Tender For Special Repair For Providing 30 Mm2 Insulated Acsr Conductor, Ms Pedestal, Led Street Light And Octagonal Poles To Replace Existing Life Lived / Damaged Cable And Poles On Outer Road Of Sector 20P-Iii, Dividing Road Of Sector 20P And 19P A
Tender Overview
Project Description
Tender for Special Repair For Providing 30 Mm2 Insulated Acsr Conductor, Ms Pedestal, Led Street Light And Octagonal Poles To Replace Existing Life Lived / Damaged Cable And Poles On Outer Road Of Sector 20P-Iii, Dividing Road Of Sector 20P And 19P And Outer Road Of Sector 19P At Sirsa (Edc) .(Including 5 Years Defect Liability Period Of Led Lights, 1 Years Defect Liability Period For Mtc.And On/Off Operation Of Led Street Lights And All Other Items Free Of Cost ). Rates Taken In Dnit Are Excluding Gst.A/Cost Rs. 11.05 Lacs E/Money Rs.22100/- Time Limit : 3 Months
BOQ
| Sl. No. | Item Description |
| 1 | 24.4.8.7STREET LIGHT 8.7. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 9 Metre Long pole with top dia 100 mm and bottom 200 mm with base plate of size 350 x 350 x 20 mm. [Through Rate] |
| 2 | 24.5.2.3MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 3 | 23.22.1.3MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate] |
| 4 | 23.22.5.1MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 5 | 23.27.3Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 6 | 24.13.26LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 26. 25 Sq mm 2core (Arm.) [Through Rate] |
| 7 | 23.28.14.17Supplying, installation, Testing and Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80 , under voltage and over voltage protection,EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 17. 150 watt [Rate] |
| 8 | Job WorkSupply and Erection of Galavanized steel item Nut and Bolts etc. including cutting, bending to the required shape, drilling hole, carriage, loading-unloading complete in all respect upto the entire satisfaction of Engineer-in-charge.(Excluding GST) |
| 9 | Job WorkSupply and Erection of Galavanized steel item (Flat, Angle, Channel) etc. including cutting, bending to the required shape, drilling hole, carriage, loading-unloading complete in all respect upto the entire satisfaction of Engineer-in-charge.(Excluding GST) |
| 10 | Job WorkSupply and Erection of shackle insulator as per DHBVN specification complete in all respect (Excluding GST). |
| 11 | Job WorkSupply, erection, testing and commissioning of ELEX-TWS-2EXT / Amson’s make Automatic electric timer to switch ON/OFF the street light / road light automatically. It should have lux level adjustable switch, with extensible mountable sensor. It will change ON/OFF timing automatically as per lux level of season throughout the year as purchase in the timing of sun-rising and sun setting suitable for street / road light. It will have three Nos. LandT make, 3 pole power contactor model MNX-25 to control 25 amp. Per phase with 220 Volt coils. It will have auto/manual switching mode for repair of street light during day time and the whole unit fixed on Bakelite sheet to assemble the components etc. The erection of the complete unit in the existing pedestal with complete wiring upto the satisfaction of the Engineer-in-charge (Excluding GST). |
| 12 | Job WorkSupply and erection of of PVC flexible aluminium wire of size 2.50 Sqmm single core complete in all respect as per standard specification upto the entire satisfaction of Engineer-in-Charge (Excluding GST) |
| 13 | Job WorkSupply and erection of hot dip galvanized single arm bracket with arm of 50 mm dia (Nominal) MS pipe 1500 mm long (3.25 mm thick) duly welded with 450 mm long 3 mm thick octagonal canopy of suitable dia (3mm thick) with angle of inclination 105 degree to the vertical. The top end of the canopy should be closed with MS sheet of 16 SWG. The bracket and canopy be supported with bracing of 1400 mm long, 25 mm dia hot dip MS pipe (2mm thick). The rate are inclusive of cutting, welding and all labour charges. The bracket shall be as per design and drawing enclosed complete all respect upto entire satisfication of Engineer-in-charge of the work. (Excluding GST). |
| 14 | Job WorkSupply and Erection of ACSR conductor 30mm2 PVC insulated conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per DHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports including disconnection and reconnection of LED Street Light fittings complete in all respect upto the entire satisfaction of Engineer-in-Charge (Excluding GST). |
| 15 | Job WorkSupply and Erection of Junction Box Door Cover Plate for Hot Dip Galvanized Octagonal Pole of suitable size with 2 Nos. SS Allen Key Bolts complete in all respect upto entire satisfaction of Engineer-In-Charge (Excluding GST). |
| 16 | Job WorkCredit of Iron Scrap of old M.S. Pedestal including lifting of scrap material from the site of work up to the entire of Engineer-In-Charge of work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender