Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57564340

Tender For Repair And Maintenance Of The Various Types Of Pipeline Including Replacement Of The Old Worn Out Pipes, Valves Fitting Etc Along With The Misc Items Of Zone C And D Under Ge (W) Pathankot

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
30 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
8 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of The Various Types Of Pipeline Including Replacement Of The Old Worn Out Pipes, Valves Fitting Etc Along With The Misc Items Of Zone C And D Under Ge (W) Pathankot

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Oct-2026 Corrigendum 01 Date 12-Oct-2026

BOQ

Name of Work:- Repair and Maint of the various types of pipeline including replacement of the old worn out pipes, valves fitting etc along with the Misc items of Zone C and D under GE (W) Pathankot
Sl. No. Item Description
1M&L for repair and maintenance of existing Ionisation plant consists of 2 Copper silver Ionisation electrodes along with micrprocessor controller and feed pump complete for swimming pool with replacement of old existing copper silver electrodes, complete trouble shooting of the control unit with necessay repair or complete replacement as per requirement along with flow sensor replacement with flow meter along with all necessary control copper wiring as well as supply wiring including all other connected parts and items to make it complete functional as per standard for the water of swimming pool .The complete job includes any left out parts to make it functional with proper calibration along with testing of treated water for traget ion levels i.e 0.2-0.8 mg/l for copper and 0.02-0.1 mg/l for silver to ensure WHO safety limits for swiimimg pool complete in all respect as directed by Engr in charge.
2Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth in any type of soil for repairing/ replacement of CI & GI pipes including getting out excavated earth complete all as specified and directed.
3Returning, filling in trenches incl spreading and leveling, watering and well ramming in layers n.exc. 25 cm thick all as specified.
4Removal of excavated soil to a distance n.exc. 50 mtr and depositing the same where directed at a level n.exc. 1.5 mtr above starting point complete all as specified
5Taking out cast iron/DI/MS water mains 150 mm dia bore carefully (including all fittings) with spigot and socket ends and lead joints, including burning out joints complete all as specified and directed by Engr- in - Charge. Note- Excavation and earth work shall be measured and paid saperately under relative items.
6All as per serial item No 5 here-in before but 100 mm dia bore
7All as per serial item No 5 here-in before but 80 mm dia bore
8Relaying old CI pipe after cleaning complete of size 150 mm dia ( old serviciable CI pipe as retrieved from takingdown)
9All as per serial item No 6 here-in before but of size 100 mm dia
10All as per serial item No 6 here-in before but of size 80 mm dia
11M&L for Rubber gasket/Tyten joint for 150 mm dia pipe complete all as specified and directed by Engr-in-charge. (Earth work if required should be included in the same rate)
12All as per serial item No 9 here-in before but for 100 mm dia pipe.
13All as per serial item No 9 here-in before bit for 80 mm dia pipe.
14M&L for Run lead joint for CI pipe 150 mm dia complete all as specified and directed by Engr-in-charge.
15All as per serial item No 12 here-in before but for CI pipe 100 mm dia.
16All as per serial item No 12 here-in before but for CI pipe 80 mm dia.NOTE FOR ITEM NO 9, 10, 11,12 , 13 & 14 : Joint filling will be done by contractor immediately as and when intimate him (Day & Night). If same should be not done by contractor recovery will be made from him @200 perday per complain. Rates should be inclusive of earth work i.e. excavation, re-filling & removal.
17Taking out unsv old GI tubing including connections carefully, for removal to store all as directed and specified by Engr - in - Charge of size. 15 mm dia bore
18All as per serial item No 15 here-in before but 20 mm dia bore
19All as per serial item No 15 here-in before but 25 mm dia bore
20All as per serial item No 15 here-in before but 40 mm dia bore
21All as per serial item No 15 here-in before but 50 mm dia bore
22All as per serial item No 15 here-in before but 80 mm dia bore
23All as per serial item No 15 here-in before but 100 mm dia bore
24S&F GI Pipein lieu of old unsv GI tubing of medium grade with all fitttings laid in trenches of size 15 mm dia. complete all as specified and directed
25All as per serial item No 16 here-in before but of size 20 mm dia.
26All as per serial item No 16 here-in before but of size 25 mm dia.
27All as per serial item No 16 here-in before but of size 40 mm dia.
28All as per serial item No 16 here-in before but of size 50 mm dia.
29All as per serial item No 16 here-in before but of size 80 mm dia.
30All as per serial item No 16 here-in-before but of size 100 mm dia. Note- Excavation and earth work shall measured and paid saperately under respective items
31S&F in repair Cast iron bend (any type radius and angle) taper any type for (straight) bend increasing decreasing of double socket/flanged etc. Tee piece single branch, Y junction, double branch, collar and plug of upto 150mm bore CI pipe confirming to IS-1526 : 1976 complete all as specified and as directed.
32S&F in replacement gun metal, globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed 50 mm dia all as specified.
33All as per serial item No 18 here-in-before but of 40mm dia
34All as per serial item No 18 here-in-before but of 25 mm dia
35All as per serial item No 18 here-in-before but of 20 mm dia
36All as per serial item No 18 here-in-before but of 15 mm dia
37S&F in replacement of cast iron sluice valve 150 mm dia both side flanged PN-1.6 confirming to IS 14846 (ISI marked) with stainless steel spindle and iron wheel non raising type including, nuts and bolts.
38All as per serial item No 19 here-in-before but of size 100mm dia.
39All as per serial item No 19 here-in-before but of size 80mm dia.
40All as per serial item No 19 here-in-before but of size 200mm dia.
41S&F in replacement of cast iron non return valve 150 mm dia both side flanged PN-1.6 including, nuts and bolts complete all as specified and directed
42Surface dressing n exc 15 cm deep including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, leveling & water spreading and removing rubbish, upto a distance of 50 meters outside the periphery of the area under clearance all as directed by Engr – in – charge .
43S&F in replacement of totally burned pressure boosting pump complete with 1 HP, single phase 220 volts capacity motor suitable for upto 2 bathrooms (both for hot /cold water) alongwith suitable capacity size diaphragam pressure tank complete with safety arrangements, all as specified and directed by Engr-in-charge.
44M&L for repairing of pipe line of size 150 mm dia, in position fixed at overhead tank (appx 50 feet to 60 feet height) by using of all suitable scaffolding, trestles, ladders, cradles, chain pulley for holdiing the pipe etc incl necessary repair work such as welding,cutting ,replacing of piece of pipe etc as per site requirement complete all as specified and directed by Engr-in-charge.NOTE : (i) All T&P required shall be supplied by the contarctor without extra cost to the department (ii) In case of replacement of CI pipe , it should be measured and paid seperately under relevant item of Sch (iii) Required necessary safety measures during the work will be taken by contractor. if any case of mishappening due to negligency, contractor is wholy responsible for the same.
45S&F in replacement of burnt/UNSV ON load change over switch without enclosure front operated, 3 phase 415 volt 50 HZ 4 poleof capacity 63 Amps, complete all as specified and completed.
46S&F in replacement of burnt/UNSV ON load change over switch without enclosure front operated, 3 phase 415 volt 50 HZ 4 poleof capacity 160 Amps, complete all as specified and completed.
47S&F in replacement of burnt/UNSV ON load change over switch without enclosure front operated, 3 phase 415 volt 50 HZ 4 poleof capacity 250 Amps, complete all as specified and completed.
48M&L for Construction of brick masonry valve pit of size 1200x1200x900 mm (internal dimensions) withs well burnt 'B' class bricks of one brick thick built in cement mortar 1.4 with 15 mm thick cement plaster in 1:4 on internal side and pointing flush over 15 mm thick PCC 1:4:8 in foundation complete with cover makde of angle iron frame of size 40 x 40 x 4mm with MS sheet of 10 SWG with locking arrangement set in PCC 1:2:4 in CM 1:4 as directed and duly painted with two coats of synthetic enamel black paint over as coat of red oxide primer incl prepration of surfaces and also incl excavation, earth work, returning, filling and removal of surplus material to a distance n.exc. 50 m all as specified and directed
49M&L for applying synthetic enamel paint with one coat of spray painting of approved color to header including connected acessories such as sluice valve ( 80mm to to 200 mm size) flanges bends etc including marking inlet and outlet as per instruction by Engr-in-Charge complete including preparation of old painted surface all as directed .
50M&L for applying synthetic enamel paint with one coat of spray painting of approved color to 150mm dia vertical CI/DI/MS pipe (incoming, outgoings, and overflow/washout) each appx of 20 mtr length connected to OHT Reservior including ladder and railing of OHT, and connected acessories such as sluice valves (80mm to 200 mm), flanges, bends etc with marking inlet/outlet all as specified and directed by Engr-in-Charge.
51Repair, servicing and comprehensive maintenance of DG Sets of any make of the following capacities incl replacement of defective /burn out parts by new parts such as filters,gaskets,V belts,Engine oil , rubber hoses,cleaning of alternator by vacuum cleaner and greasing of bearing with other connected work for the cap 200 KVA complete all as specified and directed by Engr-in-charge.(NOTE: Supply only of Spare parts required for repair/maint will be measured & paid separately under relavent items.).The spare parts will be as per OEM and should be of make of OEM genset. It should be from Authorised dealers of the Make of Genset.
52All as per Srl Item No 30 here-in before but of cap 50/63/62.5 kVA of any Make & type
53All as per Srl Item No 30 here-in before but of cap 20-40 kVA of any Make & Type
54Diesel filter element with O rings suitale for cap 200 KVA all as specified and directed by Engr-in-charge.
55All as per item Sr No 33 here-in before but for cap 50/62.5/63 kVA.
56All as per item Sr No 33 here-in before but for cap 20-40 kVA.
57Engine oil filter with by pass filter element with O rings suitale for cap 200 kVA all as specified and directed by Engr-in-charge.
58All as per item Sr No 36 here-in before but for cap 50/62.5/63 kVA .
59All as per item Sr No 36 here-in before but for cap 20-40 kVA .
60Air filter element suitale for cap 200 kVA all as specified and directed by Engr-in-charge.
61All as per item Sr No 39 here-in before but for cap 50/62.5/63 kVA.
62All as per item Sr No 39 here-in before but for cap 20-40 kVA.
63Fan belt suitable for cap 200 kVA all as specified and directed by Engr-in-charge.
64All as per item Sr No 42 here-in before but for cap 50/62.5/63 kVA.
65All as per item Sr No 42 here-in before but for cap 20-40 kVA.
66Rubber hose pipe set with clamp suitale for cap 200 kVA all as specified and directed by Engr-in-charge.
67All as per item Sr No 45 here-in before but for cap 50/62.5/63 kVA.
68All as per item Sr No 45 here-in before but for cap 20-40 kVA.
69Supply & pouring in sump/topping up of Engine oil of grade 15W-40/20W-50 in engine or replacement of Engine
70M&L in replacement coolant for radiator of any make any type DG set at various loactions all as directed by Engr-in-charge
71S&F in replacement battery lead of copper conductor 16 sqmm single core 1.5 mtr long fitted with battery lead terminal one side and other side with brass ternminal,clapms, copper lugs and connection as directected by Engr-in- Charge.
72Supply & pouring of Electrolyte for lead acid battries in sealed container all as directed by Engr-in-charge
73Disconnecting of radiator from engine of DG sets of capacity 200 kVA , taking it to workshop for overall cleaning, descaling with restore plus solution ,welding and brazing as required for repair of water leaking, refixing it at site duly repaired all as directed by Engineer -in-Charge.The job includes the transportation to and fro charges .
74All as per Item 52 here-in before but of Cap 50/ 62.5/63 kVA complete.
75All as per Item 52 here-in before but of Cap 20-40 kVA complete.
76M&L for Cleaning of fuel tank both internal & external by removing all the dust/sadiments etc incl replacement of fuel cap and replacement of fuel pipe (tank to DG set) complete for Cap 200 kVA of any make & type all as specified and directed by Engr-in-charge.
77All as per Item no 55here-in before but of cap 20-63 kVA
78S&F in replacement of water pump assy of DG set cap 200 kVA of OEM of genset make & type all as directed by Engr-in-charge
79All as per Item 57 here-in before but of Cap 50/62.5/63 kVA.
80All as per Item 57 here-in before but of Cap 20-40 kVA .
81Taking out FIP from DG set of cap 200 kVA of any make & type,transportation to authorised service centre for overhauling and re-calibration and re-fixing to DG set including replacement of necessary spare parts such as delivery valves, plunger 'O' ring spring, fuel injector pipe set, etc. complete all as specified and as directed by Engr-in-charge.
82All as per Item 60 here-in before but of Cap 50/62.5/63 kVA.
83All as per Item 60 here-in before but of Cap 20-40 kVA .
84S&F in Replacement of old unsv Self Starter 12 V of any type of DG Set complete in all respect as a single assyly complete of make of existing self starter/OEM of of Genset all as specified and directed by Eng-in-Charge
85S&F in Replacement of old unsv Self Starter 24 V of any type of DG Set complete in all respect as a single assyly complete of make of existing self starter/OEM of of Genset all as specified and directed by Eng-in-Charge
86Taking out unserviciable door lock incl all hinges of DG set canopy and S&F new lock with keys and all hinges as per sample andall as per directed by Engr-in-charge.
87S&F in replacement of MS coupling with new coulping rubber bush /rubber disc by taking coupling from engine and generator/alternator joint of 200 kVA Cap DG set of any make & type complete all as specifies and as directed.
88All as per item no 66 here-in before but of cap 50/62.5/63 kVA
89All as per item no 66 here-in before but of cap 20-40 kVA
90S&F in repair anti vibration pads suitable for 40/50/63/62.5 kVA DG set complete all as specified and as directed by Engr-in-Charge.
91S&F in replacement of battery Charger 12 Volts suiatble to charge battery upto 180 AH, copper wound, heavy duty complete all as directed by Engineer -in-Charge.
92All as per item no 70 here-in before but of cap 24V.
93S&F in replacement AVR (Automatic Voltage Regulator) of DG set of capacity 200 kVA of any make & type all as directed by Engineer-in-Charge.
94All as per Item No 72 here-in before but of cap 50/63/62.5 kVA
95All as per Item No 72 here-in before but of cap 20-40 kVA
96S&F in replacement of old unsv Turbo charging unit for 50/63/62.5 kVA DG Set complete all as specified and directed by Engr-in-Charge. Make:Kirloskar,Cummins,Greaves /OEM of existing genset
97Disconnecting incoming / outgoing cable connection from alternator of 62.5/63/50 kVA DG set and taking out from DG set room checking carefully and transporting to auth workshop for repair and rewinding of alternator dismantling into parts and cutting the burnt/damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete include water load test all as specified and directed by Engr-in-charge.(NOTE: All neccessary T&P for dismantling,transporting and installation cost is deemed in this item and nothing extra shall be admissible).
98All as per Item No 76 here-in before but of cap 20-40 kVA
99S&F in repairs Battery lead acid 12 volt DC, 120 AH to be fitted on DG set including connecting S/C copper lead of size 10 Sqmm dia with two nos of bty terminal complete all as specified and directed.
100S&F in replacement of old unsv Electronic controller unit (ECU) complete assembly including all relays, PCBs & mimic visual display complete with ON/OFF switches and phase indicators complete suitable for 200 kVA DG set of Genset OEM make & type all as per specified and as directed.
101All as per Item No 79 here-in before but of cap 50/63/62.5 kVA
102All as per Item No 79 here-in before but of cap 20-40 kVA
103S&F in replacement of on load change over switch 415 Volt 50 HZ capacity 160 Amps , open execution with incoming and outgoing connections including all connected works deemed inclusive in the qoated rates.
104S&F in replacement of on load change over switch 415 Volt 50 HZ capacity 100 Amps , open execution with incoming and outgoing connections including all connected works deemed inclusive in the qoated rates.
105S&F in replacement of Aluminimum tube (Thimbles) terminal heavy duty of size 95 Sq.mm.
106S&F in replacement of Aluminimum tube (Thimbles) terminal heavy duty of size 70 Sq.mm.
107S&F in replacement of Aluminimum tube (Thimbles) terminal heavy duty of size 150 Sqmm.
108S&F in replacement of Aluminimum tube (Thimbles) terminal heavy duty of size 120 Sq.mm
109S&F in supply and replacement of indicator lamp (LED type) fitting with neon lamp in three colour (Red/Green/Yellow).
110M&L for Overhauling of DG set of any make & type of capacity 63 KVA by dismantelling the parts of DG set replacing the worn out parts, cleaning/servicing thoroughly and testing on load after completion of work including all spare parts as required at site for smooth functioning of DG set complete all as specified and as directed by Engr-in-Charge. Overhauling of genset (generator set) includes a comprehensive inspection, cleaning, and replacement of components within its main parts: the engine (prime mover) and the alternator. The specific parts includes Pistons and piston rings,Cylinder liners/wall ,Cylinder heads, Valves, valve guides, and valve seats ,Connecting rods,Bearings, Main bearings and rod bearings & Auxiliary Components etc including gaskets and seals, O-rings complete in all respect to make genset functional in all respect with after complete testing as per standards with proper load and calibration etc
111S&F in replacement electronic governor suitable for DG set of capacity 20- 63 KVA complete with electric actuator , electronic speed control unit and magnetic sensor all as specified and directed by Engr-in-Charge.
112S&F in replacement of Exhaust system/ silencer For DG sets of capacity 50/62.5/63 KVA as required at site for smooth functioning of DG set complete all as specified and as directed by Engr-in-Charge.
113S&F in replacement of ACP sheet sign board of size 10'x2'x 1/2' showing installation name/location duly fixed on suitable MS square frame fixed on MS pipe duly painted and grouted with PCC including 4 Nos of LED tube lights 18 watt 4' long properly wired and connecting to nearby point with 3 core aluminium condutor cable PVC sheathed 15 mtr long complete all as directed by Engr-in-charge.
114Supply, installation, testing and commissioning of LT Feeder Pillar indoor type confirming of IS 5039, CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 2.00mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 42 with pre-treatment through 7 tank hot chemical process prior to powder coated powder coated with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface.
115(i) Rectangular copper bus bar fixed on insulated mounting arrangement of rating 1.5 times current carrying capacity of incoming switch gear or not less than 400 Amp whichever higher provided with heat shrinkable sleeve not less than one mm thick. -04 Nos (ii) 3 lines LCD display 3P, 4W, VAF + PF meter in 96 x 96 sqmm flush mounted case, accuracy class 1.0 - 01 No(iii) Suitable CTs of cast resin type with necesaary CT shortlinking should be provieded . - 1 set.(iv)Necessary electric wiring for running the plant including inter connection and inter locking wiring as per specification by PVC insulated multi core stranded copper control cable of suitable capacity - 01 Job. Incoming : (a) MCCB 4P 36 KA 320 Amps Icu =36 KA at 415 volts with microprocessor release type - 01 No (I/C) . Ics = 100 % Icu, adjustable overload setting from 0.4 to 1.0 x In ,adjustable short-circuit setting from 1.5 to 8 x Ir and class II front face, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc . Make of MCCB: Legrand/ ABB/Schenider/ Lauritz& knudsen/Siemens -01 NO
116(b) Changeover Switch 4 pole 415 volts of 63 Amps-02 No (For Incomer of 2 Nos of DG sets) OutGoing: (a) MCCB 4P 16 KA 100 Amps Icu =16 kA at 415 volts Thermal - Magnetic Release - 01 No . Ics = 100 % Icu,with adjustable over load setting and adjustable short circuit setting and class II front face, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc . Make of ACB/ MCCB: Legrand/ ABB/Schenider/ Lauritz& knudsen/Siemens. -0 2 No b. MCCB 4P 16 KA 63 Amps Icu =16 kA at 415 volts Thermal - Magnetic Release - 03 No (02 Working +01 Stand by . Ics = 100 % Icu,with adjustable over load setting and adjustable short circuit setting and class II front face, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc .(03 working +01 Spare) Nos - 04 Nos Make of MCCB: Legrand/ ABB/Schenider/ Lauritz& knudsen/Siemens (c) Indicating lamp (LED type) RYB - 01 Set of threed. All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of standard MS sheet factory made duly powder coated front and rar door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
117Supply and replacement of old unsv PORTABLE CHLORINE METER suiatble for on site testing in easy and simple method.It should be specially designed Chlorine portable meter which enables to analyse free / Total Chlorine on site with higher accuracy. The meter should be supplied in a weatherproof hard plastic case that should be ultra light with all the accessories which are required to carry out test on site.They should be provided with provided with large LCD display and advance memory storage functionalities. with follwing features: Make AQUA SOL Digita / RAKIRO/LABTRONFeatures :> Microprocessor based fast, reliable and accurate measurements.> Spectrophotometric Method for Detailed Analysis.> Reagents & Standards Based on International Methods.> Low Cost Chlorine Reagents.> Weatherproof Hard Case and Compact Design.> Large LCD display for reading convenience.> Memory and Storage function
118Supply only high strength Calcium based granular chlorination chemical of fwg specifications for water treatment in sealed packing of 45 Kgs HDPE Jars to be supplied at MES store yard. AGE E/M Office as directed by Engr-in-Charge.(a) Chemical analysis & physical obsn : (i) Description: Whitish granules (ii) Granular size (Mesh passing through- 100 BSS): 1.1 (+/-0.1%) (iii) Water/Moisture: 5.00 (+/- 0.2)% (iv) Other insoluble Calcium salts: 1.1 (+/- 0.1)% (v) Mercury & other Heavy Metal contaminants: BDL (vi) The chlorination chemical must contain appropriate quantities of dispersants/ corrosion inhibitors to prevent encrustation/ scaling in distribution systems.(b) Strength in terms of quantity of chlorination chemical required to obtain free chlorine of 1 ppm per lakh liters of water requirement must be 140-160 gm per one lakh liter of water to achieve 1 ppm Av. Cl. at injection point (contains not less than 60 to 70% active chlorine).(c) Stability: Projected shelf life of chlorination chemical must be one year with minimal loss of chlorine.(d) Handing of chlorination chemical for regular chlorination: (i) Operational considerations: Must be safe to use in terms of level of insoluble components. There must be no risks relating to encrustations in equipment and pipelines, no sludge generation, no hard water scalling in supply water.
119M&L for scraping old paint from LT panels/ feeder pillars inner & outside off size with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey/ blue from top of PCC coping and marking number/ name of panel and feeders in alphabets not less than 50mm in size complete all as specified & directed by Engineer-in-charge.
120M&L for replacing 4 pole contactors (heavy duty) with built in auxiliary contacts ac 415 volts ratings 16 Amps.
121M&L for replacing 4 pole contactors (heavy duty) with built in auxiliary contacts ac 415 volts ratings 32 Amps.
122M&L for replacing 4 pole contactors (heavy duty) with built in auxiliary contacts ac 415 volts ratings 40 Amps.
123M&L for brick work sub class B old sze bricks stright or cured in plan. exe. 6.0M mean radius built in cement mortor 1:6 all as specified
124M&L 15 mm thick cement plaster in cement mortar 1:4 on brick or concret surface finished even and smooth surface without using extra cement
125M&L for pepration new plastered and unplastered wall surface and applied 2 coat of cement base paint over one priming coat complete all as specified.
126M&L for PCC (1:2:4) type B-O using 12.5 mm graded stone aggregate as in lintel upto 1.5 m clear span ,cills,steps,seismic or other similar brand ,plinth course coping etc incl weathering slightly rounded or chamfered angles and througting all as specified
127M&L PVC coated chain link fencing 10 guage thick galvanised steel wire and 50mmx50mm size mesh fixed to steel fencing post by galvanized iron nut bolt etc incl provn of binding wire complete all as specified by engr-in- Charge and chain link approved by GE
128S&F mild steel work as in posts and struts in fencing including cutting, tops to shape as directed, drilling holes, notching for wirefencing / chain link fencing etc. flat iron fillets (for securing chain link fencing etc.) including all necessary drilling, bolting orreveting ,welding, etc. and similar embeding in concret and securing etcand work conforming to Fe-290 Gde E-165 including painting two coat of synthetic enamel paint over a coat of primer all as directed
129S&F structural framed work as in doors or gates of angle or other section with gusset plates, rails,bracesetc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with end incl either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing confirming to Fe 410-W (Gde-E-250) quality A, complete including two coats of synethic enamel paint over a coat red oxide primer all as directed
130M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as directed .
131M&L for 100 mm thick cement conrete(1:2:4) type B-1 using 20 mm graded stone aggregate set in cement mortar 1:4 as in floor incl necessary form work and fair finish to exposed surfaces without using extra cement complete
132M&L for aggregate for loose filling of guage 40 mm to 80 mm graded all as directed
133S&F in replacement informatory board of size 1.20 x 0.90 m made of aluminium sheet 2mm thick with frame of stainless steel rectangular pipe 25 x 15 mm and outer boarder of stainless steel pipe 35mm dia and each side with marking of colour and pasted with heating process. The letters shall be 75 mm to 100 mm high of white colour cut to shape with special plotter and in proper manner. The board shall be fixed with 02 Nos stainless steel pipes of dia 75 mm of 304 grade glossy finish, with MS plate 3 mm thick welded at bottom of pipes and board shall be fixed at height of 3.00 m (Tope level of board) above GL and embedded and grouted in ground in cement concrete 1:2:4 type B-1 including necessary excavation and earth work complete all as specified and directed.
134M&L for duct cover made of 6mm thick chequered MS plate of suitable size including handle made of MS bar of size 6mm dia atleast 150 mm long including painting with synthetic enamel paint 2 coats in balck colour over one coat of red oxide primer all as specified and directed by Engineer-in-Charge.
135Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 107555.80 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57564340
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of The Various Types Of Pipeline Including Replacement Of The Old Worn Out Pipes, Valves Fitting Etc Along With The Misc Items Of Zone C And D Under Ge (W) Pathankot
Basic Detail
Tender No GE/PKT-56/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 01 Oct 2026
Submission Date 12 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
636b6f48-f628-4ed1-81c1-db35962c9270.html
BOQ_885424.xls
Tender56.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

636b6f48-f628-4ed1-81c1-db35962c9270.html

xls

BOQ_885424.xls

pdf

Tender56.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders