Housing Urban and Rular Development Government Departments Closing in 12 days TDR #57562588

Tender For Dg - Chiplun ( Kherdi)...M&R To Streetlight At Kherdi & Khadpoli Indl. Area... Annual Comprehensive Maintenance Of Street Lights & High Mast Provided At Kherdi & Khadpoli Indl. Area.

Issued by Government Departments · Raigad, Maharashtra
Tender Value
33.18 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
12 days left
EMD
33200
Bank guarantee accepted
Document Fee
10030
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Dg - Chiplun ( Kherdi)...M&R To Streetlight At Kherdi & Khadpoli Indl. Area... Annual Comprehensive Maintenance Of Street Lights & High Mast Provided At Kherdi & Khadpoli Indl. Area.

BOQ

Name of Work:- DG - CHIPLUN ( KHERDI)...M&R to streetlight at Kherdi & Khadpoli Indl. Area… Annual Comprehensive maintenance of Street lights & High Mast provided at Kherdi & Khadpoli Indl. Area.
Sl. No. Item Description
1Sub Estimate - M&R to streetlight at Kherdi & Khadpoli Indl. Area…. Annual Comprehensive maintenance of Street lights & High Mast provided at Kherdi & Khadpoli Indl. Area.- Comprehensive Maintenance of street lights including providing licensed Electrician wiremen & labours for day to day checking, identifying & rectifying the faults in street light system, replacing of burnt accessories of street light LED fixtures, driver, LED panel, distribution box, wires, MCB'S, cables, earthing pipes, cables enclosure & straight joints etc. complete as directed by Engineer-in-Charge.
2Sub Estimate - M & R to Street light at Kherdi- Khadpoli Industrial Area... Replacement of damaged street lights poles & Highmast in Kherdi industrial area … 8.7 Dismantling - Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.
3C.C. Foundation- Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole).
4Making M-20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 2m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5m raising lowering high mast).
5Hot Dipped Galvanized Poles & High-Mast (OH-HM) --------- Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaries and its control gear box, lightning arrestor, arrangement for fixing aviation light, night glow reflector on pole at suitable height, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with double check nuts & necessary accessories complete. specification no. OH-PL/HM
6Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
7Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT
8Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, 45 A TP contactor for automatic switching of luminaries, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
9Bunch of Wires (WG-MA/BW) - Supplying and erecting PVC insulated PVC round sheathed FR 2.5 sq.mm (50 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV
10Cable Enclosures (CB-CE) ------------ Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
11Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete.
12Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means
13Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. -----------------(Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 382) In PCC M-150
14LT Cables (Aluminum) (CB-LT/AL)- Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
15Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
16LT - MCBs/ MCB Change Over Switch (SW-MCB) ---------- Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
17Plate, Pipe type Earthing (EA-EP) --------- Supplying, installing and testing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all accessories of copper materials & recording the results as per specification no. EA-EP
18Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP
19Accessories ----------- Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP.
20Outdoor Fittings (FG-ODF) ------ Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL.
21Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FG-ODF/FL.
22Credit for Dismantled Material- PVC armoured/unarmoured cables and wires (Aluminium)
23H.G. / M.S. / G.I. Materials / Poles etc.
24Street/flood light fittings. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57562588
AUTHORITY Government Departments
TENDER VALUE 33.18 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Maharashtra Industrial Development Corporation
Work Description Tender for Dg - Chiplun ( Kherdi)...M&R To Streetlight At Kherdi & Khadpoli Indl. Area... Annual Comprehensive Maintenance Of Street Lights & High Mast Provided At Kherdi & Khadpoli Indl. Area.
Basic Detail
Tender No 33,18,048.00
Bidding Type Tender
Location
City Raigad
State Maharashtra
Key Dates
Publish Date 17 Sep 2026
Submission Date 01 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 33.18 Lakhs
Tender Fee 10030
EMD 33200
Exemption Not Available
Document List
BOQ_2289813.xls
c5d2b14a-4f68-4bd5-a0cb-251fddefe811.html
ItemSpecification.pdf
TenderDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2289813.xls

html

c5d2b14a-4f68-4bd5-a0cb-251fddefe811.html

pdf

ItemSpecification.pdf

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders