Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57564339

Tender For Addn/Altn To Toilet Of Bldg No P-31 At Hq Ce Pathankot Zone, Provn Of 02 X Toilet With Allied Facilities At Central Sainik Gurudwara, Provn Of 11 X Alm Window With Net And 04 X Alm Door With Glass In Bldg No P-4 Of 131 Sho And special Repa

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
34.03 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
20 days left
EMD
68060
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Addn/Altn To Toilet Of Bldg No P-31 At Hq Ce Pathankot Zone, Provn Of 02 X Toilet With Allied Facilities At Central Sainik Gurudwara, Provn Of 11 X Alm Window With Net And 04 X Alm Door With Glass In Bldg No P-4 Of 131 Sho And special Repair To Bldg No Np-04, P-11 And Np-15 At Cwe Office In Aor Of Age B/R-1 Under Ge (West) Pathankot

BOQ

Name of Work:- ADDN/ALTN TO TOILET OF BLDG NO P-31 AT HQ CE PATHANKOT ZONE, PROVN OF 02 X TOILET WITH ALLIED FACILITIES AT CENTRAL SAINIK GURUDWARA, PROVN OF 11 X ALM WINDOW WITH NET AND 04 X ALM DOOR WITH GLASS IN BLDG NO P-4 OF 131 SHO AND SPL REPAIR TO BLDG NO NP-04, P-11 AND NP-15 AT CWE OFFICE IN AOR OF AGE B/R-1 UNDER GE (WEST) PATHANKOT
Sl. No. Item Description
1Demolition of RCC work, Roofs, floors , beams staircases, landing, chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition)
2M&L reinfornced cement concrete with nominal mix 1 : 1.5 : 3 (using 12.50 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as pecified and directed
3M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
4S&F TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
5Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
6M & L rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and directed.
7M&L for applying 1.5 mm one coat of white cement based wall care putty on wall , new or old surfaces of any description finished even and smooth complete all as specified and directed.
8M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over one coat of primer for smooth finish.etc complete all as specified and directed .
9M & L for preparation of old plastered surfaces of walls and applying two coats of oil bound distemper with roller primer smooth finish.etc complete all as specified and directed .
10M&L rendering 5 mm thick on fair faces of concrete surface of ceiling in CM 1 : 3 and finishing even and smooth without using extra cement complete all as specified and directed..
11M & L for preparation of newly plastered surfaces of ceiling and applying minimum 1.5 mm thick white cement based wall care putty and applying two coats of oil bound distemper with Including one coat or primer complete all as specified and directed.
12M & L for preparation of old plastered surfaces of ceiling and applying minimum 1.5 mm thick white cement based wall care putty and applying two coats oftwo coats of oil bound distemper with Including one coat or primer complete all as specified and directed.
13Demolition of brick work built in CM incl. taking out roots vegetation if any at any position and removal to out side MD land
14M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in CM(1:6) complete all as specified
15M&L for Brick work with sub class 'B' bricks, straight or curved on plan any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
16Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc complete all as specified and directed.
17M&L Non-Skid ceramic coloured tiles 7 to 8 mm thick (square/reactangular) area of each tile exc 0.42 Sqm but not exc 1.00 Sqm, in floor fixing with spacer and filing epxy grouting to match over incl 15 mm thick screed bed in cement mortar 1:4 including finishing even and fair complete all as specified.
18All as per srl item No 17.00 above but in vertical surfacearea of wal complete all as specified and directed.
19Taking up or down steel tubing with connections for cleaning for refixing or removing to store yard complete of bore15mm complete all as specified.
20S&F Steel water tubing medium grade galvanised with all fittings including short length , fixed to walls and ceiling and laid in floor complete with all fittings (such as bends, elbows, Tee , short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc) of nominal bore dia 15mm complete all as specified.
21Taking up or down steel tubing with connections for cleaning for refixing or removing to store yard complete of bore20 mm complete all as specified.
22S&F Steel water tubing medium grade galvanised with all fittings including short length , fixed to walls and ceiling and laid in floor complete with all fittings (such as bends, elbows, Tee , short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc) of nominal bore dia 20mm complete all as specified.
23Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
24S&F rotational moulded polythylence water storage tanks 1000 Ltr cylindrical vertaical with closed top) hoisted and fixed in position all as specified in SSR Pt-I of 1000 ltrs including disconnecting the unserviceable existing tanks complete screwed for iron pipe or brass ferrule directed
25S&F Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete 25mm dia complete all as specified and directed.
26M&L Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 25mm bore dia complete all as specified and directed
27S & F 6 mm Mirror bevelled edge mirror of selected quality glass, mounted exc 0.42 Sqm but not exc 1.00 Sqm and fixed to wooden plughs with chromium plated brass screws and cup washers in repairs complete all as specified and directed.
28M&L PVC single piece slim concealed cistern body with installation kit & P type drain pipe connection set for wall hung WC flushing cistern, with inlet, ball valve, float including fiush control plate and flush pipe and fixed in repairs complete all as specified and directed. Make: , Jaquar ;- JCS - WHT-2400P .
29S&F EWC wall hung WC With in built jet pp soft close silm seat hinges hind ware wall hanging type with plastic sheet cover all as specified and directed of size (H x W x P) 360 x 515 x 380 mm with ‘P’ trap distance 22.5 cm complete all as specified and directed. Make: , Jaquar ;- SLS-WHT-963UFSM .
30Supply only pillar tap 15 mm bore tall body Single Lever Basin Mixer hot and could without Popup Waste with 450mm Long Braided Hoses make- Jaguar OPP-CHR-15005BPM
31M&L oval type Wash basin, Vitreous China white (Flat back) 420 x 420 mm including fixing granit top counter basin including fixing of waste pipe,granit,wast cuppling and etc ( Suppy of pillar tap shall be measured separately) make Jaquar complete all as specified and directed.
32S & F stop valves 15mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions in repairs make- Jaguar complete all as specified and directed.
33S & F 50 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 PVC bends including all necessaryfixed complete to walls, ceilings or in floors etc.
34M&L bib tap brass 15mm bore dia chromium plated long shank fancy type 2-way Bib Cock with Wall Flange screwed for iron pipes complete in repairs complete all as specified and directed.
35M&L bib tap ,15 mm, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs make- Jaguar complete all as specified and directed.
36S&F in repairs brass chromium plated bathroom wall (wall mounted model) mixture with telephonic shower arrangement with swivel wall hook with and including old Victorian design telephone shower with 12mm dia 1.5m long flexible tube and swivel hook etc.
37S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position.
38Demolition and breaking up drain pipes (PVC,Salt glazed ware, AC or Reinforced concrete) set in cement mortar,internal dia of pipe in 75/110mm including earth work complete all as specified and directed.
39S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors
40S&F for PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as spd and directed.
41Taking down eaves gutter and rain water pipe any size any pattern ,PVC/ AC pipe including all fittings ,Internal dia of pipe in 75/110mm complete all as specified .
42S&F for PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
43S&F for PVC (SWR) bends ISI marked any radius 75mm dia complete all as spd and directed.
44S&F for PVC (SWR) bends ISI marked any radius 110mm dia complete all as spd and directed.
45S & F in repair for 15mm dia PVC connections 600mm long with PTMT nuts complete all as specified and directed.
46S&F in repair chrome finish Toilet paper Roll Holder with fixing arrangement Openable/Slideable complete all as specified and as directed.
47S&F in repair Stainless Steel Soap Dish or Soap Holder Dish for Bathroom with fixing arrangement Openable/Slideable complete all as specified and as directed.
48S & F in repair for 75mm PVC floor trap, ISI marked with perforated grating incl jointing to waste pipe fixed with solvent cement complete all as specified.
49S & F in repair for gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and as directed.
50Taking down chowkat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site complete all as specified and directed.
51Providing and fixing factory made uPVC white colour openable casement/sliding window/door, made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2+ 0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, all complete and as directed, (Including Glazing, hardware hinges and fitting, EPDM rubber gasket etc. and others Necessary Accessrories.)
52Providing and fixing factory made uPVC white colour casement Openable/Slideable Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including Neceassary channels, rails & fittings as reqired & drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.)
53S&Fing factory made uPVC white/ coloured fixed glazed Openable/Slideable window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality,. Including Glass 5.5mm size excand other Accessories all complete as per approved drawing & direction.
54S &F for 5.5mm thick selected quality toughened glass including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws etc in aluminum partition / doors / windows / ventilators etc complete all as specified and directed.
55S&F in repair Towel Rack 600mm Long with Lower Hangers, Stainless Steel complete all as specified and directed.
56S&F 40 mm Bottle trap of CP minimum water seal of 25mm .(Minimum weight 32 mm-380 gms/ 40mm-450 gms) complete all as specified and directed.
57Supply, fabricate and fixing with WPC board, one side decorative lamination and other side balancing white,100% termite proof,water proof,fire retardant, 18mm thick heavy density, interior grade cutting , fabricating and suitable fixing for bathroom cabinets and shelves of any size drawers openable leaf Kitchen cabinet, cupboard, partition & almirahs complete including fixing only accessories such as Italian stainless steel hinges, handles, magnets as required etc complete all as specified and directed as under , drawers Make-Syntex Plasto board and equivalent approved by Engr in charge. Note- The rate includes WPC board and all connecting items mentioned above and The design and pattern should be approved by Engr In Charge.
58S & F Self-closing hinges, heavy weight, cold rolled mild steel, and fixed hinges medium weight 100 -150 mm cold rolled mild steel in repair complete all as specified.
59S&F magnetic in reapir catcher and striking plate including letting in and fixed complete all as specified and directed.
60S & F heavy duty drawer slides track heavy weight, stainless steel, and fixed hinges medium weight 100 -150 mm stainless steel in repair complete all as specified.
61S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
62S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calciumcarbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
63Surface dressing in loose / soft soil n exc 15 cm deep complete all as specified and as directed.
64Excavating in any type of soil in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in loose / soft soil complete all as specified and as directed.
65Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
66Removing excavated materials( soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
67Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
68M&L for Hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm rammed to a true surface complete all as specified and directe.
69M&L for 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub floor, Sub bases, floors,Pinth protection and pavings etc complete all as specified and as directed.
70M&L for 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub floor, Sub bases, floors and pavings or to receive tile etc complete all as specified and as directed.
71Formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed.
72Formwork to Square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
73Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and as directed.
74M&L TMT bars 6mm to 8 mm cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
75M&L Reinforce cement concrete M-25 (Designmix) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
76M&L Reinforce cement concrete M-25 (Design mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
77M&L Reinforce cement concrete M-25 (Design mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
78M&L Reinforce cement concrete M-25 (Design mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
79M&L for brickwork with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and as directed.
80M & L for Brickwork with fly ash old size brick, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and as directed.
81M&L Rendering 15mm thick on fair faces of brickwork or concrete surfaces wall in cm 1:6 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
82M&L for preparation of newly plaster surfaces of walls and applying two coats of oil bound distemper over a priming coat of chalk whiting, on plastered surfaces, preparatory to distempring complete all as specified.
83M&L for preparation of newly plaster surfaces of walls and applying two coats of cement base paint over a priming coat of alkalies resistance priming paint complete all as specified.
84M&L for preparation of newly plaster surfaces of walls and applying three coats of white wash over ceiling complete all as specified and as directed.
85S&F Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20 mm thick screed bed in CM 1:6 complete all as specified.
86M&L for coloured Glazed ceramic tiles in vertical surface such as wall,dado etc 450mmX 300mmX 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:3 complete all as specified and directed by Engr-in-Charge.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles.
87S & F of 15mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc complete all as specified and as directed.
88Supplied and fixed 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
89S & F of vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including provision of lime concrete bedding, making good to floor and all fittings (excluding flushing cistern and flush pipe) complete all as specified and as directed.
90S & F of Wash basins, Vitreous China (flat back type) 550 x 400mm, including cutting for and pinning in ends of brackets or erecting stand , and 32 mm dia 75 cm long PVC flexible waste pipe etc complete all as specified and as directed.
91S & F for Viterous China urinal, half stall type, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including waste / Urinal pipe complete all as specified and as directed.
92S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed.
93S & F of PVC 10 ltrs capacity valveless symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete all as specified and as directed.
94S & F of PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
95S & F of Pillar taps fancy type cast copper alloy chromium plated with capstan head without letter Hot or Cold water screwed down for 15 mm dia iron pipe complete all as specified and as directed.
96S & F of 15mm bore dia of pipe bib taps cast copper alloy, fancy type chromium plated, with capstan head screwed down, high pressure screwed for iron pipe or brass ferrule complete all as specified and as directed.
97S & F of stop valve / angle cock fancy type cast copper alloy chromium plated with long shank and cup(concealed type) capstan head serewed down, high pressure for 15 mm dia iron pipe complete all as specified and as directed.
98S & F of CP Grating with hole /with out hole of dia 125 mm complete all as specified and as directed.
99S & F of looking mirror 600 x 450mm bevelled edges of selected quality glass mounted on 6mm commerical ply or AC building board with aluminium frame around and fixed to wooden plugs with CP brass screws complete all as specified and as directed.
100S & F of factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be coucred with heat moulded wood grain printed PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side as gap insert for top rail bottom rail panelling of wood grain printed PVC sheet to be fited in the MS frame welded/seald to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement suppling & fixed in the framed site as per specification & drawing complete all as specified and as directed.
101S & F of PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet reiforced with MS squre tube as per specification and drawing complete all as specified and as directed.
102S&F Steel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. Glazed and gauged shutter. Glazed shutter made out of hollow' section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill 10 mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast, including plain/figured glass 3mm thick and stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.18mm & fixed with stainless steel wire staples`etc complete all as per details shown in drawing No CEPZ/C-TD/032/13 sheet No 1/2 & 2/2 including taking down existing spoiled and unserviceable windows/ventilators of any type ( wooden/steel) complete all as specified and directed
103S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
104S & F of aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
105S & F of 150mm size,extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
106S & F of 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinges complete all as specified and as directed.
107S & F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as directed.
108S & F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as directed.
109S & F of 110 mm bore PVC (SWR) bends complete all as specified and as directed..
110S & F of 75/100mm PVC(SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and as directed.
111S & F of 110 mm bore PVC (SWR) junction t equal or unequle complete all as specified and as directed..
112S & F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including inlet & outlet tank nipple 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and directed by Engr-in-Charge.
113M&L on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil PCC 1:4:8 below fdn, vent shaft, connection etc complete for 20 users complete.all as specified and as directed by Engr-in-Charge.
114Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 complete.all as specified and as directed by Engr-in-Charge.
115Excavating over areas, n exc 1.5 m deep and getting out in loose / soft soil complete all as specified and as directed.
116M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded agg) as in Sub-base to floor finishes.
117M&L for coloured machine pressed precast rubber moulded concrete interlocking red/yellow) paver block of any shape and size with 6-8mm white cement layer mixed with pigment and coated with epoxy coating having glossy finish confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid dry over and including 50mm thick sand filling under paver, properly levelled etc, complete all as specified and directed.
118M&L for Plain Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directedcomplete all as specified and directed.
119Dismantling/Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified Note : Demolition should be done by chiselling.
120M&L for PCC 1 : 2 :4 type B0 (using 12.5mm graded stone aggregate) as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc mixed with approved water proofing compound all as per manufacturer'ss instructions on the roof surface to achieve requisite slope all as specified and directed. (Note : Supply only water proiofing compound shall be measured & paid separately)
121Supply only polymer based liquid water proofing compound complete all as specified and directed.
122M&L liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastometic liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster)
123Half Brick work with burnt clay brick work with sub-class 'B' bricks having crushing strength not less than 75 Kg/Sqm, straight or curved on plan exceeding 6 m mean radius with old size bricks built in cement mortar 1:4.
124M&L for 15mm thick cement plaster in cement mortar (1:6) on fair faces of brickwork or concrete surfaces and finished even and smooth without using extra cement .
125M&L for Preparation of new plastered or un-plastered surfaces of wall by applying 1.5 mm thick wall care putty on plastered surfaces of wall; internal /external Birla/JK white putty smooth finished ,Make Royal of Asian Paint or Nerolac impressions.
126M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over a coat of alkali resistant primer.etc complete all as specified and directed .
127M&L for Preparation of old plastered or un-plastered surfaces of wall by applying 1.5 mm thick wall care putty on plastered surfaces of wall internal /external ; Birla/JK white putty smooth finished ,Make Royal of Asian Paint or Nerolac impressions.
128M&L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying one coats of oil bound distemper primer complete all as specified and directed .
129M&L for complete removal of existing surfaces on wall and applying two coats of white wash with complete all as specified and directed.
130M & L for preparation of new plastered surfaces on ceiling and applying two coats of white wash with complete all as specified and directed.
131M&L for complete removal of existing surfaces on ceiling and applying two coats of white wash with complete all as specified and directed.
132M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with WPC @ 3 % by the weight of cement used and finishing even and smooth without using extra cement complete all as specified and directed..
133M&L for preparation of NEW plastered walls surfaces for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
134M&L for complete removal of existing surfaces including washing / rubbing down with water of wall for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
135Demolition of cement concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level)
136M &L PCC 1:3:6 type C2 75mm thick as in plinth protection finished even and smooth using extra cement compete all as specified.
137M&L 25mm thick cement concrete type B-1 1:2:4 (using 20mm graded stone aggragate) 0vr in base of floor
138Dismantling stone slabs or pcc tiles of any description or thickness in steps, landing, flooring and similar work laid, bedded and pointed in cement mortar complete.
139M&L for 15 -18mm thick granite stone slab (of any type) machine cut (in one piece) supported with 16mm thick marble stone base, bedded and jointed with gray cement slurry and pointed with white cement with admixture of pigment to match the shade of stone in cooking platforms WHB counter top, vertical supports including grinding and polishing complete all as specified and directed.
140Rounding to edges of stone slabs one edge, such as steps, cooking plateform, and other similar situations complete all as specified and directed.
141M&L Non - skid Ceramic tiles 7 to 8 mm thick of size 600mm x 600mm x 7 to 8 thick in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. incl 15 mm thick screed bed in cement mortar 1:6 including finishing even and fair complete all as specified.
142M&L Non - skid Ceramic tiles 7 to 8 mm thick of size 600mm x 600mm x 7 to 8 n vertical wall skirting etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as rendering cement plaster, 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces to receive tiles complete all as specified and directed.
143M&L Non skid ceramic colored tiles, edge cut 7 to 8mm thick square or rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18mm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile incl 15 mm thick screed bed in cement mortar 1:4 including finishing even and fair complete all as specified.
144M&L Coloured glazed ceramic tiles of size 350x 450 x 7mm thick,on vertical wall surface, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces inc rendering cement plaster, 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces to receive tiles complete all as specified and directed.
145M&L Johnson endura paving tiles of technocommercial equivalent of size 300x300x10mm thick set and jointed in neat cement slurry and pointed with white cement to match the joint incl 20 mm thick screed bed in cement mortar 1:4 over including finishing even and fair complete all as specified.
146M & L for 75 mm thick plain Cement concrete 1:4:8, type B-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and directed.
147Taking down chowkats of frames with shutters (without taking off shutters from frames) area exceeding 1.50 Sqm but n exc 4 sq. m each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damages to jambs , walls for taking out hold fast shall be finished idetical to existing finish without any all as specified and directed by Engr- in - charge
148Taking down chowkats of frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Sqm each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damages to jambs , walls for taking out hold fast shall be finished idetical to existing finish without any extra cost of Govt) all as specified and directed by Engr- in - charge
149Taking down shutters of any description exc.1 sq.m and n.exc. 2 sq.m Eachcomplete all as specified and directed.
150Dismantling of boarding ,any description and in any position (wall and ceiling boards or insulation boards any thickness, any description including cover fillets) (complete all as specified and directed
151S & F for suspended false ceiling system using chicago metallic (E grid) exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) complete all as specified and directed.
152S&F continous (piano) hinges 40 mm, mild steel, bright finish or electro-galvanised complete all as specified and directed.
153S&F 150mm size hasp & staple, aluminium anodised, safety type, including bolt to hinge plate and fixed with screws complete all as specified and directed.
154S&F for Pressed steel door frame of size 105x60mm, double rebated for doors made out of 1.25mm thick mild steel sheet including necessary fixing lugs, hinges lock strike plate etc, complete all as specified and directed.
155S&F Factory made 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
156S&F 35 mm thick, 2nd class hard wood factory made, glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a) complete all as specified and directed.
157S&F Factory made solid PVC door heat moulded frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, in opening as specified and directed.
158S&F Factory made solid panel PVC door shutter 24 to 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded both side prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing complete all as specified and directed.
159S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of exturded sections or cast aluminium alloy all as specified and directed
160S&F 150 mm long aluminium bow handles cast type anodised.
161S&F 200 mm long aluminium anodised barrel tower bolt of extruded section.
162S&F butt hinges med weight cold rolled MS, size 100 mm.
163S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed
164M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
165M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel pain complete all as specified.
166M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealedwater tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed
167Demolition carefully RCC work as in, Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended worketc by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of debris out side the MOD land. complete all as specified and directed.
168M&L reinforced cement concrete 1 : 2 : 4 type B-1 (12.5 mm graded stone aggregate) for Chajja beams, cantilevers etc complete all as specified and directed.
169M & L for Use and waste of Formwork to soffits of suspended slabs such as roof slabs,chajja, water tank staging floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)for flat and rough surfaces complete all as specified and directed.
170S&F rotational moulded polythylence water storage tanks 500 Ltr cylindrical vertaical with closed top) hoisted and fixed in position all as specified in SSR Pt-I of 500 ltrs including disconnecting the unserviceable existing tanks complete screwed for iron pipe or brass ferrule directed
171S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe),Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete, including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
172S&F vitreous China squatting pan, 'orrisa' pattern wc of size 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe but including 'P' or 'S' trap and provision of lime concrete bedding in repairs. Note:- flushing cistern and flush pipe will be measured and paid under supply only rate.
173Supply only PVC connector 15mm size with PTMT nuts of length 450mm
174M&L PVC valveless, syphonic action type, 10 ltrs cap flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe 32mm dia and fixed in repairs complete all as specified and directed.
175M&L Wash basin, Vitreous China white (Flat back) 630 x 450mm including fixing granit top with ceramic under counter basin pinning in ends of brackets or erecting stand including fixing of waste pipe and pillar tap and waste pipe complete all as specified and directed.
176S&F in repair 15mm bore dia brass CP mixcher for mixing hot and cold water screwed down for iron pipe and fixed for WHB bath complete all as specified and directied
177S & F Angular Stop Cock with Wall Flange 15mm bore dia, cast copper alloy fancy type jaqwarKUP-35053PM
178S&F in repair, water jet chromium plated for vitreous china pedestal pattern water closet of approved make all as specified and directed.
179S&F in repairs brass chromium plated towel rail 20mm dia, \\"D\\" type, 600mm long between flanges.
180S&F stainless steel soap dishes approximate size 160mm x 160mm x90mm as complete as specified as directed by Engineer-in-Charge.
181S&F Glass Assembly sheet glass consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracked guard and railing 60cm long in repairs complete all as specified and directed..
182S&F Brass chromium plated shower rose 125mm size including fixing to steel pipe or union in repairs complete all as specified and directed.
183S&F 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 PVC bends including all necessaryfixed complete to walls, ceilings or in floors etc.
184S&F 25mm dia, fancy type decorative,ss curtain rod in cluding brackets and nobs each road 2 nos complete all as specified and directed. Make- Vista, Marvel, Mac décor, Deck.
185S&F 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed
186Taking down AC / PVC rain water pipe any size or pattern incl all fittings heads, shoes, bends. Swan necks, etc including cleaning for refixing or removing to store.
187M&L for 110 mm dia PVC (SWR) pipe single socketed (ISI marked) fixed fixed to wall with mild steel clamps complete all as specified and directed.
188M&L PVC (SWR) 110mm bends any radiusequal complete all as specified and directed.
189M&L for 75 mm dia PVC (SWR) pipe single socketed (ISI marked) fixed fixed to wall with mild steel clamps complete all as specified and directed.
190M&L PVC (SWR) 75 mm bends any radiusequal complete all as specified and directed.
191M&L 100 mm ,PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
192M&L 100 mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
193S&F in repairs stainless steel sink with drainage board made of stainless steel 1mm thick kitchen or labouratory with plugs, washers, and wastes. including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm X 460mm and bowl size 410mm x 330mm x 160mm including necessary fittings such 40mm coupling waste, pipe complete all as specified and directed. Make : Nirali, Bule star ISI marked.
194S & F in repair 15mm bore dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for basin, sink, bath complete all as specified and directed.
195Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings or PVC sheet in roof including ridges, sunshades or any position etc complete all as specified and directed.
196S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in sunshades ,roof covering, cladding to wall etc fixed with self tapping screws complete all as specified and directed.
197S & F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall and as in ridge etc fixed with self-tapping screws complete all as specified and directed.
198Dismantling timber scantlings 40sqcm and over in section, in any position as in wooden trusses in framed work of any description complete all as specified and directed.
199S &F rolled hollow section as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters and rails and guides for sliding doors; and supports to roof covering, sun-shades,vertical poles etc fixed with angle cleats or other connecting plates Fe-410-W(Gde-E-250) quality B complete all as specified complete all as specified and directed.
200M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed complete all as specified and directed.
201Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area exc1.5 Sqm but n. exc 4 Sqm each and removing from site complete all as specified and directed by Engr-in-Charge.
202Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site complete all as specified and directed by Engr-in-Charge.
203S&F Anodised aluminium frame with Powder Coating (minimum thicknessof powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
204S&F Anodised aluminium door shutters/window/ventilator , aluminium section weighing 0.55 kg/ m with powder coating of any colour (Thickness or powder coating not less than 50 micron). including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
205S&F 5.5 mm thick sheet glass ordinary/tinted/frosted quality and glazing with neoprene rubber gasket/clip/oil putty/beading in square upto 2.0 sqm in each pane upto tripple story building complete all as specified and directed by Engr-in-Charge.
206S&F Powder coated Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed Length of bolt in 250 mm complete all as specified and directed by Engr-in-Charge.
207S&F Powder coated Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 150 mm complete all as specified and directed by Engr-in-Charge.
208S&F Powder coated Aluminium handles, cast type, anodised Size of handle in 150mm complete all as specified and directed by Engr-in-Charge.
209S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed by Engr-in-Charge.
210S & F of door closer aluminium (extruded section body) hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified and directed by Engr-in-Charge.
211Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast rcc articles and disposal of debris out of MoD land complete all as specified and directed by Engr-in-Charge.
212M&L Brickwork with sub class 'B' brick old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed by Engr-in-Charge.
213M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces of wall in cm 1:4 mixed with liquid water proofing compound finishing surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. Note :- All scaffolding work is including in this Item upto 4 Story in bldg.
214M & L for preparation of newly plastered surfaces of wall and applying minimum 02mm thick white cement based wall care putty on wall surfaces & making smooth surface and applying two coat of distemper oil emulsion over and including one coat of primer complete all as specified and directed. Please Enable Macros to View BoQ information
215M & L for preparation of newly plastered surfaces of wall and applying minimum 02mm thick white cement based wall care putty on wall surfaces & making smooth surface and applying two coat of distemper oil emulsion over and including one coat of primer complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57564339
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 34.03 Lakhs
LAST DATE 08-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn To Toilet Of Bldg No P-31 At Hq Ce Pathankot Zone, Provn Of 02 X Toilet With Allied Facilities At Central Sainik Gurudwara, Provn Of 11 X Alm Window With Net And 04 X Alm Door With Glass In Bldg No P-4 Of 131 Sho And special Repair To Bldg No Np-04, P-11 And Np-15 At Cwe Office In Aor Of Age B/R-1 Under Ge (West) Pathankot
Basic Detail
Tender No GE/PKT-58/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 17 Sep 2026
Submission Date 08 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 34.03 Lakhs
Tender Fee 500
EMD 68060
Exemption Not Available
Document List
2e6e1fe8-07f7-4e40-9178-4b9b5ec41d77.html
BOQ_885412.xls
tender58.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

2e6e1fe8-07f7-4e40-9178-4b9b5ec41d77.html

xls

BOQ_885412.xls

pdf

tender58.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders