |
| 31 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable in replacement of old unsv including taking down unsv PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2.5 sq. mm 3.0 core nominal cross section complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable in replacement of old unsv including taking down unsv PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4.0 sq. mm 3.0 core nominal cross section complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supplying and fixing 1100 volts grade heavy duty cable in replacement of old unsv including taking down unsv PVC insulated copper conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable circular type of size dia 4.0 sqmm 2.0 core complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable in replacement of old unsv including taking down unsv PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6.0 sq. mm 3.0 core nominal cross section complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fixing in replacement cartridge filter 20 inches 5-micron nominal complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and fixing in replacement RO CIP fine cartridge filter 20 inches complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fixing in replacement of unsv power contractor suitable for starter of 3 phase induction motor of 7.5 KW capacity raw water pump complete all as specified and directed by engineer-in-charge. |
| 38 | Supply and fixing in replacement of unsv power contractor suitable for starter of 3 high pressure submersible pump motor starter of 22.0 KW capacity complete all as specified and directed by engineer-in-charge. |
| 39 | Supply and fixing in replacement of unsv power contractor suitable for starter of 3 phase induction motor of 4.0 KW capacity treated water pump complete all as specified and directed by engineer-in-charge. |
| 40 | Supply and fixing in replacement of unsv thermal overload relay suitable for upto 7.5 KW , 415 V, 50 Hz AC starter complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and fixing in replacement of unsv thermal overload relay suitable for 22.0 KW , 415 V, 50 Hz AC starter complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and fixing, testing in replacement of old unsv electronic metering type diaphgram constatnt flow dozing pump of capacity 1 to 6 liters for acid/cheical dosing complete with accessories like tubing, connectors, non return valve with float valve and strainer on pump suction assembly with provision of flow switch transmitter for auto operation of the dozing system as per existing all as required at site complete all as specified and directed by Engineer-in-Charge. |
| 43 | Disconnecting and taking out Centrifugal/Monoblock/induction motor in horizontal/Vertical arrangement of capacity upto 20 HP of any make and model from the foundation & dismantling for overhauling and repair by replacing the ball bearing, bush, gland bush, coupling and impeller,etc re-assembling after replacement of unserviceable parts, connecting with the suction/discharge line with correct alignment and making the electric connection including testing complete and all as directed by Engineer-in-Chrage.Note: (i) ball bearing, gland bush, coupling and impeller etc will be measured and paid separately as supply only under respective items of this schedule. |
| 44 | Supply only ball bearing suitable for upto 20. HP Centrifugal/Monoblock induction motor complete all as specified and directed by Engineer-in-charge. |
| 45 | Supply only gland bush suitable for upto 20.0 HP Centrifugal/Monoblock induction motor complete all as specified and directed by Engineer-in-charge. |
| 46 | Disconnecting and taking out Centrifugal type high pressure pump of capacity 7.5 KW of any make and model from the foundation & dismantling for overhauling and repair by replacing the pump bearing, bush, gland bush, coupling and impeller,etc re-assembling after replacement of unserviceable parts, connecting with the suction/discharge line with correct alignment and making the electric connection including testing complete and all as directed by Engineer-in-Chrage. Note: (i) Pump bearing, bush, gland bush, coupling and impeller etc will be measured and paid separately as supply only under respective items of this schedule. |
| 47 | Supply only ball bearing suitable for upto 7.5 KW Centrifugal/Monoblock induction motor complete all as specified and directed by Engineer-in-charge. |
| 48 | Supply only gland bush suitable for upto 7.5 KW Centrifugal/Monoblock induction motor complete all as specified and directed by Engineer-in-Charge. |
| 49 | M&L for electrical disconnection of submersible pump for taking out existing column pipe of size 32 to 80 mm along with pump set 5 to 10 HP from borewell with essential tools like tripod, chain, pully, etc and manpower & replacement of unserviceable parts of column pipe, motor, pump etc as per requirement, spare parts and column pipe shall be measured and paid seperately, lowering of submersible pumping set with column pipe complete and testing after completion of work all as directed by Einr-in-Charge. Note: i) Repair of pump and motor will be paid and measured seperately under respective items. ii) Minor items such as rubber packing, gaskets, grease etc deemed to be included. |
| 50 | M&L for repair of submersible pump set, strip opening multi stage submersible pumpset of capacity 5 to 10 HP. Replacement of unsv parts & reassembling the same, testing after completion of job & spare parts shall be measured & paid seperately here-in-after. Complete all as directed by Engr-in-Charge. |
| 51 | (a) Thrust bearing |
| 52 | (b) Bowl set |
| 53 | (c) Impellor driving rod (shaft) complete |
| 54 | (d) Impellor |
| 55 | (e ) Bush |
| 56 | (f) MS Coupling |
| 57 | Material and labour for rewinding of submersible electric motor pump transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersible copper winding wire of appropriate gauge including all necessary insulation material as per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump, making electric connection all as directed and testing for smooth functioning for capacity of 5 HP three phase. |
| 58 | Material and labour for rewinding of submersible electric motor pump transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersible copper winding wire of appropriate gauge including all necessary insulation material as per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump, making electric connection all as directed and testing for smooth functioning for capacity of 10 HP three phase. |
| 59 | Supply and fix gun metal gate valve of size 15 mm with iron wheel head screwed both ends for iron pipe and fixed of following sizes incl taking down and removal from site:- Make: Leader, Sant, Zoloto |
| 60 | Supply and fix gun metal gate valve of size 20 mm with iron wheel head screwed both ends for iron pipe and fixed of following sizes incl taking down and removal from site:- Make: Leader, Sant, Zoloto Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender