Tender For Fixing Of Rate Contract For Repair Of Distribution Transformers Of Various Capacities At Divisional Workshop Of Electric Division, Jpdcl Udh Ur For The Year 2026-27 Or Till Next Year Tender Is Finalized.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Oct 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Fixing Of Rate Contract For Repair Of Distribution Transformers Of Various Capacities At Divisional Workshop Of Electric Division, Jpdcl Udh Ur For The Year 2026-27 Or Till Next Year Tender Is Finalized.
BOQ
| Sl. No. | Item Description |
| 1 | PART A Labour Charges for repairing of 25 KVA Distribution Transformer (Aluminium Wound) |
| 2 | Labour Charges for unloading of damaged transformers at Workshop & dragging upto stacking site. |
| 3 | Labour Charges for dragging of damaged transformers from stacing site to work site for detanking/ de-assembling to acertain the extent of damage. |
| 4 | Labour Charges for cleaning of transformer tank, radiators top covers etc. |
| 5 | Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any |
| 6 | Re-Winding of LV Coil (Aluminium). |
| 7 | Winding of LV Leg Coil (Aluminium). |
| 8 | Winding of HV Leg Coil (Aluminium). |
| 9 | Refitting/ Replacement of Bushing only HV/LV |
| 10 | Refitting/ Replacement of Bush rod only HV/LV |
| 11 | Labour charges for filtration of fresh/old transformer oil |
| 12 | Heat Treatment of Transformer HV/LV Coils |
| 13 | Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core and refitting of transformer . |
| 14 | Labour Charges for testing of transformer on 11 kV |
| 15 | Labour Charges for Loading of transformer |
| 16 | Labour Charges for weighing, stacking & loading of aluminium/copper scrap etc. |
| 17 | PART B Labour Charges for repair of 50/63 KVA Distribution Transformer (Aluminium Wound) |
| 18 | Labour Charges for unloading of damaged transformers at Workshop & dragging upto stacking site. |
| 19 | Labour Charges for dragging of damaged transformers from stacing site to work site for detanking/ de-assembling to acertain the extent of damage. |
| 20 | Labour Charges for cleaning of transformer tank, radiators top covers etc. |
| 21 | Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any |
| 22 | Re-Winding of LV Coil (Aluminium). |
| 23 | Winding of LV Leg Coil (Aluminium). |
| 24 | Winding of HV Leg Coil (Aluminium). |
| 25 | Refitting/ Replacement of Bushing only HV/LV |
| 26 | Refitting/ Replacement of Bush rod only HV/LV |
| 27 | Labour charges for filtration of fresh/old transformer oil |
| 28 | Heat Treatment of Transformer HV/LV Coils |
| 29 | Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core and refitting of transformer . |
| 30 | Labour Charges for testing of transformer on 11 kV |
| 31 | Labour Charges for Loading of transformer |
| 32 | Labour Charges for weighing, stacking & loading of aluminium/copper scrap etc. |
| 33 | PART C Labour Charges for repair of 100 KVA Distribution Transformer (Aluminium Wound) |
| 34 | Labour Charges for unloading of damaged transformers at Workshop & dragging upto stacking site. |
| 35 | Labour Charges for dragging of damaged transformers from stacing site to work site for detanking/ de-assembling to acertain the extent of damage. |
| 36 | Labour Charges for cleaning of transformer tank, radiators top covers etc. |
| 37 | Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any |
| 38 | Re-Winding of LV Coil (Aluminium). |
| 39 | Winding of LV Leg Coil (Aluminium). |
| 40 | Winding of HV Leg Coil (Aluminium). |
| 41 | Refitting/ Replacement of Bushing only HV/LV |
| 42 | Refitting/ Replacement of Bush rod only HV/LV |
| 43 | Labour charges for filtration of fresh/old transformer oil |
| 44 | Heat Treatment of Transformer HV/LV Coils |
| 45 | Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core and refitting of transformer . |
| 46 | Labour Charges for testing of transformer on 11 kV |
| 47 | Labour Charges for Loading of transformer |
| 48 | Labour Charges for weighing, stacking & loading of aluminium/copper scrap etc. |
| 49 | PART D Labour Charges for repair Of 200/250 KVA Distribution Transformer (Aluminium Wound/Copper Wound) |
| 50 | Labour Charges of unloading of damaged transformers at Workshop & dragging upto stacking site. |
| 51 | Labour Charges for dragging of damaged transformers from stacing site to work site for detanking/ de-assembling to acertain the extent of damage. |
| 52 | Labour Charges for cleaning of transformer tank, radiators top covers etc. |
| 53 | Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any |
| 54 | Re-Winding of LV Coil (Aluminium/Copper). |
| 55 | Winding of LV Leg Coil (Aluminium/copper). |
| 56 | Winding of HV Leg Coil (Aluminium/copper). |
| 57 | Refitting/ Replacement of Bushing only HV/LV |
| 58 | Refitting/ Replacement of Bush rod only HV/LV |
| 59 | Labour charges for filtration of fresh/old transformer oil |
| 60 | Heat Treatment of Transformer HV/LV Coils |
| 61 | Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core and refitting of transformer . |
| 62 | Labour Charges for testing of transformer on 11 kV |
| 63 | Labour Charges for Loading of transformer |
| 64 | Labour Charges for weighing, stacking & loading of aluminium/copper scrap etc. |
| 65 | PART E Labour Charges for repair Of 400 KVA Distribution Transformer (Copper Wound) |
| 66 | Labour Charges of unloading of damaged transformers at Workshop & dragging upto stacking site. |
| 67 | Labour Charges for dragging of damaged transformers from stacing site to work site for detanking/ de-assembling to acertain the extent of damage. |
| 68 | Labour Charges for cleaning of transformer tank, radiators top covers etc. |
| 69 | Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any |
| 70 | Re-Winding of LV Coil (Aluminium/Copper). |
| 71 | Winding of LV Leg Coil (Aluminium/copper). |
| 72 | Winding of HV Leg Coil (Aluminium/copper). |
| 73 | Refitting/ Replacement of Bushing only HV/LV |
| 74 | Refitting/ Replacement of Bush rod only HV/LV |
| 75 | Labour charges for filtration of fresh/old transformer oil |
| 76 | Heat Treatment of Transformer HV/LV Coils |
| 77 | Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core and refitting of transformer . |
| 78 | Labour Charges for testing of transformer on 11 kV |
| 79 | Labour Charges for Loading of transformer |
| 80 | Labour Charges for weighing, stacking & loading of aluminium/copper scrap etc. |
| 81 | PART F Labour Charges for repair Of 500 KVA /630 KVA Distribution Transformer (Copper Wound) |
| 82 | Labour Charges of unloading of damaged transformers at Workshop & dragging upto stacking site. |
| 83 | Labour Charges for dragging of damaged transformers from stacing site to work site for detanking/ de-assembling to acertain the extent of damage. |
| 84 | Labour Charges for cleaning of transformer tank, radiators top covers etc. |
| 85 | Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any |
| 86 | Re-Winding of LV Coil (Aluminium/Copper). |
| 87 | Winding of LV Leg Coil (Aluminium/copper). |
| 88 | Winding of HV Leg Coil (Aluminium/copper). |
| 89 | Refitting/ Replacement of Bushing only HV/LV |
| 90 | Refitting/ Replacement of Bush rod only HV/LV |
| 91 | Labour charges for filtration of fresh/old transformer oil |
| 92 | Heat Treatment of Transformer HV/LV Coils |
| 93 | Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core and refitting of transformer . |
| 94 | Labour Charges for testing of transformer on 11 kV |
| 95 | Labour Charges for Loading of transformer |
| 96 | Labour Charges for weighing, stacking & loading of aluminium/copper scrap etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender